Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 39
Filter
1.
Diagnostics (Basel) ; 14(7)2024 Apr 04.
Article in English | MEDLINE | ID: mdl-38611680

ABSTRACT

INTRODUCTION: Point-of-care ultrasound has become a universal practice, employed by physicians across various disciplines, contributing to diagnostic processes and decision-making. AIM: To assess the association of reduced (<50%) left-ventricular ejection fraction (LVEF) based on prospective point-of-care ultrasound operated by medical students using an artificial intelligence (AI) tool and 1-year primary composite outcome, including mortality and readmission for cardiovascular-related causes. METHODS: Eight trained medical students used a hand-held ultrasound device (HUD) equipped with an AI-based tool for automatic evaluation of the LVEF of non-selected patients hospitalized in a cardiology department from March 2019 through March 2020. RESULTS: The study included 82 patients (72 males aged 58.5 ± 16.8 years), of whom 34 (41.5%) were diagnosed with AI-based reduced LVEF. The rates of the composite outcome were higher among patients with reduced systolic function compared to those with preserved LVEF (41.2% vs. 16.7%, p = 0.014). Adjusting for pertinent variables, reduced LVEF independently predicted the composite outcome (HR 2.717, 95% CI 1.083-6.817, p = 0.033). As compared to those with LVEF ≥ 50%, patients with reduced LVEF had a longer length of stay and higher rates of the secondary composite outcome, including in-hospital death, advanced ventilatory support, shock, and acute decompensated heart failure. CONCLUSION: AI-based assessment of reduced systolic function in the hands of medical students, independently predicted 1-year mortality and cardiovascular-related readmission and was associated with unfavorable in-hospital outcomes. AI utilization by novice users may be an important tool for risk stratification for hospitalized patients.

2.
Article in English | MEDLINE | ID: mdl-38661603

ABSTRACT

BACKGROUND: Management of acute myocarditis (AM) patients experiencing ventricular arrhythmia (VA) during acute illness is controversial, especially regarding early implantable cardioverter-defibrillator (ICD) implantation. OBJECTIVES: The purpose of this study was to evaluate the prevalence of and find predictors for long-term sustained VA recurrence and overall mortality among AM patients with VA. METHODS: This was a multicenter retrospective analysis of AM patients (verified by cardiac magnetic resonance imaging or myocardial biopsy) with documented VA during the acute illness ("initial VA"). Patients with history of myocardial infarction, heart failure, or VA were excluded. The study endpoint was a composite of sustained VA and overall mortality during follow-up. RESULTS: The study included 69 AM patients with initial VA: sustained monomorphic ventricular tachycardia (MMVT) (n = 25), sustained polymorphic ventricular tachycardia (VT)/ventricular fibrillation (n = 13), and nonsustained VT (n = 31). Age was 44 ± 13 years, and 23 of 69 (33.3%) were women. During median follow-up of 5.5 years, 27 of 69 (39%) patients reached the composite endpoint including sustained VA (n = 24) and death (n = 11). Initial MMVT, predischarge left ventricular dysfunction (left ventricular ejection fraction <50%), and anteroseptal delayed enhancement on cardiac magnetic resonance imaging were significantly associated with the composite endpoint. On multivariable analysis, initial MMVT (HR: 5.17; 95% CI: 1.81-14.6; P = 0.001) and predischarge LV dysfunction (HR: 4.57; 95% CI: 1.83-11.5; P = 0.005) were independently associated with the composite endpoint. Using these 2 predictors, we could delineate subgroups with low (∼4%), medium (∼42%), and high (∼82%) 10-year incidence of composite endpoint. CONCLUSIONS: AM patients presenting with VA have high incidence of sustained VA recurrence and mortality posthospitalization. Initial MMVT and predischarge LV dysfunction are independently associated with VA recurrence and mortality. Implantable cardioverter-defibrillator implantation may be considered in such high-risk patients.

3.
J Clin Med ; 13(8)2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38673559

ABSTRACT

Background: Primary ventricular fibrillation (VF) and sustained ventricular tachycardia (VT) are potentially lethal complications in patients suffering from acute myocardial infarction (MI). In contrast with the profound data regarding the incidence and prognostic value of ventricular arrhythmias in ST elevation myocardial infarction (STEMI) patients, data regarding contemporary non-ST elevation myocardial infarction (NSTEMI) patients with ventricular arrhythmias is scarce. The aim of the current study was to investigate the incidence of VF/VT complicating NSTEMI among patients admitted to an intensive coronary care unit (ICCU). Methods: Prospective, single-center study of patients diagnosed with NSTEMI admitted to ICCU between June 2019 and December 2022. Data including demographics, presenting symptoms, comorbid conditions, and physical examination, as well as laboratory and imaging data, were analyzed. Patients were continuously monitored for arrhythmias during their admission. The study endpoint was the development of VF/sustained VT during admission. Results: A total of 732 patients were admitted to ICCU with a diagnosis of NSTEMI. Of them, six (0.8%) patients developed VF/VT during their admission. Nevertheless, three were excluded after they were misdiagnosed with NSTEMI instead of posterior ST elevation myocardial infarction (STEMI). Hence, only three (0.4%) NSTEMI patients had VF/VT during admission. None of the patients died during 1-year follow-up. Conclusions: VF/VT in NSTEMI patients treated according to contemporary guidelines including early invasive strategy is rare, suggesting these patients may not need routine monitoring and ICCU setup.

