Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Radiol Artif Intell ; 3(4): e200190, 2021 Jul.
Article in English | MEDLINE | ID: mdl-34350409

ABSTRACT

PURPOSE: To assess the generalizability of a deep learning pneumothorax detection model on datasets from multiple external institutions and examine patient and acquisition factors that might influence performance. MATERIALS AND METHODS: In this retrospective study, a deep learning model was trained for pneumothorax detection by merging two large open-source chest radiograph datasets: ChestX-ray14 and CheXpert. It was then tested on six external datasets from multiple independent institutions (labeled A-F) in a retrospective case-control design (data acquired between 2016 and 2019 from institutions A-E; institution F consisted of data from the MIMIC-CXR dataset). Performance on each dataset was evaluated by using area under the receiver operating characteristic curve (AUC) analysis, sensitivity, specificity, and positive and negative predictive values, with two radiologists in consensus being used as the reference standard. Patient and acquisition factors that influenced performance were analyzed. RESULTS: The AUCs for pneumothorax detection for external institutions A-F were 0.91 (95% CI: 0.88, 0.94), 0.97 (95% CI: 0.94, 0.99), 0.91 (95% CI: 0.85, 0.97), 0.98 (95% CI: 0.96, 1.0), 0.97 (95% CI: 0.95, 0.99), and 0.92 (95% CI: 0.90, 0.95), respectively, compared with the internal test AUC of 0.93 (95% CI: 0.92, 0.93). The model had lower performance for small compared with large pneumothoraces (AUC, 0.88 [95% CI: 0.85, 0.91] vs AUC, 0.96 [95% CI: 0.95, 0.97]; P = .005). Model performance was not different when a chest tube was present or absent on the radiographs (AUC, 0.95 [95% CI: 0.92, 0.97] vs AUC, 0.94 [95% CI: 0.92, 0.05]; P > .99). CONCLUSION: A deep learning model trained with a large volume of data on the task of pneumothorax detection was able to generalize well to multiple external datasets with patient demographics and technical parameters independent of the training data.Keywords: Thorax, Computer Applications-Detection/DiagnosisSee also commentary by Jacobson and Krupinski in this issue.Supplemental material is available for this article.©RSNA, 2021.

2.
AJR Am J Roentgenol ; 213(6): 1291-1296, 2019 12.
Article in English | MEDLINE | ID: mdl-31573848

ABSTRACT

OBJECTIVE. This study aims to compare the diagnostic accuracy of virtual unenhanced CT images derived from dual-source dual-energy contrast-enhanced CT with that of standard unenhanced CT images for evaluation of sialolithiasis. MATERIALS AND METHODS. All dual-energy CT studies of the neck performed during the preceding 5 years were reviewed for submandibular gland calculi. Only patients who had unenhanced CT and contrast-enhanced CT performed as part of the same evaluation were included in this study. This review yielded 30 patients. Virtual unenhanced CT images were derived from the dual-energy dataset and compared with the true unenhanced CT images by two separate radiologists who assessed the total number of calculi encountered, their location, the largest dimension, and the attenuation of the calculi. The radiation burden incurred for true unenhanced CT and virtual unenhanced CT and the total radiation burden were calculated. RESULTS. Our analysis revealed that measurements of stone size showed good interobserver agreement. The mean stone size was 7.9 ± 5.9 (SD) mm on virtual unenhanced CT and 8.4 ± 5.9 mm on true unenhanced CT (range, 2.0-31.8 mm); the difference was statistically insignificant. The mean stone attenuation differed considerably (p < 0.01) between the virtual and true unenhanced CT images (494.8 ± 187.5 HU and 924.4 ± 374.9 HU, respectively), but correlated well. The mean radiation dose for a dual-phase IV contrast-enhanced CT study was 23.13 mGy (volume CT dose index). The mean dose was 10.93 mGy for the true unenhanced CT phase, thereby suggesting a 47.25% reduction in administered radiation dose when a single-phase contrast-enhanced CT study with virtual unenhanced image reconstructions is performed. CONCLUSION. Virtual unenhanced CT images derived from dual-source dual-energy CT scans of the neck provide accurate assessment of sialolithiasis akin to that provided by conventional CT protocols but at only a fraction of the radiation dosage.


Subject(s)
Radiography, Dual-Energy Scanned Projection/methods , Salivary Gland Calculi/diagnostic imaging , Submandibular Gland/diagnostic imaging , Adolescent , Adult , Contrast Media , Female , Humans , Iohexol , Male , Middle Aged , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted , Reproducibility of Results , Retrospective Studies , Tomography, X-Ray Computed/methods
3.
Eur J Radiol ; 110: 74-80, 2019 Jan.
Article in English | MEDLINE | ID: mdl-30599877

ABSTRACT

Conductive hearing loss (CHL) commonly results from middle ear fluid and inflammation (otitis media). Less commonly in patients with CHL, the middle ear cleft is well aerated or 'dry' with absence of soft tissue or fluid clinically and on imaging. There are numerous causes for this but they can be clinically challenging to diagnose. This pictorial review aims to illustrate and discuss the CT features of both common and less common causes of CHL in patients with a "dry middle ear cavity".


