Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 22
Filter
Add more filters










Publication year range
1.
Materials (Basel) ; 17(10)2024 May 08.
Article in English | MEDLINE | ID: mdl-38793287

ABSTRACT

We developed and analyzed a novel non-sparking material based on CuAlBe for applications in potentially explosive environments. Using a master alloy of CuBe, an established material for anti-sparking tools used in oil fields, mines, or areas with potentially explosive gas accumulations, and pure Al, we used an Ar atmosphere induction furnace to obtain an alloy with ~10 wt% Al and ~2 wt% Be percentages and good chemical and structural homogeneity. The new material was tested in an explosive gaseous mixture (10% H2 or 6.5% CH4) under extremely strong wear for 16,000 cycles, and no hot sparks capable of igniting the environment were produced. The material was used in the form of hot-rolled plates obtained from melted ingots. The experimental results reflect the use of a suitable material for non-sparking tools. This material has good deformability during hot rolling, abnormal grain growth during deformation under heat treatment and special thermo-mechanical processing, and no high chemical composition variation. Additionally, there are slightly different corrosion resistance and mechanical properties between the melt and hot-rolled state of CuAlBe material. Through hot rolling, the material's corrosion resistance increased, reducing the chances of generating sparks capable of causing explosions.

2.
Cells ; 11(24)2022 12 19.
Article in English | MEDLINE | ID: mdl-36552883

ABSTRACT

BACKGROUND: Bacterial biofilm formation (BBF) proves itself to be in the spotlight of microbiology research due to the wide variety of infections that it can be associated with, the involvement in food spoilage, industrial biofouling and perhaps sewage treatment. However, BBF remains difficult to study due to the lack of standardization of the existing methods and the expensive equipment needed. We aim to describe a new inexpensive and easy to reproduce protocol for a 3D-printed microfluidic device that can be used to study BBF in a dynamic manner. METHODS: We used the SolidWorks 3D CAD Software (EducationEdition 2019-2020, Dassault Systèmes, Vélizy-Villacoublay, France) to design the device and the Creality3D Ender 5 printer (Shenzhen Creality 3D Technology Co., Ltd., Shenzhen, China) for its manufacture. We cultivated strains of Enterococcus faecalis, Staphylococcus aureus, Klebsiella pneumoniae and Pseudomonas aeruginosa. For the biofilm evaluation we used optical coherence tomography (OCT), scanning electron microscopy (SEM), Fourier Transform Infrared (FTIR) spectroscopy and crystal violet staining technique. RESULTS: Based on the analysis, Enterococcus faecalis seems to produce more biofilm in the first hours while Pseudomonas aeruginosa started to take the lead on biofilm production after 24 h. CONCLUSIONS: With an estimated cost around €0.1285 for one microfluidic device, a relatively inexpensive and easy alternative for the study of BBF was developed.


Subject(s)
Bacteria , Staphylococcal Infections , Humans , Biofilms , Staphylococcus aureus , Microscopy, Electron, Scanning
3.
Medicina (Kaunas) ; 58(11)2022 Nov 03.
Article in English | MEDLINE | ID: mdl-36363548