4.
Article in English | MEDLINE | ID: mdl-38499825

ABSTRACT

BACKGROUND: Cardioneuroablation has been emerging as a potential treatment alternative in appropriately selected patients with cardioinhibitory vasovagal syncope (VVS) and functional AV block (AVB). However the majority of available evidence has been derived from retrospective cohort studies performed by experienced operators. METHODS: The Cardioneuroablation for the Management of Patients with Recurrent Vasovagal Syncope and Symptomatic Bradyarrhythmias (CNA-FWRD) Registry is a multicenter prospective registry with cross-over design evaluating acute and long-term outcomes of VVS and AVB patients treated by conservative therapy and CNA. RESULTS: The study is a prospective observational registry with cross-over design for analysis of outcomes between a control group (i.e., behavioral and medical therapy only) and intervention group (Cardioneuroablation). Primary and secondary outcomes will only be assessed after enrollment in the registry. The follow-up period will be 3 years after enrollment. CONCLUSIONS: There remains a lack of prospective multicentered data for long-term outcomes comparing conservative therapy to radiofrequency CNA procedures particularly for key outcomes including recurrence of syncope, AV block, durable impact of disruption of the autonomic nervous system, and long-term complications after CNA. The CNA-FWRD registry has the potential to help fill this information gap.

5.
Am J Cardiol ; 211: 17-28, 2024 Jan 15.
Article in English | MEDLINE | ID: mdl-37879381

ABSTRACT

The current guidelines advocate prophylactic implantable cardioverter-defibrillator (ICD) for all patients with symptomatic heart failure (HF) with low left ventricular ejection fraction. Because many patients will never use their device, a score delineating subgroups with differential ICD benefit is crucial. We aimed to evaluate the MADIT-II-based Risk Stratification Score (MRSS) feasibility to delineate the ICD survival benefit in a nationwide registry of patients with HF with prophylactic ICDs. Accordingly, all Israeli patients with HF with prophylactic ICD/cardiac resynchronization therapy defibrillators were categorized into MRSS-based risk subgroups. The study end points included overall mortality, sustained ventricular arrhythmia (VA), and a competing risk of VA (potential preventable arrhythmic death, where ICD could benefit survival) versus nonarrhythmic death. Potential ICD survival benefit was estimated by the area between these cumulative incidence curves. In 2,177 patients with HF implanted prophylactic device, 189 patients (8.7%) had VA and 316 (14.5%) died during a median follow-up of 2.9 years. The MRSS risk subgroups were significantly associated with overall mortality (p <0.001) and weakly with VA (p = 0.3). The competing risk analysis of VA versus nonarrhythmic death revealed a significantly shorter duration (p <0.001) and smaller magnitude of ICD survival benefit with increased risk subgroups, yielding an estimated 76, 60, 38, and 0 life days gained from prophylactic ICD implant during a 5-year follow-up for the MRSS low-, intermediate-, high-, and very high-risk subgroups, respectively (p for trend <0.05). In conclusion, MRSS use in a nationwide registry of patients with ischemic and nonischemic cardiomyopathy, revealed subgroups with differing ICD survival benefit, suggesting it could help evaluate prophylactic ICD survival benefit.


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Humans , Stroke Volume , Ventricular Function, Left , Risk Factors , Arrhythmias, Cardiac/epidemiology , Arrhythmias, Cardiac/therapy , Heart Failure/epidemiology , Heart Failure/therapy , Risk Assessment , Registries , Primary Prevention , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/prevention & control
6.
J Clin Med ; 12(6)2023 Mar 22.
Article in English | MEDLINE | ID: mdl-36983442

