Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-37196528

ABSTRACT

Sample clean-up with the protein precipitation solvent trichloroacetic acid (TCA), combined with a stable isotope labeled internal standard, is widely used for the analysis of endogenous and exogenous compounds in serum and plasma with liquid chromatography-tandem mass spectrometry (LC-MS/MS). During the application of an assay for methylmalonic acid (MMA), used for routine analysis in patient care, negative long-term side effects of TCA on assay performance were observed. Step-by-step extensive troubleshooting disclosed the limitations of using TCA in MS. After running over 2000 samples with the MMA assay over a course of one year, a black coating formed between the probe and the heater that was traced to the use of TCA. The MMA assay used a C18 column with an isocratic eluent of 95% water (0.1% formic acid) as starting condition, on which TCA was more retained than MMA. Next, concentrations of 2.2% TCA in the prepared serum or plasma sample caused a drop in spray voltage during ionization into the MS. This was caused by the strong acid properties of TCA, resulting in current loss of the spray voltage between the heated electrospray ionization (HESI) needle and the union holder, which had also a grounding function. Replacing the original metal HESI needle with a custom made fussed silica HESI needle or detaching the union from the union holder, eliminated the effect of the drop in spray voltage. In conclusion, TCA can seriously affect the long-term robustness by affecting the source of the MS. We recommend the use of a very low sample injection volume, and/or shifting the mobile phase to waste when TCA is eluting, when using TCA in LC-MS/MS analysis.


Subject(s)
Methylmalonic Acid , Tandem Mass Spectrometry , Humans , Chromatography, Liquid/methods , Tandem Mass Spectrometry/methods , Trichloroacetic Acid , Plasma , Spectrometry, Mass, Electrospray Ionization/methods
2.
Ther Drug Monit ; 45(6): 760-765, 2023 12 01.
Article in English | MEDLINE | ID: mdl-37199431

ABSTRACT

BACKGROUND: The clinical outcomes of busulfan-based conditioning regimens for hematopoietic cell transplantation (HCT) have been improved by personalizing the doses to target narrow busulfan plasma exposure. An interlaboratory proficiency test program for the quantitation, pharmacokinetic modeling, and busulfan dosing in plasma was developed. Previous proficiency rounds (ie, the first 2) found that 67%-85% and 71%-88% of the dose recommendations were inaccurate, respectively. METHODS: A proficiency test scheme was developed by the Dutch Foundation for Quality Assessment in Medical Laboratories (SKML) and consisted of 2 rounds per year, with each round containing 2 busulfan samples. In this study, 5 subsequent proficiency tests were evaluated. In each round, the participating laboratories reported their results for 2 proficiency samples (ie, low and high busulfan concentrations) and a theoretical case assessing their pharmacokinetic modeling and dose recommendations. Descriptive statistics were performed, with ±15% for busulfan concentrations and ±10% for busulfan plasma exposure. The dose recommendations were deemed accurate. RESULTS: Since January 2020, 41 laboratories have participated in at least 1 round of this proficiency test. Over the 5 rounds, an average of 78% of the busulfan concentrations were accurate. Area under the concentration-time curve calculations were accurate in 75%-80% of the cases, whereas only 60%-69% of the dose recommendations were accurate. Compared with the first 2 proficiency test rounds (PMID 33675302, October, 2021), the busulfan quantitation results were similar, but the dose recommendations worsened. Some laboratories repeatedly submit results that deviated by more than 15% from the reference values. CONCLUSIONS: The proficiency test showed persistent inaccuracies in busulfan quantitation, pharmacokinetic modeling, and dose recommendations. Additional educational efforts have yet to be implemented; regulatory efforts seem to be needed. The use of specialized busulfan pharmacokinetic laboratories or a sufficient performance in busulfan proficiency tests should be required for HCT centers that prescribe busulfan.


Subject(s)
Busulfan , Hematopoietic Stem Cell Transplantation , Humans , Busulfan/pharmacokinetics , Hematopoietic Stem Cell Transplantation/methods , Laboratory Proficiency Testing , Laboratories , Drug Monitoring/methods , Transplantation Conditioning/methods
3.
Ann Clin Biochem ; 59(5): 330-337, 2022 09.
Article in English | MEDLINE | ID: mdl-35392660

ABSTRACT

BACKGROUND: The peptide hormone hepcidin-25 plays an important role in iron metabolism. Low or high levels of hepcidin-25 are associated with various iron disorders; therefore, hepcidin-25 is an important biomarker. This study describes an easy and fast analytical assay for the quantification of hepcidin-25 with liquid chromatography-tandem mass spectrometry (LC-MS/MS). METHODS: Sample preparation was performed by protein precipitation with trichloroacetic acid, and injection onto a LC-MS/MS was directly conducted from a LoBind 96-well plate. RESULTS: The concentration range covered by the quality control samples, ranged from 0.25 nmol/L (12.3% CV) to 11.9 nmol/L (CV < 9%). Matrix effect was limited (mean recovery of 99.9% with a CV of 6.4%). The assay was validated for serum, EDTA and heparin plasma. An international secondary reference material was used for calibration. The reference interval (90% CL) was estimated for hepcidin-25 by analysing serum and plasma samples from 156 healthy subjects with a lower limit: 0.12 (0.07-0.19) and upper limit: 11.2 nmol/L (9.5-13.0). CONCLUSIONS: We present a fast and easy assay for the quantification of hepcidin-25 in serum and plasma samples. The assay was successfully used for the detection of various forms of hereditary haemolytic anaemias, to characterize the interplay between erythropoiesis and iron levels.


