1.
Eur Heart J Imaging Methods Pract ; 2(1): qyae016, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38645798

ABSTRACT

Aims: Pressure-volume (PV) loops have utility in the evaluation of cardiac pathophysiology but require invasive measurements. Recently, a time-varying elastance model to derive PV loops non-invasively was proposed, using left ventricular (LV) volume by cardiovascular magnetic resonance (CMR) and brachial cuff pressure as inputs. Validation was performed using CMR and pressure measurements acquired on the same day, but not simultaneously, and without varying pre-loads. This study validates the non-invasive elastance model used to estimate PV loops at varying pre-loads, compared with simultaneous measurements of invasive pressure and volume from real-time CMR, acquired concurrent to an inferior vena cava (IVC) occlusion. Methods and results: We performed dynamic PV loop experiments under CMR guidance in 15 pigs (n = 7 naïve, n = 8 with ischaemic cardiomyopathy). Pre-load was altered by IVC occlusion, while simultaneously acquiring invasive LV pressures and volumes from real-time CMR. Pairing pressure and volume signals yielded invasive PV loops, and model-based PV loops were derived using real-time LV volumes. Haemodynamic parameters derived from invasive and model-based PV loops were compared. Across 15 pigs, 297 PV loops were recorded. Intra-class correlation coefficient (ICC) agreement was excellent between model-based and invasive parameters: stroke work (bias = 0.007 ± 0.03 J, ICC = 0.98), potential energy (bias = 0.02 ± 0.03 J, ICC = 0.99), ventricular energy efficiency (bias = -0.7 ± 2.7%, ICC = 0.98), contractility (bias = 0.04 ± 0.1 mmHg/mL, ICC = 0.97), and ventriculoarterial coupling (bias = 0.07 ± 0.15, ICC = 0.99). All haemodynamic parameters differed between naïve and cardiomyopathy animals (P < 0.05). The invasive vs. model-based PV loop dice similarity coefficient was 0.88 ± 0.04. Conclusion: An elastance model-based estimation of PV loops and associated haemodynamic parameters provided accurate measurements at transient loading conditions compared with invasive PV loops.

2.
Magn Reson Med ; 92(1): 173-185, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38501940

ABSTRACT

PURPOSE: To develop an iterative concomitant field and motion corrected (iCoMoCo) reconstruction for isotropic high-resolution UTE pulmonary imaging at 0.55 T. METHODS: A free-breathing golden-angle stack-of-spirals UTE sequence was used to acquire data for 8 min with prototype and commercial 0.55 T MRI scanners. The data was binned into 12 respiratory phases based on superior-inferior navigator readouts. The previously published iterative motion corrected (iMoCo) reconstruction was extended to include concomitant field correction directly in the cost function. The reconstruction was implemented within the Gadgetron framework for inline reconstruction. Data were retrospectively reconstructed to simulate scan times of 2, 4, 6, and 8 min. Image quality was assessed using apparent SNR and image sharpness. The technique was evaluated in healthy volunteers and patients with known lung pathology including coronavirus disease 2019 infection, chronic granulomatous disease, lymphangioleiomyomatosis, and lung nodules. RESULTS: The technique provided diagnostic-quality images, and image quality was maintained with a slight loss in SNR for simulated scan times down to 4 min. Parenchymal apparent SNR was 4.33 ± 0.57, 5.96 ± 0.65, 7.36 ± 0.64, and 7.87 ± 0.65 using iCoMoCo with scan times of 2, 4, 6, and 8 min, respectively. Image sharpness at the diaphragm was comparable between iCoMoCo and reference images. Concomitant field corrections visibly improved the sharpness of anatomical structures away from the isocenter. Inline image reconstruction and artifact correction were achieved in <5 min. CONCLUSION: The proposed iCoMoCo pulmonary imaging technique can generate diagnostic quality images with 1.75 mm isotropic resolution in less than 5 min using a 6-min acquisition, on a 0.55 T scanner.


Subject(s)
Lung , Magnetic Resonance Imaging , Humans , Lung/diagnostic imaging , Magnetic Resonance Imaging/methods , Image Processing, Computer-Assisted/methods , Motion , Signal-To-Noise Ratio , Algorithms , Artifacts , COVID-19/diagnostic imaging , Male , Respiration , Retrospective Studies , Female , SARS-CoV-2 , Image Interpretation, Computer-Assisted/methods , Adult , Lung Diseases/diagnostic imaging , Phantoms, Imaging , Lung Neoplasms/diagnostic imaging
3.
Magn Reson Med ; 2024 Mar 12.
Article in English | MEDLINE | ID: mdl-38469944

