1.
Anal Chem ; 86(23): 11614-9, 2014 Dec 02.
Article in English | MEDLINE | ID: mdl-25329684

ABSTRACT

Surface-enhanced Raman scattering (SERS) optical nanoprobes offer a number of advantages for ultrasensitive analyte detection. These functionalized colloidal nanoparticles are a multifunctional assay component. providing a platform for conjugation to spectral tags, stabilizing polymers, and biorecognition elements such as aptamers or antibodies. We demonstrate the design and characterization of a SERS-active nanoprobe and investigate the nanoparticles' biorecognition capabilities for use in a competitive binding assay. Specifically, the nanoprobe is designed for the quantification of bisphenol A (BPA) levels in the blood after human exposure to the toxin in food and beverage plastic packaging. The nanoprobes demonstrated specific affinity to a BPA aptamer with a dissociation constant Kd of 54 nM, and provided a dose-dependent SERS spectra with a limit of detection of 3 nM. Our conjugation approach shows the versatility of colloidal nanoparticles in assay development, acting as detectable spectral tagging elements and biologically active ligands concurrently.


Subject(s)
Aptamers, Nucleotide/chemistry , Aptamers, Nucleotide/chemical synthesis , Benzhydryl Compounds/blood , Drug Design , Nanoparticles/chemistry , Phenols/blood , Spectrum Analysis, Raman , Humans , Molecular Structure , Surface Properties
2.
Langmuir ; 30(20): 5903-10, 2014 May 27.
Article in English | MEDLINE | ID: mdl-24787428

ABSTRACT

Layer-by-layer (LbL) capsules, known for their versatility and smart response to environmental stimuli, have attracted great interest in drug delivery applications. However, achieving a desired drug delivery system with sustained and tunable drug release is still challenging. Here, a thermoresponsive drug delivery system of solid dexamethasone nanoparticles (DXM NPs, 200 ± 100 nm) encapsulated in a model LbL assembly of tunable thickness consisting of strong polyelectrolytes poly(diallyldimethylammonium chloride)/poly(styrenesulfonate) (PDAC/PSS) is constructed. The influence of various parameters on drug release, such as number of layers, ionic strength of the adsorption solution, temperature, and outermost layer, is investigated. Increasing the number of layers results in a thicker encapsulating nanoshell and decreases the rate of dexamethasone release. LbL assemblies created in the absence of salt are most responsive to temperature, yielding the greatest contrast in drug release. Relationships between drug release and LbL architecture are attributed to the size and concentration of free volume cavities within the assemblies. By tailoring the properties of those cavities, a thermoresponsive drug delivery system may be obtained. This work provides a promising example of how LbL assemblies may be implemented as temperature-gated materials for the controlled release of drug, thus providing an alternative approach to the delivery of therapeutics with reduced toxic effects.


Subject(s)
Anti-Inflammatory Agents/chemistry , Dexamethasone/chemistry , Drug Delivery Systems , Nanoparticles/chemistry , Polyethylenes/chemistry , Polystyrenes/chemistry , Quaternary Ammonium Compounds/chemistry , Hot Temperature
3.
Biomacromolecules ; 12(9): 3205-12, 2011 Sep 12.
Article in English | MEDLINE | ID: mdl-21786828

ABSTRACT

Paclitaxel nanoparticles (PAX NPs) prepared with the size of 110 ± 10 nm and ζ potential of -40 ± 3 mV were encapsulated in synthetic/biomacromolecule shell chitosan, dextran-sulfate using a layer-by-layer self-assembly technique. Zeta potential measurements, analysis of X-ray photoelectron spectroscopy, and scanning electron microscopy confirmed the successful adsorption of each layer. Surface modifications of these core-shell NPs were performed by covalently conjugating with poly(ethylene glycol) (H(2)N-PEG-carboxymethyl, M(w) 3400) and fluorescence labeled wheat germ agglutinin (F-WGA) to build a biocompatible and targeted drug delivery system. 32% of PAX was released from four bilayers of biomacromolecule assembled NPs within 8 h as compared with >85% of the drug released from the bare NPs. Moreover, high cell viability with PEG conjugation and high binding capacity of WGA-modified NPs with Caco-2 cells were observed. This biocompatible and targeted NP-based drug delivery system, therefore, may be considered as a potential candidate for the treatment of colonic cancer and other diseases.


