Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Lancet Reg Health Eur ; 41: 100913, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38737571

ABSTRACT

Background: Invasive pneumococcal disease due to serotype 3 (S3-IPD) is associated with high mortality rates and long-term adverse effects. The introduction of the 13-valent pneumococcal conjugate vaccine (PCV13) into the Spanish paediatric immunisation programme has not led to a decrease in the adult S3-IPD. We aimed to analyse the incidence, clinical characteristics and genomics of S3-IPD in adults in Spain. Methods: Adult IPD episodes hospitalized in a Southern Barcelona hospital were prospectively collected (1994-2020). For genomic comparison, S3-IPD isolates from six Spanish hospitals (2008-2020) and historical isolates (1989-1993) were analysed by WGS (Illumina and/or MinION). Findings: From 1994 to 2020, 270 S3-IPD episodes were detected. When comparing pre-PCV (1994-2001) and late-PCV13 (2016-2020) periods, only modest changes in S3-IPD were observed (from 1.58 to 1.28 episodes per 100,000 inhabitants year). In this period, the incidence of the two main lineages shifted from 0.38 to 0.67 (CC180-GPSC12) and from 1.18 to 0.55 (CC260-GPSC83). The overall 30-day mortality remained high (24.1%), though a decrease was observed between the pre-PCV (32.4%; 95.0% CI, 22.0-45.0) and the late-PCV13 period (16.7%; 95.0% CI, 7.5-32.0) (p = 0.06). At the same time, comorbidities increased from 77.3% (95.0% CI, 65.0-86.0) to 85.7% (95.0% CI, 71.0-94.0) (p = 0.69). There were no differences in clinical characteristics or 30-day mortality between the two S3 lineages. Although both lineages were genetically homogeneous, the CC180-GPSC12 lineage presented a higher SNP density, a more open pan-genome, and a major presence of prophages and mobile genetic elements carrying resistance genes. Interpretation: Adult S3-IPD remained stable in our area over the study period despite PCV13 introduction in children. However, a clonal shift was observed. The decrease in mortality rates and the increase in comorbidities suggest a change in clinical management and overall population characteristics. The low genetic variability and absence of clinical differences between lineages highlight the role of the S3 capsule in the disease severity. Funding: This study has been funded by Instituto de Salud Carlos III (ISCIII) "PI18/00339", "PI21/01000", "INT22/00096", "FI22/00279", CIBER "CIBERES-CB06/06/0037", "CIBERINFEC-CB21/13/00009" and MSD grant "IISP 60168".

2.
PLoS One ; 10(10): e0140865, 2015.
Article in English | MEDLINE | ID: mdl-26474394

ABSTRACT

BACKGROUND: Rapid identification of the etiological agent in bloodstream infections is of vital importance for the early administration of the most appropriate antibiotic therapy. Molecular methods may offer an advantage to current culture-based microbiological diagnosis. The goal of this study was to evaluate the performance of IRIDICA, a platform based on universal genetic amplification followed by mass spectrometry (PCR/ESI-MS) for the molecular diagnosis of sepsis-related pathogens directly from the patient's blood. METHODS: A total of 410 whole blood specimens from patients admitted to Emergency Room (ER) and Intensive Care Unit (ICU) with clinical suspicion of sepsis were tested with the IRIDICA BAC BSI Assay (broad identification of bacteria and Candida spp.). Microorganisms grown in culture and detected by IRIDICA were compared considering blood culture as gold standard. When discrepancies were found, clinical records and results from other cultures were taken into consideration (clinical infection criterion). RESULTS: The overall positive and negative agreement of IRIDICA with blood culture in the analysis by specimen was 74.8% and 78.6%, respectively, rising to 76.9% and 87.2% respectively, when compared with the clinical infection criterion. Interestingly, IRIDICA detected 41 clinically significant microorganisms missed by culture, most of them from patients under antimicrobial treatment. Of special interest were the detections of one Mycoplasma hominis and two Mycobacterium simiae in immunocompromised patients. When ICU patients were analyzed separately, sensitivity, specificity, positive and negative predictive values compared with blood culture were 83.3%, 78.6%, 33.9% and 97.3% respectively, and 90.5%, 87.2%, 64.4% and 97.3% respectively, in comparison with the clinical infection criterion. CONCLUSIONS: IRIDICA is a promising technology that offers an early and reliable identification of a wide variety of pathogens directly from the patient's blood within 6h, which brings the opportunity to improve management of septic patients, especially for those critically ill admitted to the ICU.


Subject(s)
Blood/microbiology , Molecular Diagnostic Techniques/methods , Polymerase Chain Reaction/methods , Sepsis/blood , Sepsis/diagnosis , Spectrometry, Mass, Electrospray Ionization/methods , Adolescent , Adult , Aged , Aged, 80 and over , Anti-Bacterial Agents/pharmacology , Drug Resistance, Bacterial/genetics , Emergency Service, Hospital , Female , Humans , Intensive Care Units , Male , Middle Aged , Sepsis/microbiology , Young Adult
4.
Biomed Res Int ; 2014: 501214, 2014.
Article in English | MEDLINE | ID: mdl-24818144

ABSTRACT

The reference method for the diagnosis of bloodstream infections is blood culture followed by biochemical identification and antibiotic susceptibility testing of the isolated pathogen. This process requires 48 to 72 hours. The rapid administration of the most appropriate antimicrobial treatment is crucial for the survival of septic patients; therefore, a rapid method that enables diagnosis directly from analysis of a blood sample without culture is needed. A recently developed platform that couples broad-range PCR amplification of pathogen DNA with electrospray ionization mass spectrometry (PCR/ESI-MS) has the ability to identify virtually any microorganism from direct clinical specimens. To date, two clinical evaluations of the PCR/ESI-MS technology for the diagnosis of bloodstream infections from whole blood have been published. Here we discuss them and describe recent improvements that result in an enhanced sensitivity. Other commercially available assays for the molecular diagnosis of bloodstream infections from whole blood are also reviewed. The use of highly sensitive molecular diagnostic methods in combination with conventional procedures could substantially improve the management of septic patients.


