1.
Curr Med Imaging ; 20: e050423215451, 2024.
Article in English | MEDLINE | ID: mdl-37038668

ABSTRACT

BACKGROUND: Transvaginal and transabdominal ultrasonography has become a widely used investigative method in the diagnostic workup of endometriosis, as well as for the postoperative follow-up. The variety of lesions, the distorted anatomy caused by adhesions and the fibrosis process represent the main challenges of the ultrasound evaluation. Regarding the recurrence of endometriosis, the diagnostic criteria are being imprecise, being adjusted according to the development of ultrasound techniques. OBJECTIVE AND METHODS: To this study, extensive research has been performed interrogating PubMed, Embase and Web of Science databases to identify published research including patients with endometriosis who underwent surgery. Included patients had postoperative ultrasound investigations to detect evidence of endometriosis recurrence. The selected timeframe was 5 years. We conducted a literature review on ultrasound markers of endometriosis recurrence. RESULTS: In this analysis, 2023 patients from 9 studies were included. The recurrence rate detected was 17.26%. The postoperative treatment was different in the selected studies and they include the administration of progesterone, oral combined contraceptives, GnRh antagonists, aromatase inhibitors and intrauterine devices with prolonged release of progesterone. DISCUSSION: The recurrence rate is different in the selected studies as a result of the recurrence definition used by each author and the minimum dimension of the lesions, in case of the cystic pattern. Innovative techniques of differential diagnosis by ultrasound are proposed, one of them being the textural analysis performed by computer-aided diagnosis ­ CAD. In order to standardize the recommendations regarding imaging techniques, we propose an algorithm for following up with patients in the postoperative period. CONCLUSION: The transabdominal or endovaginal ultrasound performed regularly represents a key factor to determine the recurrence of endometriosis in the postoperative period and the imaging reassessment is recommended to be performed at a 6-month interval.


Subject(s)
Endometriosis , Female , Humans , Endometriosis/diagnostic imaging , Endometriosis/surgery , Progesterone , Ultrasonography
2.
J Clin Med ; 12(2)2023 Jan 06.
Article in English | MEDLINE | ID: mdl-36675383

ABSTRACT

A fetus identified to be at risk for chromosomal abnormalities may benefit from identification of genetic defects through amniocentesis. Although the risks associated with amniocentesis are considered to be minimal, being an invasive procedure it is not completely without complications. BACKGROUND AND OBJECTIVES: The current study aims to identify correlations between blood contamination of samples collected during amniocentesis and certain factors dependent on the instruments used (thickness of the needle used to aspirate the fluid), the location of the placenta, and uterine vascularity (more pronounced in multiparous patients). MATERIALS AND METHODS: The study included 190 patients in the second trimester of pregnancy who met one of the criteria for invasive prenatal diagnosis (age over 35 years, high risk in first trimester screening, history of pregnancies with genetic abnormalities, etc.). The amniotic fluid samples collected from these patients were analyzed in terms of blood contamination of the amniotic fluid aspirated with maternal cells Results: Of the patients in whom the procedure was performed using 21 G size needles, 16 samples (13.33% of the total) were contaminated. None of the samples collected from patients where a 20 G needle was used were contaminated. There was a statistically significant association between the lack of contamination and the use of Doppler ultrasound in multiparous patients with anterior placenta in whom a 21-gauge needle was used for amniocentesis. CONCLUSIONS: There is an increased rate of sample contamination (statistically significant) when using 21 G needle sizes and a significant difference in contamination between primiparous and multiparous patients, with contamination being more frequent in multiparous patients. The use of Doppler ultrasonography may benefit the procedure, as the contamination rate was significantly reduced when used during amniocentesis.