Subject(s)
Antineoplastic Agents, Phytogenic/pharmacology , Biocompatible Materials/pharmacology , Colonic Neoplasms/drug therapy , Drug Carriers/chemical synthesis , Drug Compounding/methods , Molecular Targeted Therapy/methods , Nanoparticles/chemistry , Paclitaxel/pharmacology , Antineoplastic Agents, Phytogenic/chemistry , Biocompatible Materials/chemistry , Caco-2 Cells , Cell Survival/drug effects , Chitosan/chemistry , Colonic Neoplasms/pathology , Dextran Sulfate/chemistry , Drug Carriers/pharmacology , Fluorescence , Humans , Kinetics , Microscopy, Electron, Scanning , Nanoparticles/ultrastructure , Paclitaxel/chemistry , Particle Size , Photoelectron Spectroscopy , Polyethylene Glycols/chemistry , Surface Properties , Wheat Germ Agglutinins/analysis , Wheat Germ Agglutinins/chemistry , Wheat Germ Agglutinins/metabolism
4.
Biomed Opt Express ; 2(5): 1243-57, 2011 Apr 18.
Article in English | MEDLINE | ID: mdl-21559135

ABSTRACT

Proper management of diabetes requires the frequent measurement of a patient's blood glucose level. To create a long-term, minimally-invasive sensor that is sensitive to physiological concentrations of glucose a fluorescent glucose sensing assay using a competitive binding approach between fluorescently tagged Concanavalin-A (Con-A) and glycodendrimer is being developed. Until now, the essential step of effectively encapsulating this aggregative sensing assay while allowing a reversible response has yet to be reported. In this paper, a microporation technique is described in which microspheres are synthesized in a manner that creates fluid-filled pores within a poly (ethylene glycol) hydrogel. This dual-nature technique creates hydrophilic, biocompatible microcapsules in which the aggregative binding kinetics of the sensing assay within the pores are not constrained by spatial fixation in the hydrogel matrix. Confocal images displaying the localization of pockets filled with the assay within the polymeric matrix are presented in this paper. In addition, fluorescent responses to varying glucose concentrations, leaching studies, and long-term functionality of the encapsulated assay are demonstrated. To our knowledge, this is the first time that the Con-A/glycodendrimer assay has been shown to be reversible and repeatable within hydrogel spheres, including the display of functionality up to fourteen days under ambient conditions.

5.
Biomacromolecules ; 8(6): 2004-10, 2007 Jun.
Article in English | MEDLINE | ID: mdl-17511501

ABSTRACT

An electrostatic layer-by-layer self-assembly technique was used to encapsulate solid core paclitaxel nanoparticles within a polymeric nanometer-scale shell. This approach provides a new strategy for the development of polymeric vehicles that control drug release and target diseased tissues and cells specific to the ailment, such as breast cancer. Core paclitaxel nanoparticles, 153 +/- 28 nm in diameter, were prepared using a modified nanoprecipitation technique. A nanoshell composed of multilayered polyelectrolytes, poly(allylamine hydrochloride) and poly(styrene-4-sulfonate) was assembled stepwise onto core charged drug nanoparticles. In vitro studies were performed to determine the anticancer activity of paclitaxel core-shell nanoparticles. Paclitaxel core-shell nanoparticles induced cell cycle arrest in the G2/M phase after 24 and 48 h of incubation with a human breast carcinoma cell line, MCF-7. Changes in MCF-7 cell morphology, fragmentation of the nucleus, and loss of cell-cell contacts indicated that the cells responded to paclitaxel core nanoparticles upon treatment for 24 and 48 h. Cells arrested in G2/M phase illustrated abnormal microtubule and actin cytoskeleton morphology. The core-shell drug nanoparticles fabricated using this procedure provide a new approach in the delivery of paclitaxel devoid of Cremophor EL, a solvent that causes adverse side effects in patients undergoing chemotherapy for treatment of metastasized mammary cancers.


Subject(s)
Drug Delivery Systems , Macromolecular Substances/chemistry , Nanoparticles/chemistry , Neoplasms/drug therapy , Paclitaxel/chemistry , Cell Cycle/drug effects , Cell Line, Tumor , Cytoskeleton/metabolism , Glycerol/analogs & derivatives , Glycerol/chemistry , Humans , Microscopy, Electron, Scanning , Microscopy, Electron, Transmission , Microscopy, Fluorescence , Polymers/chemistry , Solvents/chemistry
6.
Langmuir ; 23(13): 7018-23, 2007 Jun 19.
Article in English | MEDLINE | ID: mdl-17506587

