1.
Radiat Res ; 198(2): 134-144, 2022 08 01.
Article in English | MEDLINE | ID: mdl-35504003

ABSTRACT

Boron neutron capture therapy (BNCT) is a treatment modality for cancer that involves radiations of different qualities. A formalism that proved suitable to compute doses in photon-equivalent units is the photon isoeffective dose model. This study addresses the question whether considering in vitro or in vivo radiobiological studies to determine the parameters involved in photon isoeffective dose calculations affects the consistency of the model predictions. The analysis is focused on head and neck squamous cell carcinomas (HNSCC), a main target that proved to respond to BNCT. The photon isoeffective dose model for HNSCC with parameters from in vitro studies using the primary human cell line UT-SCC-16A was introduced and compared to the one previously reported with parameters from an in vivo oral cancer model in rodents. Both models were first compared in a simple scenario by means of tumor dose and control probability calculations. Then, the clinical impact of the different dose models was assessed from the analysis of a group of squamous cell carcinomas (SCC) patients treated with BNCT. Traditional dose calculations using the relative biological effectiveness factors derived from the SCC cell line were also analyzed. Predictions of tumor control from the evaluated models were compared to the patients' outcome. The quantification of the biological effectiveness of the different radiations revealed that relative biological effectiveness/compound biological effectiveness (RBE/CBE) factors for the SCC cell line are up to 20% higher than those assumed in clinical BNCT, highlighting the importance of using experimental data intimately linked to the tumor type to derive the model's parameters. The comparison of the different models showed that photon isoeffective doses based on in vitro data are generally greater than those from in vivo data (∼8-16% for total tumor absorbed doses of 10-15 Gy). However, the predictive power of the two models was not affected by these differences: both models fulfilled conditions to guarantee a good predictive performance and gave predictions statistically compatible with the clinical outcome. On the other hand, doses computed with the traditional model were substantially larger than those obtained with both photon isoeffective models. Moreover, the traditional model is statistically rejected, which reinforces the assertion that its inconsistencies are intrinsic and not due to the use of RBE/CBE factors obtained for a tumor type different from HN cancer. The results suggest that the nature of the radiobiological data would not affect the consistency of the photon isoeffective dose model in the studied cases of SCC head and neck cancer treated with BPA-based BNCT.


Subject(s)
Boron Neutron Capture Therapy , Carcinoma, Squamous Cell , Head and Neck Neoplasms , Boron Neutron Capture Therapy/methods , Carcinoma, Squamous Cell/radiotherapy , Head and Neck Neoplasms/radiotherapy , Humans , Photons/therapeutic use , Relative Biological Effectiveness , Squamous Cell Carcinoma of Head and Neck
2.
Phys Med ; 89: 282-292, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34474326

ABSTRACT

PURPOSE: Boron Neutron Capture Therapy (BNCT) is a form of hadrontherapy based on the selective damage caused by the products of neutron capture in 10B to tumour cells. BNCT dosimetry strongly depends on the parameters of the dose calculation models derived from radiobiological experiments. This works aims at determining an adequate dosimetry for in-vitro experiments involving irradiation of monolayer-cultured cells with photons and BNCT and assessing its impact on clinical settings. M&M: Dose calculations for rat osteosarcoma UMR-106 and human metastatic melanoma Mel-J cell survival experiments were performed using MCNP, transporting uncharged particles for KERMA determinations, and secondary particles (electrons, protons, 14C, 4He and 7Li) to compute absorbed dose in cultures. Dose-survival curves were modified according to the dose correction factors determined from computational studies. New radiobiological parameters of the photon isoeffective dose models for osteosarcoma and metastatic melanoma tumours were obtained. Dosimetry implications considering cutaneous melanoma patients treated in Argentina with BNCT were assessed and discussed. RESULTS: KERMA values for the monolayer-cultured cells overestimate absorbed doses of radiation components of interest in BNCT. Detailed dose calculations for the osteosarcoma irradiation increased the relative biological effectiveness factor RBE1% of the neutron component in more than 30%. The analysis based on melanoma cases reveals that the use of survival curves based on KERMA leads to an underestimation of the tumour doses delivered to patients. CONCLUSIONS: Considering detailed dose calculation for in-vitro experiments significantly impact on the prediction of the tumor control in patients. Therefore, proposed methods are clinically relevant.