ABSTRACT

PURPOSE: To develop an inline automatic quality control to achieve consistent diagnostic image quality with subject-specific scan time, and to demonstrate this method for 2D phase-contrast flow MRI to reach a predetermined SNR. METHODS: We designed a closed-loop feedback framework between image reconstruction and data acquisition to intermittently check SNR (every 20 s) and automatically stop the acquisition when a target SNR is achieved. A free-breathing 2D pseudo-golden-angle spiral phase-contrast sequence was modified to listen for image-quality messages from the reconstructions. Ten healthy volunteers and 1 patient were imaged at 0.55 T. Target SNR was selected based on retrospective analysis of cardiac output error, and performance of the automatic SNR-driven "stop" was assessed inline. RESULTS: SNR calculation and automated segmentation was feasible within 20 s with inline deployment. The SNR-driven acquisition time was 2 min 39 s ± 67 s (aorta) and 3 min ± 80 s (main pulmonary artery) with a min/max acquisition time of 1 min 43 s/4 min 52 s (aorta) and 1 min 43 s/5 min 50 s (main pulmonary artery) across 6 healthy volunteers, while ensuring a diagnostic measurement with relative absolute error in quantitative flow measurement lower than 2.1% (aorta) and 6.3% (main pulmonary artery). CONCLUSION: The inline quality control enables subject-specific optimized scan times while ensuring consistent diagnostic image quality. The distribution of automated stopping times across the population revealed the value of a subject-specific scan time.

4.
Magn Reson Med ; 92(1): 346-360, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38394163

ABSTRACT

PURPOSE: To introduce alternating current-controlled, conductive ink-printed marker that could be implemented with both custom and commercial interventional devices for device tracking under MRI using gradient echo, balanced SSFP, and turbo spin-echo sequences. METHODS: Tracking markers were designed as solenoid coils and printed on heat shrink tubes using conductive ink. These markers were then placed on three MR-compatible test samples that are typically challenging to visualize during MRI scans. MRI visibility of markers was tested by applying alternating and direct current to the markers, and the effects of applied current parameters (amplitude, frequency) on marker artifacts were tested for three sequences (gradient echo, turbo spin echo, and balanced SSFP) in a gel phantom, using 0.55T and 1.5T MRI scanners. Furthermore, an MR-compatible current supply circuit was designed, and the performance of the current-controlled markers was tested in one postmortem animal experiment using the current supply circuit. RESULTS: Direction and parameters of the applied current were determined to provide the highest conspicuity for all three sequences. Marker artifact size was controlled by adjusting the current amplitude, successfully. Visibility of a custom-designed, 20-gauge nitinol needle was increased in both in vitro and postmortem animal experiments using the current supply circuit. CONCLUSION: Current-controlled conductive ink-printed markers can be placed on custom or commercial MR-compatible interventional tools and can provide an easy and effective solution to device tracking under MRI for three sequences by adjusting the applied current parameters with respect to pulse sequence parameters using the current supply circuit.


Subject(s)
Equipment Design , Magnetic Resonance Imaging , Phantoms, Imaging , Animals , Magnetic Resonance Imaging/instrumentation , Magnetic Resonance Imaging/methods , Artifacts , Magnetic Resonance Imaging, Interventional/instrumentation
5.
J Magn Reson Imaging ; 59(2): 412-430, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37530545

ABSTRACT

Cardiac MR imaging is well established for assessment of cardiovascular structure and function, myocardial scar, quantitative flow, parametric mapping, and myocardial perfusion. Despite the clear evidence supporting the use of cardiac MRI for a wide range of indications, it is underutilized clinically. Recent developments in low-field MRI technology, including modern data acquisition and image reconstruction methods, are enabling high-quality low-field imaging that may improve the cost-benefit ratio for cardiac MRI. Studies to-date confirm that low-field MRI offers high measurement concordance and consistent interpretation with clinical imaging for several routine sequences. Moreover, low-field MRI may enable specific new clinical opportunities for cardiac imaging such as imaging near metal implants, MRI-guided interventions, combined cardiopulmonary assessment, and imaging of patients with severe obesity. In this review, we discuss the recent progress in low-field cardiac MRI with a focus on technical developments and early clinical validation studies. EVIDENCE LEVEL: 5 TECHNICAL EFFICACY: Stage 1.


Subject(s)
Heart , Magnetic Resonance Imaging , Humans , Magnetic Resonance Imaging/methods , Heart/diagnostic imaging , Myocardium , Radiography , Image Processing, Computer-Assisted/methods
6.
J Cardiovasc Magn Reson ; 25(1): 48, 2023 08 14.
Article in English | MEDLINE | ID: mdl-37574552

ABSTRACT

Transcatheter cardiovascular interventions increasingly rely on advanced imaging. X-ray fluoroscopy provides excellent visualization of catheters and devices, but poor visualization of anatomy. In contrast, magnetic resonance imaging (MRI) provides excellent visualization of anatomy and can generate real-time imaging with frame rates similar to X-ray fluoroscopy. Realization of MRI as a primary imaging modality for cardiovascular interventions has been slow, largely because existing guidewires, catheters and other devices create imaging artifacts and can heat dangerously. Nonetheless, numerous clinical centers have started interventional cardiovascular magnetic resonance (iCMR) programs for invasive hemodynamic studies or electrophysiology procedures to leverage the clear advantages of MRI tissue characterization, to quantify cardiac chamber function and flow, and to avoid ionizing radiation exposure. Clinical implementation of more complex cardiovascular interventions has been challenging because catheters and other tools require re-engineering for safety and conspicuity in the iCMR environment. However, recent innovations in scanner and interventional device technology, in particular availability of high performance low-field MRI scanners could be the inflection point, enabling a new generation of iCMR procedures. In this review we review these technical considerations, summarize contemporary clinical iCMR experience, and consider potential future applications.


