Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
JID Innov ; 4(3): 100280, 2024 May.
Article in English | MEDLINE | ID: mdl-38756236

ABSTRACT

Outdoor workers have increased risk of developing keratinocyte cancer due to accumulated skin damage resulting from chronic and excessive exposure to UVR. This study aims to identify potential noninvasive biomarkers to assess chronic UVR exposure. We analyzed stratum corneum biomarkers collected from 2 skin locations and 2 occupational groups with contrasting solar UVR exposure: the forehead and retroauricular skin among outdoor workers and indoor workers. Using a linear mixed model adjusting for age and skin phototype, we compared biomarkers between both skin sites in indoor and outdoor workers. We measured markers of the immune response and skin barrier, including cytokines, GFs, 15-hydroxyeicosatetraenoic acid, cis- and trans-urocanic acid, and corneocyte topography, indicated by circular nano objects. Differences between the 2 skin sites were found for cis-urocanic acid, total urocanic acid, IL-1α, IL-1RA, IL-1RA/IL-1α, IL-18, 15-hydroxyeicosatetraenoic acid, CCL4, and circular nano objects. The levels of cis-urocanic acid and CCL4 also differed between indoor and outdoor workers. These findings underscore changes in both immune response and skin barrier induced by UVR. They indicate the potential utility of stratum corneum biomarkers in detecting both chronic UVR exposure in occupational setting and aiding in the development of preventive measures.

2.
HardwareX ; 12: e00341, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35936941

ABSTRACT

High-speed atomic force microscopes (HS-AFMs) with high temporal resolution enable dynamic phenomena to be visualized at nanoscale resolution. However, HS-AFMs are more complex and costlier than conventional AFMs, and particulars of an open-source HS-AFM controller have not been published before. These high entry barriers hinder the popularization of HS-AFMs in both academic and industrial applications. In addition, HS-AFMs generally have a small imaging area that limits the fields of implementation. This study presents an open-source controller that enables a low-cost simplified AFM to achieve a maximum tip-sample velocity of 5,093 µm/s (9.3 s/frame, 512 × 512 pixels), which is nearly 100 times higher than that of the original controller. Moreover, the proposed controller doubles the imaging area to 46.3 × 46.3 µm2 compared to that of the original system. The low-cost HS-AFM can successfully assess the severity of atopic dermatitis (AD) by measuring the nanotexture of human skin corneocytes in constant height DC mode. The open-source controller-based HS-AFM system costs less than $4,000, which provides resource-limited research institutes with affordable access to high-throughput nanoscale imaging to further expand the HS-AFM research community.

SELECTION OF CITATIONS
SEARCH DETAIL
...