ABSTRACT

Hyperbranching poly(allylamine) (PAAm) and poly(ethylene glycol) (PEG) on silicon and its effect on protein adhesion was investigated. Hyperbranching involves sequential grafting of polymers on a surface with one of the components having multiple reactive sites. In this research, PAAm provided multiple amines for grafting PEG diacrylate. Current methodologies for generating PEG surfaces include PEG-silane monolayers or polymerized PEG networks. Hyperbranching combines the nanoscale thickness of monolayers with the surface coverage afforded by polymerization. A multistep approach was used to generate the silicon-supported hyperbranched polymers. The silicon wafer surface was initially modified with a vinyl silane followed by oxidation of the terminal vinyl group to present an acid function. Carbodiimide activation of the surface carboxyl group allowed for coupling to PAAm amines to form the first polymer layer. The polymers were hyperbranched by grafting alternating PEG and PAAm layers to the surface using Michael addition chemistry. The alternating polymers were grafted up to six total layers. The substrates remained hydrophilic after each modification. Static contact angles for PAAm (32-44 degrees) and PEG (33-37 degrees) were characteristic of the corresponding individual polymer (30-50 degrees for allylamine, 34-42 degrees for PEG). Roughness values varied from approximately 1 to 8 nm, but had no apparent affect on protein adhesion. Modifications terminating with a PEG layer reduced bovine serum albumin adhesion to the surface by approximately 80% as determined by ELISA and radiolabel binding studies. The hyperbranched PAAm and PEG surfaces described in this paper are nanometer-scale, multilayer films capable of reducing protein adhesion.


Subject(s)
Membranes, Artificial , Ovalbumin/chemistry , Polyamines/chemistry , Polyethylene Glycols/chemistry , Serum Albumin, Bovine/chemistry , Silicon , Animals , Cattle , Chickens , Protein Binding , Surface Properties
7.
Biomacromolecules ; 8(6): 1958-65, 2007 Jun.
Article in English | MEDLINE | ID: mdl-17477569

ABSTRACT

Fabricating drug particles for therapeutic delivery and imaging presents important challenges in the design of the particle surfaces. Drug nanoparticle surfaces are currently functionalized with site-specific targeting ligands, biocompatible polymers, or fluorophore-polymer conjugates for specific imaging. However, if these functionalizations were to be synthesized on the drug carrier in localized, nanoscale regions on the particle surface, new schemes of drug delivery could be realized. Here we describe the use of our particle lithography technique that enables the synthesis of individual colloidal carrier assemblies that can be imaged and targeted to integrin-expressing cells. We show localized adhesion specificity for cells expressing the target integrin followed by receptor-mediated endocytosis. With the addition of localized delivery by adding drug nanoparticles to a specific region on the particle surface, our colloidal carrier assemblies have the potential to target, deliver therapeutic agents to, sense, and image diseased endothelium.


Subject(s)
Colloids/chemistry , Microscopy, Confocal/instrumentation , Nanoparticles/chemistry , 3T3 Cells , Animals , Biocompatible Materials/chemistry , Cell Adhesion , Drug Delivery Systems , Endocytosis , Endothelium/metabolism , Image Processing, Computer-Assisted , Ligands , Mice , Microscopy, Confocal/methods , Polymers/chemistry , Surface Properties
8.
Langmuir ; 23(2): 747-54, 2007 Jan 16.
Article in English | MEDLINE | ID: mdl-17209629

ABSTRACT

Here, we described the in vitro biocompatibility of a novel nanostructured surface composed of PTFE as a potential polymer for the prevention of adverse host reactions to implanted devices. The foreign body response is characterized at the tissue-material interface by several layers of macrophages and large multinucleated cells known as foreign body giant cells (FBGC), and a fibrous capsule. The nanofibers of nanofibrous PTFE (nPTFE) range in size from 20 to 30 nm in width and 3-4 mm in length. Glass surfaces coated with nPTFE (produced by jet-blowing of PTFE 601A) were tested under in vitro conditions to characterize the amount of protein adsorption, cell adhesion, and cell viability. We have shown that nPTFE adsorbs 495 +/- 100 ng of bovine serum albumin (BSA) per cm2. This level was considerably higher than planar PTFE, most likely due to the increase in hydrophobicity and available surface area, both a result of the nanoarchitecture. Endothelial cells and macrophages were used to determine the degree of cell adsorption on the surface of the nanostructured polymer. Both cell types were significantly more round and occupied less area on nPTFE as compared to tissue culture polystyrene (TCPS). Furthermore, a larger majority of the cells on the nPTFE were dead compared to TCPS, at dead-to-live ratios of 778 +/- 271 to 1 and 23 +/- 5.6 to 1, respectively. Since there was a high amount of cell death (due to either apoptosis or necrosis), and the foreign body response is a form of chronic inflammation, an 18 cytokine Luminex panel was performed on the supernatant from macrophages adherent on nPTFE and TCPS. As a positive control for inflammation, lipopolysaccharide (LPS) was added to macrophages on TCPS to estimate the maximum inflammation response of the macrophages. From the data presented with respect to IL-1, TNF-alpha, IFN-gamma, and IL-5, we concluded that nPTFE is nonimmunogenic and should not yield a huge inflammatory response in vivo, and cell death observed on the surface of nPTFE was likely due to apoptosis resulting from the inability of cells to spread on these surface. On the basis of the production of IL-1, IL-6, IL-4, and GM-CSF, we concluded that FBGC formation on nPTFE may be decreased as compared to materials known to elicit FBGC formation in vivo.


