PLoS One ; 19(6): e0304378, 2024.
Article in English | MEDLINE | ID: mdl-38865328

ABSTRACT

OBJECTIVE: Evaluate the effects of five disinfection methods on bacterial concentrations in hospital sink drains, focusing on three opportunistic pathogens (OPs): Serratia marcescens, Pseudomonas aeruginosa and Stenotrophomonas maltophilia. DESIGN: Over two years, three sampling campaigns were conducted in a neonatal intensive care unit (NICU). Samples from 19 sink drains were taken at three time points: before, during, and after disinfection. Bacterial concentration was measured using culture-based and flow cytometry methods. High-throughput short sequence typing was performed to identify the three OPs and assess S. marcescens persistence after disinfection at the genotypic level. SETTING: This study was conducted in a pediatric hospitals NICU in Montréal, Canada, which is divided in an intensive and intermediate care side, with individual rooms equipped with a sink. INTERVENTIONS: Five treatments were compared: self-disinfecting drains, chlorine disinfection, boiling water disinfection, hot tap water flushing, and steam disinfection. RESULTS: This study highlights significant differences in the effectiveness of disinfection methods. Chlorine treatment proved ineffective in reducing bacterial concentration, including the three OPs. In contrast, all other drain interventions resulted in an immediate reduction in culturable bacteria (4-8 log) and intact cells (2-3 log). Thermal methods, particularly boiling water and steam treatments, exhibited superior effectiveness in reducing bacterial loads, including OPs. However, in drains with well-established bacterial biofilms, clonal strains of S. marcescens recolonized the drains after heat treatments. CONCLUSIONS: Our study supports thermal disinfection (>80°C) for pathogen reduction in drains but highlights the need for additional trials and the implementation of specific measures to limit biofilm formation.


Subject(s)
Disinfection , Intensive Care Units, Neonatal , Serratia marcescens , Serratia marcescens/drug effects , Disinfection/methods , Humans , Pseudomonas aeruginosa/drug effects , Infant, Newborn , Stenotrophomonas maltophilia/drug effects , Serratia Infections/microbiology , Serratia Infections/prevention & control , Cross Infection/prevention & control , Cross Infection/microbiology
2.
Sci Total Environ ; 939: 173651, 2024 May 29.
Article in English | MEDLINE | ID: mdl-38821274

ABSTRACT

Secondary disinfection aims to prevent microbial regrowth during distribution by maintaining disinfectant residuals in water systems. However, multi-factorial interactions contribute to free chlorine decay in distribution systems, and even more so in building plumbing. Assembling 1737 samples from nine large institutional buildings, a meta-analysis was conducted to determine whether building managers can actively rely on incoming free chlorine residuals to prevent in-building microbial amplification. Findings showed that free chlorine concentrations in first draws met the 0.2 mg/L common guide level in respectively 26 %, 6 % and 2 % of cold, tepid and hot water samples, whereas flushing for 2-60 min only significantly increased this ratio in cold water (83 %), without reaching background levels found in service lines. Free chlorine was significantly but weakly (R≤ 0.2) correlated to adenosine triphosphate, heterotrophic plate count and total and intact cell counts, thus evidencing that residuals contributed to decreased culturable and viable biomass. Detection of culturable Legionella pneumophila spanning over a 4-log distribution solely occurred when free chlorine levels were below 0.2 mg/L, but no such trend could be distinguished clearly for culturable Pseudomonas aeruginosa. Water temperatures below 20 °C and >60 °C also completely prevented L. pneumophila detection. Overall, the majority of elevated microbial counts were measured in distal sites and in tepid and hot water, where free chlorine is less likely to be present due to stagnation and increased temperature. Therefore, building managers cannot solely rely on this chemical barrier to mitigate bacterial growth in bulk water.