3.
J Perinat Med ; 50(4): 446-456, 2022 May 25.
Article in English | MEDLINE | ID: mdl-35119802

ABSTRACT

OBJECTIVES: Late first-stage or second-stage cesarean section is commonly associated with fetal head impaction, leading to maternal and neonatal complications. This situation requires safe delivery techniques, but the optimal management remains controversial. The aim of this meta-analysis was to compare maternal and neonatal outcomes associated with delivery techniques via cesarean section. METHODS: An electronic search of three databases, from inception to June 2021, was conducted. Cohort and randomised comparative studies on maternal and neonatal outcomes associated with techniques to deliver an impacted fetal head during cesarean section were included. The methodological quality of the primary studies was assessed. Review Manager 5.4 was used for statistical analyses. RESULTS: Nineteen articles, including 2,345 women were analyzed. Three fetal extraction techniques were identified. Meta-analyses showed that the "pull" technique carries lower risks as compared to the "push" technique and the "Patwardhan" technique is safer compared to the "push" or the "push and pull" technique. CONCLUSIONS: In the absence of robust evidence to support the use of a specific technique, the choice of the obstetrician should be based on best available evidence. Our study suggests that the "pull", as well as the "Patwardhan" technique represent safe options to deliver an impacted fetal head.


Subject(s)
Cesarean Section , Fetus , Cesarean Section/adverse effects , Cesarean Section/methods , Female , Head/diagnostic imaging , Humans , Infant, Newborn , Male , Pregnancy
4.
Int Urogynecol J ; 33(5): 1243-1250, 2022 05.
Article in English | MEDLINE | ID: mdl-35006311

ABSTRACT

INTRODUCTION AND HYPOTHESIS: Evidence on OAB management remains suboptimal and methodological limitations in randomized control trials (RCTs) affect their comparability. High quality meta-analyses are lacking. This study aimed to compare selection and reporting of outcomes and outcome measures across RCTs as well as evaluate methodological quality and outcome reporting quality as a first stage in the process of developing core outcome sets (COS). METHODS: RCTs were searched using Pubmed, EMBASE, Medline, Cochrane, ICTRP and Clinicaltrials.gov from inception to January 2020, in English language, on adult women. Pharmacological management, interventions, sample size, journal type and commercial funding were documented. Methodological and outcome reporting quality were evaluated using JADAD and MOMENT scores. RESULTS: Thirty-eight trials (18,316 women) were included. Sixty-nine outcomes were reported, using 62 outcome measures. The most commonly reported outcome domains were efficacy (86.8%), safety (73.7%) and QoL (60.5%). The most commonly reported outcomes in each domain were urgency urinary incontinence episodes (UUI) (52.6%), antimuscarinic side effects (76.3%) and change in validated questionnaire scores (36.8%). A statistically significant correlation was found between JADAD and MOMENT (Spearman's rho = 0.548, p < 0.05) scores. This indicates that higher methodological quality is associated with higher outcome reporting quality. CONCLUSIONS: Development of COS and core outcome measure sets will address variations and lead to higher quality evidence. We recommend the most commonly reported outcomes in each domain, as interim COS. For efficacy we recommend: UUI episodes, urgency and nocturia episodes; for safety: antimuscarinic adverse events, other adverse events and discontinuation rates; for QoL: OAB-q, PPBC and IIQ scores.


Subject(s)
Urinary Bladder, Overactive , Urinary Incontinence , Adult , Female , Humans , Muscarinic Antagonists/therapeutic use , Outcome Assessment, Health Care , Randomized Controlled Trials as Topic , Treatment Outcome , Urinary Bladder, Overactive/complications , Urinary Bladder, Overactive/drug therapy , Urinary Incontinence/complications
5.
Int J Gynaecol Obstet ; 158(1): 3-12, 2022 Jul.
Article in English | MEDLINE | ID: mdl-34534366

ABSTRACT

OBJECTIVE: Given the high variation of perceptions of women with stress urinary incontinence (SUI), qualitative meta-synthesis in this field appears warranted. We aimed to synthesize evidence on women's experiences of SUI by analyzing qualitative data. METHODS: A literature search of Medline, Embase, Scopus, PsycInfo, and CINAHL databases was performed by a CHORUS Working Group, from inception to August 2020. Qualitative studies on women's perspectives on SUI were included. Thematic analysis was used as a conceptual approach to analyze the data and develop a set of overarching themes. The quality of studies was assessed based on the Critical Appraisal Skills Program tool. RESULTS: Seven studies were included. Six themes encompassing women's perspectives on SUI emerged: experiencing SUI, awareness of SUI, treatments for SUI, sexuality, communication, and psychosocial effects. The quality appraisal of the studies showed good coherence. CONCLUSION: This study revealed six overarching themes, of which treatment had the highest prevalence. Assessment of women's perceptions of SUI in the context of a qualitative meta-synthesis may inform policy and practice around this condition, may guide and help set research priorities, and will ideally contribute to the development of a Core Outcome Set for SUI.