ABSTRACT

Background and objectives: Cementless total hip arthroplasty is a common surgical procedure and perioperative thromboprophylaxis is used to prevent deep vein thrombosis or pulmonary embolism. Osseointegration is important for long-term implant survival, and there is no research on the effect of different thromboprophylaxis agents on the process of osseointegration. Materials and Methods: Seventy rats were allocated as follows: Group I (control group), Group II (enoxaparin), Group III (nadroparin), and Group IV (fondaparinux). Ovariectomy was performed on all subjects, followed by the introduction of an intramedullary titanium implant into the femur. Thromboprophylaxis was administered accordingly to each treatment group for 35 days postoperatively. Results: Group I had statistically significantly lower anti-Xa levels compared to treatment groups. Micro-CT analysis showed that nadroparin had lower values compared to control in bone volume (0.12 vs. 0.21, p = 0.01) and percent bone volume (1.46 vs. 1.93, p = 0.047). The pull-out test showed statistically significant differences between the control group (8.81 N) compared to enoxaparin, nadroparin, and fondaparinux groups (4.53 N, 4 N and 4.07 N, respectively). Nadroparin had a lower histological cortical bone tissue and a higher width of fibrous tissue (27.49 µm and 86.9 µm) at the peri-implant area, compared to control (43.2 µm and 39.2 µm), enoxaparin (39.6 µm and 24 µm), and fondaparinux (36.2 µm and 32.7 µm). Conclusions: Short-term administration of enoxaparin, nadroparin, and fondaparinux can reduce the osseointegration of titanium implants, with nadroparin having the most negative effect. These results show that enoxaparin and fondaparinux are preferred to be administered due to a lesser negative impact on the initial implant fixation.


Subject(s)
Nadroparin , Venous Thromboembolism , Female , Rats , Animals , Nadroparin/pharmacology , Nadroparin/therapeutic use , Fondaparinux , Enoxaparin/pharmacology , Enoxaparin/therapeutic use , Titanium/therapeutic use , Osseointegration , Factor X , Anticoagulants/pharmacology , Anticoagulants/therapeutic use , Venous Thromboembolism/drug therapy
4.
Micromachines (Basel) ; 13(9)2022 Aug 24.
Article in English | MEDLINE | ID: mdl-36144000

ABSTRACT

A realistic modelling of the way biofilms form and evolve in time requests a dynamic approach. In this study, the proposed route uses continuous-flow bioreactors under controlled flow rates and temperature in the culture medium containing bacteria or fungi. 3D printed, Polylactic acid (PLA), flow-based bioreactors with integrated copper electrodes were used to investigate the effect of dielectrophoresis on the formation and growth of Staphylococcus aureus ATCC 25923, Enterococcus faecalis ATCC 29212, Pseudomonas aeruginosa ATCC 27853, and Klebsiella pneumoniae ATCC 13883 biofilms. Bacterial suspensions of 1McF turbidity have been prepared and circulated through the bioreactors. At the same time, a 30 V potential difference was applied on the system. The effect of the non-uniform electric field induced upon the bacterial cells was determined using quantitative methods, such as an adjusted microtiter plate technique, as well as spectral domain optical coherence tomography (SD-OCT) images. The morphology and the surface quality of the biofilms were investigated using Scanning Electron Microscopy (SEM) images. The results show that the different bacterial cells present a positive dielectrophoretic behaviour, with the preferential formation of biofilms in the high field gradient region.

5.
Gels ; 8(8)2022 Aug 01.
Article in English | MEDLINE | ID: mdl-36005084

ABSTRACT

Dexamethasone is one of the most often used corticosteroid drugs for sensorineural hearing loss treatment, and is used either by intratympanic injection or through systemic delivery. In this study, a biopolymer lipid hybrid microcarrier was investigated for enhanced local drug delivery and sustained release at the round window membrane level of the middle ear for the treatment of sensorineural hearing loss (SNHL). Dexamethasone-loaded and dexamethasone-free microparticles were prepared using biopolymers (polysaccharide and protein, pectin and bovine serum albumin, respectively) combined with lipid components (phosphatidylcholine and Dimethyldioctadecylammonium bromide) in order to obtain a biopolymer-liposome hybrid system, with a complex structure combining to enhance performance in terms of physical and chemical stability. The structure of the microparticles was evaluated by FTIR, XRD, thermal analysis, optical microscopy, and scanning electron microscopy (SEM). The encapsulation efficiency determination and the in vitro Dexamethasone release study were performed using UV-Vis spectroscopy. The high value of encapsulation efficiency and the results of the release study indicated six days of sustained release, encouraging us to evaluate the in vitro cytotoxicity of Dexamethasone-loaded microparticles and their influence on the cytotoxicity induced by Cisplatin on auditory HEI-OC1 cells. The results show that the new particles are able to protect the inner ear sensory cells.