Subject(s)
Cardiac Catheterization , Magnetic Resonance Imaging, Interventional , Humans , Predictive Value of Tests , Magnetic Resonance Imaging , Magnetic Resonance Spectroscopy
7.
Magn Reson Med ; 90(4): 1396-1413, 2023 10.
Article in English | MEDLINE | ID: mdl-37288601

ABSTRACT

PURPOSE: Exercise-induced dyspnea caused by lung water is an early heart failure symptom. Dynamic lung water quantification during exercise is therefore of interest to detect early stage disease. This study developed a time-resolved 3D MRI method to quantify transient lung water dynamics during rest and exercise stress. METHODS: The method was evaluated in 15 healthy subjects and 2 patients with heart failure imaged in transitions between rest and exercise, and in a porcine model of dynamic extravascular lung water accumulation through mitral regurgitation (n = 5). Time-resolved images were acquired at 0.55T using a continuous 3D stack-of-spirals proton density weighted sequence with 3.5 mm isotropic resolution, and derived using a motion corrected sliding-window reconstruction with 90-s temporal resolution in 20-s increments. A supine MRI-compatible pedal ergometer was used for exercise. Global and regional lung water density (LWD) and percent change in LWD (ΔLWD) were automatically quantified. RESULTS: A ΔLWD increase of 3.3 ± 1.5% was achieved in the animals. Healthy subjects developed a ΔLWD of 7.8 ± 5.0% during moderate exercise, peaked at 16 ± 6.8% during vigorous exercise, and remained unchanged over 10 min at rest (-1.4 ± 3.5%, p = 0.18). Regional LWD were higher posteriorly compared the anterior lungs (rest: 33 ± 3.7% vs 20 ± 3.1%, p < 0.0001; peak exercise: 36 ± 5.5% vs 25 ± 4.6%, p < 0.0001). Accumulation rates were slower in patients than healthy subjects (2.0 ± 0.1%/min vs 2.6 ± 0.9%/min, respectively), whereas LWD were similar at rest (28 ± 10% and 28 ± 2.9%) and peak exercise (ΔLWD 17 ± 10% vs 16 ± 6.8%). CONCLUSION: Lung water dynamics can be quantified during exercise using continuous 3D MRI and a sliding-window image reconstruction.


Subject(s)
Heart Failure , Magnetic Resonance Imaging , Animals , Swine , Lung/diagnostic imaging , Exercise Test
8.
MAGMA ; 36(3): 465-475, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37306784

ABSTRACT

OBJECTIVE: Diagnostic-quality neuroimaging methods are vital for widespread clinical adoption of low field MRI. Spiral imaging is an efficient acquisition method that can mitigate the reduced signal-to-noise ratio at lower field strengths. As concomitant field artifacts are worse at lower field, we propose a generalizable quadratic gradient-field nulling as an echo-to-echo compensation and apply it to spiral TSE at 0.55 T. MATERIALS AND METHODS: A spiral in-out TSE acquisition was developed with a compensation for concomitant field variation between spiral interleaves, by adding bipolar gradients around each readout to minimize phase differences at each refocusing pulse. Simulations were performed to characterize concomitant field compensation approaches. We demonstrate our proposed compensation method in phantoms and (n = 8) healthy volunteers at 0.55 T. RESULTS: Spiral read-outs with integrated spoiling demonstrated strong concomitant field artifacts but were mitigated using the echo-to-echo compensation. Simulations predicted a decrease of concomitant field phase RMSE between echoes of 42% using the proposed compensation. Spiral TSE improved SNR by 17.2 ± 2.3% compared to reference Cartesian acquisition. DISCUSSION: We demonstrated a generalizable approach to mitigate concomitant field artifacts for spiral TSE acquisitions via the addition of quadratic-nulling gradients, which can potentially improve neuroimaging at low-field through increased acquisition efficiency.


Subject(s)
Brain , Image Enhancement , Humans , Image Enhancement/methods , Brain/diagnostic imaging , Magnetic Resonance Imaging/methods , Neuroimaging/methods , Signal-To-Noise Ratio , Artifacts
9.
Magn Reson Med ; 90(2): 552-568, 2023 08.
Article in English | MEDLINE | ID: mdl-37036033