3.
Water Res ; 256: 121490, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38614028

ABSTRACT

Urbanization increases the land surface temperature through surface mineralization, adversely affecting vegetation and enhancing the urban heat island (UHI) effect. Global climate change has intensified this warming effect with more frequent and intense heatwaves during hot seasons. While these transformations influence soil temperature, their consequences on drinking water temperature within the drinking water distribution system (DWDS) remains poorly understood. Literature proposes to increase pipe burial depths to mitigate drinking water heating during summer. In this study, we monitored drinking water temperatures in a DWDS in Montreal, Canada with deeply buried pipes (average 1.8 m) during the summer of 2022, focusing on two contrasting zones in terms of UHI and green coverage. Monitoring revealed a 8°C heating effect compared to the water treatment plant, attributed to low green coverage and anthropogenic heat. Conversely, the greener zone exhibited cooler drinking water temperatures, reaching a maximum cooling effect of 8°C as compared to the temperature at the exit of the water treatment plant. Utilizing a soil and water temperature model, we predicted drinking water temperatures within the DWDS with acceptable accuracy. Soil temperature modeling results aligned well with measured water temperatures, highlighting DWDS water temperature approaching its surrounding soil temperature fairly quickly. Despite heatwaves, no immediate correlation emerged between air temperature records and measured water temperatures, emphasizing soil temperature as a superior indicator. An increase in water age displayed no correlation with an increase in measured water temperature, underscoring the dominant influence of UHI and green coverage on water temperature. These findings highlight the cooling advantages of green spaces during summer, providing valuable insights for sustainable urban planning.


Subject(s)
Cities , Drinking Water , Hot Temperature , Temperature , Quebec , Canada , Climate Change , Environmental Monitoring/methods , Models, Theoretical , Water Supply , Seasons
4.
J Environ Manage ; 355: 120470, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38422852

ABSTRACT

The global change in surface water quality calls for increased preparedness of drinking water utilities. The increasing frequency of extreme climatic events combined with global warming can impact source and treated water characteristics such as temperature and natural organic matter. On the other hand, water saving policies in response to water and energy crisis in some countries can aggravate the situation by increasing the water residence time in the drinking water distribution system (DWDS). This study investigates the individual and combined effect of increased dissolved organic carbon (DOC), increased temperature, and reduced water demand on fate and transport of chlorine and trihalomethanes (THMs) within a full-scale DWDS in Canada. Chlorine and THM prediction models were calibrated with laboratory experiments and implemented in EPANET-MATLAB toolkit for prediction in the DWDS under different combinations of DOC, temperature, and demand. The duration of low chlorine residuals (<0.2 mg/L) and high THM (>80 µg/L) periods within a day in each scenario was reported using a reliability index. Low-reliability zones prone to microbial regrowth or high THM exposure were then delineated geographically on the city DWDS. Results revealed that water demand reduction primarily affects chlorine availability, with less concern for THM formation. The reduction in nodal chlorine reliability was gradual with rising temperature and DOC of the treated water and reducing water demand. Nodal THM reliability remained unchanged until certain thresholds were reached, i.e., temperature >25 °C for waters with DOC <1.52 mg/L, and DOC >2.2 mg/L for waters with temperature = 17 °C. At these critical thresholds, an abrupt network-wide THM exceedance of 80 µg/L occurred. Under higher DOC and temperature levels in future, employing the proposed approach revealed that increasing the applied chlorine dosage (which is a conventional method used to ensure sufficient chlorine coverage) results in elevated exposure toTHMs and is not recommended. This approach aids water utilities in assessing the effectiveness of different intervention measures to solve water quality problems, identify site-specific thresholds leading to major decreases in system reliability, and integrate climate adaptation into water safety management.


Subject(s)
Drinking Water , Water Pollutants, Chemical , Water Purification , Chlorine , Water Purification/methods , Trihalomethanes/analysis , Climate Change , Reproducibility of Results , Chlorides , Water Pollutants, Chemical/analysis , Disinfection
5.
Water Res ; 254: 121374, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38422696