6.
Materials (Basel) ; 15(15)2022 Aug 08.
Article in English | MEDLINE | ID: mdl-35955381

ABSTRACT

This paper presents the usage of spark plasma sintering (SPS) as a method to obtain aluminum-expanded perlite syntactic foams with high porosity. In the test samples, fine aluminum powder with flaky shape particles was used as matrix material and natural, inorganic, granular, expanded perlite was used as a space holder to ensure high porosity (35−57%) and uniform structure. SPS was used to consolidate the specimens. The structures were characterized by scanning electron microscopy and compression tests. Energy absorption (W~7.49 MJ/m3) and energy absorption efficiency (EW < 90%) were also determined.

7.
Materials (Basel) ; 15(9)2022 Apr 22.
Article in English | MEDLINE | ID: mdl-35591388

ABSTRACT

This study presents the correct processing of Co-Cr alloys as a method of preserving the properties of the materials as-cast, and therefore they can be safely placed in contact with the oral cavity tissues as resistance frameworks. The basic materials analyzed in this study were five commercial Co-Cr dental alloys with different components obtained in three processing steps. The analysis of the electrochemical behavior at the surface of the Co-Cr alloys was performed by electrochemical measurements: impedance spectroscopy (EIS), open circuit electrical potential (OCP), and linear polarization (LP). In terms of validation, all five alloys had a tendency to generate a stable oxide layer at the surface. After the measurements and the graphical representation, the alloy that had a higher percentage of tungsten (W) and iron (Fe) in composition showed a higher tendency of anodizing. After the application of the heat treatment, the disappearance of the hexagonal phase was observed, with the appearance of new phases of type (A,B)2O3 corresponding to some oxide compounds, such as Fe2O3, Cr2O3, (Cr,Fe)2O3, and CoMnO3. In conclusion, the processing of Co-Cr alloys by melting and casting in refractory molds remains a viable method that can support innovation, in the context of technology advance in recent years towards digitalization of the manufacturing process, i.e., the construction of prosthetic frameworks conducted by additive methods using Co-Cr powder alloy.

8.
Materials (Basel) ; 14(21)2021 Oct 21.
Article in English | MEDLINE | ID: mdl-34771795

ABSTRACT

The orthodontic miniscrew (TADs) is a device that is fixed into bone in the short term for the purpose of enhancing orthodontic anchorage. The aim of our study was to investigate the structural and surface properties of recovered TADs after orthodontic treatment, and compare them to new TADs. TADs (n = 15) from the same manufacturer (Absoanchor; Dentos, Daegu, Korea) were assessed; n = 10 were recovered from patients after orthodontic treatment and n = 5 were new. We performed electrochemical investigations, scanning electron microscopy (SEM) and microbiological analysis. Qualitative analysis on general electrochemical polarization revealed that the TADs retrieved from the patients provided much lower current densities in the passivity zone, and the oxidative processes taking place on their surface were of lower intensity. The surface morphologies of the tips of the retrieved mini-implants showed less sharp tips and smooth surfaces. Defects in the form of pores or cracks could be identified in both evaluated TAD groups. All retrieved TADs showed signs of biological materials (SEM analysis) and contamination on their surfaces. In conclusion, these results can assist orthodontists in comprehending the complexities of TAD behavior with respect to their design and structure.