Subject(s)
Urinary Incontinence, Stress , Female , Humans , Outcome Assessment, Health Care , Prevalence , Qualitative Research , Quality of Life/psychology , Urinary Incontinence, Stress/therapy
6.
J Obstet Gynaecol Res ; 48(1): 275-279, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34879442

ABSTRACT

Given the rarity of recurrent pelvic organ prolapse after obliterative procedures and the paucity of data in the literature on this topic, optimal management is challenging. We describe a technique of reversal of colpocleisis in an 81-year-old woman with recurrent prolapse as the first step in a staged, reconstructive procedure. Basic principles underlying our approach include multidisciplinary team involvement, detailed preoperative planning, and a series of investigations including different imaging modalities and a meticulous stepwise surgical technique. The distortion of anatomical planes, anticipated scarring, and close proximity of pelvic organs specifically bladder and rectum are important considerations. In our case, the multidisciplinary surgical team included urogynecologists, a urologist, and a colorectal surgeon. Detailed preoperative planning was agreed following multiple patient and team consultations. Preoperative investigations included ultrasound and videourodynamics. Intraoperatively, cystoscopy and sigmoidoscopy were performed to identify anatomical landmarks and planes, rule out fistulae, and evaluate for anatomical distortions involving pelvic organs. Subsequently, reversal of the colpocleisis was undertaken and uneventful. Postoperative recovery was uncomplicated and a sacrospinous fixation, anterior vaginal repair, and perineorrhaphy were performed as a secondary restorative procedure for the correction of recurrent prolapse.


Subject(s)
Pelvic Organ Prolapse , Plastic Surgery Procedures , Aged, 80 and over , Colpotomy , Female , Gynecologic Surgical Procedures , Humans , Pelvic Organ Prolapse/surgery , Pregnancy , Recurrence , Treatment Outcome , Vagina/surgery
7.
JMIR Res Protoc ; 10(11): e28032, 2021 Nov 15.
Article in English | MEDLINE | ID: mdl-34779787

ABSTRACT

BACKGROUND: Studies evaluating cosmetic gynecological interventions have followed variable methodology and reported a diversity of outcomes. Such variations limit the comparability of studies and the value of research-based evidence. The development of core outcome sets (COS) and core outcome measures sets (COMS) would help address these issues, ensuring a minimum of outcomes important to all stakeholders, primarily women requesting or having experienced cosmetic gynecological interventions. OBJECTIVE: This protocol describes the methods used in developing a COS and COMS for cosmetic gynecological interventions. METHODS: An international steering group within CHORUS, including health care professionals, researchers, and women with experience in cosmetic gynecological interventions from 4 continents, will guide the development of COS and COMS. Potential outcome measures and outcomes will be identified through comprehensive literature reviews. These potential COS and COMS will be entered into an international, multi-perspective web-based Delphi survey where Delphi participants judge which domains will be core. A priori thresholds for consensus will get established before each Delphi round. The Delphi survey results will be evaluated quantitatively and qualitatively in subsequent stakeholder group consensus meetings in the process of establishing "core" outcomes. RESULTS: Dissemination and implementation of the resulting COS and COMS within an international context will be promoted and reviewed. CONCLUSIONS: This protocol presents the steps in developing a COS and COMS for cosmetic gynecological interventions. Embedding the COS and COMS for cosmetic gynecological interventions within future clinical trials, systematic reviews, and practice guidelines could contribute to enhancing the value of research and improving overall patient care. TRIAL REGISTRATION: Core Outcome Measures in Effectiveness Trials (COMET) 1592; https://tinyurl.com/n8faysuh. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): PRR1-10.2196/28032.