ABSTRACT

Intense rainfall and snowmelt events may affect the safety of drinking water, as large quantities of fecal material can be discharged from storm or sewage overflows or washed from the catchment into drinking water sources. This study used ß-d-glucuronidase activity (GLUC) with microbial source tracking (MST) markers: human, bovine, porcine mitochondrial DNA markers (mtDNA) and human-associated Bacteroidales HF183 and chemical source tracking (CST) markers including caffeine, carbamazepine, theophylline and acetaminophen, pathogens (Giardia, Cryptosporidium, adenovirus, rotavirus and enterovirus), water quality indicators (Escherichia coli, turbidity) and hydrometeorological data (flowrate, precipitation) to assess the vulnerability of 3 drinking water intakes (DWIs) and identify sources of fecal contamination. Water samples were collected under baseline, snow and rain events conditions in urban and agricultural catchments (Québec, Canada). Dynamics of E. coli, HF183 and WWMPs were similar during contamination events, and concentrations generally varied over 1 order of magnitude during each event. Elevated human-associated marker levels during events demonstrated that urban DWIs were impacted by recent contamination from an upstream municipal water resource recovery facility (WRRF). In the agricultural catchment, mixed fecal pollution was observed with the occurrences and increases of enteric viruses, human bovine and porcine mtDNA during peak contaminating events. Bovine mtDNA qPCR concentrations were indicative of runoff of cattle-derived fecal pollutants to the DWI from diffuse sources following rain events. This study demonstrated that the suitability of a given MST or CST indicator depend on river and catchment characteristics. The sampling strategy using continuous online GLUC activity coupled with MST and CST markers analysis was a more reliable source indicator than turbidity to identify peak events at drinking water intakes.


Subject(s)
Cryptosporidiosis , Cryptosporidium , Drinking Water , Enterovirus , Animals , Cattle , Swine , Humans , Escherichia coli , Environmental Monitoring , DNA, Mitochondrial , Glucuronidase
6.
Environ Monit Assess ; 195(9): 1042, 2023 Aug 17.
Article in English | MEDLINE | ID: mdl-37589790

ABSTRACT

Worldwide, there has been an increase in the presence of potentially toxic cyanobacterial blooms in drinking water sources and within drinking water treatment plants (DWTPs). The objective of this study is to validate the use of in situ probes for the detection and management of cyanobacterial breakthrough in high and low-risk DWTPs. In situ phycocyanin YSI EXO2 probes were devised for remote control and data logging to monitor the cyanobacteria in raw, clarified, filtered, and treated water in three full-scale DWTPs. An additional probe was installed inside the sludge holding tank to measure the water quality of the surface of the sludge storage tank in a high-risk DWTP. Simultaneous grab samplings were carried out for taxonomic cell counts and toxin analysis. A total of 23, 9, and 4 field visits were conducted at the three DWTPs. Phycocyanin readings showed a 93-fold fluctuation within 24 h in the raw water of the high cyanobacterial risk plant, with higher phycocyanin levels during the afternoon period. These data provide new information on the limitations of weekly or daily grab sampling. Also, different moving averages for the phycocyanin probe readings can be used to improve the interpretation of phycocyanin signal trends. The in situ probe successfully detected high cyanobacterial biovolumes entering the clarification process in the high-risk plant. Grab sampling results revealed high cyanobacterial biovolumes in the sludge for both high and low-risk plants.


Subject(s)
Cyanobacteria , Drinking Water , Phycocyanin , Sewage , Environmental Monitoring
7.
Microorganisms ; 11(6)2023 May 23.
Article in English | MEDLINE | ID: mdl-37374862