Subject(s)
Hepcidins , Peptide Hormones , Biomarkers , Chromatography, Liquid/methods , Edetic Acid , Heparin , Humans , Iron , Tandem Mass Spectrometry/methods , Trichloroacetic Acid
5.
Ther Drug Monit ; 43(5): 657-663, 2021 10 01.
Article in English | MEDLINE | ID: mdl-33675302

ABSTRACT

BACKGROUND: Personalizing busulfan doses to target a narrow plasma exposure has improved the efficacy and lowered the toxicity of busulfan-based conditioning regimens used in hematopoietic cell transplant. Regional regulations guide interlaboratory proficiency testing for busulfan concentration quantification and monitoring. To date, there have been no comparisons of the busulfan pharmacokinetic modeling and dose recommendation protocols used in these laboratories. Here, in collaboration with the Dutch Association for Quality Assessment in Therapeutic Drug Monitoring and Clinical Toxicology, a novel interlaboratory proficiency program for the quantitation in plasma, pharmacokinetic modeling, and dosing of busulfan was designed. The methods and results of the first 2 rounds of this proficiency testing are described herein. METHODS: A novel method was developed to stabilize busulfan in N,N-dimethylacetamide, which allowed shipping of the proficiency samples without dry ice. In each round, participating laboratories reported their results for 2 proficiency samples (one low and one high busulfan concentrations) and a theoretical case assessing their pharmacokinetic modeling and dose recommendations. All participants were blinded to the answers; descriptive statistics were used to evaluate their overall performance. The guidelines suggested that answers within ±15% for busulfan concentrations and ±10% for busulfan plasma exposure and dose recommendation were to be considered accurate. RESULTS: Of the 4 proficiency samples evaluated, between 67% and 85% of the busulfan quantitation results were accurate (ie, within 85%-115% of the reference value). The majority (88% round #1; 71% round #2) of the dose recommendation answers were correct. CONCLUSIONS: A proficiency testing program by which laboratories are alerted to inaccuracies in their quantitation, pharmacokinetic modeling, and dose recommendations for busulfan in hematopoietic cell transplant recipients was developed. These rounds of proficiency testing suggests that additional educational efforts and proficiency rounds are needed to ensure appropriate busulfan dosing.


Subject(s)
Busulfan , Hematopoietic Stem Cell Transplantation , Busulfan/blood , Busulfan/pharmacokinetics , Humans , Laboratory Proficiency Testing , Quality Control , Transplantation Conditioning
6.
Pediatr Blood Cancer ; 67(4): e28133, 2020 04.
Article in English | MEDLINE | ID: mdl-31876116

ABSTRACT

BACKGROUND: The aim of this study was to improve the predictive power of patient-derived xenografts (PDXs, also known as mouse avatars) to more accurately reflect outcomes of clofarabine-based treatment in pediatric acute lymphoblastic leukemia (ALL) patients. PROCEDURE: Pharmacokinetic (PK) studies were conducted using clofarabine at 3.5 to 15 mg/kg in mice. PDXs were established from relapsed/refractory ALL patients who exhibited good or poor responses to clofarabine. PDX engraftment and response to clofarabine (either as a single agent or in combinations) were assessed based on stringent objective response measures modeled after the clinical setting. RESULTS: In naïve immune-deficient NSG mice, we determined that a clofarabine dose of 3.5 mg/kg resulted in systemic exposures equivalent to those achieved in pediatric ALL patients treated with clofarabine-based regimens. This dose was markedly lower than the doses of clofarabine used in previously reported preclinical studies (typically 30-60 mg/kg) and, when scheduled consistent with the clinical regimen (daily × 5), resulted in 34-fold lower clofarabine exposures. Using a well-tolerated clofarabine/etoposide/cyclophosphamide combination regimen, we then found that the responses of PDXs better reflected the clinical responses of the patients from whom the PDXs were derived. CONCLUSIONS: This study has identified an in vivo clofarabine treatment regimen that reflects the clinical responses of relapsed/refractory pediatric ALL patients. This regimen could be used prospectively to identify patients who might benefit from clofarabine-based treatment. Our findings are an important step toward individualizing prospective patient selection for the use of clofarabine in relapsed/refractory pediatric ALL patients and highlight the need for detailed PK evaluation in murine PDX models.


