Am J Cardiol ; 164: 103-110, 2022 02 01.
Article in English | MEDLINE | ID: mdl-34819234

ABSTRACT

The MacNew questionnaire is a disease-specific quality of life measure that has been used in patients with myocardial infarction and heart failure. We aimed to investigate the impact of transcatheter aortic valve implantation (TAVI) on health-related quality of life (HRQoL) using MacNew Questionnaire and identify predictors associated with a change in its score. This was a prospective multi-center study performed across 5 National Health Service hospitals in the United Kingdom performing TAVI between 2016 and 2018. HRQoL was assessed using MacNew Questionnaire, Euro Quality of Life-5D-5L, and Short Form 36 questionnaires collected at baseline, 3-, 6- and 12 months after the procedure. Out of 225 recruited patients, 19 did not have TAVI and 4 withdrew their consent, and hence 202 patients were included. HRQoL was assessed in 181, 161, and 147 patients at 3, 6, and 12 months, respectively. Using MacNew, there was a significant improvement in all domains of HRQoL as early as 3 months after TAVI which was sustained up to 12 months with improved discrimination of change in HRQoL compared with other scales. Poor mobility at baseline and history of myocardial infarction were independent predictors of reduced improvement in HRQoL at 3 months. HRQoL increased in all subgroups of patients including frail ones. In conclusion, the MacNew assessment tool performed well in a representative TAVI cohort and could be used as an alternative disease-specific method for assessing HRQoL change after TAVI.


Subject(s)
Aortic Valve Stenosis/surgery , Quality of Life , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve Stenosis/epidemiology , Aortic Valve Stenosis/physiopathology , Comorbidity , Female , Frailty/epidemiology , Humans , Male , Mobility Limitation , Myocardial Infarction/epidemiology , Patient Reported Outcome Measures , Prospective Studies , Surveys and Questionnaires , Treatment Outcome , United Kingdom
2.
Catheter Cardiovasc Interv ; 93(4): 751-757, 2019 03 01.
Article in English | MEDLINE | ID: mdl-30394657

ABSTRACT

OBJECTIVES: The UK & Ireland Implanters' registry is a multicenter registry which reports on real-world experience with novel transcatheter heart valves. BACKGROUND: The 34 mm Evolut R transcatheter aortic valve is a self-expanding and fully recapturable transcatheter aortic valve, designed to treat patients with a large aortic annulus. METHODS: Between January 2017 and April 2018, clinical, procedural and 30-day outcome data were prospectively collected from all patients receiving the 34 mm Evolut R valve across 17 participating centers in the United Kingdom and Ireland. The primary efficacy outcome was the Valve Academic Research Consortium-2(VARC-2)-defined endpoint of device success. The primary safety outcome was the VARC-2-defined composite endpoint of early safety at 30 days. RESULTS: A total of 217 patients underwent attempted implant. Mean age was 79.5 ± 8.8 years and Society of Thoracic Surgeons Predicted Risk of Mortality Score 5.2% ± 3.4%. Iliofemoral access was used in 91.2% of patients. Device success was 79.7%. Mean gradient was 7.0 ± 4.6 mmHg and effective orifice area 2.0 ± 0.6 cm2 . Paravalvular regurgitation was more than mild in 7.2%. A new permanent pacemaker was implanted in 15.7%. Early safety was demonstrated in 91.2%. At 30 days, all-cause mortality was 3.2%, stroke 3.7%, and major vascular complication 2.3%. CONCLUSIONS: Real-world experience of the 34 mm Evolut R transcatheter aortic valve demonstrated acceptable procedural success, safety, valve function, and incidence of new permanent pacemaker implantation.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Female , Hemodynamics , Humans , Ireland , Male , Postoperative Complications/mortality , Postoperative Complications/therapy , Prosthesis Design , Registries , Risk Assessment , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome , United Kingdom
3.
Catheter Cardiovasc Interv ; 82(4): E592-4, 2013 Oct 01.
Article in English | MEDLINE | ID: mdl-23172721

ABSTRACT

We report the case of a very late erosion of an Amplatzer septal occluder (ASO) device more than 8 years after implant, presenting without signs of cardiac tamponade. To date, this case represents the longest period between ASO device implantation and clinical presentation following erosion. The overall rate of device erosion remains low, and the majority reported so far has occurred early, but clinicians should remain alert to the possibility of very late erosion in patients with ASO devices.