ABSTRACT

BACKGROUND: Prior studies evaluating post-atrial fibrillation (AF) ablation pulmonary vein (PV) ostial gaps via magnetic resonance imaging (MRI) have shown circumferential PV fibrosis in a minority of patients, and their correlation with AF recurrence was weak. These studies were mostly based on radio-frequency AF ablations. AIM: We aimed to assess cryoballoon ablation-induced PV fibrosis via MRI and its correlation with AF recurrence. METHODS AND RESULTS: This was a prospective study of consecutive patients with symptomatic AF who underwent pre- and post-ablation MRI to assess baseline and ablation-induced fibrosis, respectively. Post-ablation PV gaps were assessed by new semi-quantitative visual analysis assisted by computerized ADAS analysis. AF recurrence monitored via multiple ECGs and event monitoring at 6 and 12 months post ablation. Nineteen patients with 80 PVs were included, age 56 ± 11, with paroxysmal and persistent AF in 17/19 and 2/19 patients, respectively. Baseline MRI showed minimal LA fibrosis. All patients underwent successful cryoballoon PV electrical isolation. Post-ablation MRI revealed circumferential PV fibrosis among 63/80 (78.8%) PVs and partial fibrosis with major gaps among 17/80 (21.2%) PVs. AF recurred within one year in 5/9 (55.5%) patients with partial PV fibrosis, while no AF recurred among the 10 patients in whom all PVs had circumferential fibrosis (p < 0.01). Similarly, there were significantly more PVs without circumferential fibrosis (due to major gaps) among patients with AF recurrence as compared with patients without AF recurrence (42.9% vs. 13.5%; p < 0.01). CONCLUSION: Cryoballoon AF ablation results in circumferential PV fibrosis in the majority of PVs, as assessed by a new clinically relevant MRI-LGE analysis. Significant correlation was found between major PV gaps on post-ablation MRI and AF recurrence, suggesting that MRI might have the ability to predict AF recurrence.

8.
Europace ; 25(3): 956-960, 2023 03 30.
Article in English | MEDLINE | ID: mdl-36636968

ABSTRACT

AIMS: Intraoperative defibrillation testing (DT) during implant or replacement of implantable cardioverter-defibrillators (ICDs) has been a matter of debate for many years. This debate was put to rest by the Simple and Nordic ICD trials, and the practice of testing during new implantations has essentially been almost abandoned. Old registries demonstrated an increased incidence of significant findings in DT during replacements. The aim of the present study was to evaluate frequency of significant findings and safety of DT in subjects undergoing device replacement. METHODS AND RESULTS: A prospective observational multi-centre study included consecutive patients undergoing ICD generator replacement. The primary outcome was a failure to terminate induced ventricular fibrillation (VF) with a single shock 10 J below the maximal capacity of the device. Secondary outcomes included complications of DT. Patients were followed-up at 1- and 6-months post-procedure. A total of 92 patients were eligible, and consented to the study, of which 84 underwent DT during battery replacement. The median age was 68 years and 79.8% were males. Induction of VF was successful in 84 patients as was a successful conversion on the first attempt in all. There were no procedure-related complications. During follow up one patient had two appropriate ICD shock events. In four patients, ICD programming was changed. None suffered inappropriate shock. There was no evidence of lead malfunction. Two deaths occurred, none of which was related to arrhythmia. CONCLUSION: The present study found DT was not associated with complications in patients undergoing ICD generator replacement but produced no clinically important information.


Subject(s)
Defibrillators, Implantable , Male , Humans , Aged , Female , Defibrillators, Implantable/adverse effects , Arrhythmias, Cardiac/etiology , Ventricular Fibrillation/diagnosis , Ventricular Fibrillation/etiology , Ventricular Fibrillation/therapy
9.
Clin Appl Thromb Hemost ; 28: 10760296221110879, 2022.
Article in English | MEDLINE | ID: mdl-35866208

ABSTRACT

INTRODUCTION: D-dimer is a small protein fragment produced during fibrinolysis. High D-dimer levels were shown to have prognostic impact in critically ill patients. Nevertheless, data regarding D-dimer's prognostic impact among tertiary care intensive coronary care unit (ICCU) patients is scarce. MATERIAL AND METHOD: All patients admitted to the ICCU between 1-12/2020 were prospectively included. Based on admission D-dimer level, patients were categorized into low and high D-dimer groups (< 500 ng/ml and ≥ 500 ng/ml) and also to age-adjusted D-dimer cutoff (500 ng/ml for ages ≤ 50 years old and age*10 for ages>50 years old). RESULTS AND DISCUSSION: A total of 959 consecutive patients were included, including 296 (27.4%) and 663 (61.3%) patients with low and high D-Dimer levels, respectively. Patients with high D-dimer level were older compared with patients with low D-dimer level (age 70.4 ± 15 and 59 ± 13 years, p = 0.004) and had more comorbidities. The most common primary diagnosis on admission among the low D-dimer group was acute coronary syndrome (ACS) (74.3%), while in the high D-dimer group it was a combination of ACS (33.6%), cardiac structural interventions (26.7%) and various arrhythmias (21.1%). High D-dimer levels were associated with increased mortality rate, even after adjustment for age, gender, comorbidities and left ventricular ejection fraction (LVEF). High D-dimer levels were independently associated with increased overall 1-year mortality rate (HR = 5.8; 95% CI; 1.7-19.1; p = 0.004). CONCLUSION: Elevated D-dimer levels on admission in ICCU patients is an independently poor prognostic factor for in-hospital morbidity and 1-year overall mortality rate following hospitalization.