9.
Materials (Basel) ; 14(7)2021 Mar 31.
Article in English | MEDLINE | ID: mdl-33807480

ABSTRACT

This work proposes a novel complex multi-layered material consisting of porous titanium as a substrate and a complex coating consisting of a chitosan film engulfing microsphere loaded with growth factors such as BMP2 (bone morphogenic protein 2) and IGF1 (insulin-like growth factor-1). The microspheres were obtained through deposition of dual layers of calcium cross linked pectin-chitosan/pectin polyelectrolyte onto a BSA (bovine serum albumin) gel core. The multilayer was conceived to behave like a 3rd generation biomaterial, by slow delivery of viable growth factors around implants, and to assist the healing of implantation wound and the development of new vital bone. The biologic effect of the delivery of growth factors was studied in vitro, on MSC-CD1 mesenchymal stem cells, and in vivo, on CD1 mice. Proliferation and differentiation of cells were accelerated by growth factors, especially IGF1 for proliferation and BMP2 for differentiation. In vivo tests analyzed histologically and by MicroCT show a more structured tissue around BMP2 samples. The present concept will give the best clinical results if both growth factors are delivered together by a coating film that contains a double population of microcarriers.

10.
Materials (Basel) ; 14(3)2021 Jan 23.
Article in English | MEDLINE | ID: mdl-33498642

ABSTRACT

Cobalt-chromium (Co-Cr) alloys are the most widely used materials for removable and fixed dental prosthetic frameworks. The fitting accuracy between these components in dental prosthetic frameworks assembles (DPFAs) is largely influenced by the manufacturing method. This study presents a novel manufacturing method that combined two common techniques for obtaining one single framework: casting of Co-Cr inserts on top of parts previously manufactured by selective laser melting (SLM) of Co-Cr powder (CoM). Horizontal (n = 4) and vertical (n = 3) surfaces were microscopically analyzed (n = 770 count sum). The results revealed a high precision of the process and high fitting accuracy between the hybrid frameworks. The average distance measured between the frameworks in joined position was 41.08 ± 7.56 µm. In conclusion, the manufacturing of Co-Cr alloys DPFA using the CoM method reduced the deformation of hybrid frameworks and improved the joining accuracy between them.

11.
PLoS One ; 16(1): e0240462, 2021.
Article in English | MEDLINE | ID: mdl-33471789

ABSTRACT

The origins of money and the formulation of coherent weight and measurement systems are amongst the most significant prehistoric developments of the human intellect. We present a method for detecting perceptible standardization of weights and apply this to 5028 Early Bronze Age rings, ribs, and axe blades from Central Europe. We calculate the degree of uniformity on the basis of psychophysics, and quantify this using similarity indexes. The analysis shows that 70.3% of all rings could not be perceptibly distinguished from a ring weighing 195.5 grams, indicating their suitability as commodity money. Perceptive weight equivalence is demonstrated between rings, and a selection of ribs and axe blades. Co-occurrence of these objects evidences their interchangeability. We further suggest that producing copies of rings led to recognition of weight similarities and the independent emergence of a system of weighing in Central Europe at the end of the Early Bronze Age.


Subject(s)
Archaeology/methods , Commerce/history , Weights and Measures/history , Europe , History, Ancient , Humans , Weights and Measures/standards
12.
Materials (Basel) ; 13(18)2020 Sep 16.
Article in English | MEDLINE | ID: mdl-32948067

ABSTRACT

The demand of lattice structures for medical applications is increasing due to their ability to accelerate the osseointegration process, to reduce the implant weight and the stiffness. Selective laser melting (SLM) process offers the possibility to manufacture directly complex lattice applications, but there are a few studies that have focused on biocompatible Ti6Al7Nb alloy. The purpose of this work was to investigate the physical-mechanical properties and the microstructure of three dissimilar lattice structures that were SLM-manufactured by using Ti6Al7Nb powder. In particular, the strut morphology, the fracture characterization, the metallographic structure, and the X-ray phase identification were analyzed. Additionally, the Gibson-Ashby prediction model was adapted for each lattice topology, indicating the theoretical compressive strength and Young modulus. The resulted porosity of these lattice structures was approximately 56%, and the pore size ranged from 0.40 to 0.91 mm. Under quasi-static compression test, three failure modes were recorded. Compared to fully solid specimens, the actual lattice structures reduce the elastic modulus from 104 to 6-28 GPa. The struts surfaces were covered by a large amount of partial melted grains. Some solidification defects were recorded in struts structure. The fractographs revealed a brittle rupture of struts, and their microstructure was mainly α' martensite with columnar grains. The results demonstrate the suitability of manufacturing lattice structures made of Ti6Al7Nb powder having unique physical-mechanical properties which could meet the medical requirements.