Subject(s)
Biocompatible Materials/chemistry , Polytetrafluoroethylene/chemistry , Adsorption , Animals , Cell Adhesion , Cell Survival , Chemistry, Physical/methods , Cytokines/metabolism , Inflammation , Macrophages/metabolism , Mice , Microscopy, Electron, Scanning , Nanoparticles/chemistry , Polystyrenes/chemistry , Surface Properties
9.
J Diabetes Sci Technol ; 1(3): 366-71, 2007 May.
Article in English | MEDLINE | ID: mdl-19885091

ABSTRACT

BACKGROUND: Currently, monitoring blood glucose levels for diabetic patients is invasive and painful, involving pricking the finger to obtain a blood sample three to four times daily. The need for frequent tests and pain involved with testing leads to poor compliance. In order to raise compliance, we propose to create an implantable electrochemical sensor array that would monitor glucose levels continuously. METHODS: Glucose sensor arrays were fabricated on gold electrodes on flexible polyimide sheets by photopolymerization of the biocompatible polymer poly(ethylene glycol) diacrylate (PEG-DA) to develop hydrogels and encapsulate the sensing elements. Using conventional silicon fabrication methods, arrays of five gold microdisk electrodes were fabricated using lift-off photolithography and sputtering techniques. A redox polymer was then attached electrostatically to the electrode, and glucose oxidase was entrapped inside the hydrogel on the array of electrodes by ultraviolet-initiated photopolymerization of PEG-DA. RESULTS: When the array of fabricated sensors was sampled together the elements behaved like one large electrode with peak current equivalent to the sum of individual array elements. The enzyme, glucose oxidase, catalyzed the oxidation of glucose and then exchanged electrons with the redox polymer in the hydrogel. The entrapped glucose oxidase was found to respond linearly to increasing glucose concentrations (0-360 mg/dl), as determined using cyclic voltammetry. CONCLUSION: The fabricated microarray sensors were individually addressable and showed no cross talk between adjacent array elements as assessed using cyclic voltammetry. We have fabricated an array of glucose sensors on flexible polyimide sheets that exhibits the desired linear response in the biological range.

10.
J Fluoresc ; 17(1): 57-63, 2007 Jan.
Article in English | MEDLINE | ID: mdl-17111227

ABSTRACT

Poly(ethylene glycol) (PEG) hydrogels have been used to encapsulate fluorescently labeled molecules in order to detect a variety of analytes. The hydrogels are designed with a mesh size that will retain the sensing elements while allowing for efficient diffusion of small analytes. Some sensing assays, however, require a conformational change or binding of large macromolecules, which may be sterically prohibited in a dense polymer matrix. A process of hydrogel microporation has been developed to create cavities within PEG microspheres to contain the assay components in solution. This arrangement provides improved motility for large sensing elements, while limiting leaching and increasing sensor lifetime. Three hydrogel compositions, 100% PEG, 50% PEG, and microporated 100% PEG, were used to create pH-sensitive microspheres that were tested for response time and stability. In order to assess motility, a second, more complex sensor, namely a FITC-dextran/TRITC-Con A glucose-specific assay was encapsulated within the microspheres.