Subject(s)
Acute Coronary Syndrome , Coronary Care Units , Acute Coronary Syndrome/diagnosis , Aged , Aged, 80 and over , Fibrin Fibrinogen Degradation Products/metabolism , Humans , Intensive Care Units , Middle Aged , Prognosis , Stroke Volume , Ventricular Function, Left
10.
J Clin Med ; 11(5)2022 Feb 26.
Article in English | MEDLINE | ID: mdl-35268370

ABSTRACT

Background: Heart failure (HF) patients with wide QRS often benefit from cardiac resynchronization therapy (CRT), although QRS narrowing does not always occur. The current study investigates the incidence and predictors for QRS narrowing following CRT and its long-term impact on clinical outcomes. Methods: Among individuals undergoing clinically indicated CRT, pre-and post-implantation electrocardiographs were meticulously analyzed for QRS duration change. All-cause mortality and the composite of mortality and HF hospitalizations were retrieved. Results: For 104 patients, mean age 67 years, 25% females, QRS narrowed within days by 20.2 ± 24.7 ms. In 55/104 (53%) QRS narrowed by ≥20 ms ("acute narrowing"). Female gender and baseline QRS predicted acute narrowing. Acute narrowing persisted for 1−6 weeks in 18/20 (90%) and 3−12 months in 21/31 (68%) of patients. During the average follow-up of 41 months, 29/104 (28%) died and 50/104 (48%) met the composite outcome. In a multivariable analysis including comorbidities and cardiac history, prolonged baseline PR interval (HR 1.015, CI 1.008−1.021, p < 0.001) and acute narrowing < 20 ms (HR 3.243, CI 1.593−6.603, p = 0.001) were significant and independent predictors for the composite outcome. Conclusions: Post-CRT acute QRS narrowing ≥ 20 ms is independently associated with favorable long-term outcomes and might be considered as a novel measure for procedural success.

11.
J Cardiovasc Electrophysiol ; 33(4): 618-625, 2022 04.
Article in English | MEDLINE | ID: mdl-35118762

ABSTRACT

BACKGROUND: A novel 3D mapping system (KODEX-EPD, EPD Solutions) enables catheter localization and real-time 3D cardiac mapping. OBJECTIVE: To evaluate left atrium (LA) anatomical mapping accuracy created by the KODEX-EPD system during pulmonary vein isolation (PVI) compared with gold standard computed tomography (CT) images acquired from the same patients before the procedure. METHODS: In 15 consecutive patients who underwent PVI, 3D mapping of the LA was created on the KODEX-EPD system using the Achieve catheter. Pulmonary vein (PV), posterior wall, and appendage anatomy and diameters, were compared to the CT 3D reconstruction measured on the CARTO 3 system. Measurements were done independently by two physicians in each method. Linear correlation and agreement between CT and EPD measurements were assessed by Spearman correlation and Bland-Altman plot. RESULTS: Mean LA mapping time was 7.7 ± 3.6 min. Very high interobserver correlation was found for both EPD and CT measurements (Spearman r = .9). High correlation (r = .75) was found between CT and EPD measurements. Bland-Altman plot method revealed that measurements assessed by EPD were slightly higher than those assessed by CT. Mean difference was 3.5 mm, p < .01. In 2 (13.5%) patients each, disagreement regarding the presence of a left common PV and a right middle accessory vein anatomy was seen. CONCLUSION: The new KODEX-EPD mapping system allows quick and accurate mapping of the LA with high correlation to CT imaging. Some differences in left common and accessory right middle vein anatomy were seen.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Catheter Ablation/methods , Computers , Heart Atria/diagnostic imaging , Heart Atria/surgery , Humans , Imaging, Three-Dimensional/methods , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Tomography, X-Ray Computed
13.
Europace ; 24(5): 817-827, 2022 05 03.
Article in English | MEDLINE | ID: mdl-34652415