13.
Int J Nanomedicine ; 14: 5799-5816, 2019.
Article in English | MEDLINE | ID: mdl-31440048

ABSTRACT

PURPOSE: Bone consolidation after severe trauma is the most challenging task in orthopedic surgery. This study aimed to develop biomimetic composite for coating Ti implants. Afterwards, these implants were tested in vivo to assess bone consolidation in the absence or the presence of high-frequency pulsed electromagnetic short-waves (HF-PESW). MATERIALS: Biomimetic coating was successfully developed using multi-substituted hydroxyapatite (ms-HAP) functionalized with collagen (ms-HAP/COL), embedded into poly-lactic acid (PLA) matrix (ms-HAP/COL@PLA), and subsequently covered with self-assembled COL layer (ms-HAP/COL@PLA/COL, named HAPc). METHODS: For in vivo evaluation, 32 Wistar albino rats were used in four groups: control group (CG) with Ti implant; PESW group with Ti implant+HF-PESW; HAPc group with Ti implant coated with HAPc; HAPc+PESW group with Ti implant coated with HAPc+HF-PESW. Left femoral diaphysis was fractured and fixed intramedullary. From the first post-operative day, PESW and HAPc+PESW groups underwent HF-PESW stimulation for 14 consecutive days. Biomimetic coating was characterized by XRD, HR-TEM, SEM, EDX and AFM. RESULTS: Osteogenic markers (ALP and osteocalcin) and micro-computed tomography (CT) analysis (especially bone volume/tissue volume ratio results) indicated at 2 weeks the following group order: HAPc+PESW>HAPc≈PESW (P>0.05) and HAPc+PESW>control (P<0.05), indicating the higher values in HAPc+PESW group compared to CG. The fracture-site bone strength showed, at 2 weeks, the highest average value in HAPc+PESW group. Moreover, histological analysis revealed the most abundant COL fibers assembled in dense bundles in HAPc-PESW group. At 8 weeks, micro-CT indicated higher values only in HAPc+PESW group vs CG (P<0.05), and histological results showed a complete-healed fracture in groups: HAPc+PESW, HAPc and PESW, but with more advanced bone remodeling in HAPc+PESW group. CONCLUSION: Using Ti implants coated by HAPc jointly with HF-PESW stimulation positively influenced the bone consolidation process, especially in its early phase, thus potentially providing a superior strategy for clinical applications.


Subject(s)
Biomimetic Materials/pharmacology , Bone and Bones/drug effects , Coated Materials, Biocompatible/pharmacology , Electromagnetic Phenomena , Polyesters/chemistry , Prostheses and Implants , Titanium/pharmacology , Animals , Biomarkers/blood , Biomechanical Phenomena , Cattle , Collagen/pharmacology , Durapatite/pharmacology , Femur/drug effects , Osteogenesis/drug effects , Rats, Wistar , Surface Properties , X-Ray Microtomography
14.
Bosn J Basic Med Sci ; 19(2): 201-209, 2019 May 20.
Article in English | MEDLINE | ID: mdl-30794499