ABSTRACT

Shock chlorination and remedial flushing are suggested to address Legionella pneumophila (Lp) contamination in buildings or during their (re)commissioning. However, data on general microbial measurements (adenosine tri-phosphate [ATP], total cell counts [TCC]), and the abundance of Lp are lacking to support their temporary implementation with variable water demands. In this study, the weekly short-term (3-week) impact of shock chlorination (20-25 mg/L free chlorine, 16 h) or remedial flushing (5-min flush) combined with distinct flushing regimes (daily, weekly, stagnant) was investigated in duplicates of showerheads in two shower systems. Results showed that the combination of stagnation and shock chlorination prompted biomass regrowth, with ATP and TCC in the first draws reaching large regrowth factors of 4.31-7.07-fold and 3.51-5.68-fold, respectively, from baseline values. Contrastingly, remedial flushing followed by stagnation generally resulted in complete or larger regrowth in Lp culturability and gene copies (gc). Irrespective of the intervention, daily flushed showerheads resulted in significantly (p < 0.05) lower ATP and TCC, as well as lower Lp concentrations than weekly flushes, in general. Nonetheless, Lp persisted at concentrations ranging from 11 to 223 as the most probable number per liter (MPN/L) and in the same order of magnitude (103-104 gc/L) than baseline values after remedial flushing, despite daily/weekly flushing, unlike shock chlorination which suppressed Lp culturability (down 3-log) for two weeks and gene copies by 1-log. This study provides insights on the most optimal short-term combination of remedial and preventative strategies that can be considered pending the implementation of suitable engineering controls or building-wide treatment.

8.
Appl Environ Microbiol ; 89(5): e0010523, 2023 05 31.
Article in English | MEDLINE | ID: mdl-37067412

ABSTRACT

Compelling evidence suggests a contribution of the sink environment to the transmission of opportunistic pathogens from the hospital environment to patients in neonatal intensive care units (NICU). In this study, the distribution of the opportunistic pathogen Serratia marcescens in the sink environment and newborns in a NICU was investigated. More than 500 sink drain and faucet samples were collected over the course of five sampling campaigns undertaken over 3 years. Distribution and diversity of S. marcescens were examined with a modified MacConkey medium and a high-throughput short-sequence typing (HiSST) method. Sink drains were an important reservoir of S. marcescens, with an average of 44% positive samples, whereas no faucet sample was positive. The genotypic diversity of S. marcescens was moderate, with an average of two genotypes per drain, while the spatial distribution of S. marcescens was heterogeneous. The genotypic profiles of 52 clinical isolates were highly heterogeneous, with 27 unique genotypes, of which 71% of isolates were found in more than one patient. S. marcescens acquisition during the first outbreaks was mainly caused by horizontal transmissions. HiSST analyses revealed 10 potential cases of patient-to-patient transmission of S. marcescens, five cases of patient-to-sink transmission, and one bidirectional transfer between sink and patient. Environmental and clinical isolates were found in sink drains up to 1 year after the first detection, supporting persisting drain colonization. This extensive survey suggests multiple reservoirs of S. marcescens within the NICU, including patients and sink drains, but other external sources should also be considered. IMPORTANCE The bacterium Serratia marcescens is an important opportunistic human pathogen that thrives in many environments, can become multidrug resistant, and is often involved in nosocomial outbreaks in neonatal intensive care units (NICU). We evaluated the role of sinks during five suspected S. marcescens outbreaks in a NICU. An innovative approach combining molecular and culture methods was used to maximize the detection and typing of S. marcescens in the sink environment. Our results indicate multiple reservoirs of S. marcescens within the NICU, including patients, sink drains, and external sources. These results highlight the importance of sinks as a major reservoir of S. marcescens and potential sources of future outbreaks.


Subject(s)
Cross Infection , Serratia Infections , Humans , Infant, Newborn , Intensive Care Units, Neonatal , Cross Infection/microbiology , Serratia marcescens/genetics , Serratia Infections/epidemiology , Disease Outbreaks
10.
Sci Total Environ ; 879: 162975, 2023 Jun 25.
Article in English | MEDLINE | ID: mdl-36965725