Subject(s)
Fluorescence , Glucose/analysis , Hydrogels/chemistry , Microspheres , Polyethylene Glycols/chemistry , Capsules , Concanavalin A/chemistry , Concanavalin A/metabolism , Dextrans/chemistry , Dextrans/metabolism , Fluorescein-5-isothiocyanate/chemistry , Fluorescein-5-isothiocyanate/metabolism , Fluorescent Dyes/chemistry , Fluorescent Dyes/metabolism , Glucose/chemistry , Hydrogen-Ion Concentration , Lectins/chemistry , Lectins/metabolism , Polymers/analysis , Polymers/chemistry , Porosity , Rhodamines/chemistry , Rhodamines/metabolism , Solutions/chemistry , Time Factors , Water/chemistry
11.
Langmuir ; 22(19): 8178-85, 2006 Sep 12.
Article in English | MEDLINE | ID: mdl-16952259

ABSTRACT

The in vitro uptake of core-shell nanoparticles encapsulated in a bio-macromolecular nanoshell assembled from multilayered polyelectrolytes was studied. Sulfate modified fluorescent polystyrene nanobeads (diameter 200 nm) were used as a solid core upon which charged multilayers of poly-l-lysine, chitosan, and heparin sulfate are electrostatically deposited utilizing a layer-by-layer (LbL) self-assembly process. The nanoshell composed of the multilayered polyelectrolytes was modified with poly(ethylene glycol) (PEG) of varying molecular weights (either MW 2000, 5000, or 20 000 Da) to form a hydrophilic and long-circulating nanoparticle. The assembly of the nanoshell was confirmed by zeta potential, transmission electron microscopy (TEM), and X-ray photoelectron spectroscopy (XPS). The reversal in charge upon the deposition of alternating polyelectrolytes was observed by zeta potential measurements. The nanometer thickness of the nanoshell was confirmed by TEM. The presence of the (C-C-O)(n)() backbone in PEG at the surface of the nanoshell was confirmed by the increase in (C-O,N) peak area concentrations compared to (C-C) peak area, and these results were gathered from XPS. In vitro studies between suspension macrophages and core-shell nanoparticles were performed to determine how the hydrophilicity and the charge on the nanoshell can promote or reduce uptake. Results showed that after 24 h uptake was decreased 3-fold when PEGs of 2000 and 20 000 Da were chemisorbed to the nanoshell, as opposed to a nanoshell with either a positive or highly negative charge. Confocal microscopy aided in verifying that core-shell nanoparticles were internalized within the cell cytoplasm and were not attached to the cell surface. Protein adhesion studies with bovine serum albumin were performed to determine the relationship between surface charge and opsonization of core-shell nanoparticles. It was found that a hydrophilic surface with a low negative charge reduced protein adsorption and uptake. The in vitro uptake of macrophages and protein adsorption onto core-shell nanoparticles formed using layer-by-layer assembly has not been previously studied.


Subject(s)
Macrophages/metabolism , Nanoparticles , Polyethylene Glycols/chemistry , Polyethylene Glycols/pharmacokinetics , Adsorption , Animals , Cells, Cultured , Chitosan/chemistry , Heparin/chemistry , Latex/chemistry , Macrophages/chemistry , Microscopy, Electron, Transmission , Nanoparticles/ultrastructure , Polylysine/chemistry , Polystyrenes/chemistry , Proteins/chemistry , Spectrum Analysis , Surface Properties
12.
Anal Bioanal Chem ; 385(8): 1389-97, 2006 Aug.
Article in English | MEDLINE | ID: mdl-16847626

ABSTRACT

This paper describes microfluidic systems containing immobilized hydrogel-encapsulated mammalian cells that can be used as cell-based biosensors. Mammalian cells were encapsulated in three-dimensional poly(ethylene glycol)(PEG) hydrogel microstructures which were photolithographically polymerized in microfluidic devices and grown under static culture conditions. The encapsulated cells remained viable for a week and were able to carry out enzymatic reactions inside the microfluidic devices. Cytotoxicity assays proved that small molecular weight toxins such as sodium azide could easily diffuse into the hydrogel microstructures and kill the encapsulated cells, which resulted in decreased viability. Furthermore, heterogeneous hydrogel microstructures encapsulating two different phenotypes in discrete spatial locations were also successfully fabricated inside microchannels.