8.
Neurourol Urodyn ; 39(8): 2305-2313, 2020 11.
Article in English | MEDLINE | ID: mdl-32813897

ABSTRACT

AIMS: In overactive bladder (OAB) research, different biomarkers have been proposed as diagnostic tools and may be used to create individual patient profiles. Assessing the diagnostic performance of biomarkers would better outline their utility. Therefore, our aim was to investigate the diagnostic value of four urinary biomarkers: human brain derived neurotrophic factor (hBDNF), malondialdehyde (MDA), h nerve growth factor (hNGF) and h 8-hydroxydeoxyguanosine in women with OAB. These are neurotrophins/oxidative stress markers that have been linked to lower urinary tract symptoms. METHODS: A total of 105 women were included in the study and distributed in two groups: a group with OAB (n = 53) and a control group (n = 50). The levels of the biomarkers were determined using enzyme-linked immunosorbent assay technique and they were compared between the groups. If the Mann-Whitney test demonstrated a statistically significant difference, receiver operating curves (ROC) analysis was undertaken. RESULTS: When normalized to urinary creatinine, hBDNF, MDA, and hNGF showed significantly increased values in women with OAB as compared to controls, whereas 8-OHdG showed no significant difference. The diagnostic performance of these biomarkers was analyzed based on the area under the ROC curve (AUC). MDA had the highest AUC (0.75), followed by hNGF (0.69) and hBDNF (0.67). CONCLUSIONS: Our findings suggest that MDA, a relatively novel biomarker in OAB research, has a fair performance as a diagnostic tool for OAB. Moreover, urinary neurotrophins (NGF and BDNF) as biomarkers may have a role in the diagnostic pathways of women with OAB symptoms.


Subject(s)
Brain-Derived Neurotrophic Factor/urine , Nerve Growth Factor/urine , Urinary Bladder, Overactive/diagnosis , 8-Hydroxy-2'-Deoxyguanosine/urine , Adult , Biomarkers/urine , Enzyme-Linked Immunosorbent Assay , Female , Humans , Malondialdehyde/urine , Middle Aged , Urinalysis , Urinary Bladder, Overactive/urine
9.
BMC Pregnancy Childbirth ; 20(1): 376, 2020 Jun 26.
Article in English | MEDLINE | ID: mdl-32591018

ABSTRACT

BACKGROUND: More than 85% of women sustain different degrees of trauma during vaginal birth. Randomized controlled trials on childbirth pelvic floor trauma have reported a wide range of outcomes and used different outcome measures. This variation restricts effective data synthesis, impairing the ability of research to inform clinical practice. The development and use of a core outcome set (COS) for childbirth pelvic floor trauma aims to ensure consistent use of outcome measures and reporting of outcomes. METHODS: An international steering group, within CHORUS, an International Collaboration for Harmonising Outcomes, Research and Standards in Urogynaecology and Women's Health, including academic community members, researchers, healthcare professionals, policy makers and women with childbirth pelvic floor trauma will lead the development of this COS. Relevant outcome parameters will be identified through comprehensive literature reviews. The selected outcomes will be entered into an international, multi-perspective online Delphi survey. Subsequently and based on the results of the Delphi surveys consensus will be sought on 'core' outcomes. DISCUSSION: Dissemination and implementation of the resulting COS within an international context will be supported and promoted. Embedding the COS for childbirth pelvic floor trauma within future clinical trials, systematic reviews, and clinical practice guidelines is expected to enrich opportunities for comparison of future clinical trials and allow better synthesis of outcomes, and will enhance mother and child care. The infrastructure created by developing a COS for childbirth pelvic floor trauma could be leveraged in other settings, for example, advancing research priorities and clinical practice guideline development.