ABSTRACT

In vitro studies showed that high-frequency pulsed electromagnetic fields (HF-PEMFs) increase the activity/expression of early and late osteogenic markers and enhance bone mineralization. The main aim of this study was to investigate the in vivo effects of HF-PEMFs on fracture healing using a rat model. A femur fracture was established by surgery in 20 male Wistar rats. Titanium nails were implanted to reduce and stabilize the fracture. After surgery, 20 rats were equally divided into untreated control and treated group (from the first postoperative day HF-PEMFs at 400 pulses/sec [pps] were applied for 10 minutes/day, for two weeks). Quantitative and qualitative assessment of bone formation was made at two and eight weeks following surgery and included morphological and histological analysis, serological analysis by ELISA, micro-computed tomography (micro-CT), and three-point bending test. At two weeks in HF-PEMF group, soft callus was at a more advanced fibrocartilaginous stage and the bone volume/total tissue volume (BV/TV) ratio in the callus area was significantly higher compared to control group (p = 0.047). Serum concentration of alkaline phosphatase (ALP) and osteocalcin (OC) was significantly higher in HF-PEMF group (ALP p = 0.026, OC p = 0.006) as well as the mechanical strength of femurs (p = 0.03). At eight weeks, femurs from HF-PEMF group had a completely formed woven bone with dense trabeculae, active bone marrow, and had a significantly higher BV/TV ratio compared to control (p = 0.01). HF-PEMFs applied from the first postoperative day, 10 minutes/day for two weeks, enhance bone consolidation in rats, especially in the early phase of fracture healing.


Subject(s)
Bone and Bones/physiology , Calcification, Physiologic , Electromagnetic Fields , Femoral Fractures/therapy , Fracture Healing , Animals , Enzyme-Linked Immunosorbent Assay , Fibrocartilage , Male , Osteoblasts , Osteocalcin/metabolism , Osteogenesis , Postoperative Period , Rats , Rats, Wistar , X-Ray Microtomography
15.
J Archaeol Method Theory ; 23(4): 1285-1306, 2016.
Article in English | MEDLINE | ID: mdl-29368750

ABSTRACT

The paper introduces a method that links environment to landscape. The environment-landscape divide appears because of epistemological differences: since studying the landscape involves describing the world as it was perceived by humans, it is difficult to access this dimension through the numerical data that we employ when studying the environment. We approach the issue of non-correspondence between environment and landscape knowledge using fuzzy logic. The numerical data describing two geomorphometric parameters, slope and modified topographic index, are split each into three classes with overlapping borders. The classes are then fused into four qualitative categories: flat wet, steep dry, flat dry, and gradual moist. These four categories have direct correspondence in the real world and can be observed by people through simple perception. The correspondence of such categories to peoples' perception is checked against evidence of past human settlement in three areas coming from Turkey, Serbia, and Syria. The identified qualitative categories resemble the way people categorized their landscape in all but the second case study. Humans were able to perceive and choose areas which correspond to gradual moist in Turkey and broadly to flat wet in Syria. However, for the Serbian example, the results are inconclusive.