ABSTRACT

Water conservation measures are increasing in response to regulatory requirements addressing the need for lower environmental footprint and in response to water shortages. In households with lead service lines (LSLs), lowering consumption can adversely impact lead release as it will increase stagnation. Using a lead dissolution model and data from extensive pilot studies on excavated LSLs, the impact of adaptation to different water conservation strategies on dissolved lead contamination at the kitchen tap is assessed under three water qualities and three LSL lengths (3, 14 and 30 m) using hydraulic and water quality modelling. Consumers' behavioural variability is also assessed based on integration of EPANET and results of the stochastic water demand model SIMDEUM. Demand reduction increased the dissolved lead concentrations (Pbdiss) at the end of the LSL with mean values ranging from 28.4 to 63.3 µg/L (without corrosion control) and from 4.6 to 9.9 µg/L with corrosion control (addition of orthophosphate and pH adjustment). Adding orthophosphate (1 mg P/L) to the water reduces the mean Pbdiss values at the kitchen tap from 7.1 µg/L to 1.2 µg/L for a high water demand scenario and from 31.2 to 4.9 µg/L for a low water demand scenario. Finally, the Integrated Exposure Uptake Biokinetic (IEUBK) model is used to predict the potential blood lead levels (BLLs) for children aged 0-84 months. Results showed that the orthophosphate addition of only 1 mg P/L can significantly decrease the proportion of children with a BLL >5 µg/dL, from 82 % to 17 %, under the most extreme water conservation scenario studied, using the 90th percentile of Pbdiss concentrations during usage at kitchen tap. Wide variations of Pbdiss concentrations at the kitchen tap were calculated at times of use over a week (up to 155 µg/L in lower demand scenarios, without corrosion control) showing evident limitations of single random daytime sampling.


Subject(s)
Drinking Water , Water Pollutants, Chemical , Child , Humans , Water Quality , Sanitary Engineering , Water Supply , Lead/analysis , Drinking , Water Pollutants, Chemical/analysis , Phosphates
11.
Water Res ; 229: 119432, 2023 Feb 01.
Article in English | MEDLINE | ID: mdl-36495852

ABSTRACT

Faucet aerators that form aerated water jets generate aerosols, which can constitute a risk of infection if the water is contaminated, particularly for vulnerable individuals near the sink. In this study, we characterize the size and trajectory of water droplets produced from an aerated jet. The detected particle diameter ranged from 3 to 150µm. The concentration of droplets in the air varied from near-zero to a maximum of 2×1011particles/m3, depending on the location relative to the jet. We found four relevant categories of droplets based on their trajectories following their emission at the jet's free surface: particles with inertia high enough to escape the immediate vicinity of the jet (category 1), particles moving towards the jet (category 2), particles drawn into the aerator, which only included particles with a diameter smaller than 50µm (category 3), and particles with a near-vertical trajectory (category 4). Tracing category 1 particles to their generation location on the water interface shows a higher emission rate near the aerator. Finally, we employ a numerical model to compute the subsequent trajectories of droplets detected at the limits of the sampled domain. We find that particles whose diameter is smaller than 55µm completely dry and become airborne. Larger droplets deposit within a radius of 7cm around the jet, assuming a surface is located 20cm below the aerator tip. These results increase the fundamental understanding of the emission mechanisms of droplets in aerated jets and their fate in the sink environment.


Subject(s)
Water , Humans , Aerosols
12.
Microorganisms ; 12(1)2023 Dec 27.
Article in English | MEDLINE | ID: mdl-38257875

ABSTRACT

Molecular typing techniques are utilized to determine genetic similarities between bacterial isolates. However, the use of environmental DNA profiling to assess epidemiologic links between patients and their environment has not been fully explored. This work reports the development and validation of two high-throughput short sequence typing (HiSST) schemes targeting the opportunistic pathogens Pseudomonas aeruginosa and Stenotrophomonas maltophilia, along with a modified SM2I selective medium for the specific isolation of S. maltophilia. These HiSST schemes are based on four discriminative loci for each species and demonstrate high discriminating power, comparable to pairwise whole-genome comparisons. Each scheme includes species-specific PCR primers for precise differentiation from closely related taxa, without the need for upstream culture-dependent methods. For example, the primers targeting the bvgS locus make it possible to distinguish P. aeruginosa from the very closely related Pseudomonas paraeruginosa sp. nov. The selected loci included in the schemes are adapted to massive parallel amplicon sequencing technology. An R-based script implemented in the DADA2 pipeline was assembled to facilitate HiSST analyses for efficient and accurate genotyping of P. aeruginosa and S. maltophilia. We demonstrate the performance of both schemes through in silico validations, assessments against reference culture collections, and a case study involving environmental samples.

