1.
Science ; 353(6300): 669-73, 2016 Aug 12.
Article in English | MEDLINE | ID: mdl-27516595

ABSTRACT

The deuteron is the simplest compound nucleus, composed of one proton and one neutron. Deuteron properties such as the root-mean-square charge radius rd and the polarizability serve as important benchmarks for understanding the nuclear forces and structure. Muonic deuterium µd is the exotic atom formed by a deuteron and a negative muon µ(-). We measured three 2S-2P transitions in µd and obtain r(d) = 2.12562(78) fm, which is 2.7 times more accurate but 7.5σ smaller than the CODATA-2010 value r(d) = 2.1424(21) fm. The µd value is also 3.5σ smaller than the r(d) value from electronic deuterium spectroscopy. The smaller r(d), when combined with the electronic isotope shift, yields a "small" proton radius r(p), similar to the one from muonic hydrogen, amplifying the proton radius puzzle.

2.
Science ; 339(6118): 417-20, 2013 Jan 25.
Article in English | MEDLINE | ID: mdl-23349284

ABSTRACT

Accurate knowledge of the charge and Zemach radii of the proton is essential, not only for understanding its structure but also as input for tests of bound-state quantum electrodynamics and its predictions for the energy levels of hydrogen. These radii may be extracted from the laser spectroscopy of muonic hydrogen (µp, that is, a proton orbited by a muon). We measured the 2S(1/2)(F=0)-2P(3/2)(F=1) transition frequency in µp to be 54611.16(1.05) gigahertz (numbers in parentheses indicate one standard deviation of uncertainty) and reevaluated the 2S(1/2)(F=1)-2P(3/2)(F=2) transition frequency, yielding 49881.35(65) gigahertz. From the measurements, we determined the Zemach radius, r(Z) = 1.082(37) femtometers, and the magnetic radius, r(M) = 0.87(6) femtometer, of the proton. We also extracted the charge radius, r(E) = 0.84087(39) femtometer, with an order of magnitude more precision than the 2010-CODATA value and at 7σ variance with respect to it, thus reinforcing the proton radius puzzle.

3.
Nature ; 466(7303): 213-6, 2010 Jul 08.
Article in English | MEDLINE | ID: mdl-20613837

ABSTRACT

The proton is the primary building block of the visible Universe, but many of its properties-such as its charge radius and its anomalous magnetic moment-are not well understood. The root-mean-square charge radius, r(p), has been determined with an accuracy of 2 per cent (at best) by electron-proton scattering experiments. The present most accurate value of r(p) (with an uncertainty of 1 per cent) is given by the CODATA compilation of physical constants. This value is based mainly on precision spectroscopy of atomic hydrogen and calculations of bound-state quantum electrodynamics (QED; refs 8, 9). The accuracy of r(p) as deduced from electron-proton scattering limits the testing of bound-state QED in atomic hydrogen as well as the determination of the Rydberg constant (currently the most accurately measured fundamental physical constant). An attractive means to improve the accuracy in the measurement of r(p) is provided by muonic hydrogen (a proton orbited by a negative muon); its much smaller Bohr radius compared to ordinary atomic hydrogen causes enhancement of effects related to the finite size of the proton. In particular, the Lamb shift (the energy difference between the 2S(1/2) and 2P(1/2) states) is affected by as much as 2 per cent. Here we use pulsed laser spectroscopy to measure a muonic Lamb shift of 49,881.88(76) GHz. On the basis of present calculations of fine and hyperfine splittings and QED terms, we find r(p) = 0.84184(67) fm, which differs by 5.0 standard deviations from the CODATA value of 0.8768(69) fm. Our result implies that either the Rydberg constant has to be shifted by -110 kHz/c (4.9 standard deviations), or the calculations of the QED effects in atomic hydrogen or muonic hydrogen atoms are insufficient.

4.
Appl Opt ; 48(16): 2966-78, 2009 Jun 01.
Article in English | MEDLINE | ID: mdl-19488107

ABSTRACT

The design of a high finesse optical cavity made from two prism retroreflectors is fully described. Optical beam propagation calculations to determine the specification of prism angles and relative dimensions, the size of the astigmatic TEM00 beam as it propagates in the cavity, and the sensitivity of the optic axis to changes in prism alignment and fabrication errors are presented. The effects of material dispersion are also quantified for three different materials: fused silica, calcium fluoride, and barium fluoride. The predictions made are found to be in good agreement with experimental results obtained from prisms we had made from fused silica. Prisms made of CaF2 and BaF2 are predicted to be useful for applications in the UV and mid-IR spectral regions, respectively.

5.
Opt Lett ; 29(12): 1339-41, 2004 Jun 15.
Article in English | MEDLINE | ID: mdl-15233428

ABSTRACT

Biconical tapered single-mode fiber, which is common in many telecommunications components, offers an alternative sensor to typical optical fiber strain gauges that are susceptible to temperature and pressure effects and require expensive and sophisticated signal acquisition systems. Cavity ringdown spectroscopy, a technique commonly applied to high-sensitivity chemical analysis, offers detection sensitivity advantages that can be used to improve strain measurement with biconical tapers. Combining these two technologies in a spatially extended resonator, we demonstrate a minimum detectable change in ringdown time of 0.08%, corresponding to a minimum detectable displacement of 4.8 nm, and a sensitivity to strain as small as 79 n epsilon/square root(Hz) over a 5-mm taper length.

6.
Anal Chem ; 75(17): 4599-605, 2003 Sep 01.
Article in English | MEDLINE | ID: mdl-14632070

ABSTRACT

We have developed an instrument to measure trace concentrations of small hydride species in gases using continuous-wave cavity ring-down spectroscopy with near-infrared diode laser excitation. An rms baseline equivalent absorbance of 9.2 x 10(-11) cm(-1)/square root(n) is found, where n is the number of ring-down transients. When the 1396.376-nm absorption line of water is used, this corresponds to a noise equivalent moisture concentration in nitrogen gas of 68 pptv/square root(n). Water vapor concentration is detected over a range extending from 3 to 1000 ppbv and found to depend linearly on the concentration as determined by a calibrated commercial moisture sensor.