Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Sports Med ; 50(3): 597-614, 2020 Mar.
Article in English | MEDLINE | ID: mdl-31571156

ABSTRACT

INTRODUCTION: Fat is a metabolic fuel, but excess body fat is ballast mass, and therefore, many elite athletes reduce body fat to dangerously low levels. Uncompressed subcutaneous adipose tissue (SAT) thickness measured by brightness-mode ultrasound (US) provides an estimate of body fat content. METHODS: The accuracy for determining tissue borders is about 0.1-0.2 mm and reliability (experienced measurers) was within ± 1.4 mm (95% limit of agreement, LOA). We present here inter- and intra-measurer scores of three experienced US measurers from each of the centres C1 and C2, and of three novice measurers from each of the centres C3-C5. Each of the five centres measured 16 competitive adult athletes of national or international level, except for one centre where the number was 12. The following sports were included: artistic gymnastics, judo, pentathlon, power lifting, rowing, kayak, soccer, tennis, rugby, basketball, field hockey, water polo, volleyball, American football, triathlon, swimming, cycling, long-distance running, mid-distance running, hurdles, cross-country skiing, snowboarding, and ice hockey. SAT contour was detected semi-automatically: typically, 100 thicknesses of SAT at a given site (i.e., in a given image), with and without fibrous structures, were measured. RESULTS: At SAT thickness sums DI (of eight standardised sites) between 6.0 and 70.0 mm, the LOA of experienced measurers was 1.2 mm, and the intra-class correlation coefficient ICC was 0.998; novice measurers: 3.1 mm and 0.988. Intra-measurer differences were similar. The median DI value of all 39 female participants was 51 mm (11% fibrous structures) compared to 17 mm (18%) in the 37 male participants. DISCUSSION: DI measurement accuracy and precision enables detection of fat mass changes of approximately 0.2 kg. Such reliability has not been reached with any other method. Although females' median body mass index and mass index were lower than those of males, females' median DI was three times higher, and their percentage of fibrous structures was lower. The standardised US method provides a highly accurate and reliable tool for measuring SAT and thus changes in body fat, but training of measurers is important.


Subject(s)
Athletes , Body Composition , Body Weight , Subcutaneous Fat , Adult , Female , Humans , Male , Reproducibility of Results , Subcutaneous Fat/diagnostic imaging
2.
Br J Sports Med ; 50(1): 45-54, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26702017

ABSTRACT

BACKGROUND: Precise and accurate field methods for body composition analyses in athletes are needed urgently. AIM: Standardisation of a novel ultrasound (US) technique for accurate and reliable measurement of subcutaneous adipose tissue (SAT). METHODS: Three observers captured US images of uncompressed SAT in 12 athletes and applied a semiautomatic evaluation algorithm for multiple SAT measurements. RESULTS: Eight new sites are recommended: upper abdomen, lower abdomen, erector spinae, distal triceps, brachioradialis, lateral thigh, front thigh, medial calf. Obtainable accuracy was 0.2 mm (18 MHz probe; speed of sound: 1450 m/s). Reliability of SAT thickness sums (N=36): R(2)=0.998, SEE=0.55 mm, ICC (95% CI) 0.998 (0.994 to 0.999); observer differences from their mean: 95% of the SAT thickness sums were within ± 1 mm (sums of SAT thicknesses ranged from 10 to 50 mm). Embedded fibrous tissues were also measured. CONCLUSIONS: A minimum of eight sites is suggested to accommodate inter-individual differences in SAT patterning. All sites overlie muscle with a clearly visible fascia, which eases the acquisition of clear images and the marking of these sites takes only a few minutes. This US method reaches the fundamental accuracy and precision limits for SAT measurements given by tissue plasticity and furrowed borders, provided the measurers are trained appropriately.


Subject(s)
Sports/physiology , Subcutaneous Fat/anatomy & histology , Athletic Performance/physiology , Body Composition/physiology , Body Fat Distribution , Female , Health Status , Humans , Male , Muscle, Skeletal/anatomy & histology , Muscle, Skeletal/diagnostic imaging , Observer Variation , Subcutaneous Fat/diagnostic imaging , Ultrasonography
SELECTION OF CITATIONS
SEARCH DETAIL
...