14.
Toxins (Basel) ; 14(11)2022 10 31.
Article in English | MEDLINE | ID: mdl-36355999

ABSTRACT

Health-related concerns about cyanobacteria-laden sludge of drinking water treatment plants (DWTPs) have been raised in the past few years. Microscopic taxonomy, shotgun metagenomic sequencing, and microcystin (MC) measurement were applied to study the fate of cyanobacteria and cyanotoxins after controlled sludge storage (stagnation) in the dark in a full-scale drinking water treatment plant within 7 to 38 days. For four out of eight dates, cyanobacterial cell growth was observed by total taxonomic cell counts during sludge stagnation. The highest observed cell growth was 96% after 16 days of stagnation. Cell growth was dominated by potential MC producers such as Microcystis, Aphanocapsa, Chroococcus, and Dolichospermum. Shotgun metagenomic sequencing unveiled that stagnation stress shifts the cyanobacterial communities from the stress-sensitive Nostocales (e.g., Dolichospermum) order towards less compromised orders and potential MC producers such as Chroococcales (e.g., Microcystis) and Synechococcales (e.g., Synechococcus). The relative increase of cyanotoxin producers presents a health challenge when the supernatant of the stored sludge is recycled to the head of the DWTP or discharged into the source. These findings emphasize the importance of a strategy to manage cyanobacteria-laden sludge and suggest practical approaches should be adopted to control health/environmental impacts of cyanobacteria and cyanotoxins in sludge.


Subject(s)
Cyanobacteria , Drinking Water , Microcystis , Water Purification , Sewage , Microcystins , Cyanobacteria/genetics
15.
Microbiol Spectr ; 10(6): e0211822, 2022 12 21.
Article in English | MEDLINE | ID: mdl-36314908

ABSTRACT

Legiolert is a rapid culture-based enzymatic method for the detection and quantification of Legionella pneumophila in potable and nonpotable water samples. We aimed to assess the ability of this assay to detect diverse sequence types and validated a simple method to preserve samples. We used this assay on 253 potable and 165 nonpotable cooling tower water samples from various buildings in Québec, Canada, and performed sequence-based typing on 96 isolates. Six sequence types were identified, including ST1, ST378, ST1427, ST2859, ST3054, and ST3069. Whole-genome sequencing revealed that ST2859 was a member of the L. pneumophila subspecies fraseri. Additional tests with pure isolates also found that subspecies Pascullei and Raphaeli could be detected via Legiolert. Eight storage methods, including the current recommendation to store Legiolert trays at 4°C, were evaluated for their ability to preserve viable cultures. Of those, storage of Legiolert culture with 10% glycerol at -80°C produced the best results, fully preserving culturable Legionella for at least 12.5 months. We incorporated these findings into a standard procedure for processing Legiolert packets. Overall, Legiolert captures a variety of common and new STs in addition to important L. pneumophila subspecies and can be easily stored, which allows the conservation of a population of isolates for later characterization. IMPORTANCE Legionnaires' disease is caused by the bacterium Legionella pneumophila, which can be found in a variety of water systems. When outbreaks of Legionnaires' disease occur, it is necessary to find the water systems transmitting the bacterium to humans. Access to historical isolates from water system samples is key for success in identifying sources but current regulations and isolation protocols mean very few isolates are obtained and stored long-term. We showed here that the Legiolert test could detect and produce isolates of a variety of L. pneumophila subspecies and types. In addition, the Legiolert test medium containing a representative population of isolates could be preserved for at least 12 months at -80°C with the addition of glycerol to the test medium. Therefore, we confirmed that the Legiolert method could be a useful tool for retrospective analysis of potential sources for an outbreak.