Subject(s)
Antineoplastic Combined Chemotherapy Protocols/pharmacology , Precision Medicine/methods , Precursor Cell Lymphoblastic Leukemia-Lymphoma/drug therapy , Xenograft Model Antitumor Assays , Animals , Antimetabolites, Antineoplastic/pharmacology , Clofarabine/pharmacology , Cyclophosphamide/pharmacology , Etoposide/pharmacology , Humans , Mice
7.
J Chromatogr B Analyt Technol Biomed Life Sci ; 1055-1056: 81-85, 2017 Jun 15.
Article in English | MEDLINE | ID: mdl-28445850

ABSTRACT

In allogeneic hematopoietic cell transplantation (HCT) it has been shown that over- or underexposure to conditioning agents have an impact on patient outcomes. Conditioning regimens combining busulfan (Bu) and fludarabine (Flu) with or without clofarabine (Clo) are gaining interest worldwide in HCT. To evaluate and possibly adjust full conditioning exposure a simultaneous analysis of Bu, F-ARA-A (active metabolite of Flu) and Clo in one analytical run would be of great interest. However, this is a chromatographical challenge due to the large structural differences of Bu compared to F-ARA-A and Clo. Furthermore, for the bioanalysis of drugs it is common to use stable isotope labelled standards (SILS). However, when SILS are unavailable (in case of Clo and F-ARA-A) or very expensive, standard addition may serve as an alternative to correct for recovery and matrix effects. This study describes a fast analytical method for the simultaneous analysing of Bu, Clo and F-ARA-A with liquid chromatography-tandem mass spectrometry (LC-MS/MS) including standard addition methodology using 604 spiked samples. First, the analytical method was validated in accordance with European Medicines Agency guidelines. The lower limits of quantification (LLOQ) were for Bu 10µg/L and for Clo and F-ARA-A 1µg/L, respectively. Variation coefficients of LLOQ were within 20% and for low medium and high controls were all within 15%. Comparison of Bu, Clo and F-ARA-A standard addition results correspond with those obtained with calibration standards in calf serum. In addition for Bu, results obtained by this study were compared with historical data analysed within TDM. In conclusion, an efficient method for the simultaneous quantification of Bu, Clo and F-ARA-A in plasma was developed. In addition, a robust and cost-effective method to correct for matrix interference by standard addition was established.


Subject(s)
Adenine Nucleotides/blood , Antineoplastic Agents/blood , Arabinonucleosides/blood , Busulfan/blood , Drug Monitoring/methods , Immunosuppressive Agents/blood , Tandem Mass Spectrometry/methods , Vidarabine/analogs & derivatives , Chromatography, Liquid/methods , Clofarabine , Hematopoietic Stem Cell Transplantation , Humans , Isotopes/blood , Limit of Detection , Transplantation Conditioning , Vidarabine/blood
8.
Bioresour Technol ; 216: 44-51, 2016 Sep.
Article in English | MEDLINE | ID: mdl-27233096

ABSTRACT

Thermo-assisted NaOH pretreatment to deconstruct xylan and lignin in sugar cane bagasse (SCB) is poorly understood. Hence, in this research it is was aimed to study the effect of NaOH pretreatment on the insoluble remaining lignin structures. Hereto, SCB milled fibres were pretreated using different dosages of NaOH at different temperatures and residence times. Of untreated SCB about 63% of the lignin compounds were assigned as p-coumarates and ferulates, analysed by pyrolysis-GC/MS as 4-vinyl phenol and 4-vinyl guaiacol, and designated as non-core lignin (NCL) compounds. More severe NaOH pretreatments resulted in lower xylan and lower lignin recoveries in the insoluble residues. Especially, the relative abundance of NCL decreased and this decrease followed a linear trend with the decrease in xylan. Core lignin compounds, analysed as phenol, guaiacol and syringol, accumulated in the residues. The decrease in residual xylan and NCL correlated positively with the enzymatic hydrolysis of the residual glucan.


Subject(s)
Cellulose/chemistry , Lignin/chemistry , Refuse Disposal/methods , Saccharum/chemistry , Glucans/chemistry , Hydrolysis , Xylans/chemistry
9.
PLoS One ; 10(10): e0138909, 2015.
Article in English | MEDLINE | ID: mdl-26436656

ABSTRACT

In wheat straw based composting, enabling growth of Agaricus bisporus mushrooms, it is unknown to which extent the carbohydrate-lignin matrix changes and how much is metabolized. In this paper we report yields and remaining structures of the major components. During the Phase II of composting 50% of both xylan and cellulose were metabolized by microbial activity, while lignin structures were unaltered. During A. bisporus' mycelium growth (Phase III) carbohydrates were only slightly consumed and xylan was found to be partially degraded. At the same time, lignin was metabolized for 45% based on pyrolysis GC/MS. Remaining lignin was found to be modified by an increase in the ratio of syringyl (S) to guaiacyl (G) units from 0.5 to 0.7 during mycelium growth, while fewer decorations on the phenolic skeleton of both S and G units remained.


Subject(s)
Agaricus/growth & development , Agaricus/metabolism , Carbohydrate Metabolism , Lignin/metabolism , Mycelium/growth & development , Soil/chemistry , Triticum/chemistry , Mycelium/metabolism , Plant Proteins/metabolism , Soil Microbiology
SELECTION OF CITATIONS
SEARCH DETAIL