Acta Stomatol Croat ; 56(3): 222-234, 2022 Sep.
Article in English | MEDLINE | ID: mdl-36382208

ABSTRACT

Objectives: Although titanium-based implants are considered bioinert, it has been found that they are subject to corrosion and wear. This study aimed to evaluate the cytotoxic and genotoxic potential of two implant systems in gingival epithelial cells. Material and methods: Gingival swabs were taken three times from 91 subjects. The first swab was taken before dental implant placement, the second swab 90 days after dental implant placement and the third swab 21 days following the healing abutment placement. DNA damage was analyzed using the micronucleus test. Tested dental implants with corresponding healing abutments were Ankylos and Dentium SuperLine. Results: Of all scored forms of cytogenetic damage in gingival cells of individuals after implementation of tested dental implant systems, only an increase in the number of binucleated cells (P ≤ 0.001) was significant in contrast to control values for both tested implant systems, 90 days after dental implant placement and 21 days following the healing abutment placement. Conclusion: It may be concluded that there are no titanium-based implant dependent cytogenetic damage in gingival epithelial cells. A slight increase in cytogenetic damage has been observed but it is of no biological relevance and might be associated with healing abutment induced effect.