ABSTRACT

PURPOSE: To develop 2D turbo spin-echo (TSE) imaging using annular spiral rings (abbreviated "SPRING-RIO TSE") with compensation of concomitant gradient fields and B0 inhomogeneity at both 0.55T and 1.5T for fast T2 -weighted imaging. METHODS: Strategies of gradient waveform modifications were implemented in SPRING-RIO TSE for compensation of self-squared concomitant gradient terms at the TE and across echo spacings, along with reconstruction-based corrections to simultaneously compensate for the residual concomitant gradient and B0 field induced phase accruals along the readout. The signal pathway disturbance caused by time-varying and spatially dependent concomitant fields was simulated, and echo-to-echo phase variations before and after sequence-based compensation were compared. Images from SPRING-RIO TSE with no compensation, with compensation, and Cartesian TSE were also compared via phantom and in vivo acquisitions. RESULTS: Simulation showed how concomitant fields affected the signal evolution with no compensation, and both simulation and phantom studies demonstrated the performance of the proposed sequence modifications, as well as the readout off-resonance corrections. Volunteer data showed that after full correction, the SPRING-RIO TSE sequence achieved high image quality with improved SNR efficiency (15%-20% increase), and reduced RF SAR (˜50% reduction), compared to the standard Cartesian TSE, presenting potential benefits, especially in regaining SNR at low-field (0.55T). CONCLUSION: Implementation of SPRING-RIO TSE with concomitant field compensation was tested at 0.55T and 1.5T. The compensation principles can be extended to correct for other trajectory types that are time-varying along the echo train and temporally asymmetric in TSE-based imaging.


Subject(s)
Brain , Magnetic Resonance Imaging , Humans , Magnetic Resonance Imaging/methods , Brain/diagnostic imaging , Image Enhancement/methods , Phantoms, Imaging , Magnetic Phenomena
10.
Invest Radiol ; 58(9): 663-672, 2023 09 01.
Article in English | MEDLINE | ID: mdl-36822664

ABSTRACT

BACKGROUND: Oxygen-enhanced magnetic resonance imaging (OE-MRI) can be used to assess regional lung function without ionizing radiation. Inhaled oxygen acts as a T1-shortening contrast agent to increase signal in T1-weighted (T1w) images. However, increase in proton density from pulmonary hyperoxic vasodilation may also contribute to the measured signal enhancement. Our aim was to quantify the relative contributions of the T1-shortening and vasodilatory effects of oxygen to signal enhancement in OE-MRI in both swine and healthy volunteers. METHODS: We imaged 14 anesthetized female swine (47 ± 8 kg) using a prototype 0.55 T high-performance MRI system while experimentally manipulating oxygenation and blood volume independently through oxygen titration, partial occlusion of the vena cava for volume reduction, and infusion of colloid fluid (6% hydroxyethyl starch) for volume increase. Ten healthy volunteers were imaged before, during, and after hyperoxia. Two proton density-weighted (PDw) and 2 T1w ultrashort echo time images were acquired per experimental state. The median PDw and T1w percent signal enhancement (PSE), compared with baseline room air, was calculated after image registration and correction for lung volume changes. Differences in median PSE were compared using Wilcoxon signed rank test. RESULTS: The PSE in PDw images after 100% oxygen was similar in swine (1.66% ± 1.41%, P = 0.01) and in healthy volunteers (1.99% ± 1.79%, P = 0.02), indicating that oxygen-induced pulmonary vasodilation causes ~2% lung proton density increase. The PSE in T1w images after 100% oxygen was also similar (swine, 9.20% ± 1.68%, P < 0.001; healthy volunteers, 10.10% ± 3.05%, P < 0.001). The PSE in T1w enhancement was oxygen dose-dependent in anesthetized swine, and we measured a dose-dependent PDw image signal increase from infused fluids. CONCLUSIONS: The contribution of oxygen-induced vasodilation to T1w OE-MRI signal was measurable using PDw imaging and was found to be ~2% in both anesthetized swine and in healthy volunteers. This finding may have implications for patients with regional or global hypoxia or vascular dysfunction undergoing OE-MRI and suggest that PDw imaging may be useful to account for oxygen-induced vasodilation in OE-MRI.


Subject(s)
Lung Diseases , Oxygen , Female , Animals , Swine , Protons , Vasodilation , Imaging, Three-Dimensional/methods , Lung/diagnostic imaging , Magnetic Resonance Imaging/methods
11.
J Cardiovasc Magn Reson ; 25(1): 1, 2023 01 16.
Article in English | MEDLINE | ID: mdl-36642713