Subject(s)
Biosensing Techniques/methods , Hydrogel, Polyethylene Glycol Dimethacrylate/chemistry , Microfluidic Analytical Techniques , Microfluidics/methods , 3T3 Cells , Animals , Cells, Immobilized/drug effects , Cells, Immobilized/physiology , Mice , Sodium Azide/toxicity
13.
Anal Chem ; 77(24): 7887-93, 2005 Dec 15.
Article in English | MEDLINE | ID: mdl-16351134

ABSTRACT

Here, we describe the fabrication of whole mammalian cell biosensors for the optical monitoring of cell viability. Three phenotypes were examined for their response to the addition of two model chemotoxins: sodium hypochlorite and sodium azide, and one model biotoxin, concanavalin A. Two sensing platforms containing cells, hydrogel microspheres, or hydrogel arrays, were also explored. Step changes in viability in response to small doses of sodium hypochlorite were seen nearly instantaneously in all cell lines, in solution, microspheres, and microarrays. Linear detection of sodium azide by entrapped hepatocytes was 0-10 microM, whereas the linear detection range for macrophages and endothelial cells was 0-75 microM. Macrophages and hepatocytes have a greater sensitivity, as indicated by a 40% change in fluorescence over the linear range, whereas endothelial cells show only a 15% change in fluorescence over the linear range. Using photoreaction injection molding, we were also able to generate a multiphenotype sensor that enables the measurement of the toxic effect of 100 microg/mL concanavalin A on macrophages and hepatocytes, but not on endothelial cells.


Subject(s)
Biosensing Techniques/instrumentation , Cell Survival , Animals , Biosensing Techniques/methods , Cells, Cultured , Concanavalin A/toxicity , Endothelial Cells/drug effects , Fluoresceins , Hepatocytes/drug effects , Macrophages/drug effects , Mice , Microspheres , Polyethylene Glycols , Sodium Azide/toxicity , Sodium Hypochlorite/toxicity
14.
Langmuir ; 21(24): 11352-6, 2005 Nov 22.
Article in English | MEDLINE | ID: mdl-16285810

ABSTRACT

Phospholipid films have been shown in a number of studies to exhibit potential as nonfouling surfaces for biomaterial applications. However, the practical application of such films has been hindered by instability in aqueous solutions and significant detachment under mild shear stresses. Methods for stabilizing lipid films have been investigated, but to date require the presence of specific functional groups or chemical modification of the lipid molecule. In contrast to these methods, we present a process for heat-stabilization of lipid films. These heat-stabilized films have been shown to be able to withstand repeated rinsing without significant detachment. Phosphatidylcholine monolayers were formed on hydrophobic self-assembled monolayers using the liposome fusion method and stabilized at 80 degrees C. The films were characterized using Fourier transform infrared spectroscopy, ellipsometry, and atomic force microscopy and were shown to be defect free after repeated rinsing. Further experiments using a quartz crystal microbalance showed that the heat-stabilized lipid films were highly resistant to nonspecific protein adhesion and compared very favorably with poly(ethylene glycol)-coated surfaces under identical exposure conditions.


Subject(s)
Biocompatible Materials/chemistry , Phospholipids/chemistry , Proteins/chemistry , Adsorption , Hot Temperature , Microscopy, Atomic Force , Phosphatidylcholines , Spectroscopy, Fourier Transform Infrared , Surface Properties
15.
Anal Chem ; 77(21): 6828-33, 2005 Nov 01.
Article in English | MEDLINE | ID: mdl-16255579

ABSTRACT

We describe the fabrication and characterization of poly(ethylene glycol) (PEG) hydrogel spheres containing the enzyme horseradish peroxidase (HRP) for application as optical nanosensors for hydrogen peroxide. HRP was encapsulated in PEG hydrogel spheres by reverse emulsion photopolymerization, yielding spheres with a size range from 250 to 350 nm. Encapsulated HRP activity and sensitivity to hydrogen peroxide were investigated by the Amplex Red assay based on the fluorescence response as a function of H2O2. These HRP-loaded spheres were then introduced to murine macrophages with Amplex Red in the culture media. After phagocytosis, the biocompatibility of spheres was determined by live cell staining using calcein AM (5 microM). The HRP-loaded PEG hydrogel spheres were activated (i.e., fluorescent oxidized Amplex Red produced within the spheres) by oxidative stresses such as exogenous H2O2 (100 microM) and lipopolysaccharide (1 microg/mL), which induced the production of endogenous peroxide inside macrophages. The results presented here indicate that after polymerization, the enzyme activity of HRP was still maintained and that using these HRP-containing nanospheres, peroxide production could be sensed locally within cells.