Subject(s)
Delivery, Obstetric/adverse effects , Outcome Assessment, Health Care/methods , Pelvic Floor Disorders/therapy , Research Design , Consensus , Delphi Technique , Female , Humans , Pelvic Floor/injuries , Pregnancy , Stakeholder Participation , Treatment Outcome
10.
Med Ultrason ; 22(1): 65-70, 2020 03 01.
Article in English | MEDLINE | ID: mdl-32096790

ABSTRACT

AimsThe present study aims to investigate the pain, anxiety and other factors that are associated with percutaneous computed tomography (CT)- and ultrasound (US)-guided biopsies of tumors.Material and MethodsThe study prospectively included 60 consecutive patients, of which 24 underwent CT-guided biopsies and 36 US-guided biopsies. The location of targeted tumors was within the thorax, abdomen, pelvis, and limbs. A questionnaire containing numerical rate scales (0-10) regarding procedural and post-procedural pain, anxiety, and other associated parameters was filled out by each patient 2-6 hours after the procedure. CT and ultrasound parameters were compared.  The two groups were then pooled together in order to compare pain scores per targeted organ and to analyze the parameters that were associated with pain.ResultsThere was no significant difference between the CT and US group with the exception of the positional discomfort, which was higher in the CT group (p=0.003). The average procedural pain score (2.0) was significantly higher than the post-procedural pain (1.3, p=0.006) and the phlebotomy pain (0.8, p<0.0001). There was no significant difference between the targeted organs with regards to the pain score. The factors that showed a positive correlation with the procedural pain were procedure-related anxiety (p=0.005), positional discomfort (p=0.01), and phlebotomy pain (p=0.0008). The pre interventional use of an analgesic was negatively correlated with the procedural pain (p=0.02).ConclusionsCT- and US- guided percutaneous biopsies are associated with low levels of pain that are generally well tolerated by patients irrespective of the targeted organ.


Subject(s)
Image-Guided Biopsy/adverse effects , Image-Guided Biopsy/methods , Neoplasms/pathology , Pain, Procedural/etiology , Tomography, X-Ray Computed , Ultrasonography, Interventional , Adult , Aged , Female , Humans , Male , Middle Aged , Prospective Studies
11.
Neurourol Urodyn ; 39(3): 880-889, 2020 03.
Article in English | MEDLINE | ID: mdl-32040864

ABSTRACT

AIMS: In the current climate of evidence-based health care, the aim of this meta-synthesis was to collect and systematically analyse data from primary qualitative studies on pelvic organ prolapse (POP), to identify patient-centered perspectives on the natural course of POP. Information acquired in this study may be useful for ongoing research towards the development of core outcome sets (COS) in pelvic floor disorders. METHODS: A CHORUS Working Group performed a standardized search of three different databases (Medline, Embase, Scopus), from inception to October 2019. We selected qualitative studies on women's perspectives on POP that were published in the English language. Three reviewers independently evaluated the quality of eligible papers and highlighted recurrent themes based on patient perspectives. RESULTS: Eighteen qualitative studies including a total of 497 patients were assessed in this analysis. Our study revealed five superordinate themes, recurrently encountered in qualitative studies on POP: awareness of POP (6 studies), communication (9 studies), treatments (10 studies), effects on quality of life (6 studies), and self-image (3 studies). Five out of 10 quality criteria were met by all the studies included, based on an assessment performed using the critical appraisal skills program. CONCLUSIONS: This is the first synthesis of qualitative studies that address POP-related experiences of women, highlighting five superordinate themes, of which treatment was the most commonly reported one. This synthesis' findings may guide quantitative research priorities and will hopefully contribute to the development of a COS for POP.


Subject(s)
Patient Reported Outcome Measures , Pelvic Floor Disorders/physiopathology , Pelvic Floor Disorders/psychology , Pelvic Organ Prolapse/physiopathology , Pelvic Organ Prolapse/psychology , Quality of Life , Female , Humans , Qualitative Research
12.
Rev Bras Ginecol Obstet ; 41(9): 525-530, 2019 Sep.
Article in English | MEDLINE | ID: mdl-31546275