Subject(s)
Bacterial Infections/blood , Bacterial Infections/diagnosis , Mass Spectrometry/methods , Polymerase Chain Reaction/methods , Animals , Humans , Molecular Diagnostic Techniques , Reagent Kits, Diagnostic
5.
PLoS One ; 8(4): e62108, 2013.
Article in English | MEDLINE | ID: mdl-23626775

ABSTRACT

Achieving a rapid microbiological diagnosis is crucial for decreasing morbidity and mortality of patients with a bloodstream infection, as it leads to the administration of an appropriate empiric antimicrobial therapy. Molecular methods may offer a rapid alternative to conventional microbiological diagnosis involving blood culture. In this study, the performance of a new technology that uses broad-spectrum PCR coupled with mass spectrometry (PCR/ESI-MS) was evaluated for the detection of microorganisms directly from whole blood. A total of 247 whole blood samples and paired blood cultures were prospectively obtained from 175 patients with a suspicion of sepsis. Both sample types were analyzed using the PCR/ESI-MS technology, and the results were compared with those obtained by conventional identification methods. The overall agreement between conventional methods and PCR/ESI-MS performed in blood culture aliquots was 94.2% with 96.8% sensitivity and 98.5% specificity for the molecular method. When comparing conventional methods with PCR/ESI-MS performed in whole blood specimens, the overall agreement was 77.1% with 50% sensitivity and 93.8% specificity for the molecular method. Interestingly, the PCR/ESI-MS technology led to the additional identification of 13 pathogens that were not found by conventional methods. Using the PCR/ESI-MS technology the microbiological diagnosis of bloodstream infections could be anticipated in about half of the patients in our setting, including a small but significant proportion of patients newly diagnosed. Thus, this promising technology could be very useful for the rapid diagnosis of sepsis in combination with traditional methods.


Subject(s)
Mass Spectrometry , Polymerase Chain Reaction , Sepsis/diagnosis , Adolescent , Adult , Aged , Aged, 80 and over , Bacteria/isolation & purification , Child , Child, Preschool , Female , Fungi/isolation & purification , Humans , Infant , Male , Mass Spectrometry/methods , Microbiological Techniques , Middle Aged , Polymerase Chain Reaction/methods , Reproducibility of Results , Sensitivity and Specificity , Sepsis/microbiology , Young Adult
6.
J Clin Microbiol ; 43(12): 6091-7, 2005 Dec.
Article in English | MEDLINE | ID: mdl-16333103

ABSTRACT

A study was performed to diagnose tuberculosis by smear, culture, and nucleic acid amplification. The study was comprised of two independent arms. Each arm used a different specimen processing method; in one arm, all specimens were processed with N-acetyl-l-cysteine-sodium hydroxide, and in the other arm, all specimens were processed with C(18)-carboxypropylbetaine and lytic enzymes. In each arm, all processed sediments were split for analysis by auramine smear, by culture using the MB/BacT liquid culture system and solid media, and by nucleic acid amplification using the COBAS AMPLICOR MTB test. In the N-acetyl-l-cysteine-sodium hydroxide arm, 1,468 specimens were analyzed: 65 were smear positive; 88 and 42 were culture positive for Mycobacterium tuberculosis and nontuberculous mycobacteria, respectively; and 103 were PCR positive. Relative to cultures positive for M. tuberculosis, the sensitivity and specificity of the smear were 68.2% and 99.6%, respectively, and those of PCR were 75.0% and 97.3%, respectively. In the C(18)-carboxypropylbetaine study arm, 1,423 specimens were analyzed: 44 were smear positive; 82 and 31 were culture positive for M. tuberculosis and nontuberculous mycobacteria, respectively; and 91 were PCR positive. The sensitivity and specificity of the smear were 48.8% and 99.7%, respectively, and those of PCR were 78.0% and 98.0%, respectively. When the two arms were compared, C(18)-carboxypropylbetaine specimen processing significantly increased the number of smear-negative and culture-positive specimens and significantly increased the PCR sensitivity among this same group of specimens while at the same time significantly reducing the inhibition rate.


Subject(s)
Betaine/analogs & derivatives , Mycobacterium tuberculosis/isolation & purification , Reagent Kits, Diagnostic , Sodium Hydroxide/pharmacology , Specimen Handling/methods , Tuberculosis/diagnosis , Anti-Infective Agents , Bacteriological Techniques , Benzophenoneidum , Betaine/pharmacology , Culture Media , Humans , Mycobacterium tuberculosis/genetics , Mycobacterium tuberculosis/growth & development , Nucleic Acid Amplification Techniques/methods , Polymerase Chain Reaction/methods , Sensitivity and Specificity , Sputum/microbiology , Tuberculosis/microbiology
SELECTION OF CITATIONS
SEARCH DETAIL
...