Subject(s)
Legionella pneumophila , Legionnaires' Disease , Humans , Legionella pneumophila/genetics , Glycerol , Retrospective Studies , Water , Water Microbiology
16.
Toxins (Basel) ; 14(10)2022 Oct 07.
Article in English | MEDLINE | ID: mdl-36287957

ABSTRACT

The excessive proliferation of cyanobacteria in surface waters is a widespread problem worldwide, leading to the contamination of drinking water sources. Short- and long-term solutions for managing cyanobacterial blooms are needed for drinking water supplies. The goal of this research was to investigate the cyanobacteria community composition using shotgun metagenomics in a short term, in situ mesocosm experiment of two lakes following their coagulation with ferric sulfate (Fe2(SO4)3) as an option for source water treatment. Among the nutrient paramenters, dissolved nitrogen was related to Microcystis in both Missisquoi Bay and Petit Lac St. François, while the presence of Synechococcus was related to total nitrogen, dissolved nitrogen, dissolved organic carbon, and dissolved phosphorus. Results from the shotgun metagenomic sequencing showed that Dolichospermum and Microcystis were the dominant genera in all of the mesocosms in the beginning of the sampling period in Missisquoi Bay and Petit Lac St. François, respectively. Potentially toxigenic genera such as Microcystis were correlated with intracellular microcystin concentrations. A principal component analysis showed that there was a change of the cyanobacterial composition at the genus level in the mesocosms after two days, which varied across the studied sites and sampling time. The cyanobacterial community richness and diversity did not change significantly after its coagulation by Fe2(SO4)3 in all of the mesocosms at either site. The use of Fe2(SO4)3 for an onsite source water treatment should consider its impact on cyanobacterial community structure and the reduction of toxin concentrations.


Subject(s)
Cyanobacteria , Drinking Water , Microcystis , Microcystins/analysis , Drinking Water/analysis , Cyanobacteria/genetics , Microcystis/genetics , Lakes/microbiology , Nitrogen/analysis , Phosphorus/analysis
17.
Toxins (Basel) ; 14(6)2022 06 15.
Article in English | MEDLINE | ID: mdl-35737071

ABSTRACT

Freshwater bodies and, consequently, drinking water treatment plants (DWTPs) sources are increasingly facing toxic cyanobacterial blooms. Even though conventional treatment processes including coagulation, flocculation, sedimentation, and filtration can control cyanobacteria and cell-bound cyanotoxins, these processes may encounter challenges such as inefficient removal of dissolved metabolites and cyanobacterial cell breakthrough. Furthermore, conventional treatment processes may lead to the accumulation of cyanobacteria cells and cyanotoxins in sludge. Pre-oxidation can enhance coagulation efficiency as it provides the first barrier against cyanobacteria and cyanotoxins and it decreases cell accumulation in DWTP sludge. This critical review aims to: (i) evaluate the state of the science of cyanobacteria and cyanotoxin management throughout DWTPs, as well as their associated sludge, and (ii) develop a decision framework to manage cyanobacteria and cyanotoxins in DWTPs and sludge. The review identified that lab-cultured-based pre-oxidation studies may not represent the real bloom pre-oxidation efficacy. Moreover, the application of a common exposure unit CT (residual concentration × contact time) provides a proper understanding of cyanobacteria pre-oxidation efficiency. Recently, reported challenges on cyanobacterial survival and growth in sludge alongside the cell lysis and cyanotoxin release raised health and technical concerns with regards to sludge storage and sludge supernatant recycling to the head of DWTPs. According to the review, oxidation has not been identified as a feasible option to handle cyanobacterial-laden sludge due to low cell and cyanotoxin removal efficacy. Based on the reviewed literature, a decision framework is proposed to manage cyanobacteria and cyanotoxins and their associated sludge in DWTPs.


Subject(s)
Cyanobacteria , Drinking Water , Water Purification , Cyanobacteria/metabolism , Cyanobacteria Toxins , Microcystins/metabolism , Sewage/microbiology
18.
Water Res ; 216: 118328, 2022 Jun 01.
Article in English | MEDLINE | ID: mdl-35364354