Subject(s)
Boron Neutron Capture Therapy , Melanoma , Skin Neoplasms , Animals , Humans , Male , Melanoma/radiotherapy , Radiometry , Rats , Relative Biological Effectiveness
3.
Biology (Basel) ; 10(3)2021 Feb 26.
Article in English | MEDLINE | ID: mdl-33652642

ABSTRACT

(1) Background:The quality of neutron beams for Boron Neutron Capture Therapy (BNCT) is currently defined by its physical characteristics in air. Recommendations exist to define whether a designed beam is useful for clinical treatment. This work presents a new way to evaluate neutron beams based on their clinical performance and on their safety, employing radiobiological quantities. (2) Methods: The case study is a neutron beam for deep-seated tumors from a 5 MeV proton beam coupled to a beryllium target. Physical Figures of Merit were used to design five beams; however, they did not allow a clear ranking of their quality in terms of therapeutic potential. The latter was then evaluated based on in-phantom dose distributions and on the calculation of the Uncomplicated Tumor Control Probability (UTCP). The safety of the beams was also evaluated calculating the in-patient out-of-beam dosimetry. (3) Results: All the beams ensured a UTCP comparable to the one of a clinical beam in phantom; the safety criterion allowed to choose the best candidate. When this was tested in the treatment planning of a real patient treated in Finland, the UTCP was still comparable to the one of the clinical beam. (4) Conclusions: Even when standard physical recommendations are not met, radiobiological and dosimetric criteria demonstrate to be a valid tool to select an effective and safe beam for patient treatment.

4.
Biology (Basel) ; 9(10)2020 Oct 07.
Article in English | MEDLINE | ID: mdl-33036386

ABSTRACT

Translational Boron Neutron Capture Therapy (BNCT) studies performed by our group and clinical BNCT studies worldwide have shown the therapeutic efficacy of BNCT for head and neck cancer. The present BNCT studies in veterinary patients with head and neck cancer were performed to optimize the therapeutic efficacy of BNCT, contribute towards exploring the role of BNCT in veterinary medicine, put in place technical aspects for an upcoming clinical trial of BNCT for head and neck cancer at the RA-6 Nuclear Reactor, and assess the feasibility of employing the existing B2 beam to treat large, deep-seated tumors. Five dogs with head and neck cancer with no other therapeutic option were treated with two applications of BNCT mediated by boronophenyl-alanine (BPA) separated by 3-5 weeks. Two to three portals per BNCT application were used to achieve a potentially therapeutic dose over the tumor without exceeding normal tissue tolerance. Clinical and Computed Tomography results evidenced partial tumor control in all cases, with slight-moderate mucositis, excellent life quality, and prolongation in the survival time estimated at recruitment. These exploratory studies show the potential value of BNCT in veterinary medicine and contribute towards initiating a clinical BNCT trial for head and neck cancer at the RA-6 clinical facility.

5.
Radiat Environ Biophys ; 58(2): 237-245, 2019 05.
Article in English | MEDLINE | ID: mdl-30689023

ABSTRACT

Osteosarcoma is the most common primary malignant tumour of bone in young patients. The survival of these patients has largely been improved due to adjuvant and neo-adjuvant chemotherapy in addition to surgery. Boron neutron capture therapy (BNCT) is proposed as a complementary therapy, due to its ability to inactivate tumour cells that may survive the standard treatment and that may be responsible for recurrences and/or metastases. BNCT is based on neutron irradiation of a tumour enriched in 10B with a boron-loaded drug. Low-energy neutron capture in 10B creates charged particles that impart a high dose to tumour cells, which can be calculated only knowing the boron concentration. Charged particle spectrometry is a method that can be used to quantify boron concentration. This method requires acquisition of the energy spectra of charged particles such as alpha particles produced by neutron capture reactions in thin tissue sections irradiated with low-energy neutrons. Boron concentration is then determined knowing the stopping power of the alpha particles in the sample material. This paper describes the adaptation of this method for bone, with emphasis on sample preparation, experimental set-up and stopping power assessment of the involved alpha particles. The knowledge of boron concentration in healthy bones is important, because it allows for any dose limitation that might be necessary to avoid adverse effects such as bone fragility. The measurement process was studied through Monte Carlo simulations and analytical calculations. Finally, the boron content of bone samples was measured by alpha spectrometry at the TRIGA reactor in Pavia, Italy, and compared to that obtained by neutron autoradiography. The agreement between the results obtained with these techniques confirms the suitability of alpha spectrometry to measure boron in bone.


Subject(s)
Boron/analysis , Femur/chemistry , Adult , Alpha Particles , Animals , Humans , Monte Carlo Method , Sheep
6.
Appl Radiat Isot ; 137: 62-67, 2018 Jul.
Article in English | MEDLINE | ID: mdl-29587160