ABSTRACT

AIMS: The aims of this study is to characterize the transvenous lead extraction (TLE) population with active (A) compared with passive fixation (PFix) leads and to compare the safety, efficacy, and ease of extracting active fixation (AFix) compared with PFix right atrial (RA) and right ventricular (RV) leads. METHODS AND RESULTS: The European Lead Extraction ConTRolled Registry (ELECTRa) was analysed. Patients were divided into three groups; those with only AFix, only PFix, and combined Fix leads. Three outcomes were defined. Difficult extraction, complete radiological, and clinical success. Multivariate model was used to analyse the independent effect of Fix mechanism on these outcomes. The study included 2815 patients, 1456 (51.7%) with only AFix leads, 982 (34.9%) with only PFix leads, and 377 (13.4%) with combined Fix leads. Patients with AFix leads were younger with shorter lead dwelling time. Infection was the leading cause for TLE among the combined Fix group with lowest rates among AFix group. No difference in complications rates was noted between patients with only AFix vs. PFix leads. Overall, there were 1689 RA (1046 AFix and 643 PFix) and 2617 RV leads (1441 AFix and 1176 PFix). Multivariate model demonstrated that PFix is independently associated with more difficult extraction for both RA and RV leads, lower radiological success in the RA but has no effect on clinical success. CONCLUSION: Mechanism of Fix impact the ease of TLE of RA and RV leads and rates of complete radiological success in the RA but not clinical success. These findings should be considered during implantation and TLE procedures.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Defibrillators, Implantable/adverse effects , Device Removal/adverse effects , Device Removal/methods , Humans , Pacemaker, Artificial/adverse effects , Registries , Retrospective Studies , Treatment Outcome
14.
Heart Rhythm ; 19(2): 206-216, 2022 02.
Article in English | MEDLINE | ID: mdl-34710561

ABSTRACT

BACKGROUND: Cardiac implantable electronic device (CIED) implantation rates as well as the clinical and procedural characteristics and outcomes in patients with known active coronavirus disease 2019 (COVID-19) are unknown. OBJECTIVE: The purpose of this study was to gather information regarding CIED procedures during active COVID-19, performed with personal protective equipment, based on an international survey. METHODS: Fifty-three centers from 13 countries across 4 continents provided information on 166 patients with known active COVID-19 who underwent a CIED procedure. RESULTS: The CIED procedure rate in 133,655 hospitalized COVID-19 patients ranged from 0 to 16.2 per 1000 patients (P <.001). Most devices were implanted due to high-degree/complete atrioventricular block (112 [67.5%]) or sick sinus syndrome (31 [18.7%]). Of the 166 patients in the study survey, the 30-day complication rate was 13.9% and the 180-day mortality rate was 9.6%. One patient had a fatal outcome as a direct result of the procedure. Differences in patient and procedural characteristics and outcomes were found between Europe and North America. An older population (76.6 vs 66 years; P <.001) with a nonsignificant higher complication rate (16.5% vs 7.7%; P = .2) was observed in Europe vs North America, whereas higher rates of critically ill patients (33.3% vs 3.3%; P <.001) and mortality (26.9% vs 5%; P = .002) were observed in North America vs Europe. CONCLUSION: CIED procedure rates during known active COVID-19 disease varied greatly, from 0 to 16.2 per 1000 hospitalized COVID-19 patients worldwide. Patients with active COVID-19 infection who underwent CIED implantation had high complication and mortality rates. Operators should take these risks into consideration before proceeding with CIED implantation in active COVID-19 patients.


Subject(s)
Atrioventricular Block , COVID-19 , Infection Control , Postoperative Complications , Prosthesis Implantation , SARS-CoV-2/isolation & purification , Sick Sinus Syndrome , Aged , Atrioventricular Block/epidemiology , Atrioventricular Block/therapy , COVID-19/diagnosis , COVID-19/epidemiology , COVID-19/therapy , Comorbidity , Defibrillators, Implantable/statistics & numerical data , Female , Global Health/statistics & numerical data , Humans , Infection Control/instrumentation , Infection Control/methods , Infection Control/organization & administration , Male , Middle Aged , Mortality , Outcome Assessment, Health Care , Pacemaker, Artificial/statistics & numerical data , Postoperative Complications/diagnosis , Postoperative Complications/mortality , Prosthesis Implantation/adverse effects , Prosthesis Implantation/instrumentation , Prosthesis Implantation/mortality , Risk Factors , Sick Sinus Syndrome/epidemiology , Sick Sinus Syndrome/therapy , Surveys and Questionnaires
15.
Artif Intell Med ; 122: 102200, 2021 12.
Article in English | MEDLINE | ID: mdl-34823834