ABSTRACT

Legionella pneumophila is a natural inhabitant of water systems. From there, it can be transmitted to humans by aerosolization resulting in severe pneumonia. Most large outbreaks are caused by cooling towers colonized with L. pneumophila. The resident microbiota of the cooling tower is a key determinant for the colonization and growth of L. pneumophila. In our preceding study, the genus Pseudomonas correlated negatively with the presence of L. pneumophila in cooling towers, but it was not clear which species was responsible. Therefore, we identified the Pseudomonas species inhabiting 14 cooling towers using a Pseudomonas-specific 16S rRNA amplicon sequencing strategy. We found that cooling towers that are free of L. pneumophila contained a high relative abundance of members from the Pseudomonas alcaliphila/oleovorans phylogenetic cluster. P. alcaliphila JCM 10630 inhibited the growth of L. pneumophila on agar plates. Analysis of the P. alcaliphila genome revealed the presence of a gene cluster predicted to produce toxoflavin. L. pneumophila growth was inhibited by pure toxoflavin and by extracts from P. alcaliphila culture found to contain toxoflavin by liquid chromatography coupled with mass spectrometry. In addition, toxoflavin inhibits the growth of Vermameoba vermiformis, a host cell of L. pneumophila. Our study indicates that P. alcaliphila may be important to restrict growth of L. pneumophila in water systems through the production of toxoflavin. A sufficiently high concentration of toxoflavin is likely not achieved in the bulk water but might have a local inhibitory effect such as near or in biofilms.


Subject(s)
Legionella pneumophila , Legionella , Humans , Legionella/genetics , Legionella pneumophila/genetics , Phylogeny , Pseudomonas/genetics , Pyrimidinones , RNA, Ribosomal, 16S/genetics , Triazines , Water , Water Microbiology
19.
Microorganisms ; 10(2)2022 Feb 15.
Article in English | MEDLINE | ID: mdl-35208896

ABSTRACT

Intermittent reduction of temperature set-points and periodic shutdowns of water heaters have been proposed to reduce energy consumption in buildings. However, the consequences of such measures on the occurrence and proliferation of Legionella pneumophila (Lp) in hot water systems have not been documented. The impact of single and repeated heat shocks was investigated using an environmental strain of L. pneumophila and a reference strain of V. vermiformis. Heat shocks at temperatures ranging from 50 °C to 70 °C were applied for 1 h and 4 h in water and water heaters loose deposits (sludge). The regrowth potential of heat-treated culturable L. pneumophila in presence of V. vermiformis in water heaters sludges was evaluated. A 2.5-log loss of culturability of L. pneumophila was observed in simulated drinking water at 60 °C while a 4-log reduction was reached in water heaters loose deposits. Persistence of Lp after 4 h at 55 °C was shown and the presence of V. vermiformis in water heater's loose deposits resulted in a drastic amplification (5-log). Results show that thermal inactivation by heat shock is only efficient at elevated temperatures (50 °C) in both water and loose deposits. The few remaining organisms can rapidly proliferate during storage at lower temperature in the presence of hosts.

20.
Water Res ; 211: 117997, 2022 Mar 01.
Article in English | MEDLINE | ID: mdl-34999316

ABSTRACT

In recent years, drinking water-associated pathogens that can cause infections in immunocompromised or otherwise susceptible individuals (henceforth referred to as DWPI), sometimes referred to as opportunistic pathogens or opportunistic premise plumbing pathogens, have received considerable attention. DWPI research has largely been conducted by experts focusing on specific microorganisms or within silos of expertise. The resulting mitigation approaches optimized for a single microorganism may have unintended consequences and trade-offs for other DWPI or other interests (e.g., energy costs and conservation). For example, the ecological and epidemiological issues characteristic of Legionella pneumophila diverge from those relevant for Mycobacterium avium and other nontuberculous mycobacteria. Recent advances in understanding DWPI as part of a complex microbial ecosystem inhabiting drinking water systems continues to reveal additional challenges: namely, how can all microorganisms of concern be managed simultaneously? In order to protect public health, we must take a more holistic approach in all aspects of the field, including basic research, monitoring methods, risk-based mitigation techniques, and policy. A holistic approach will (i) target multiple microorganisms simultaneously, (ii) involve experts across several disciplines, and (iii) communicate results across disciplines and more broadly, proactively addressing source water-to-customer system management.


Subject(s)
Drinking Water , Legionella pneumophila , Communication , Ecosystem , Humans , Sanitary Engineering , Water Microbiology , Water Supply