ABSTRACT

BACKGROUND: Left ventricular (LV) contractility and compliance are derived from pressure-volume (PV) loops during dynamic preload reduction, but reliable simultaneous measurements of pressure and volume are challenging with current technologies. We have developed a method to quantify contractility and compliance from PV loops during a dynamic preload reduction using simultaneous measurements of volume from real-time cardiovascular magnetic resonance (CMR) and invasive LV pressures with CMR-specific signal conditioning. METHODS: Dynamic PV loops were derived in 16 swine (n = 7 naïve, n = 6 with aortic banding to increase afterload, n = 3 with ischemic cardiomyopathy) while occluding the inferior vena cava (IVC). Occlusion was performed simultaneously with the acquisition of dynamic LV volume from long-axis real-time CMR at 0.55 T, and recordings of invasive LV and aortic pressures, electrocardiogram, and CMR gradient waveforms. PV loops were derived by synchronizing pressure and volume measurements. Linear regression of end-systolic- and end-diastolic- pressure-volume relationships enabled calculation of contractility. PV loops measurements in the CMR environment were compared to conductance PV loop catheter measurements in 5 animals. Long-axis 2D LV volumes were validated with short-axis-stack images. RESULTS: Simultaneous PV acquisition during IVC-occlusion was feasible. The cardiomyopathy model measured lower contractility (0.2 ± 0.1 mmHg/ml vs 0.6 ± 0.2 mmHg/ml) and increased compliance (12.0 ± 2.1 ml/mmHg vs 4.9 ± 1.1 ml/mmHg) compared to naïve animals. The pressure gradient across the aortic band was not clinically significant (10 ± 6 mmHg). Correspondingly, no differences were found between the naïve and banded pigs. Long-axis and short-axis LV volumes agreed well (difference 8.2 ± 14.5 ml at end-diastole, -2.8 ± 6.5 ml at end-systole). Agreement in contractility and compliance derived from conductance PV loop catheters and in the CMR environment was modest (intraclass correlation coefficient 0.56 and 0.44, respectively). CONCLUSIONS: Dynamic PV loops during a real-time CMR-guided preload reduction can be used to derive quantitative metrics of contractility and compliance, and provided more reliable volumetric measurements than conductance PV loop catheters.


Subject(s)
Cardiac Catheterization , Myocardial Ischemia , Swine , Animals , Predictive Value of Tests , Magnetic Resonance Imaging , Magnetic Resonance Spectroscopy , Ventricular Function, Left , Stroke Volume
12.
Magn Reson Med ; 89(2): 845-858, 2023 02.
Article in English | MEDLINE | ID: mdl-36198118

ABSTRACT

PURPOSE: We describe a clinical grade, "active", monopole antenna-based metallic guidewire that has a continuous shaft-to-tip image profile, a pre-shaped tip-curve, standard 0.89 mm (0.035″) outer diameter, and a detachable connector for catheter exchange during cardiovascular catheterization at 0.55T. METHODS: Electromagnetic simulations were performed to characterize the magnetic field around the antenna whip for continuous tip visibility. The active guidewire was manufactured using medical grade materials in an ISO Class 7 cleanroom. RF-induced heating of the active guidewire prototype was tested in one gel phantom per ASTM 2182-19a, alone and in tandem with clinical metal-braided catheters. Real-time MRI visibility was tested in one gel phantom and in-vivo in two swine. Mechanical performance was compared with commercial equivalents. RESULTS: The active guidewire provided continuous "profile" shaft and tip visibility in-vitro and in-vivo, analogous to guidewire shaft-and-tip profiles under X-ray. The MRI signal signature matched simulation results. Maximum unscaled RF-induced temperature rise was 5.2°C and 6.5°C (3.47 W/kg local background specific absorption rate), alone and in tandem with a steel-braided catheter, respectively. Mechanical characteristics matched commercial comparator guidewires. CONCLUSION: The active guidewire was clearly visible via real-time MRI at 0.55T and exhibits a favorable geometric sensitivity profile depicting the guidewire continuously from shaft-to-tip including a unique curved-tip signature. RF-induced heating is clinically acceptable. This design allows safe device navigation through luminal structures and heart chambers. The detachable connector allows delivery and exchange of cardiovascular catheters while maintaining guidewire position. This enhanced guidewire design affords the expected performance of X-ray guidewires during human MRI catheterization.


Subject(s)
Magnetic Resonance Imaging, Interventional , Swine , Humans , Animals , Cardiac Catheterization/methods , Equipment Design , Cardiac Catheters , Phantoms, Imaging
14.
J Cardiovasc Magn Reson ; 24(1): 35, 2022 06 06.
Article in English | MEDLINE | ID: mdl-35668497

ABSTRACT

BACKGROUND: Quantitative assessment of dynamic lung water accumulation is of interest to unmask latent heart failure. We develop and validate a free-breathing 3D ultrashort echo time (UTE) sequence with automated inline image processing to image changes in lung water density (LWD) using high-performance 0.55 T cardiovascular magnetic resonance (CMR). METHODS: Quantitative lung water CMR was performed on 15 healthy subjects using free-breathing 3D stack-of-spirals proton density weighted UTE at 0.55 T. Inline image reconstruction and automated image processing was performed using the Gadgetron framework. A gravity-induced redistribution of LWD was provoked by sequentially acquiring images in the supine, prone, and again supine position. Quantitative validation was performed in a phantom array of vials containing mixtures of water and deuterium oxide. RESULTS: The phantom experiment validated the capability of the sequence in quantifying water density (bias ± SD 4.3 ± 4.8%, intraclass correlation coefficient, ICC = 0.97). The average global LWD was comparable between imaging positions (supine 24.7 ± 3.4%, prone 22.7 ± 3.1%, second supine 25.3 ± 3.6%), with small differences between imaging phases (first supine vs prone 2.0%, p < 0.001; first supine vs second supine - 0.6%, p = 0.001; prone vs second supine - 2.7%, p < 0.001). In vivo test-retest repeatability in LWD was excellent (- 0.17 ± 0.91%, ICC = 0.97). A regional LWD redistribution was observed in all subjects when repositioning, with a predominant posterior LWD accumulation when supine, and anterior accumulation when prone (difference in anterior-posterior LWD: supine - 11.6 ± 2.7%, prone 5.5 ± 2.7%, second supine - 11.4 ± 2.9%). Global LWD maps were calculated inline within 23.2 ± 0.3 s following the image reconstruction using the automated pipeline. CONCLUSIONS: Redistribution of LWD due to gravitational forces can be depicted and quantified using a validated free-breathing 3D proton density weighted UTE sequence and inline automated image processing pipeline on a high-performance 0.55 T CMR system.