ABSTRACT

Patients with life-threatening arrhythmias are often treated with cardiac implantable electronic devices (CIEDs), such as pacemakers and implantable cardioverter defibrillators (ICDs). Recent advancements in CIEDs have enabled advanced functionality and connectivity that make such devices (particularly ICDs) vulnerable to cyber-attacks. One of the most dangerous attacks on CIED ecosystems is a data manipulation attack from a compromised programmer device that sends malicious clinical programmings to the CIED. Such attacks can affect the CIED functioning and impact patient's survival and quality of life. In this paper, we propose Cardio-ML - an automated system for the detection of malicious clinical programmings that is based on machine learning algorithms and a novel missing values resemblance framework. Our system is designed to detect new variants of existing attacks and, more importantly, new unknown (zero-day) attacks, aimed at ICDs. We collected 1651 legitimate clinical programmings from 514 patients, over a four-year period, from programmer devices at two medical centers. Our collection also includes 28 core malicious functionalities created by cardiac electrophysiology experts that were later used to create different variants of malicious programmings. Cardio-ML was evaluated extensively in three comprehensive experiments and showed high detection capabilities in most attack scenarios. We achieved perfect classification results for detecting newly created variants of existing core malicious functionalities, with an AUC of 100%; for completely new unknown (zero-day) malicious clinical programmings, an AUC of 80% was obtained, which is 14% better than the state-of-the-art method. We were able to further improve our detection results by identifying the best combination of legitimate and zero-day malicious programmings in the dataset, achieving an AUC of 87%. CIED clinical programmings have many parameters without values for a large number of samples (programmings). To cope with the extreme amount of missing values in our dataset, we developed a novel missing values-based resemblance framework and evaluated it using three dataset-creation approaches: a standard expert-driven approach, our novel data-driven approach, and a combined approach incorporating both approaches. The results showed that our novel framework handles missing values in the data better than the expert-driven approach which yields an empty dataset. In particular, the combined approach showed a 40% improvement in data utilization compared to the data-driven approach.


Subject(s)
Defibrillators, Implantable , Quality of Life , Ecosystem , Electronics , Humans , Machine Learning
16.
J Clin Med ; 10(8)2021 Apr 17.
Article in English | MEDLINE | ID: mdl-33920719

ABSTRACT

AIM: Evaluate prevalence of heart failure (HF) medications and their association with ventricular arrhythmia (VA) and survival among patients implanted with primary prevention implantable cardiac defibrillator (ICD)/cardiac resynchronization therapy + defibrillator (CRTD) devices. METHODS: Association of treatment and dose (% guideline recommended target) of beta-adrenergic receptor antagonist (BB), angiotensin-antagonists (AngA), and mineralocorticoid-antagonists (MRA), after ICD/CRTD implant with VA and mortality was retrospectively analyzed. RESULTS: Study included 186 HF patients; 42.5% and 57.5% implanted with ICD and CRTD, respectively. During 3.8 (2.1;6.7) years; 52 (28%) had VA and 77 (41.4%) died. Treatment (% of patients) included: BB (83%), AngA (87%), and MRA (59%). Median doses were 25(12.5;50)% of target for all medications. BB treatment >25% target dose was associated with reduced VA incidence. In the multivariable model including age, gender, diabetes, heart rate, and medication doses, increased BB dose was associated with reduced VA (hazard ratio (HR) 0.443 95% CI 0.222-0.885; p = 0.021). In the multivariable model for overall mortality including age, gender, renal disease, VA, and medical treatment, VA was associated with increased mortality (HR 2.672; 95% CI 1.429-4.999; p = 0.002) and AngA treatment was associated with reduced mortality (HR 0.515; 95% CI 0.285-0.929; p = 0.028). CONCLUSIONS: In this cohort of real-life HF patients discharged after ICD/CRTD implant, prevalence of guideline-based HF medications was high, albeit with low doses. Higher BB dose was associated with reduced VA, while AngA was associated with improved survival.

17.
Int J Clin Pract ; 75(4): e13788, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33128270

ABSTRACT

OBJECTIVES: A significant proportion of COVID-19 patients may have cardiac involvement including arrhythmias. Although arrhythmia characterisation and possible predictors were previously reported, there are conflicting data regarding the exact prevalence of arrhythmias. Clinically applicable algorithms to classify COVID patients' arrhythmic risk are still lacking, and are the aim of our study. METHODS: We describe a single-centre cohort of hospitalised patients with a positive nasopharyngeal swab for COVID-19 during the initial Israeli outbreak between 1/2/2020 and 30/5/2020. The study's outcome was any documented arrhythmia during hospitalisation, based on daily physical examination, routine ECG's, periodic 24-hour Holter, and continuous monitoring. Multivariate analysis was used to find predictors for new arrhythmias and create classification trees for discriminating patients with high and low arrhythmic risk. RESULTS: Out of 390 COVID-19 patients included, 28 (7.2%) had documented arrhythmias during hospitalisation, including 23 atrial tachyarrhythmias, combined atrial fibrillation (AF), and ventricular fibrillation, ventricular tachycardia storm, and 3 bradyarrhythmias. Only 7/28 patients had previous arrhythmias. Our study showed a significant correlation between disease severity and arrhythmia prevalence (P < .001) with a low arrhythmic prevalence amongst mild disease patients (2%). Multivariate analysis revealed background heart failure (CHF) and disease severity are independently associated with overall arrhythmia while age, CHF, disease severity, and arrhythmic symptoms are associated with tachyarrhythmias. A novel decision tree using age, disease severity, CHF, and troponin levels was created to stratify patients into high and low risk for developing arrhythmia. CONCLUSIONS: Dominant arrhythmia amongst COVID-19 patients is AF. Arrhythmia prevalence is associated with age, disease severity, CHF, and troponin levels. A novel simple Classification tree, based on these parameters, can discriminate between high and low arrhythmic risk patients.


