Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
Add more filters










Publication year range
1.
Comput Biol Med ; 173: 108334, 2024 May.
Article in English | MEDLINE | ID: mdl-38520919

ABSTRACT

Hypoxia contributes significantly to resistance in radiotherapy. Our research rigorously examines the influence of microvascular morphology on radiotherapy outcome, specifically focusing on how microvasculature shapes hypoxia within the microenvironment and affects resistance to a standard treatment regimen (30×2GyRBE). Our computational modeling extends to the effects of different radiation sources. For photons and protons, our analysis establishes a clear correlation between hypoxic volume distribution and treatment effectiveness, with vascular density and regularity playing a crucial role in treatment success. On the contrary, carbon ions exhibit distinct effectiveness, even in areas of intense hypoxia and poor vascularization. This finding points to the potential of carbon-based hadron therapy in overcoming hypoxia-induced resistance to RT. Considering that the spatial scale analyzed in this study is closely aligned with that of imaging data voxels, we also address the implications of these findings in a clinical context envisioning the possibility of detecting subvoxel hypoxia.


Subject(s)
Hypoxia , Photons , Humans , Photons/therapeutic use , Carbon
2.
PeerJ ; 11: e16208, 2023.
Article in English | MEDLINE | ID: mdl-37842042

ABSTRACT

Since the industrial revolution, oceans have become substantially noisier. The noise increase is mainly caused by increased shipping, resource exploration, and infrastructure development affecting marine life at multiple levels, including behavior and physiology. Together with increasing anthropogenic noise, climate change is altering the thermal structure of the oceans, which in turn might affect noise propagation. During this century, we are witnessing an increase in seawater temperature and a decrease in ocean pH. Ocean acidification will decrease sound absorption at low frequencies (<10 kHz), enhancing long-range sound propagation. At the same time, temperature changes can modify the sound speed profile, leading to the creation or disappearance of sound ducts in which sound can propagate over large distances. The worldwide effect of climate change was explored for the winter and summer seasons using the (2018 to 2022) and (2094 to 2098, projected) atmospheric and seawater temperature, salinity, pH and wind speed as input. Using numerical modelling, we here explore the impact of climate change on underwater sound propagation. The future climate variables were taken from a Community Earth System Model v2 (CESM2) simulations forced under the concentration-driven SSP2-4.5 and SSP5-8.5 scenarios. The sound modeling results show, for future climate change scenarios, a global increase of sound speed at different depths (5, 125, 300, and 640 m) except for the North Atlantic Ocean and the Norwegian Sea, where in the upper 125 m sound speed will decrease by as much as 40 m s-1. This decrease in sound speed results in a new sub-surface duct in the upper 200 m of the water column allowing ship noise to propagate over large distances (>500 km). In the case of the Northeast Atlantic Ocean, this sub-surface duct will only be present during winter, leading to similar total mean square pressure level (SPLtot) values in the summer for both (2018 to 2022) and (2094 to 2098). We observed a strong and similar correlation for the two climate change scenarios, with an increase of the top 200 m SPLtot and a slowdown of Atlantic Meridional Overturning Circulation (AMOC) leading to an increase of SPLtot at the end of the century by 7 dB.


Subject(s)
Climate Change , Seawater , Seawater/chemistry , Hydrogen-Ion Concentration , Oceans and Seas , Temperature
3.
Bioeng Transl Med ; 8(5): e10557, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37693050

ABSTRACT

Three-dimensional (3D) imaging techniques (e.g., confocal microscopy) are commonly used to visualize in vitro models, especially microvasculature on-a-chip. Conversely, 3D analysis is not the standard method to extract quantitative information from those models. We developed the µVES algorithm to analyze vascularized in vitro models leveraging 3D data. It computes morphological parameters (geometry, diameter, length, tortuosity, eccentricity) and intravascular flow velocity. µVES application to microfluidic vascularized in vitro models shows that they successfully replicate functional features of the microvasculature in vivo in terms of intravascular fluid flow velocity. However, wall shear stress is lower compared to in vivo references. The morphological analysis also highlights the model's physiological similarities (vessel length and tortuosity) and shortcomings (vessel radius and surface-over-volume ratio). The addition of the third dimension in our analysis produced significant differences in the metrics assessed compared to 2D estimations. It enabled the computation of new indices, such as vessel eccentricity. These µVES capabilities can find application in analyses of different in vitro vascular models, as well as in vivo and ex vivo microvasculature.