Subject(s)
Lung , Protons , Humans , Imaging, Three-Dimensional , Magnetic Resonance Imaging/methods , Magnetic Resonance Spectroscopy , Predictive Value of Tests
15.
Magn Reson Med ; 88(2): 691-710, 2022 08.
Article in English | MEDLINE | ID: mdl-35445768

ABSTRACT

PURPOSE: To develop and evaluate an improved strategy for compensating concomitant field effects in non-Cartesian MRI at the time of image reconstruction. THEORY: We present a higher-order reconstruction method, denoted as MaxGIRF, for non-Cartesian imaging that simultaneously corrects off-resonance, concomitant fields, and trajectory errors without requiring specialized hardware. Gradient impulse response functions are used to predict actual gradient waveforms, which are in turn used to estimate the spatiotemporally varying concomitant fields based on analytic expressions. The result, in combination with a reference field map, is an encoding matrix that incorporates a correction for all three effects. METHODS: The MaxGIRF reconstruction is applied to noiseless phantom simulations, spiral gradient-echo imaging of an International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology phantom, and axial and sagittal multislice spiral spin-echo imaging of a healthy volunteer at 0.55 T. The MaxGIRF reconstruction was compared against previously established concomitant field-compensation and image-correction methods. Reconstructed images are evaluated qualitatively and quantitatively using normalized RMS error. Finally, a low-rank approximation of MaxGIRF is used to reduce computational burden. The accuracy of the low-rank approximation is studied as a function of minimum rank. RESULTS: The MaxGIRF reconstruction successfully mitigated blurring artifacts both in phantoms and in vivo and was effective in regions where concomitant fields counteract static off-resonance, superior to the comparator method. A minimum rank of 8 and 30 for axial and sagittal scans, respectively, gave less than 2% error compared with the full-rank reconstruction. CONCLUSIONS: The MaxGIRF reconstruction simultaneously corrects off-resonance, trajectory errors, and concomitant field effects. The impact of this method is greatest when imaging with longer readouts and/or at lower field strength.


Subject(s)
Algorithms , Artifacts , Humans , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Phantoms, Imaging
16.
Circ Cardiovasc Interv ; 15(6): e011686, 2022 06.
Article in English | MEDLINE | ID: mdl-35378990

ABSTRACT

BACKGROUND: Left ventricular outflow tract obstruction complicates hypertrophic cardiomyopathy and transcatheter mitral valve replacement. Septal reduction therapies including surgical myectomy and alcohol septal ablation are limited by surgical morbidity or coronary anatomy and high pacemaker rates, respectively. We developed a novel transcatheter procedure, mimicking surgical myotomy, called Septal Scoring Along the Midline Endocardium (SESAME). METHODS: SESAME was performed in 5 naive pigs and 5 pigs with percutaneous aortic banding-induced left ventricular hypertrophy. Fluoroscopy and intracardiac echocardiography guided the procedures. Coronary guiding catheters and guidewires were used to mechanically enter the basal interventricular septum. Imparting a tip bend to the guidewire enabled intramyocardial navigation with multiple df. The guidewire trajectory determined the geometry of SESAME myotomy. The myocardium was lacerated using transcatheter electrosurgery. Cardiac function and tissue characteristics were assessed by cardiac magnetic resonance at baseline, postprocedure, and at 7- or 30-day follow-up. RESULTS: SESAME myotomy along the intended trajectory was achieved in all animals. The myocardium splayed after laceration, increasing left ventricular outflow tract area (753 to 854 mm2, P=0.008). Two naive pigs developed ventricular septal defects due to excessively deep lacerations in thin baseline septa. No hypertrophy model pig, with increased septal thickness and left ventricular mass compared with naive pigs, developed ventricular septal defects. One animal developed left axis deviation on ECG but no higher conduction block was seen in any animal. Coronary artery branches were intact on angiography with no infarction on cardiac magnetic resonance late gadolinium imaging. Cardiac magnetic resonance chamber volumes, function, flow, and global strain were preserved. No myocardial edema was evident on cardiac magnetic resonance T1 mapping. CONCLUSIONS: This preclinical study demonstrated feasibility of SESAME, a novel transcatheter myotomy to relieve left ventricular outflow tract obstruction. This percutaneous procedure using available devices, with a safe surgical precedent, is readily translatable into patients.