Subject(s)
Arrhythmias, Cardiac , COVID-19 , Coronavirus , Algorithms , Arrhythmias, Cardiac/complications , Arrhythmias, Cardiac/diagnosis , COVID-19/complications , Humans , Prevalence , SARS-CoV-2
18.
Micromachines (Basel) ; 11(10)2020 Sep 29.
Article in English | MEDLINE | ID: mdl-33003460

ABSTRACT

Advancement in the miniaturization of high-density power sources, electronic circuits, and communication technologies enabled the construction of miniaturized electronic devices, implanted directly in the heart. These include pacing devices to prevent low heart rates or terminate heart rhythm abnormalities ('arrhythmias'), long-term rhythm monitoring devices for arrhythmia detection in unexplained syncope cases, and heart failure (HF) hemodynamic monitoring devices, enabling the real-time monitoring of cardiac pressures to detect and alert for early fluid overload. These devices were shown to prevent HF hospitalizations and improve HF patients' life quality. Pacing devices include permanent pacemakers (PPM) that maintain normal heart rates, defibrillators that are capable of fast detection and the termination of life-threatening arrhythmias, and cardiac re-synchronization devices that improve cardiac function and the survival of HF patients. Traditionally, these devices are implanted via the venous system ('endovascular') using conductors ('endovascular leads/electrodes') that connect the subcutaneous device battery to the appropriate cardiac chamber. These leads are a potential source of multiple problems, including lead-failure and systemic infection resulting from the lifelong exposure of these leads to bacteria within the venous system. One of the important cardiac innovations in the last decade was the development of a leadless PPM functioning without venous leads, thus circumventing most endovascular PPM-related problems. Leadless PPM's consist of a single device, including a miniaturized power source, electronic chips, and fixating mechanism, directly implanted into the cardiac muscle. Only rare device-related problems and almost no systemic infections occur with these devices. Current leadless PPM's sense and pace only the ventricle. However, a novel leadless device that is capable of sensing both atrium and ventricle was recently FDA approved and miniaturized devices that are designed to synchronize right and left ventricles, using novel intra-body inner-device communication technologies, are under final experiments. This review will cover these novel implantable miniaturized cardiac devices and the basic algorithms and technologies that underlie their development. Advancement in the miniaturization of high-density power sources, electronic circuits, and communication technologies enabled the construction of miniaturized electronic devices, implanted directly in the heart. These include pacing devices to prevent low heart rates or terminate heart rhythm abnormalities ('arrhythmias'), long-term rhythm monitoring devices for arrhythmia detection in unexplained syncope cases, and heart failure (HF) hemodynamic monitoring devices, enabling the real-time monitoring of cardiac pressures to detect and alert early fluid overload. These devices were shown to prevent HF hospitalizations and improve HF patients' life quality. Pacing devices include permanent pacemakers (PPM) that maintain normal heart rates, defibrillators that are capable of fast detection and termination of life-threatening arrhythmias, and cardiac re-synchronization devices that improve cardiac function and survival of HF patients. Traditionally, these devices are implanted via the venous system ('endovascular') using conductors ('endovascular leads/electrodes') that connect the subcutaneous device battery to the appropriate cardiac chamber. These leads are a potential source of multiple problems, including lead-failure and systemic infection that result from the lifelong exposure of these leads to bacteria within the venous system. The development of a leadless PPM functioning without venous leads was one of the important cardiac innovations in the last decade, thus circumventing most endovascular PPM-related problems. Leadless PPM's consist of a single device, including a miniaturized power source, electronic chips, and fixating mechanism, implanted directly into the cardiac muscle. Only rare device-related problems and almost no systemic infections occur with these devices. Current leadless PPM's sense and pace only the ventricle. However, a novel leadless device that is capable of sensing both atrium and ventricle was recently FDA approved and miniaturized devices designed to synchronize right and left ventricles, using novel intra-body inner-device communication technologies, are under final experiments. This review will cover these novel implantable miniaturized cardiac devices and the basic algorithms and technologies that underlie their development.