ABSTRACT

OBJECTIVE: The etiology of embryonic demise is multifactorial, with chromosomal abnormalities being the most common (40%). The purpose of the present study is to evaluate the correlation between a serum biomarker, progesterone, and an ultrasonographic parameter, the distance between yolk sac and embryo (DYSE) in assessing the prognosis of pregnancy outcome in the 1st trimester. METHODS: The present study is a prospective case-control analysis that includes 2 groups of patients: 81 patients with first-trimester normal evolutive pregnancy and 89 patients with embryonic demise, all of the patients having between 6 and 11 weeks of amenorrhea. Endovaginal ultrasonographic exploration was performed to evaluate the distance between the lower pole of the embryo and the yolk sac. From each subject enrolled in the study, 20 ml of blood was collected for progesterone serum level measurement. RESULTS: Regarding the DYSE in the case group, lower values were observed compared with the control group, the difference being statistically significant. In the statistical analysis of serum progesterone values, statistically significant differences were observed between the 2 groups (p < 0.05). CONCLUSION: The DYSE has a high positive predictive value in identifying pregnancies with potentially reserved outcome, with the present study demonstrating that a DYSE < 3 mm causes an unfavorable evolution of the pregnancy. Low serum levels of progesterone are associated with an increased rate of nonviable embryos. The correlation between these two parameters increases the effectiveness of screening methods in prenatal monitoring and improves the diagnostic methods for the first-trimester pregnancies whose outcome potential can be reserved.


Subject(s)
Pregnancy Outcome/epidemiology , Pregnancy Trimester, First , Progesterone/blood , Ultrasonography, Prenatal , Case-Control Studies , Embryo, Mammalian/diagnostic imaging , Female , Humans , Pregnancy , Pregnancy Trimester, First/blood , Pregnancy Trimester, First/physiology , Prognosis , Yolk Sac/diagnostic imaging
13.
Medicine (Baltimore) ; 98(37): e16876, 2019 Sep.
Article in English | MEDLINE | ID: mdl-31517813

ABSTRACT

INTRODUCTION: Randomized trials evaluating interventions for stress urinary incontinence (SUI) have been using variable outcome measures, reporting a variety of outcomes. Alongside this variation across studies, outcome-reporting flaws contribute to a limited use of research to inform clinical practice. The development and use of core outcome sets (COSs) in future trials would ensure that outcomes important to different stakeholders and primarily women with SUI are reported more consistently and comprehensively. METHODS: An international steering group including healthcare professionals, researchers, and women with urinary incontinence will guide the development of this COS. Potential outcomes will be identified through comprehensive literature reviews. These outcomes will be entered into an international, multiperspective online Delphi survey. All key stakeholders, including healthcare professionals, researchers, and women with urinary incontinence, will be invited to participate. The modified Delphi method encourages stakeholder group convergence toward collective agreement, also referred as consensus, core outcomes. DISCUSSION: Dissemination and implementation of the resulting COS within an international context will be promoted and reviewed. Embedding the COS for SUI within future clinical trials, systematic reviews and clinical practice guidelines could make a significant contribution to advancing the value of research in informing clinical practice, enhancing patient care and improving outcomes. The infrastructure created by developing a COS for SUI could be leveraged in other settings, for example, selecting research priorities and clinical practice guideline development.


Subject(s)
Consensus Development Conferences as Topic , Urinary Incontinence, Stress/diagnosis , Urinary Incontinence, Stress/therapy , Delphi Technique , Female , Health Personnel , Humans , Research Design , Systematic Reviews as Topic , Treatment Outcome
14.
Medicina (Kaunas) ; 55(9)2019 Sep 03.
Article in English | MEDLINE | ID: mdl-31484328