Subject(s)
Cardiomyopathy, Hypertrophic , Heart Defects, Congenital , Heart Septal Defects, Ventricular , Myotomy , Ventricular Outflow Obstruction , Animals , Cardiomyopathy, Hypertrophic/complications , Cardiomyopathy, Hypertrophic/diagnostic imaging , Cardiomyopathy, Hypertrophic/surgery , Endocardium/pathology , Heart Septal Defects, Ventricular/complications , Humans , Mitral Valve/surgery , Myotomy/adverse effects , Swine , Treatment Outcome , Ventricular Outflow Obstruction/diagnostic imaging , Ventricular Outflow Obstruction/etiology , Ventricular Outflow Obstruction/surgery
17.
Invest Radiol ; 57(3): 178-186, 2022 03 01.
Article in English | MEDLINE | ID: mdl-34652290

ABSTRACT

OBJECTIVES: Contemporary lower-field magnetic resonance imaging (MRI) may offer advantages for lung imaging by virtue of the improved field homogeneity. The aim of this study was to evaluate the utility of lower-field MRI for combined morphologic imaging and regional lung function assessment. We evaluate low-field MRI in patients with lymphangioleiomyomatosis (LAM), a rare lung disease associated with parenchymal cysts and respiratory failure. MATERIALS AND METHODS: We performed lung imaging on a prototype low-field (0.55 T) MRI system in 65 patients with LAM. T2-weighted imaging was used for assessment of lung morphology and to derive cyst scores, the percent of lung parenchyma occupied by cysts. Regional lung function was assessed using oxygen-enhanced MRI with breath-held ultrashort echo time imaging and inhaled 100% oxygen as a T1-shortening MR contrast agent. Measurements of percent signal enhancement from oxygen inhalation and percentage of lung with low oxygen enhancement, indicating functional deficits, were correlated with global pulmonary function test measurements taken within 2 days. RESULTS: We were able to image cystic abnormalities using T2-weighted MRI in this patient population and calculate cyst score with strong correlation to computed tomography measurements (R = 0.86, P < 0.0001). Oxygen-enhancement maps demonstrated regional deficits in lung function of patients with LAM. Heterogeneity of oxygen enhancement between cysts was observed within individual patients. The percent low-enhancement regions showed modest, but significant, correlation with FEV1 (R = -0.37, P = 0.007), FEV1/FVC (R = -0.33, P = 0.02), and cyst score (R = 0.40, P = 0.02). The measured arterial blood ΔT1 between normoxia and hyperoxia, used as a surrogate for dissolved oxygen in blood, correlated with DLCO (R = -0.28, P = 0.03). CONCLUSIONS: Using high-performance 0.55 T MRI, we were able to perform simultaneous imaging of pulmonary structure and regional function in patients with LAM.


Subject(s)
Cysts , Lymphangioleiomyomatosis , Cysts/complications , Humans , Lung/diagnostic imaging , Lymphangioleiomyomatosis/complications , Lymphangioleiomyomatosis/diagnostic imaging , Magnetic Resonance Imaging/methods , Oxygen/chemistry
18.
Magn Reson Med ; 87(4): 1784-1798, 2022 04.
Article in English | MEDLINE | ID: mdl-34783391

ABSTRACT

PURPOSE: To develop an isotropic high-resolution stack-of-spirals UTE sequence for pulmonary imaging at 0.55 Tesla by leveraging a combination of robust respiratory-binning, trajectory correction, and concomitant-field corrections. METHODS: A stack-of-spirals golden-angle UTE sequence was used to continuously acquire data for 15.5 minutes. The data was binned to a stable respiratory phase based on superoinferior readout self-navigator signals. Corrections for trajectory errors and concomitant field artifacts, along with image reconstruction with conjugate gradient SENSE, were performed inline within the Gadgetron framework. Finally, data were retrospectively reconstructed to simulate scan times of 5, 8.5, and 12 minutes. Image quality was assessed using signal-to-noise, image sharpness, and qualitative reader scores. The technique was evaluated in healthy volunteers, patients with coronavirus disease 2019 infection, and patients with lung nodules. RESULTS: The technique provided diagnostic quality images with parenchymal lung SNR of 3.18 ± 0.0.60, 4.57 ± 0.87, 5.45 ± 1.02, and 5.89 ± 1.28 for scan times of 5, 8.5, 12, and 15.5 minutes, respectively. The respiratory binning technique resulted in significantly sharper images (p < 0.001) as measured with relative maximum derivative at the diaphragm. Concomitant field corrections visibly improved sharpness of anatomical structures away from iso-center. The image quality was maintained with a slight loss in SNR for simulated scan times down to 8.5 minutes. Inline image reconstruction and artifact correction were achieved in <5 minutes. CONCLUSION: The proposed pulmonary imaging technique combined efficient stack-of-spirals imaging with robust respiratory binning, concomitant field correction, and trajectory correction to generate diagnostic quality images with 1.75 mm isotropic resolution in 8.5 minutes on a high-performance 0.55 Tesla system.