19.
Int J Clin Pract ; 74(10): e13583, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32533880

ABSTRACT

AIMS: Many tachy-brady syndrome (TBS) patients, are implanted a permanent pacemaker (PPM) to allow continuation of anti-arrhythmic drug (AAD) therapy to maintain sinus rhythm. Many of these PPM's are implanted as a preventive measure, in absence of symptomatic bradycardia. Our primary aim was to evaluate pacing use among these patients and find predictors for PPM use. Our secondary aim was to appreciate the portion of these patients who progress to permanent atrial fibrillation (AF). METHODS: Retrospective study of TBS patients implanted a PPM as preventive measure, dividing cases into defined categories regarding highest percent atrial and ventricular pacing documented in PPM clinic visits during 3 year follow-up (F/U) period. Patients' baseline characteristics and AAD therapy were compared between cases with a major (>90%) pacing use and cases with <90% pacing use to find predictors for pacing use. Multivariable logistic regression was applied to identify independent variables associated with major pacing use. RESULTS: Our study included 119 TBS patients. Most (86.5%) TBS patients had a moderate (>50%) pacing use and 58% had a major pacing use. Significant association was found between pre-implant severe sinus bradycardia (<40 bpm), first degree atrioventricular block and amiodarone treatment to major pacing use on univariate analysis and severe sinus bradycardia was significantly associated with major pacing on multivariate analysis as well. Only minority (16.8%) of TBS patients progressed to permanent AF during the study F/U period. CONCLUSION: Our study reveals most TBS patients succeed to maintain sinus rhythm using an AAD with a significant pacing use, suggesting preventive PPM implantation might be advantageous in these cases. Pre-implant severe sinus bradycardia (<40 bpm) is a possible predictor for major pacing use in this population.


Subject(s)
Atrial Fibrillation/therapy , Bradycardia/therapy , Cardiac Pacing, Artificial/statistics & numerical data , Sick Sinus Syndrome/therapy , Aged , Anti-Arrhythmia Agents/therapeutic use , Atrial Fibrillation/drug therapy , Atrial Fibrillation/etiology , Bradycardia/drug therapy , Bradycardia/etiology , Female , Heart Atria/physiopathology , Humans , Male , Middle Aged , Retrospective Studies , Sick Sinus Syndrome/complications , Sick Sinus Syndrome/drug therapy
20.
Int J Cardiol ; 296: 71-75, 2019 12 01.
Article in English | MEDLINE | ID: mdl-31327517

ABSTRACT

AIMS: Patients with left ventricular dysfunction (LVD) and prolonged QRS on surface electrocardiogram are at increased risk for heart failure and death and may benefit from resynchronization therapy. Patients with initial narrow QRS may prolong their QRS during the disease course. The occurrence of delayed QRS prolongation, its predictors and associated risk of heart failure hospitalizations (HFH) or death are currently unknown and the subject of this investigation. METHODS & RESULTS: Patients with LVD, QRS < 120 ms and available follow-up ECGs were retrospectively evaluated for persistent unprovoked QRS prolongation >130 ms. Impact on mortality or HFH was assessed using Cox regression with QRS > 130 ms as a time dependent covariate. Following 178 patients for 30 (10;59) median (IQR) months, 28 (16%) patients prolonged their QRS to >130 ms, reaching a QRS duration of 154 ±â€¯29 ms; LBBB pattern was diagnosed among 14 (50%) patients. Patients with delayed QRS prolongation were older (71.9 ±â€¯11.8 vs 64.4 ±â€¯15.1 years p = 0.014), had larger left ventricle and left atrial diameters (6.3 ±â€¯0.9 vs 5.7 ±â€¯0.9 cm p = 0.010; 4.9 ±â€¯0.6 vs 4.5 ±â€¯0.7 cm p = 0.006, respectively) and wider baseline QRS (104.8 ±â€¯12.6 vs 91.4 ±â€¯14.5 ms p < 0.001) which was linearly associated with late QRS prolongation (p for trend<0.0001). In a multivariable model, age, baseline QRS width and left atrial diameter were significantly associated with delayed QRS prolongation. QRS prolongation at follow-up was independently associated with risk of death or HFH (HR 7.426, 95% CI3.017-18.280, p < 0.0001). CONCLUSION: QRS prolongation occurs in a significant proportion of patients with LVD and portends adverse outcome. Advanced age, prolonged QRS and larger left atria are potential predictors. Routine monitoring is justified and physicians may choose to plan ahead for resynchronization therapy in patients at risk for QRS prolongation.


Subject(s)
Electrocardiography , Ventricular Dysfunction, Left/physiopathology , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Retrospective Studies , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...