ABSTRACT

Background and objectives: As pelvic floor disorders are often difficult to assess thoroughly based on clinical examination alone, the use of imaging as a complementary technique is helpful. This study's aim was to investigate by transperineal ultrasound (US) if there was any significant difference in the mobility of the bladder neck in women with stress urinary incontinence (SUI) without a cystocele and in those with SUI and an associated cystocele. The study also investigated whether the number of vaginal births and/or the heaviest newborn's birth weight was correlated with the bladder neck mobility. Materials and Methods: A total of 71 women suffering from SUI were included in the study and divided into two groups based on the presence of a cystocele. Their bladder neck mobility was evaluated by transperineal US, calculating the distance from the inferior margin of the symphysis pubis to the bladder neck (SPBN), and the dorsocaudal linear movement (DLM), term used to illustrate the displacement of the bladder neck by subtracting rest and Valsalva values. GraphPad Prism 8 was used for statistical analysis. Results: Within both study groups, the SPBN values were significantly higher and the DLM values were significantly lower at rest as compared to Valsalva maneuver (p < 0.05). No significant difference between the groups regarding SPBN and DLM values at rest, Valsalva, or subtraction was demonstrated. A significant positive correlation was found between the bladder neck mobility and the heaviest newborn's birth weight, regardless of the presence of a cystocele (p = 0.042). Conclusions: The presence of a cystocele had no significant impact on the bladder neck mobility measurements in patients with SUI. The heaviest newborn's birth weight positively correlated with bladder neck hypermobility, as quantified by SPBN.


Subject(s)
Cystocele/complications , Peripheral Nerves/abnormalities , Ultrasonography/methods , Urinary Bladder/abnormalities , Urinary Incontinence, Stress/physiopathology , Aged , Cystocele/epidemiology , Cystocele/physiopathology , Female , Humans , Middle Aged , Peripheral Nerves/physiopathology , Research Design , Romania/epidemiology , Ultrasonography/statistics & numerical data , Urinary Bladder/physiopathology , Urinary Incontinence, Stress/epidemiology , Urinary Incontinence, Stress/etiology
15.
Rev. bras. ginecol. obstet ; 41(9): 525-530, Sept. 2019. tab, graf
Article in English | LILACS | ID: biblio-1042339

ABSTRACT

Abstract Objective The etiology of embryonic demise is multifactorial, with chromosomal abnormalities being the most common (40%). The purpose of the present study is to evaluate the correlation between a serum biomarker, progesterone, and an ultrasonographic parameter, the distance between yolk sac and embryo (DYSE) in assessing the prognosis of pregnancy outcome in the 1st trimester. Methods The present study is a prospective case-control analysis that includes 2 groups of patients: 81 patients with first-trimester normal evolutive pregnancy and 89 patients with embryonic demise, all of the patients having between 6 and 11 weeks of amenorrhea. Endovaginal ultrasonographic exploration was performed to evaluate the distance between the lower pole of the embryo and the yolk sac. From each subject enrolled in the study, 20ml of blood was collected for progesterone serum level measurement. Results Regarding the DYSE in the case group, lower values were observed compared with the control group, the difference being statistically significant. In the statistical analysis of serum progesterone values, statistically significant differences were observed between the 2 groups (p<0.05). Conclusion The DYSE has a high positive predictive value in identifying pregnancies with potentially reserved outcome, with the present study demonstrating that a DYSE<3mm causes an unfavorable evolution of the pregnancy. Low serum levels of progesterone are associated with an increased rate of nonviable embryos. The correlation between these two parameters increases the effectiveness of screening methods in prenatal monitoring and improves the diagnostic methods for the firsttrimester pregnancies whose outcome potential can be reserved.


Subject(s)
Humans , Female , Pregnancy , Pregnancy Trimester, First/physiology , Pregnancy Trimester, First/blood , Progesterone/blood , Pregnancy Outcome/epidemiology , Ultrasonography, Prenatal , Prognosis , Yolk Sac/diagnostic imaging , Case-Control Studies , Embryo, Mammalian/diagnostic imaging
16.
Turk J Med Sci ; 47(1): 115-122, 2017 Feb 27.
Article in English | MEDLINE | ID: mdl-28263477