Subject(s)
COVID-19 , Imaging, Three-Dimensional , Artifacts , Humans , Lung/diagnostic imaging , Magnetic Resonance Imaging , Retrospective Studies , SARS-CoV-2
19.
NMR Biomed ; 34(8): e4562, 2021 08.
Article in English | MEDLINE | ID: mdl-34080253

ABSTRACT

The purpose of this study was to evaluate oxygen-enhanced pulmonary imaging at 0.55 T with 3D stack-of-spirals ultrashort-TE (UTE) acquisition. Oxygen-enhanced pulmonary MRI offers the measurement of regional lung ventilation and perfusion using inhaled oxygen as a contrast agent. Low-field MRI systems equipped with contemporary hardware can provide high-quality structural lung imaging by virtue of the prolonged T2 *. Fortuitously, the T1 relaxivity of oxygen increases at lower field strengths, which is expected to improve the sensitivity of oxygen-enhanced lung MRI. We implemented a breath-held T1 -weighted 3D stack-of-spirals UTE acquisition with a 7 ms spiral-out readout. Measurement repeatability was assessed using five repetitions of oxygen-enhanced lung imaging in healthy volunteers (n = 7). The signal intensity at both normoxia and hyperoxia was strongly dependent on lung tissue density modulated by breath-hold volume during the five repetitions. A voxel-wise correction for lung tissue density improved the repeatability of percent signal enhancement maps (coefficient of variation = 34 ± 16%). Percent signal enhancement maps were compared in 15 healthy volunteers and 10 patients with lymphangioleiomyomatosis (LAM), a rare cystic disease known to reduce pulmonary function. We measured a mean percent signal enhancement of 9.0 ± 3.5% at 0.55 T in healthy volunteers, and reduced signal enhancement in patients with LAM (5.4 ± 4.8%, p = 0.02). The heterogeneity, estimated by the percent of lung volume exhibiting low enhancement, was significantly increased in patients with LAM compared with healthy volunteers (11.1 ± 6.0% versus 30.5 ± 13.1%, p = 0.01), illustrating the capability to measure regional functional deficits.


Subject(s)
Lung/diagnostic imaging , Magnetic Resonance Imaging , Oxygen/chemistry , Adult , Female , Healthy Volunteers , Humans , Imaging, Three-Dimensional , Lung/pathology , Lymphangioleiomyomatosis , Male , Middle Aged , Reproducibility of Results , Signal Processing, Computer-Assisted
20.
J Cardiovasc Magn Reson ; 23(1): 50, 2021 05 06.
Article in English | MEDLINE | ID: mdl-33952312

ABSTRACT

PURPOSE: Low-field (0.55 T) high-performance cardiovascular magnetic resonance (CMR) is an attractive platform for CMR-guided intervention as device heating is reduced around 7.5-fold compared to 1.5 T. This work determines the feasibility of visualizing cardiac radiofrequency (RF) ablation lesions at low field CMR and explores a novel alternative method for targeted tissue destruction: acetic acid chemoablation. METHODS: N = 10 swine underwent X-ray fluoroscopy-guided RF ablation (6-7 lesions) and acetic acid chemoablation (2-3 lesions) of the left ventricle. Animals were imaged at 0.55 T with native contrast 3D-navigator gated T1-weighted T1w) CMR for lesion visualization, gated single-shot imaging to determine potential for real-time visualization of lesion formation, and T1 mapping to measure change in T1 in response to ablation. Seven animals were euthanized on ablation day and hearts imaged ex vivo. The remaining animals were imaged again in vivo at 21 days post ablation to observe lesion evolution. RESULTS: Chemoablation lesions could be visualized and displayed much higher contrast than necrotic RF ablation lesions with T1w imaging. On the day of ablation, in vivo myocardial T1 dropped by 19 ± 7% in RF ablation lesion cores, and by 40 ± 7% in chemoablation lesion cores (p < 4e-5). In high resolution ex vivo imaging, with reduced partial volume effects, lesion core T1 dropped by 18 ± 3% and 42 ± 6% for RF and chemoablation, respectively. Mean, median, and peak lesion signal-to-noise ratio (SNR) were all at least 75% higher with chemoablation. Lesion core to myocardium contrast-to-noise (CNR) was 3.8 × higher for chemoablation. Correlation between in vivo and ex vivo CMR and histology indicated that the periphery of RF ablation lesions do not exhibit changes in T1 while the entire extent of chemoablation exhibits T1 changes. Correlation of T1w enhancing lesion volumes indicated in vivo estimates of lesion volume are accurate for chemoablation but underestimate extent of necrosis for RF ablation. CONCLUSION: The visualization of coagulation necrosis from cardiac ablation is feasible using low-field high-performance CMR. Chemoablation produced a more pronounced change in lesion T1 than RF ablation, increasing SNR and CNR and thereby making it easier to visualize in both 3D navigator-gated and real-time CMR and more suitable for low-field imaging.


Subject(s)
Catheter Ablation , Radiofrequency Ablation , Acetic Acid , Animals , Myocardium , Predictive Value of Tests , Swine