Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters










Publication year range
1.
J Biomed Opt ; 26(10)2021 10.
Article in English | MEDLINE | ID: mdl-34672145

ABSTRACT

SIGNIFICANCE: After three decades, more than 75,000 publications, tens of companies being involved in its commercialization, and a global market perspective of about USD 1.5 billion in 2023, optical coherence tomography (OCT) has become one of the fastest successfully translated imaging techniques with substantial clinical and economic impacts and acceptance. AIM: Our perspective focuses on disruptive forward-looking innovations and key technologies to further boost OCT performance and therefore enable significantly enhanced medical diagnosis. APPROACH: A comprehensive review of state-of-the-art accomplishments in OCT has been performed. RESULTS: The most disruptive future OCT innovations include imaging resolution and speed (single-beam raster scanning versus parallelization) improvement, new implementations for dual modality or even multimodality systems, and using endogenous or exogenous contrast in these hybrid OCT systems targeting molecular and metabolic imaging. Aside from OCT angiography, no other functional or contrast enhancing OCT extension has accomplished comparable clinical and commercial impacts. Some more recently developed extensions, e.g., optical coherence elastography, dynamic contrast OCT, optoretinography, and artificial intelligence enhanced OCT are also considered with high potential for the future. In addition, OCT miniaturization for portable, compact, handheld, and/or cost-effective capsule-based OCT applications, home-OCT, and self-OCT systems based on micro-optic assemblies or photonic integrated circuits will revolutionize new applications and availability in the near future. Finally, clinical translation of OCT including medical device regulatory challenges will continue to be absolutely essential. CONCLUSIONS: With its exquisite non-invasive, micrometer resolution depth sectioning capability, OCT has especially revolutionized ophthalmic diagnosis and hence is the fastest adopted imaging technology in the history of ophthalmology. Nonetheless, OCT has not been completely exploited and has substantial growth potential-in academics as well as in industry. This applies not only to the ophthalmic application field, but also especially to the original motivation of OCT to enable optical biopsy, i.e., the in situ imaging of tissue microstructure with a resolution approaching that of histology but without the need for tissue excision.


Subject(s)
Ophthalmology , Tomography, Optical Coherence , Artificial Intelligence
2.
Sci Rep ; 11(1): 21052, 2021 10 26.
Article in English | MEDLINE | ID: mdl-34702941

ABSTRACT

Photonic integrated circuits (PIC) provide promising functionalities to significantly reduce the size and costs of optical coherence tomography (OCT) systems. This paper presents an imaging platform operating at a center wavelength of 830 nm for ophthalmic application using PIC-based swept source OCT. An on-chip Mach-Zehnder interferometer (MZI) configuration, which comprises an input power splitter, polarization beam splitters in the sample and the reference arm, and a 50/50 coupler for signal interference represents the core element of the system with a footprint of only [Formula: see text]. The system achieves 94 dB imaging sensitivity with 750 [Formula: see text]W on the sample, 50 kHz imaging speed and 5.5 [Formula: see text]m axial resolution (in soft tissue). With this setup, in vivo human retinal imaging of healthy subjects was performed producing B-scans, three-dimensional renderings as well as OCT angiography. These promising results are significant prerequisites for further integration of optical and electronic building blocks on a single swept source-OCT PIC.


Subject(s)
Angiography/instrumentation , Equipment Design , Retina/diagnostic imaging , Tomography, Optical Coherence/instrumentation , Angiography/methods , Humans , Tomography, Optical Coherence/methods
3.
J Biomed Opt ; 26(6)2021 06.
Article in English | MEDLINE | ID: mdl-34142472

ABSTRACT

SIGNIFICANCE: Speckle noise limits the diagnostic capabilities of optical coherence tomography (OCT) images, causing both a reduction in contrast and a less accurate assessment of the microstructural morphology of the tissue. AIM: We present a speckle-noise reduction method for OCT volumes that exploits the advantages of adaptive-noise wavelet thresholding with a wavelet compounding method applied to several frames acquired from consecutive positions. The method takes advantage of the wavelet representation of the speckle statistics, calculated properly from a homogeneous sample or a region of the noisy volume. APPROACH: The proposed method was first compared quantitatively with different state-of-the-art approaches by being applied to three different clinical dermatological OCT volumes with three different OCT settings. The method was also applied to a public retinal spectral-domain OCT dataset to demonstrate its applicability to different imaging modalities. RESULTS: The results based on four different metrics demonstrate that the proposed method achieved the best performance among the tested techniques in suppressing noise and preserving structural information. CONCLUSIONS: The proposed OCT denoising technique has the potential to adapt to different image OCT settings and noise environments and to improve image quality prior to clinical diagnosis based on visual assessment.