Subject(s)
Horseradish Peroxidase/chemistry , Microchemistry/methods , Nanotechnology , Oxidative Stress , Polyethylene Glycols/chemistry , Animals , Horseradish Peroxidase/metabolism , Macrophages/metabolism , Mice , Phagocytosis/physiology
16.
Anal Chem ; 77(21): 7039-46, 2005 Nov 01.
Article in English | MEDLINE | ID: mdl-16255607

ABSTRACT

A new fluorescent glucose assay has been created using Alexa Fluor 647-labeled concanavalin A (Con A) and a fourth-generation PAMAM Alexa Fluor 594-labeled glycodendrimer. This assay has been shown to have a large response to glucose within the biological range and to be capable of functioning within a polymer hydrogel. In this paper, the glucose response is shown to be a single fluorophore-based quenching reaction. Data showing that the sensor is fully reversible and specific through competitive binding between the dendrimer and glucose with Con A are presented. Overall, the assay is shown to have potential over the traditional dextran-based assay because it has a larger dynamic response to physiological glucose concentrations, incorporates longer wavelength dyes that improve signal penetration through dermal tissue, and provides an internal reference in the form of a nonreactive fluorescent label.


Subject(s)
Cyclic AMP/analogs & derivatives , Glucose/chemistry , Binding, Competitive , Concanavalin A/chemistry , Cyclic AMP/chemistry , Organic Chemicals/chemistry , Sensitivity and Specificity
17.
Nano Lett ; 5(9): 1852-6, 2005 Sep.
Article in English | MEDLINE | ID: mdl-16159237

ABSTRACT

The research described here investigates the hypothesis that nanoarchitecture contained in a nanowire array is capable of attenuating the adverse host response generated when medical devices are implanted in the body. This adverse host response, or biofouling, generates an avascular fibrous mass transfer barrier between the device and the analyte of interest, disabling the implant if it is a sensor. Numerous studies have indicated that surface chemistry and architecture modulate the host response. These findings led us to hypothesize that nanostructured surfaces will inhibit the formation of an avascular fibrous capsule significantly. We are investigating whether arrays of oscillating magnetostrictive nanowires can prevent protein adsorption. Magnetostrictive nanowires were fabricated by electroplating a ferromagnetic metal alloy into the pores of a nanoporous alumina template. The ferromagnetic nanowires are made to oscillate by oscillating the magnetic field surrounding the wires. Radiolabeled bovine serum albumin, enzyme-linked immunosorbent assay (ELISA), and other protein assays were used to study protein adhesion on the nanowire arrays. These results display a reduced protein adsorption per surface area of static nanowires. Comparing the surfaces, 14-30% of the protein that absorbed on the flat surface adsorbed on the nanowires. Our contact angle measurements indicate that the attenuation of protein on the nanowire surface might be due to the increased hydrophilicity of the nanostructured surface compared to a flat surface of the same material. We oscillated the magnetostrictive wires by placing them in a 38 G 10 Hz oscillating magnetic field. The oscillating nanowires show a further reduction in protein adhesion where only 7-67% of the protein on the static wires was measured on the oscillating nanowires. By varying the viscosity of the fluid the nanowires are oscillated in, we determined that protein detachment is shear-stress modulated. We created a high shearing fluid with dextran, which reduced protein adsorption on the oscillating nanowires by 70% over nanowires oscillating in baseline viscosity fluid. Our preliminary studies strongly suggest that the architecture in the static nanowire arrays and the shear created by oscillating the nanowire arrays would attenuate the biofouling response in vivo.


Subject(s)
Magnetics , Nanostructures , Nanotechnology/methods , Proteins/chemistry , Adsorption , Animals , Cattle , Foreign-Body Reaction/prevention & control , In Vitro Techniques , Microscopy, Electron, Scanning , Prostheses and Implants/adverse effects , Serum Albumin, Bovine/chemistry , Surface Properties
18.
Biotechnol Prog ; 21(3): 926-32, 2005.
Article in English | MEDLINE | ID: mdl-15932275

ABSTRACT

Poly(ethylene) glycol (PEG) hydrogels have been successfully used to entrap mammalian cells for potential high throughput drug screening and biosensing applications. To determine the influence of PEG composition on the production of cellular protein, mammalian hepatocytes were maintained in PEG hydrogels for 7 days. Total cell viability, total protein production, and the production of two specific proteins, albumin and fibronectin, were monitored. Studies revealed that while PEG composition has no effect on cell viability, increasing amounts of PEG in the hydrogel decrease the amount of protein production by the cells after 7 days from 1.0 x 10(5) +/- 1.7 x 10(4) to 5.2 x 10(3) +/- 1.3 x 10(3) g accumulated protein/mL/million cells. Additionally, cells entrapped in PEG hydrogels produce greater amounts of protein than traditional monolayer culture (1.5 x 10(3) +/- 1.9 x 10(2) g accumulated protein/mL/million cells after 7 days). The addition of the synthetic peptide RGD to 10% PEG hydrogels altered the production of the proteins albumin and fibronectin. Hydrogels with the RGD sequence produced 287 +/- 27 ng/mL/million cells albumin after 7 days, an order of magnitude greater than monolayer cultures, whereas cells in hydrogels without the RGD sequence produced undetectable levels of albumin. Conversely, cells entrapped in 10% PEG hydrogels without the RGD sequence produced 1014 +/- 328 ng/mL/million cells fibronectin after 7 days, whereas 10% PEG hydrogels with the RGD sequence produced 200 +/- 58 ng/mL/million cells fibronectin after 7 days.