ABSTRACT

BACKGROUND/AIM: The aim of the study was to evaluate the serum concentration of main chemokines and interferons in patients with diagnosed endometriosis. MATERIALS AND METHODS: A total of 160 women were divided in two study groups (group 1 - endometriosis; group 2 - healthy women). Serum levels of IFN-α, IFN-γ, MCP-1, MIP-1α, MIP-1ß, RANTES, eotaxin, IL-8, MIG, IP-10, and IL-17A were measured with Human Multiplex Cytokine Panels. Results. Serum levels of IFN-γ, MCP-1, and IL-8 were significantly higher (mean 14.03, 57.24, and 534.24, respectively, compared to 0.58, 20.51, and 259.82, respectively), and serum levels of IP-10 and eotaxin were significantly lower in women with endometriosis compared to the controls (mean 1.15 and 1.01, respectively, compared to 3.90 and 3.22, respectively). Conclusions. According to our results women with endometriosis have elevated levels IFN-γ, MCP-1, and IL-8, and lower serum levels of IP-10 and eotaxin, indicating unbalanced immune activity in endometriosis.


Subject(s)
Chemokines/blood , Endometriosis/blood , Endometriosis/epidemiology , Interferons/blood , Adolescent , Adult , Case-Control Studies , Female , Humans , Young Adult
17.
Anal Cell Pathol (Amst) ; 2016: 3496538, 2016.
Article in English | MEDLINE | ID: mdl-27822448

ABSTRACT

Introduction. The identification of biological markers that indicate an increased risk for the development or recurrence of endometrial cancer (EC) in obese women might be useful for decreasing EC mortality and morbidity. Glucose-regulated protein 78 (GRP78) is a major protein of the endoplasmic reticulum expressed in all normal cells. Overexpression of GRP78 has been reported to be a tumoral biomarker. Increased detection of GRP78 is positively correlated with the tumoral stage and prognosis. This study aimed to identify a correlation between intraperitoneal fat, plasma GRP78 levels, and EC. Materials and Methods. Two groups of patients were included in the study: group I, 44 patients diagnosed with EC, and group II, 44 patients without gynecological pathology or inflammatory disorders. Visceral fat was determined by ultrasound and plasma GRP78 levels were measured. Results. Plasma GRP78 levels were significantly higher in patients with EC compared to the control group. Intraperitoneal fat was in a positive linear correlation with the plasma GRP78 level (p < 0.0001). Conclusion. The measurement of the GRP78 level associated with the determination of intraperitoneal fat can be a useful predictor for EC.


Subject(s)
Adiposity , Endometrial Neoplasms/metabolism , Heat-Shock Proteins/metabolism , Peritoneum/metabolism , Aged , Endoplasmic Reticulum Chaperone BiP , Female , Humans , Linear Models , Risk Factors
18.
J Res Med Sci ; 20(7): 668-74, 2015 Jul.
Article in English | MEDLINE | ID: mdl-26622256

ABSTRACT

BACKGROUND: Endometriosis is a frequent gynecologic disease with a severe impact on the quality of life in the affected women; its pathogenesis is yet to be fully understood, with an altered immunity as a possible key factor. The present study aimed to investigate the serum anti-inflammatory cytokine profile in the patients with endometriosis compared with the healthy controls. MATERIALS AND METHODS: One hundred and sixty women were included, divided into two study groups (Group I - endometriosis; Group 2 - healthy women). We evaluated the serum levels of interleukin-1 receptor antagonist (IL-1Ra), IL-2, IL-2R, IL-4, IL-10, IL-13, and IL-15 with the use of Human multiplex cytokine panels. Statistical analyses (normality distribution analysis, independent t-test, Mann-Whitney U-test) were performed using IBM SPSS software (version 22.0) and GraphPad Prism (version 5.00); receiver operating characteristic curve were used to demonstrate the diagnostic performance of the studied markers. RESULTS: The mean serum level of IL-1Ra, IL-4, and IL-10 were significantly higher in women with endometriosis compared to women free of disease from the control group (30.155, 138.459, and 1.489, respectively, compared to 14.109, 84.710, and 0.688, respectively; P < 0.001, P < 0.001, and P = 0.002, respectively.). No significant differences in the mean serum levels of IL-2, IL-13, and IL-15 were observed between the studied groups and IL-2R had a very low detection rate. CONCLUSION: Endometriosis is associated with elevated levels of anti-inflammatory cytokines, IL-1Ra, IL-4, and IL-10, markers that have a potential role as a prognostic factor for endometriosis.