Subject(s)
Algorithms , Tomography, Optical Coherence , Retina/diagnostic imaging , Signal-To-Noise Ratio
4.
Light Sci Appl ; 10(1): 6, 2021 Jan 05.
Article in English | MEDLINE | ID: mdl-33402664

ABSTRACT

In this work, we present a significant step toward in vivo ophthalmic optical coherence tomography and angiography on a photonic integrated chip. The diffraction gratings used in spectral-domain optical coherence tomography can be replaced by photonic integrated circuits comprising an arrayed waveguide grating. Two arrayed waveguide grating designs with 256 channels were tested, which enabled the first chip-based optical coherence tomography and angiography in vivo three-dimensional human retinal measurements. Design 1 supports a bandwidth of 22 nm, with which a sensitivity of up to 91 dB (830 µW) and an axial resolution of 10.7 µm was measured. Design 2 supports a bandwidth of 48 nm, with which a sensitivity of 90 dB (480 µW) and an axial resolution of 6.5 µm was measured. The silicon nitride-based integrated optical waveguides were fabricated with a fully CMOS-compatible process, which allows their monolithic co-integration on top of an optoelectronic silicon chip. As a benchmark for chip-based optical coherence tomography, tomograms generated by a commercially available clinical spectral-domain optical coherence tomography system were compared to those acquired with on-chip gratings. The similarities in the tomograms demonstrate the significant clinical potential for further integration of optical coherence tomography on a chip system.

5.
Opt Express ; 28(22): 32468-32482, 2020 Oct 26.
Article in English | MEDLINE | ID: mdl-33114932

ABSTRACT

In this paper, we present a novel concept for a multi-channel swept source optical coherence tomography (OCT) system based on photonic integrated circuits (PICs). At the core of this concept is a low-loss polarization dependent path routing approach allowing for lower excess loss compared to previously shown PIC-based OCT systems, facilitating a parallelization of measurement units. As a proof of concept for the low-loss path routing, a silicon nitride PIC-based single-channel swept source OCT system operating at 840 nm was implemented and used to acquire in-vivo tomograms of a human retina. The fabrication of the PIC was done via CMOS-compatible plasma-enhanced chemical vapor deposition to allow future monolithic co-integration with photodiodes and read-out electronics. A performance analysis using the results of the implemented photonic building blocks shows a potential tenfold increase of the acquisition speed for a multi-channel system compared to an ideal lossless single-channel system with the same signal-to-noise ratio.

6.
Opt Lett ; 43(18): 4345, 2018 Sep 15.
Article in English | MEDLINE | ID: mdl-30211860

ABSTRACT

This publisher's note corrects an error in the funding section in Opt. Lett.42, 4319 (2017)OPLEDP0146-959210.1364/OL.42.004319.

7.
Sci Rep ; 8(1): 13216, 2018 Aug 30.
Article in English | MEDLINE | ID: mdl-30158593

ABSTRACT

A correction to this article has been published and is linked from the HTML and PDF versions of this paper. The error has not been fixed in the paper.

8.
Sci Rep ; 7(1): 17975, 2017 12 21.
Article in English | MEDLINE | ID: mdl-29269886

ABSTRACT

The cutaneous vasculature is involved in many diseases. Current clinical examination techniques, however, cannot resolve the human vasculature with all plexus in a non-invasive manner. By combining an optical coherence tomography system with angiography extension and an all optical photoacoustic tomography system, we can resolve in 3D the blood vessels in human skin for all plexus non-invasively. With a customized imaging unit that permits access to various parts of patients' bodies, we applied our multimodality imaging system to investigate several different types of skin conditions. Quantitative vascular analysis is given for each of the dermatological conditions to show the potential diagnostic value of our system in non-invasive examination of diseases and physiological processes. Improved performance of our system over its previous generation is also demonstrated with an updated characterization.


Subject(s)
Photoacoustic Techniques/methods , Skin/diagnostic imaging , Tomography, Optical Coherence/methods , Humans , Imaging, Three-Dimensional/instrumentation , Imaging, Three-Dimensional/methods , Photoacoustic Techniques/instrumentation , Skin/anatomy & histology , Skin/blood supply , Tomography, Optical Coherence/instrumentation
9.
Opt Lett ; 42(21): 4319-4322, 2017 Nov 01.
Article in English | MEDLINE | ID: mdl-29088153

ABSTRACT

This Letter presents a novel dual modality reflection mode optical coherence and photoacoustic microscopy (OC-PAM) system. The optical coherence microscopy modality features a broadband source to accomplish 5 µm axial resolution. The photoacoustic microscopy modality uses a rigid akinetic Fabry-Perot etalon encapsulated in an optically transparent medium, which forms a 2 mm×11 mm translucent imaging window, permitting reflection mode dual modality imaging. After characterization, the OC-PAM system was applied to image zebrafish larvae in vivo, demonstrating its capability in biomedical imaging with complementary optical scattering and absorption contrasts by revealing morphology in the fish larvae.


Subject(s)
Microscopy/methods , Photoacoustic Techniques/methods , Animals , Fishes , Larva , Optics and Photonics , Spectrum Analysis
10.
J Biomed Opt ; 21(9): 96011, 2016 09 01.
Article in English | MEDLINE | ID: mdl-27653999

ABSTRACT

Studies have proven the relationship between cutaneous vasculature abnormalities and dermatological disorders, but to image vasculature noninvasively

SELECTION OF CITATIONS
SEARCH DETAIL
...