Subject(s)
Cell Culture Techniques/methods , Fibronectins/metabolism , Hepatocytes/cytology , Hepatocytes/physiology , Hydrogels/chemistry , Polyethylene Glycols/chemistry , Serum Albumin/metabolism , Animals , Biocompatible Materials/chemistry , Biological Assay/methods , Cell Line , Cell Survival/physiology , Gene Expression Profiling , Materials Testing , Mice
19.
Biotechnol Prog ; 21(3): 1004-7, 2005.
Article in English | MEDLINE | ID: mdl-15932288

ABSTRACT

Here we describe the fabrication and preservation of mammalian cell-containing hydrogel microarrays that have potential applications in drug screening and pathogen detection. Hydrogel microstructures containing murine fibroblasts were fabricated on silicon substrates and subjected to a "stage-down" freezing process. The percent viability of both immortal and primary embryonic murine fibroblast cells within the gels was determined at various stages in the freezing process, showing that cells entrapped in hydrogel microstructures remained viable throughout the process. When compared to immortalized adherent cultures subjected to the same freezing process, cells within hydrogel structures had higher cell viabilities at all stages during preservation. Finally, the necessity of using a cryoprotectant, dimethyl sulfoxide (DMSO), was investigated. Cells in hydrogels were cryopreserved with and without DMSO. The addition of DMSO altered cell viability after the freeze-thaw process, enhancing viability in an immortalized cell line and decreasing viability in a primary cell line.


Subject(s)
Biological Assay/methods , Cell Culture Techniques/methods , Cryopreservation/methods , Microarray Analysis/methods , Microfluidic Analytical Techniques/methods , Polyethylene Glycols/chemistry , 3T3 Cells , Animals , Biological Assay/instrumentation , Cell Culture Techniques/instrumentation , Cell Proliferation , Cell Survival , Cryopreservation/instrumentation , Equipment Design , Equipment Failure Analysis , Hydrogels/chemistry , Mice , Microarray Analysis/instrumentation , Microfluidic Analytical Techniques/instrumentation
20.
Biomed Microdevices ; 7(2): 117-25, 2005 Jun.
Article in English | MEDLINE | ID: mdl-15940424

ABSTRACT

In the area of drug discovery, high-speed synthesis has increased the number of drug candidates produced. These potential drugs need to be evaluated for their adsorption, distribution, metabolism, elimination, and toxicology (ADMET) properties as early in the drug development stage as possible. Previously, a potential drug's ADMET properties have been found out by using monolayer cell cultures and live animals. These methods can be costly, time-intensive, and impractical for screening the large amount of potential drugs created by combinatorial chemistry. A quick, small, inexpensive, and highly parallel device would be desirable to determine a drug candidate's properties (i.e., metabolism of the drug). Here we fabricate a microfluidic device entrapping human microsomes within poly(ethylene) glycol hydrogels thereby generating an in situ microreactor to assess a drug candidate's metabolic properties that can be coupled to analysis equipment. We show that microsomes can be entrapped without the loss of enzymatic activity during photopolymerization. Additionally, a microreactor utilizing hepatocytes was also created for comparison with the microsome microreactor.


Subject(s)
Biological Assay/instrumentation , Bioreactors , Flow Cytometry/instrumentation , Flow Injection Analysis/instrumentation , Hepatocytes/metabolism , Microfluidic Analytical Techniques/instrumentation , Microsomes/metabolism , Biological Assay/methods , Cell Culture Techniques/instrumentation , Cell Culture Techniques/methods , Cells, Cultured , Equipment Design , Equipment Failure Analysis , Flow Cytometry/methods , Flow Injection Analysis/methods , Hepatocytes/drug effects , Humans , Microfluidic Analytical Techniques/methods , Microsomes/drug effects , Miniaturization , Pharmaceutical Preparations/administration & dosage
SELECTION OF CITATIONS