ABSTRACT

The neutron autoradiography technique using polycarbonate nuclear track detectors (NTD) has been extended to quantify the boron concentration in hard tissues, an application of special interest in Boron Neutron Capture Therapy (BNCT). Chemical and mechanical processing methods to prepare thin tissue sections as required by this technique have been explored. Four different decalcification methods governed by slow and fast kinetics were tested in boron-loaded bones. Due to the significant loss of the boron content, this technique was discarded. On the contrary, mechanical manipulation to obtain bone powder and tissue sections of tens of microns thick proved reproducible and suitable, ensuring a proper conservation of the boron content in the samples. A calibration curve that relates the 10B concentration of a bone sample and the track density in a Lexan NTD is presented. Bone powder embedded in boric acid solution with known boron concentrations between 0 and 100 ppm was used as a standard material. The samples, contained in slim Lexan cases, were exposed to a neutron fluence of 1012 cm-2 at the thermal column central facility of the RA-3 reactor (Argentina). The revealed tracks in the NTD were counted with an image processing software. The effect of track overlapping was studied and corresponding corrections were implemented in the presented calibration curve. Stochastic simulations of the track densities produced by the products of the 10B thermal neutron capture reaction for different boron concentrations in bone were performed and compared with the experimental results. The remarkable agreement between the two curves suggested the suitability of the obtained experimental calibration curve. This neutron autoradiography technique was finally applied to determine the boron concentration in pulverized and compact bone samples coming from a sheep experimental model. The obtained results for both type of samples agreed with boron measurements carried out by ICP-OES within experimental uncertainties. The fact that the histological structure of bone sections remains preserved allows for future boron microdistribution analysis.


Subject(s)
Autoradiography/methods , Boron/analysis , Neutrons , Animals , Autoradiography/standards , Bone and Bones/chemistry , Boron/standards , Boron Neutron Capture Therapy , Calibration , Computer Simulation , Models, Animal , Radiometry/methods , Radiometry/standards , Sheep , Stochastic Processes , Tissue Distribution
7.
Radiat Oncol ; 12(1): 130, 2017 Aug 15.
Article in English | MEDLINE | ID: mdl-28806981

ABSTRACT

BACKGROUND: Osteosarcoma is the most frequent primary malignant bone tumour, and its incidence is higher in children and adolescents, for whom it represents more than 10% of solid cancers. Despite the introduction of adjuvant and neo-adjuvant chemotherapy that markedly increased the success rate in the treatment, aggressive surgery is still needed and a considerable percentage of patients do not survive due to recurrences or early metastases. Boron Neutron Capture Therapy (BNCT), an experimental radiotherapy, was investigated as a treatment that could allow a less aggressive surgery by killing infiltrated tumour cells in the surrounding healthy tissues. BNCT requires an intense neutron beam to ensure irradiation times of the order of 1 h. In Italy, a Radio Frequency Quadrupole (RFQ) proton accelerator has been designed and constructed for BNCT, and a suitable neutron spectrum was tailored by means of Monte Carlo calculations. This paper explores the feasibility of BNCT to treat osteosarcoma using this neutron source based on accelerator. METHODS: The therapeutic efficacy of BNCT was analysed evaluating the dose distribution obtained in a clinical case of femur osteosarcoma. Mixed field dosimetry was assessed with two different formalisms whose parameters were specifically derived from radiobiological experiments involving in vitro UMR-106 osteosarcoma cell survival assays and boron concentration assessments in an animal model of osteosarcoma. A clinical case of skull osteosarcoma treated with BNCT in Japan was re-evaluated from the point of view of dose calculation and used as a reference for comparison. RESULTS: The results in the case of femur osteosarcoma show that the RFQ beam would ensure a suitable tumour dose painting in a total irradiation time of less than an hour. Comparing the dosimetry between the analysed case and the treated patient in Japan it turns out that doses obtained in the femur tumour are at least as good as the ones delivered in the skull osteosarcoma. The same is concluded when the comparison is carried out taking into account osteosarcoma irradiations with photon radiation therapy. CONCLUSIONS: The possibility to apply BNCT to osteosarcoma would allow a multimodal treatment consisting in neo-adjuvant chemotherapy, high-LET selective radiation treatment and a more conservative surgery.


Subject(s)
Bone Neoplasms/radiotherapy , Boron Neutron Capture Therapy/methods , Osteosarcoma/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Adolescent , Animals , Humans , Male , Radiometry , Rats
8.
Appl Radiat Isot ; 88: 171-6, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24373821

ABSTRACT

From 2008 to 2011, several planned modifications were implemented at the RA-6 reactor in Argentina, leading to significant benefits for future BNCT treatments. New capabilities have been implemented in NCTPlan treatment planning system. To assess the performance of the new BNCT facility, a dosimetric reevaluation of previous clinical cases was performed, taking into account the modifications carried out in the new facility and compared the results of the original treatment plans with optimized plans that are considered as feasible patient setups.


Subject(s)
Boron Neutron Capture Therapy/standards , Patient Positioning/standards , Quality Assurance, Health Care , Quality Improvement/standards , Radiometry/standards , Radiotherapy Planning, Computer-Assisted/standards , Radiotherapy Setup Errors/prevention & control , Argentina , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...