4.
Int J Numer Method Biomed Eng ; 39(11): e3752, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37455669

ABSTRACT

The vascular microenvironment is the scale at which microvascular transport, interstitial tissue properties and cell metabolism interact. The vascular microenvironment has been widely studied by means of quantitative approaches, including multi-physics mathematical models as it is a central system for the pathophysiology of many diseases, such as cancer. The microvascular architecture is a key factor for fluid balance and mass transfer in the vascular microenvironment, together with the physical parameters characterizing the vascular wall and the interstitial tissue. The scientific literature of this field has witnessed a long debate about which factor of this multifaceted system is the most relevant. The purpose of this work is to combine the interpretative power of an advanced multi-physics model of the vascular microenvironment with state of the art and robust sensitivity analysis methods, in order to determine the factors that most significantly impact quantities of interest, related in particular to cancer treatment. We are particularly interested in comparing the factors related to the microvascular architecture with the ones affecting the physics of microvascular transport. Ultimately, this work will provide further insight into how the vascular microenvironment affects cancer therapies, such as chemotherapy, radiotherapy or immunotherapy.


Subject(s)
Neoplasms , Humans , Neoplasms/therapy , Models, Theoretical , Physics , Tumor Microenvironment
5.
Front Physiol ; 14: 1070474, 2023.
Article in English | MEDLINE | ID: mdl-37008002

ABSTRACT

Introduction: Developing techniques for the tagless isolation of homogeneous cell populations in physiological-like conditions is of great interest in medical research. A particular case is Gravitational Field-Flow Fractionation (GrFFF), which can be run avoiding cell fixation, and that was already used to separate viable cells. Cell dimensions have a key role in this process. However, their dimensions under physiological-like conditions are not easily known since the most diffused measurement techniques are performed on fixed cells, and the fixation used to preserve tissues can alter the cell size. This work aims to obtain and compare cell size data under physiological-like conditions and in the presence of a fixative. Methods: We developed a new protocol that allows the analysis of blood cells in different conditions. Then, we applied it to obtain a dataset of human cord blood cell dimensions from 32 subjects, comparing two tubes with anticoagulants (EDTA and Citrate) and two tubes with different preservatives (CellRescue and CellSave). We analyzed a total of 2071 cells by using confocal microscopy via bio-imaging to assess dimensions (cellular and nuclear) and morphology. Results: Cell diameter measured does not differ when using the different anticoagulants, except for the increase reported for monocyte in the presence of citrate. Instead, cell dimensions differ when comparing anticoagulants and cell preservative tubes, with a few exceptions. Cells characterized by high cytoplasm content show a reduction in their size, while morphology appears always preserved. In a subgroup of cells, 3D reconstruction was performed. Cell and nucleus volumes were estimated using different methods (specific 3D tool or reconstruction from 2D projection). Discussion: We found that some cell types benefit from a complete 3D analysis because they contain non-spherical structures (mainly for cells characterized by poly-lobated nucleus). Overall, we showed the effect of the preservatives mixture on cell dimensions. Such an effect must be considered when dealing with problems highly dependent on cell size, such as GrFFF. Additionally, such information is crucial in computational models increasingly being employed to simulate biological events.

6.
Ann Biomed Eng ; 49(12): 3356-3373, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34184146

ABSTRACT

We address a mathematical model for oxygen transfer in the microcirculation. The model includes blood flow and hematocrit transport coupled with the interstitial flow, oxygen transport in the blood and the tissue, including capillary-tissue exchange effects. Moreover, the model is suited to handle arbitrarily complex vascular geometries. The purpose of this study is the validation of the model with respect to classical solutions and the further demonstration of its adequacy to describe the heterogeneity of oxygenation in the tissue microenvironment. Finally, we discuss the importance of these effects in the treatment of cancer using radiotherapy.