16.
BMC Biotechnol ; 15: 114, 2015 Dec 30.
Article in English | MEDLINE | ID: mdl-26718927

ABSTRACT

BACKGROUND: We aimed to demonstrate that DF stem cells from impacted molars and canines can be used to improve bone regeneration on titanium implants surfaces. This study highlights the presence of stem cells in DF, their potential to adhere and differentiate into osteoblasts on different types of titanium surfaces. RESULTS: Isolated cells from the harvested DF tissue from impacted canine/molars, expressed stem cells markers. Differentiation into bone cells was induced in presence or absence of BMP-2 and TGFß1. The presence of growth factors until 28 days in medium maintained the cells in an earlier stage of differentiation with a lower level of specific bone proteins and a higher expression of alkaline phosphatase (ALP). Influence of titanium implants with different bioactive coatings, hydroxyapatite (TiHA) and with silicatitanate (TiSiO2), and porous Ti6Al7Nb implants as control (TiCtrl), was studied in terms of cell adhesion and viability. Ti HA implants proved to be more favorable for adhesion and proliferation of DF stem cells in first days of cultivation. The influence of titanium coatings and osteogenic differentiation mediums with or without growth factors were evaluated. Additional BMP-2 in the medium did not allow DF stem cells to develop a more mature phenotype, leaving them in a pre-osteogenic stage. The best sustained mineralization process evaluated by immuno-cytochemical staining, scanning electron microscopy and Ca(2+) quantification was observed for TiHA implants with a higher expression of ALP, collagen and Ca(2+) deposition. Long term culturing (70 days) on titanium surfaces of DF stem cells in standard medium without soluble osteogenic inducers, indicated that HA coating is more favorable, with the acquisition of a more mature osteoblastic phenotype as shown by immunocytochemical staining. These findings demonstrated that even in absence of exogenous osteogenic factors, TiHA implants and in a lesser extent TiCtrl and TiSiO2 implants can induce and sustain osteogenic differentiation of DF stem cells, by their chemical and topographical properties. CONCLUSIONS: Our research demonstrated that DF stem cells have a spontaneous tendency for osteogenic differentiation and can be used for improving bone regeneration on titanium implants surfaces.


Subject(s)
Bone Regeneration/physiology , Dental Implants , Dental Sac/cytology , Stem Cells/cytology , Titanium , Adolescent , Adult , Alkaline Phosphatase/metabolism , Cell Differentiation/physiology , Cells, Cultured , Coated Materials, Biocompatible/chemistry , Coated Materials, Biocompatible/metabolism , Cuspid/cytology , Durapatite/chemistry , Female , Humans , Mesenchymal Stem Cells/cytology , Molar/cytology , Osteoblasts/cytology , Osteoblasts/physiology , Osteogenesis , Young Adult
17.
J Biol Eng ; 8: 14, 2014.
Article in English | MEDLINE | ID: mdl-24987458

ABSTRACT

BACKGROUND: The development of novel biomaterials able to control cell activities and direct their fate is warranted for engineering functional bone tissues. Adding bioactive materials can improve new bone formation and better osseointegration. Three types of titanium (Ti) implants were tested for in vitro biocompatibility in this comparative study: Ti6Al7Nb implants with 25% total porosity used as controls, implants infiltrated using a sol-gel method with hydroxyapatite (Ti HA) and silicatitanate (Ti SiO2). The behavior of human osteoblasts was observed in terms of adhesion, cell growth and differentiation. RESULTS: The two coating methods have provided different morphological and chemical properties (SEM and EDX analysis). Cell attachment in the first hour was slower on the Ti HA scaffolds when compared to Ti SiO2 and porous uncoated Ti implants. The Alamar blue test and the assessment of total protein content uncovered a peak of metabolic activity at day 8-9 with an advantage for Ti SiO2 implants. Osteoblast differentiation and de novo mineralization, evaluated by osteopontin (OP) expression (ELISA and immnocytochemistry), alkaline phosphatase (ALP) activity, calcium deposition (alizarin red), collagen synthesis (SIRCOL test and immnocytochemical staining) and osteocalcin (OC) expression, highlighted the higher osteoconductive ability of Ti HA implants. Higher soluble collagen levels were found for cells cultured in simple osteogenic differentiation medium on control Ti and Ti SiO2 implants. Osteocalcin (OC), a marker of terminal osteoblastic differentiation, was most strongly expressed in osteoblasts cultivated on Ti SiO2 implants. CONCLUSIONS: The behavior of osteoblasts depends on the type of implant and culture conditions. Ti SiO2 scaffolds sustain osteoblast adhesion and promote differentiation with increased collagen and non-collagenic proteins (OP and OC) production. Ti HA implants have a lower ability to induce cell adhesion and proliferation but an increased capacity to induce early mineralization. Addition of growth factors BMP-2 and TGFß1 in differentiation medium did not improve the mineralization process. Both types of infiltrates have their advantages and limitations, which can be exploited depending on local conditions of bone lesions that have to be repaired. These limitations can also be offset through methods of functionalization with biomolecules involved in osteogenesis.

