Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Indian J Ophthalmol ; 70(11): 4000-4002, 2022 11.
Article in English | MEDLINE | ID: mdl-36308143

ABSTRACT

Purpose: To compare different endophthalmitis prophylaxis methods adopted in cataract surgery (manual small-incision cataract surgery and phacoemulsification) between the years 2013 and 2021 in the community eye care section of a tertiary eye care hospital in South India and report their outcomes. Methods: All cataract surgeries performed from January 2013 to December 2021 (2,46,874 surgeries) at a single center were included in this retrospective study. The different endophthalmitis rates with each regimen were analyzed and evaluated. Results: 70,081 surgeries were performed from January 2013 to February 2015, where Tobramycin was added to Balanced Salt Solution (BSS) (Group A). From March 2015 to January 2017, 63,245 surgeries were performed when intracameral Moxifloxacin was given (Group B). From February 2017 to December 2021, 1,13,548 surgeries were performed were Amikacin was added to BSS (Group C). In total, 42 cases of postoperative endophthalmitis were reported during the study period (0.02%). There was no significant difference in the endophthalmitis rates between groups A and B (P = 0.4152); however, there was a significant decrease in endophthalmitis rates in group C when compared with group A (P = 0.04) and group B (P = 0.006). Conclusion: There was a significant reduction in the rates of endophthalmitis following the addition of amikacin in irrigating BSS. Nocardia was one of the predominant organisms isolated from these endophthalmitis patients. This is the first single-center study to report a comparative analysis of different endophthalmitis prophylactic measures in a community eye care set up with a high incidence of Nocardia endophthalmitis prevented with amikacin in BSS irrigating solution.


Subject(s)
Cataract Extraction , Cataract , Endophthalmitis , Eye Infections, Bacterial , Humans , Retrospective Studies , Antibiotic Prophylaxis/methods , Eye Infections, Bacterial/epidemiology , Eye Infections, Bacterial/prevention & control , Eye Infections, Bacterial/etiology , Amikacin , Anti-Bacterial Agents/therapeutic use , Endophthalmitis/epidemiology , Endophthalmitis/etiology , Endophthalmitis/prevention & control , Cataract Extraction/adverse effects , Postoperative Complications/epidemiology , Postoperative Complications/prevention & control , Postoperative Complications/drug therapy , Cataract/complications
2.
Indian J Ophthalmol ; 69(7): 1766-1768, 2021 07.
Article in English | MEDLINE | ID: mdl-34146025

ABSTRACT

Purpose: To analyze the outcomes of phacoemulsification with high power customized toric intraocular lens implantation (IOL) in patients with high corneal astigmatism (6-10 D Cyl) post keratoplasty and keratoconus eyes with cataract. Methods: Five eyes post keratoplasty with clear graft, four eyes with stable keratoconus, one eye with pterygium excision scar with visually significant cataract were included in this retrospective study. Phacoemulsification was done followed by implantation of custom made high power toric IOL in all patients. Outcomes included uncorrected and best-corrected distance visual acuity (UDVA, BCVA), pre-operative astigmatism at the corneal plane and IOL plane, post-operative residual astigmatism, mean torus of all IOLs used were calculated. Results: The minimum follow-up time was 12 months. At the last follow-up visit, there was a significant improvement (pre-operative vs post-operative) of UDVA (1.5 ± 0.47 vs 0.28 ± 0.14 logMAR; P < 0.05), cylindrical refraction (-9.0 ± 1.80 D vs -1.1 ± 0.45 vs ; P < 0.05). Range of IOL powers used was 1.0-26.50 DSph and 9.0-15.5 DCyl. Post-operative mean residual spherical equivalent was 0.75 ± 0.5. Conclusion: This novel study describes the effectiveness of custom toric IOLs in high astigmatism in the range of 9.0-15.5 DCyl. Phacoemulsification with implantation of a customized high power toric IOL was effective in correcting high astigmatism in complex cases in our study.


Subject(s)
Astigmatism , Cataract , Corneal Transplantation , Keratoconus , Lenses, Intraocular , Phacoemulsification , Astigmatism/etiology , Astigmatism/surgery , Cataract/complications , Humans , Keratoconus/complications , Keratoconus/diagnosis , Keratoconus/surgery , Lens Implantation, Intraocular , Refraction, Ocular , Retrospective Studies , Visual Acuity
SELECTION OF CITATIONS
SEARCH DETAIL
...