Subject(s)
Blood Flow Velocity/physiology , Microcirculation/physiology , Models, Cardiovascular , Oxygen Consumption/physiology , Computer Simulation , Hematocrit , Humans
7.
Cancers (Basel) ; 13(5)2021 Mar 09.
Article in English | MEDLINE | ID: mdl-33803333

ABSTRACT

Ionizing radiation (IR) is used in radiotherapy as a treatment to destroy cancer. Such treatment also affects other tissues, resulting in the so-called normal tissue complications. Endothelial cells (ECs) composing the microvasculature have essential roles in the microenvironment's homeostasis (ME). Thus, detrimental effects induced by irradiation on ECs can influence both the tumor and healthy tissue. In-vitro models can be advantageous to study these phenomena. In this systematic review, we analyzed in-vitro models of ECs subjected to IR. We highlighted the critical issues involved in the production, irradiation, and analysis of such radiobiological in-vitro models to study microvascular endothelial cells damage. For each step, we analyzed common methodologies and critical points required to obtain a reliable model. We identified the generation of a 3D environment for model production and the inclusion of heterogeneous cell populations for a reliable ME recapitulation. Additionally, we highlighted how essential information on the irradiation scheme, crucial to correlate better observed in vitro effects to the clinical scenario, are often neglected in the analyzed studies, limiting the translation of achieved results.

8.
Phys Med ; 73: 125-134, 2020 May.
Article in English | MEDLINE | ID: mdl-32361401

ABSTRACT

BACKGROUND: Radiation-induced organ dysfunction are frequently described by Normal Tissue Complication Probability models. The approximations of this radiobiological approach do not allow to consider the important role played by the microvasculature not only in the dose-response of the blood vessels but also of the organs where it is located. To this purpose, we presented a computational model that describes the fluid dynamics of microcirculation when the parameters of the network and the surrounding tissues are affected by radio-induced changes. MATERIALS AND METHODS: The effects of the ionizing radiation on the capillary bed are mediated by the inflammatory response. We derived from a literature search the possible morphological and functional variations of the network due to the process of the acute inflammation. Specifically, we considered vasodilation, increased membrane permeability with consequent fluid extravasation and increased wall elasticity. These perturbations to the system were included in a computational model, already able to describe the physics of the microcirculation and its exchanges with the surrounding tissues. RESULTS: Two computational descriptions were considered. In the first one, we changed a set of 4 parameters associated with the increased fluid exchange from the health scenario at the baseline to a seriously compromised scenario with the edema formation. The second study investigated the effect of a perturbation to the vessel wall elasticity. CONCLUSIONS: These simulations represent a first step towards the challenging objective of understanding and describing in a mechanistic way the effects of radiation on the vascular microenvironment.


Subject(s)
Computer Simulation , Microcirculation/radiation effects , Radiotherapy/adverse effects , Biomechanical Phenomena/radiation effects , Capillaries/physiology , Capillaries/radiation effects , Elasticity/radiation effects , Humans
9.
Adv Healthc Mater ; 9(7): e1901486, 2020 04.
Article in English | MEDLINE | ID: mdl-32125776

ABSTRACT

Polymer nanoparticles (NPs), due to their small size and surface functionalization potential have demonstrated effective drug transport across the blood-brain-barrier (BBB). Currently, the lack of in vitro BBB models that closely recapitulate complex human brain microenvironments contributes to high failure rates of neuropharmaceutical clinical trials. In this work, a previously established microfluidic 3D in vitro human BBB model, formed by the self-assembly of human-induced pluripotent stem cell-derived endothelial cells, primary brain pericytes, and astrocytes in triculture within a 3D fibrin hydrogel is exploited to quantify polymer NP permeability, as a function of size and surface chemistry. Microvasculature are perfused with commercially available 100-400 nm fluorescent polystyrene (PS) NPs, and newly synthesized 100 nm rhodamine-labeled polyurethane (PU) NPs. Confocal images are taken at different timepoints and computationally analyzed to quantify fluorescence intensity inside/outside the microvasculature, to determine NP spatial distribution and permeability in 3D. Results show similar permeability of PS and PU NPs, which increases after surface-functionalization with brain-associated ligand holo-transferrin. Compared to conventional transwell models, the method enables rapid analysis of NP permeability in a physiologically relevant human BBB set-up. Therefore, this work demonstrates a new methodology to preclinically assess NP ability to cross the human BBB.