Subject(s)
Ear, Middle/diagnostic imaging , Hearing Loss, Conductive/etiology , Adolescent , Adult , Aged , Ear Ossicles/abnormalities , Ear Ossicles/diagnostic imaging , Ear Ossicles/injuries , Female , Hearing Loss, Conductive/diagnostic imaging , Humans , Incus/abnormalities , Incus/diagnostic imaging , Labyrinthitis/complications , Labyrinthitis/diagnostic imaging , Male , Middle Aged , Myringosclerosis/complications , Myringosclerosis/diagnostic imaging , Otosclerosis/complications , Otosclerosis/diagnostic imaging , Postoperative Complications/diagnostic imaging , Postoperative Complications/etiology , Stapes Surgery/adverse effects , Tomography, X-Ray Computed , Tympanic Membrane/abnormalities
4.
Eur J Radiol ; 102: 157-168, 2018 May.
Article in English | MEDLINE | ID: mdl-29685531

ABSTRACT

This article illustrates and discusses the applications and value of magnetic resonance imaging (MRI) in the evaluation of sinonasal disease. There are several clinical scenarios where MRI can add value over conventional computed tomography (CT) evaluation of the sinonasal spaces. Specifically, MRI can provide insight through better depiction of the anatomy of certain sinonasal sub-sites including the olfactory structures. It can aid in evaluating anosmia, sinusitis (fungal sinusitis and complications), benign and malignant lesions, CSF leaks and pathology extending into sinonasal spaces.


Subject(s)
Paranasal Sinus Diseases/pathology , Adult , Female , Humans , Magnetic Resonance Imaging/methods , Male , Middle Aged , Olfaction Disorders/pathology , Paranasal Sinuses/pathology , Sensitivity and Specificity , Sinusitis/pathology , Smell , Tomography, X-Ray Computed/methods
5.
Br J Radiol ; 90(1074): 20160859, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28291377

ABSTRACT

The increasing availability of dual-energy CT (DECT) has set the stage for an exciting era in CT technology. This technique is extensively used throughout the world with numerous centres working on the applications of DECT in various radiology subspeciality areas. DECT provides many advantages over the conventional single-energy scan. Instead of a single set of images, radiologists have access to multiple sets of images from a single acquisition. The DECT workstation enables the reader to generate images, according to the clinical setting, in order to answer a specific clinical question. Radiologists should be aware of the basic concepts of DECT and the usefulness of each image data set. This article aimed to describe the basic principles, techniques and applications of DECT in the imaging of salivary gland lesions. The specific roles of each image data set, in the context of salivary gland lesions, are also discussed.


Subject(s)
Radiography, Dual-Energy Scanned Projection , Salivary Gland Diseases/diagnostic imaging , Tomography, X-Ray Computed/methods , Contrast Media , Humans , Radiographic Image Interpretation, Computer-Assisted
6.
Intern Med ; 55(13): 1823-4, 2016.
Article in English | MEDLINE | ID: mdl-27374695
7.
Singapore Med J ; 56(9): 523-6; quiz 527, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26451056

ABSTRACT

A 28-year-old Chinese man presented with acute bleeding per rectum. Computed tomography showed a posterior outpouching arising from the distal ileum. The outpouching had hyperaemic walls, but no active contrast extravasation was detected. Technetium-99m pertechnetate scintigraphy showed focal areas of abnormal uptake in the right side of the pelvis, superior and posterior to the urinary bladder. These areas of uptake appeared simultaneously with the gastric uptake and demonstrated gradual increase in intensity on subsequent images. The diagnosis of Meckel's diverticulum was confirmed on surgery and the lesion was resected. The clinical and imaging features of Meckel's diverticulum are discussed.


Subject(s)
Meckel Diverticulum/diagnosis , Abdominal Pain , Adult , Female , Gastrointestinal Hemorrhage/diagnosis , Gastrointestinal Hemorrhage/diagnostic imaging , Humans , Ileum/diagnostic imaging , Male , Meckel Diverticulum/diagnostic imaging , Radionuclide Imaging , Radiopharmaceuticals , Sodium Pertechnetate Tc 99m , Tomography, X-Ray Computed
8.
Singapore Med J ; 55(3): e46-8, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24664394

ABSTRACT

Tension pneumocephalus is a rare but treatable neurosurgical emergency. Prompt and accurate diagnosis of tension pneumocephalus requires a high index of clinical suspicion corroborated by imaging. Herein, we describe a case of extensive tension pneumocephalus in a patient who had undergone transsphenoidal surgery and repair of the sellar floor, with subsequent successful decompression. This case report discusses the pertinent imaging features of tension pneumocephalus and its management.


Subject(s)
Pneumocephalus/diagnostic imaging , Pneumocephalus/diagnosis , Aged , Craniopharyngioma/surgery , Decompression, Surgical/methods , Humans , Male , Neurosurgical Procedures/adverse effects , Postoperative Complications , Reproducibility of Results , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL