1.
Am J Cardiol ; 114(8): 1249-56, 2014 Oct 15.
Article in English | MEDLINE | ID: mdl-25150135

ABSTRACT

Detect Fluid Early from Intrathoracic Impedance Monitoring (DEFEAT-PE) is a prospective, multicenter study of multiple intrathoracic impedance vectors to detect pulmonary congestion (PC) events. Changes in intrathoracic impedance between the right ventricular (RV) coil and device can (RVcoil→Can) of implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy ICDs (CRT-Ds) are used clinically for the detection of PC events, but other impedance vectors and algorithms have not been studied prospectively. An initial 75-patient study was used to derive optimal impedance vectors to detect PC events, with 2 vector combinations selected for prospective analysis in DEFEAT-PE (ICD vectors: RVring→Can + RVcoil→Can, detection threshold 13 days; CRT-D vectors: left ventricular ring→Can + RVcoil→Can, detection threshold 14 days). Impedance changes were considered true positive if detected <30 days before an adjudicated PC event. One hundred sixty-two patients were enrolled (80 with ICDs and 82 with CRT-Ds), all with ≥1 previous PC event. One hundred forty-four patients provided study data, with 214 patient-years of follow-up and 139 PC events. Sensitivity for PC events of the prespecified algorithms was as follows: ICD: sensitivity 32.3%, false-positive rate 1.28 per patient-year; CRT-D: sensitivity 32.4%, false-positive rate 1.66 per patient-year. An alternative algorithm, ultimately approved by the US Food and Drug Administration (RVring→Can + RVcoil→Can, detection threshold 14 days), resulted in (for all patients) sensitivity of 21.6% and a false-positive rate of 0.9 per patient-year. The CRT-D thoracic impedance vector algorithm selected in the derivation study was not superior to the ICD algorithm RVring→Can + RVcoil→Can when studied prospectively. In conclusion, to achieve an acceptably low false-positive rate, the intrathoracic impedance algorithms studied in DEFEAT-PE resulted in low sensitivity for the prediction of heart failure events.


Subject(s)
Cardiography, Impedance/instrumentation , Heart Failure/diagnosis , Pulmonary Edema/diagnosis , Aged , Algorithms , Cardiac Resynchronization Therapy , Electric Impedance , Equipment Design , Feasibility Studies , Female , Follow-Up Studies , Heart Failure/complications , Heart Failure/therapy , Heart Ventricles/physiopathology , Humans , Incidence , Male , Middle Aged , Prospective Studies , Pulmonary Edema/epidemiology , Pulmonary Edema/etiology , Reproducibility of Results , United States/epidemiology
2.
J Interv Card Electrophysiol ; 35(2): 197-206, 2012 Nov.
Article in English | MEDLINE | ID: mdl-22688951

ABSTRACT

PURPOSE: Pulmonary edema (PE) is associated with fluid accumulation in the lungs. Device-based impedance measurements have been used to detect fluid overload prior to hospitalization. However, studies have reported a high false positive rate (FPR). The objective of this study was to develop and test a new multivector impedance-based algorithm that reliably tracks PE clinical events. METHODS: We enrolled patients with implanted CRT-Ds in 23 US centers within 2 weeks of device implant. Six-vector impedance data was collected automatically by the CRT-Ds every 30 min during emergency department visits/hospitalizations and every 2 h at all other times. Detection algorithms for cardiac resynchronization therapy defibrillator (CRT-D) and implantable cardiac defibrillator (ICD) devices were developed using those impedance vectors that would be available in corresponding devices and retrospectively evaluated. RESULTS: There were 75 patients (69 % male), mean age 66 ± 12 years, with a LVEF of 23 ± 6 % and QRS of 149 ± 25 ms. Twenty-one major clinical events occurred over 8.2 ± 2.6 months of follow-up time. CRT-D vector combinations resulted in a sensitivity of 71.4 % (95 % confidence interval 47.8-88.7) and a FPR of 0.56 (0.30-0.94) false positives per patient-year (FPs/pt-yr); ICD vector combinations resulted in a sensitivity of 61.9 % (38.4-81.9) and a FPR of 0.63 (0.36-0.90) FPs/pt-yr. In comparison, the single-vector RVCoil-Can implementation of this algorithm resulted in a sensitivity of 57.1 % (34.0-78.2) and a FPR of 0.74 (0.44-1.12) FPs/pt-yr. CONCLUSIONS: This multivector impedance algorithm was effective in tracking PE clinical events in this patient population. Additional studies are needed to prospectively evaluate the performance of this algorithm in a larger population.


Subject(s)
Algorithms , Cardiac Resynchronization Therapy , Cardiography, Impedance , Heart Failure/complications , Heart Failure/surgery , Pulmonary Edema/diagnosis , Pulmonary Edema/etiology , Aged , Electric Impedance , Feasibility Studies , Female , Humans , Male , Retrospective Studies , United States
3.
J Cardiovasc Electrophysiol ; 21(5): 551-6, 2010 May.
Article in English | MEDLINE | ID: mdl-19925609

ABSTRACT

OBJECTIVE: The purpose of this large multicenter study was to evaluate the long-term reliability of an implantable cardioverter defibrillator (ICD) lead to determine the incidence of adverse events (AEs). BACKGROUND: A recent concern has been the performance of cardiac defibrillator leads. There have been conflicting reports regarding the rate of lead perforation and other AEs. METHODS: Medical records from patients implanted from 6-1-2001 to 11-27-2007 with the St. Jude Medical Riata family of RV leads at 23 US (N = 12,969) and 5 German (N = 2,418) centers were reviewed for chronic lead-related AEs. These included perforation, dislodgment, conductor fracture and insulation damage. The mean follow-up period was 18.0 months. AEs were defined as those that required Riata lead revision, extraction, or replacement. RESULTS: The incidence of lead AEs was <1% for each AE type. Perforation occurred in 0.38%, dislodgement in 0.93%, conductor fracture in 0.18%, and insulation damage in 0.21% of patients studied. CONCLUSIONS: During the follow-up of the 15,387 patients with Riata leads, the incidence of AEs which included perforation, dislodgement, conductor fraction and insulation damage was low and within the range of what is considered clinically acceptable.


Subject(s)
Arrhythmias, Cardiac/therapy , Defibrillators, Implantable , Aged , Arrhythmias, Cardiac/mortality , Defibrillators, Implantable/adverse effects , Equipment Design , Equipment Failure , Female , Follow-Up Studies , Heart Injuries/epidemiology , Heart Injuries/etiology , Humans , Male , Middle Aged , Monitoring, Physiologic , Prosthesis Implantation , Reoperation , Retrospective Studies , Time Factors