Subject(s)
Blood-Brain Barrier , Endothelial Cells , Brain , Humans , Microvessels , Pericytes
10.
Small ; 15(46): e1902393, 2019 11.
Article in English | MEDLINE | ID: mdl-31497931

ABSTRACT

In vitro prediction of physiologically relevant transport of therapeutic molecules across the microcirculation represents an intriguing opportunity to predict efficacy in human populations. On-chip microvascular networks (MVNs) show physiologically relevant values of molecular permeability, yet like most systems, they lack an important contribution to transport: the ever-present fluid convection through the endothelium. Quantification of transport through the MVNs by current methods also requires confocal imaging and advanced analytical techniques, which can be a bottleneck in industry and academic laboratories. Here, it is shown that by recapitulating physiological transmural flow across the MVNs, the concentration of small and large molecule therapeutics can be directly sampled in the interstitial fluid and analyzed using standard analytical techniques. The magnitudes of transport measured in MVNs reveal trends with molecular size and type (protein versus nonprotein) that are expected in vivo, supporting the use of the MVNs platform as an in vitro tool to predict distribution of therapeutics in vivo.


Subject(s)
Extracellular Fluid/physiology , Microvessels/physiology , Regional Blood Flow/physiology , Blood Proteins/metabolism , Fluorescein-5-isothiocyanate/metabolism , Human Umbilical Vein Endothelial Cells/metabolism , Humans , Lab-On-A-Chip Devices , Perfusion , Permeability , Pressure , Protein Transport
11.
Microvasc Res ; 122: 101-110, 2019 03.
Article in English | MEDLINE | ID: mdl-30448400

ABSTRACT

Fluid homeostasis is required for life. Processes involved in fluid balance are strongly related to exchanges at the microvascular level. Computational models have been presented in the literature to analyze the microvascular-interstitial interactions. As far as we know, none of those models consider a physiological description for the lymphatic drainage-interstitial pressure relation. We develop a computational model that consists of a network of straight cylindrical vessels and an isotropic porous media with a uniformly distributed sink term acting as the lymphatic system. In order to describe the lymphatic flow rate, a non-linear function of the interstitial pressure is defined, based on literature data on the lymphatic system. The proposed model of lymphatic drainage is compared to a linear one, as is typically used in computational models. To evaluate the response of the model, the two are compared with reference to both physiological and pathological conditions. Differences in the local fluid dynamic description have been observed using the non-linear model. In particular, the distribution of interstitial pressure is heterogeneous in all the cases analyzed. The resulting averaged values of the interstitial pressure are also different, and they agree with literature data when using the non-linear model. This work highlights the key role of lymphatic drainage and its modeling when studying the fluid balance in microcirculation for both to physiological and pathological conditions, e.g. uremia.


Subject(s)
Computer Simulation , Lymph/physiology , Lymphatic Vessels/physiology , Models, Anatomic , Numerical Analysis, Computer-Assisted , Water-Electrolyte Balance , Finite Element Analysis , Humans , Linear Models , Lymph/metabolism , Lymphatic Vessels/anatomy & histology , Lymphatic Vessels/metabolism , Nonlinear Dynamics , Porosity , Pressure , Uremia/metabolism , Uremia/physiopathology
12.
Int J Numer Method Biomed Eng ; 35(3): e3165, 2019 03.
Article in English | MEDLINE | ID: mdl-30358172

ABSTRACT

We present a two-phase model for microcirculation that describes the interaction of plasma with red blood cells. The model takes into account of typical effects characterizing the microcirculation, such as the Fahraeus-Lindqvist effect and plasma skimming. Besides these features, the model describes the interaction of capillaries with the surrounding tissue. More precisely, the model accounts for the interaction of capillary transmural flow with the surrounding interstitial pressure. Furthermore, the capillaries are represented as one-dimensional channels with arbitrary, possibly curved configuration. The latter two features rely on the unique ability of the model to account for variations of flow rate and pressure along the axis of the capillary, according to a local differential formulation of mass and momentum conservation. Indeed, the model stands on a solid mathematical foundation, which is also addressed in this work. In particular, we present the model derivation, the variational formulation, and its approximation using the finite element method. Finally, we conclude the work with a comparative computational study of the importance of the Fahraeus-Lindqvist, plasma skimming, and capillary leakage effects on the distribution of flow in a microvascular network.


Subject(s)
Capillaries/physiology , Computer Simulation , Hemorheology , Microcirculation/physiology , Models, Cardiovascular , Plasma , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...