18.
Article in English | MEDLINE | ID: mdl-22587390

ABSTRACT

This study deals with recent researches undertaken by the authors in the field of hydrodynamics of human swimming. The aim of this numerical study was to investigate the flow around the entire swimmer's body. The results presented in this article focus on the combination of a 3D computational fluid dynamics code and the use of the k-ω turbulence model, in the range of Reynolds numbers representative of a swimming level varying from national to international competition. Emphasis is placed on the influence of a postural change of the swimmer's head in hydrodynamic performances, which is directly related to the reduction of overall drag. These results confirm and complete those, less accurate, of a preliminary 2D study recently published by the authors and allow the authors to optimise the swimmer's head position in underwater swimming.


Subject(s)
Posture/physiology , Swimming/physiology , Computer Simulation , Head , Humans , Hydrodynamics , Models, Biological , Rheology/methods
19.
J Biomater Appl ; 27(6): 707-16, 2013 Feb.
Article in English | MEDLINE | ID: mdl-22071352

ABSTRACT

Novel composite scaffolds were produced using long continuous bidirectional fibers embedded in an electrospun matrix, with the aim of using them in soft tissue engineering applications. The fibers are of polydioxanone and the matrix of polylactic acid. The novel manufacturing method consists of direct electrospinning performed on both sides of a collector that supports the already arranged fibers. The scaffolds were tested in vitro using 3T3 mouse fibroblasts as-obtained or functionalized with biotin or poly (dopamine). Functionalization did not significantly affect cells attachment, metabolic activity, or proliferation, but poly (dopamine) was proven to be effective in inducing hydrophilicity to the surface.


Subject(s)
Lactic Acid/chemistry , Polydioxanone/chemistry , Polymers/chemistry , Tissue Engineering/methods , Tissue Scaffolds/chemistry , 3T3 Cells , Animals , Biocompatible Materials/chemistry , Calorimetry, Differential Scanning , Cell Adhesion , Cell Proliferation , Fibroblasts/cytology , Fibroblasts/metabolism , Materials Testing , Mice , Microscopy, Electron, Scanning , Polyesters , Spectroscopy, Fourier Transform Infrared , Tensile Strength , Tissue Engineering/instrumentation , X-Ray Diffraction
20.
Ann Ital Chir ; 83(1): 75-8, 2012.
Article in English | MEDLINE | ID: mdl-22352223

ABSTRACT

Vermiform appendix torsion is rare, and even more uncommon is the volvulus of appendiceal mucinous tumors. To our knowledge, only nine cases of torsion of the vermiform appendix associated with appendiceal mucinous neoplasms have been reported up to date. We report a case of secondary torsion of the vermiform appendix with mucinous cystadenoma in a 30-year-old man. The symptoms were consistent with acute appendicitis. Diagnostic laparoscopy revealed a mucinous tumor of the appendix with a 360 degrees twisted appendix. In order to avoid peritoneal dissemination open appendectomy was performed. The final pathologic diagnosis was a mucinous cystadenoma of the appendix. The postoperative recovery was uneventful. Secondary torsion of vermiform appendix with mucinous cystadenoma is a rare entity. Correct preoperative diagnosis is unlikely. Open appendectomy is the standard of care for benign mucinous appendiceal tumors. Furthermore, it is important to prevent spillage of the appendiceal mucocele content.


Subject(s)
Appendiceal Neoplasms/diagnosis , Cystadenoma, Mucinous/diagnosis , Torsion Abnormality/diagnosis , Adult , Appendectomy , Appendiceal Neoplasms/pathology , Appendiceal Neoplasms/surgery , Cystadenoma, Mucinous/pathology , Cystadenoma, Mucinous/surgery , Diagnosis, Differential , Humans , Male , Torsion Abnormality/pathology , Torsion Abnormality/surgery , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...