Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Endovasc Ther ; : 15266028241270895, 2024 Aug 26.
Article in English | MEDLINE | ID: mdl-39183689

ABSTRACT

OBJECTIVE: The main objective of this paper is to analyze the outcomes regarding endoleaks, reinterventions, and death related to aneurysm complications in patients submitted to endovascular repair (EVAR) for abdominal aortoiliac aneurysm (AAA) using Endurant II (Medtronic) and Zenith Flex (Cook) endografts. METHODS: This was a prospective, consecutive cohort study of patients with AAA who underwent EVAR between January 2019 and December 2022. Two groups of patients were evaluated: Group Endurant (patients submitted to EVAR with the use of Endurant II) and Group Zenith (patients submitted to EVAR with the use of Zenith Flex). RESULTS: A total of 156 patients were evaluated. Group Zenith (67 patients, 42.9%) and Group Endurant (89 patients, 57.1%). The perioperative mortality was 5.1%, eight patients (six patients Group Zenith, and two patients Group Endurant, p=0.054). There were 28 patients (17.9%) submitted to urgent repair of the aneurysm (expansion or rupture), with no differences among the groups. There were 36 cases (23.1%) of later endoleak, with a higher incidence in Zenith group (23 patients, 34.3%) than Endurant group (13 patients, 14.6%, p=0.002), most of them Type II endoleak (21 patients, 13.4%). There were 12 cases of Type I endoleak, also with a higher prevalence in Zenith group (13.4%) than Endurant group (3.4%, p=0.002). Moreover, regarding limb graft occlusion (LGO), there were nine patients (5.8%), with a higher prevalence in Zenith group (9%) than Endurant group (3.4%, p=0.045). The overall survival in a Kaplan-Meier at 720 days was 82.3% in the Zenith group and 89.1% in the Endurant group, with no statistical significance among the groups (p=0.09). The freedom from reintervention rates in a Kaplan-Meier at 720 days was 82.8% in the Zenith group and 93.2% in the Endurant group (p=0.001). CONCLUSION: In this present study, Zenith endograft had higher rates of endoleaks, aneurysms related mortality, LGO and reinterventions than patients submitted to Endurant II endografts. The linear regression analysis showed that the presence of endoleaks, type of endograft device (Zenith graft) and limb graft occlusion were related to higher reintervention rates. CLINICAL IMPACT: In this present study, Zenith endograft had higher rates of endoleaks, aneurysms related mortality, limb graft occlusions and reinterventions than patients submitted to Endurant II endografts. The main impact and the innovation that this article provides is an opportunity to evaluate and choose the best endograft suitable for the patient with AAA during EVAR.

2.
Vascular ; : 17085381241237559, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38429875

ABSTRACT

OBJECTIVE: The main objective of this present paper was to evaluate the results and outcomes of patients with acute limb ischemia (ALI) submitted to pharmacomechanical thrombectomy (PMT) endovascular surgery with Angiojet, regarding the number of cycles/pumps. METHODS: Prospective, consecutive cohort study of ALI patients submitted to PMT endovascular intervention subdivided into two groups according to the number of cycles in the Angiojet technique: Group 1 higher than 150 cycles/second and Group 2 lesser than 150 cycles/second (cycles/s). RESULTS: Overall, 92 patients with ALI submitted to PMT were evaluated. Two groups of patients were identified: Group 1 higher than 150 cycles/s with 60 patients and Group 2 lesser than 150 cycles/s with 32 patients. The overall mortality rate (OMR) was 15.1% (13 patients) in total cohort within the first 30 days. Group 1 had a higher OMR than Group 2 (16.1% vs 9.3%, p = 0.007). There were 4 cases of hematuria (4.3%), all of them in Group 1. We have performed a Kaplan-Meier regarding limb salvage rates: Group 1 had 85% and Group 2 had 95.7% at 1057 days. P = 0.081. Among the factors evaluated, the following were related to overall mortality rate: PMT with higher >150 cycles/s (HR = 7.17, p = 0.007, CI: 1.38-8.89), COVID-19 infection (HR = 2.75, p = 0.010, CI = 1.73-5.97), and post-operative acute kidney injury (HR = 2.97, p < 0.001, CI = 1.32-8.13). Among the factors evaluated, the following was related to limb loss: post-operative acute kidney injury (HR = 4.41, p = 0.036, CI: 1.771-7.132), probably because patients experiencing limb loss have a higher incidence of acute renal insufficiency due to higher circulating myoglobin higher hemolysis from the increased Angiojet cycles inducing rhabdomyolysis. CONCLUSION: PMT with Angiojet is a safe and effective therapy in patients with ALI. However, patients receiving greater than 150 cycles/s were noted to have higher rates of acute kidney injury and mortality. This is likely reflective of increased thrombus burden and higher rates of hemolysis. Acute kidney injury, greater than 150 cycles/s, and COVID-19 infection were the variables with the strongest association to perioperative mortality.

SELECTION OF CITATIONS
SEARCH DETAIL