Subject(s)
Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Chest Pain/etiology , Heart Septal Defects, Atrial/therapy , Pericardial Effusion/etiology , Prosthesis Failure , Septal Occluder Device , Adult , Cardiac Surgical Procedures , Chest Pain/diagnosis , Chest Pain/surgery , Device Removal , Female , Heart Septal Defects, Atrial/diagnosis , Heart Septal Defects, Atrial/surgery , Humans , Pericardial Effusion/diagnosis , Pericardial Effusion/surgery , Pericardium/transplantation , Prosthesis Design , Time Factors , Tomography, X-Ray Computed , Treatment Outcome
5.
Heart Surg Forum ; 15(1): E9-11, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22360911

ABSTRACT

An 80-year-old woman with a 20-mm Medtronic Hall (tilting-disc) aortic prosthesis presented with episodes of chest pain associated with circulatory collapse and subsequent rapid spontaneous recovery. A computed tomography angiogram demonstrated no evidence of aortic dissection, pulmonary embolus, or coronary artery disease. A transthoracic echocardiogram demonstrated a well-functioning prosthetic aortic valve. After another inpatient episode, auscultation demonstrated an intermittent absence of the prosthetic second heart sound. A transesophageal echocardiography examination revealed that the aortic valve was intermittently sticking in the open position. During the emergency replacement, the existing valve was noted to have pannus and overlying thrombus, which are rare in this type of valve but can lead to dramatic circulatory collapse when present. This case demonstrates how a diagnosis of intermittent valve dysfunction can prove elusive. It is important, as part of the assessment of mechanical valves, to perform regular, careful auscultation and echocardiographic examination, with emphasis on recording in Doppler or M-mode through the valve at slow sweep speeds for a prolonged period in order to maximize the chance of diagnosing episodic valve dysfunction.


Subject(s)
Aortic Valve/pathology , Heart Valve Diseases/complications , Heart Valve Prosthesis/adverse effects , Shock/etiology , Aged, 80 and over , Aortic Valve/surgery , Cardiac Catheterization , Chest Pain , Echocardiography , Equipment Failure , Female , Heart Valve Diseases/pathology , Humans , Shock/pathology , Time Factors
6.
Circ Cardiovasc Interv ; 3(2): 157-65, 2010 Apr.
Article in English | MEDLINE | ID: mdl-20332383

ABSTRACT

BACKGROUND: Neointima formation and atherosclerosis compromise long-term graft patency in aortocoronary and peripheral vein bypass grafts. We investigated the short- and long-term effects of periadventitial application of a sustained-release formulation of rapamycin on experimental pig vein grafts with similar dimensions and kinetics to human saphenous vein bypass grafts. METHODS AND RESULTS: Periadventitial application of rapamycin-eluting polyvinyl alcohol microspheres (60 microg . cm(-2)) to porcine saphenous vein-to-carotid artery interposition grafts inhibited vein graft positive and vascular smooth muscle cell proliferation in 1-week grafts. It also decreased neointima formation and wall thickening in 4-week vein grafts compared with controls. The inhibition of vein graft thickening was not sustained; however, a catch-up phenomenon was observed, and there was no therapeutic benefit evident in 12-week grafts. Increasing the dose of rapamycin to 120 microg . cm(-2) was associated with significant local toxicity manifest by high rates of graft rupture (25%), inhibition of adventitial neoangiogenesis, and a paradoxical acceleration of vein graft disease as evidenced by increased vascular smooth muscle cell proliferation. CONCLUSIONS: Local toxicity and poor long-term efficacy limits the clinical applicability of locally applied, sustained rapamycin release in vein graft disease.


Subject(s)
Graft Occlusion, Vascular/drug therapy , Myocytes, Smooth Muscle/drug effects , Saphenous Vein/drug effects , Sirolimus/administration & dosage , Tunica Intima/drug effects , Animals , Carotid Arteries/surgery , Cell Proliferation/drug effects , Coronary Artery Bypass , Graft Occlusion, Vascular/etiology , Graft Occlusion, Vascular/pathology , Humans , Microspheres , Models, Animal , Myocytes, Smooth Muscle/pathology , Neovascularization, Pathologic , Saphenous Vein/pathology , Saphenous Vein/transplantation , Sirolimus/adverse effects , Swine , Transplantation, Isogeneic , Tunica Intima/growth & development , Tunica Intima/pathology , Tunica Intima/transplantation