Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Rev E ; 109(2-2): 025201, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38491621

ABSTRACT

Proton bunches with maximum energies between 12 and 22 MeV were emitted from submicrometer-thin plastic foils upon irradiation by laser pulses with peak intensity of 4×10^{20}W/cm^{2}. The images of the protons by a magnetic quadrupole doublet on a screen remained consistently larger by a factor of 10 compared to expectations drawn from the ultralow transverse emittance values reported for thick foil targets. Analytic estimates and particle-in-cell simulations attribute this drastically increased emittance to formerly excluded Coulomb collisions between charged particles. The presence of carbon ions and significant transparency likely play a decisive role. This observation is highly relevant because such thin, partially transparent foils are considered ideal for optimizing maximum proton energies.

2.
Rev Sci Instrum ; 91(6): 063303, 2020 Jun 01.
Article in English | MEDLINE | ID: mdl-32611048

ABSTRACT

The development from single shot basic laser plasma interaction research toward experiments in which repetition rated laser-driven ion sources can be applied requires technological improvements. For example, in the case of radio-biological experiments, irradiation duration and reproducible controlled conditions are important for performing studies with a large number of samples. We present important technological advancements of recent years at the ATLAS 300 laser in Garching near Munich since our last radiation biology experiment. Improvements range from target positioning over proton transport and diagnostics to specimen handling. Exemplarily, we show the current capabilities by performing an application oriented experiment employing the zebrafish embryo model as a living vertebrate organism for laser-driven proton irradiation. The size, intensity, and energy of the laser-driven proton bunches resulted in evaluable partial body changes in the small (<1 mm) embryos, confirming the feasibility of the experimental system. The outcomes of this first study show both the appropriateness of the current capabilities and the required improvements of our laser-driven proton source for in vivo biological experiments, in particular the need for accurate, spatially resolved single bunch dosimetry and image guidance.


Subject(s)
Acceleration , Embryo, Nonmammalian/radiation effects , Lasers , Protons , Radiobiology/methods , Zebrafish/embryology , Animals , Feasibility Studies
3.
Sci Rep ; 9(1): 6714, 2019 04 30.
Article in English | MEDLINE | ID: mdl-31040311

ABSTRACT

The shape of a wave carries all information about the spatial and temporal structure of its source, given that the medium and its properties are known. Most modern imaging methods seek to utilize this nature of waves originating from Huygens' principle. We discuss the retrieval of the complete kinetic energy distribution from the acoustic trace that is recorded when a short ion bunch deposits its energy in water. This novel method, which we refer to as Ion-Bunch Energy Acoustic Tracing (I-BEAT), is a refinement of the ionoacoustic approach. With its capability of completely monitoring a single, focused proton bunch with prompt readout and high repetition rate, I-BEAT is a promising approach to meet future requirements of experiments and applications in the field of laser-based ion acceleration. We demonstrate its functionality at two laser-driven ion sources for quantitative online determination of the kinetic energy distribution in the focus of single proton bunches.

4.
Rev Sci Instrum ; 89(12): 123302, 2018 Dec.
Article in English | MEDLINE | ID: mdl-30599609

ABSTRACT

A common approach for spectrum determination of polyenergetic proton bunches from laser-ion acceleration experiments is based on the time-of-flight (TOF) method. However, spectra obtained using this method are typically given in relative units or are estimated based on some prior assumptions on the energy distribution of the accelerated ions. In this work, we present a new approach using the TOF method that allows for an absolute energy spectrum reconstruction from a current signal acquired with a sub-nanosecond fast and 10 µm thin silicon detector. The reconstruction is based on solving a linear least-squares problem, taking into account the response function of the detection system. The general principle of signal generation and spectrum reconstruction by setting up an appropriate system response matrix is presented. Proof-of-principle experiments at a 12 MV Tandem accelerator using different nanosecond-short (quasi-)monoenergetic and polyenergetic proton bunches at energies up to 20 MeV were successfully performed. Within the experimental uncertainties of 2.4% and 12.1% for energy and particle number, respectively, reconstructed energy distributions were found in excellent agreement with the spectra calculated using Monte Carlo simulations and measured by a magnetic spectrometer. This TOF method can hence be used for absolute online spectrometry of laser-accelerated particle bunches.

SELECTION OF CITATIONS
SEARCH DETAIL
...