1.
Physiol Meas ; 45(3)2024 Mar 11.
Article in English | MEDLINE | ID: mdl-38387061

ABSTRACT

Objective. Although inter-beat intervals (IBI) and the derived heart rate variability (HRV) can be acquired through consumer-grade photoplethysmography (PPG) wristbands and have been applied in a variety of physiological and psychophysiological conditions, their accuracy is still unsatisfactory.Approach.In this study, 30 healthy participants concurrently wore two wristbands (E4 and Honor 5) and a gold-standard electrocardiogram (ECG) device under four conditions: resting, deep breathing with a frequency of 0.17 Hz and 0.1 Hz, and mental stress tasks. To quantitatively validate the accuracy of IBI acquired from PPG wristbands, this study proposed to apply an information-based similarity (IBS) approach to quantify the pattern similarity of the underlying dynamical temporal structures embedded in IBI time series simultaneously recorded using PPG wristbands and the ECG system. The occurrence frequency of basic patterns and their rankings were analyzed to calculate the IBS distance from gold-standard IBI, and to further calculate the signal-to-noise ratio (SNR) of the wristband IBI time series.Main results.The accuracies of both HRV and mental state classification were not satisfactory due to the low SNR in the wristband IBI. However, by rejecting data segments of SNR < 25, the Pearson correlation coefficients between the wristbands' HRV and the gold-standard HRV were increased from 0.542 ± 0.235 to 0.922 ± 0.120 for E4 and from 0.596 ± 0.227 to 0.859 ± 0.145 for Honor 5. The average accuracy of four-class mental state classification increased from 77.3% to 81.9% for E4 and from 79.3% to 83.3% for Honor 5.Significance.Consumer-grade PPG wristbands are acceptable for HR and HRV monitoring when removing low SNR segments. The proposed method can be applied for quantifying the accuracies of IBI and HRV indices acquired via any non-ECG system.


Subject(s)
Heart Rate Determination , Photoplethysmography , Humans , Photoplethysmography/methods , Heart Rate/physiology , Monitoring, Physiologic , Electrocardiography/methods
2.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 40(6): 1093-1101, 2023 Dec 25.
Article in Chinese | MEDLINE | ID: mdl-38151931

ABSTRACT

Rapid and accurate identification and effective non-drug intervention are the worldwide challenges in the field of depression. Electroencephalogram (EEG) signals contain rich quantitative markers of depression, but whole-brain EEG signals acquisition process is too complicated to be applied on a large-scale population. Based on the wearable frontal lobe EEG monitoring device developed by the authors' laboratory, this study discussed the application of wearable EEG signal in depression recognition and intervention. The technical principle of wearable EEG signals monitoring device and the commonly used wearable EEG devices were introduced. Key technologies for wearable EEG signals-based depression recognition and the existing technical limitations were reviewed and discussed. Finally, a closed-loop brain-computer music interface system for personalized depression intervention was proposed, and the technical challenges were further discussed. This review paper may contribute to the transformation of relevant theories and technologies from basic research to application, and further advance the process of depression screening and personalized intervention.


Subject(s)
Music Therapy , Music , Wearable Electronic Devices , Humans , Algorithms , Depression/diagnosis , Depression/therapy , Electroencephalography
3.
Sensors (Basel) ; 22(5)2022 Feb 28.
Article in English | MEDLINE | ID: mdl-35271044

ABSTRACT

The demand for non-laboratory and long-term EEG acquisition in scientific and clinical applications has put forward new requirements for wearable EEG devices. In this paper, a new wearable frontal EEG device called Mindeep was proposed. A signal quality study was then conducted, which included simulated signal tests and signal quality comparison experiments. Simulated signals with different frequencies and amplitudes were used to test the stability of Mindeep's circuit, and the high correlation coefficients (>0.9) proved that Mindeep has a stable and reliable hardware circuit. The signal quality comparison experiment, between Mindeep and the gold standard device, Neuroscan, included three tasks: (1) resting; (2) auditory oddball; and (3) attention. In the resting state, the average normalized cross-correlation coefficients between EEG signals recorded by the two devices was around 0.72 ± 0.02, Berger effect was observed (p < 0.01), and the comparison results in the time and frequency domain illustrated the ability of Mindeep to record high-quality EEG signals. The significant differences between high tone and low tone in auditory event-related potential collected by Mindeep was observed in N2 and P2. The attention recognition accuracy of Mindeep achieved 71.12% and 74.76% based on EEG features and the XGBoost model in the two attention tasks, respectively, which were higher than that of Neuroscan (70.19% and 72.80%). The results validated the performance of Mindeep as a prefrontal EEG recording device, which has a wide range of potential applications in audiology, cognitive neuroscience, and daily requirements.


Subject(s)