Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 33
Filter
1.
Ophthalmic Physiol Opt ; 44(5): 894-909, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38708449

ABSTRACT

PURPOSE: To investigate whether there is a measurable change in meibomian gland morphological characteristics over the course of a day (12 h) and over a month. METHODS: The study enrolled 15 participants who attended a total of 11 study visits spanning a 5-week period. To assess diurnal changes in meibomian glands, seven visits were conducted on a single day, each 2 h apart. For monthly assessment, participants attended an additional visit at the same time of the day every week for three consecutive weeks. Meibography using the LipiView® II system was performed at each visit, and meibomian gland morphological parameters were calculated using custom semi-automated software. Specifically, six central glands were analysed for gland length ratio, gland width, gland area, gland intensity and gland tortuosity. RESULTS: The average meibomian gland morphological metrics did not exhibit significant changes during the course of a day or over a month. Nonetheless, certain individual gland metrics demonstrated notable variation over time, both diurnally and monthly. Specifically, meibomian gland length ratio, area, width and tortuosity exhibited significant changes both diurnally and monthly when assessed on a gland-by-gland basis. CONCLUSIONS: Meibomian glands demonstrated measurable structural change over short periods of time (hours and days). These results have implications for innovation in gland imaging and for developing precision monitoring of gland structure to assess meibomian gland health more accurately.


Subject(s)
Meibomian Glands , Humans , Meibomian Glands/diagnostic imaging , Meibomian Glands/anatomy & histology , Pilot Projects , Female , Male , Middle Aged , Adult , Aged , Meibomian Gland Dysfunction/diagnosis , Meibomian Gland Dysfunction/diagnostic imaging , Tears/physiology , Circadian Rhythm/physiology , Time Factors
2.
Ophthalmic Physiol Opt ; 44(4): 774-786, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38578134

ABSTRACT

PURPOSE: To investigate gaze and behavioural metrics at different viewing distances with multifocal contact lenses (MFCLs), single vision contact lenses (SVCLs) and progressive addition lenses (PALs). METHODS: Fifteen presbyopic contact lens wearers participated over five separate study visits. At each visit, participants were randomly assigned to wear one of five refractive corrections: habitual PAL spectacles, delefilcon A (Alcon Inc.) MFCLs and three separate pairs of delefilcon A single vision lenses worn as distance, intermediate and near corrections. Participants wore a Pupil Core headset to record eye and head movements while performing three visual tasks: reading, visual search and scene observation. Data were investigated using linear regression and post-hoc testing. Parameters of interest included gaze (fixation duration, head movement) and behavioural (reading speed, reading accuracy, visual search time) metrics. RESULTS: Reading speed in SVCLs was significantly faster than in MFCLs and PAL spectacles (F = 16.3, p < 0.0001). Refractive correction worn did not influence visual search times (F = 0.16, p = 0.85). Fixation duration was significantly affected by the type of visual task (F = 60.2, p < 0.001), and an interaction effect was observed between viewing distance and refractive correction (F = 4.3, p = 0.002). There was significantly more horizontal and vertical head movement (F = 3.2, p = 0.01 and F = 3.3, p = 0.01, respectively) during visual search tasks when wearing PAL spectacles compared to SVCLs or MFCLs. CONCLUSION: This work showed that the type of refractive correction affects behavioural metrics such as reading speed and gaze behaviour by affecting horizontal and vertical head movements. The findings of this study suggest that under certain conditions, wearers of MFCLs make fewer head movements compared to PAL spectacles. Gaze behaviour metrics offer a new approach to compare and understand contact lens and spectacle performance, with potential applications including peripheral optical designs for myopia management.


Subject(s)
Contact Lenses , Eyeglasses , Fixation, Ocular , Presbyopia , Reading , Refraction, Ocular , Visual Acuity , Adult , Female , Humans , Male , Middle Aged , Eye Movements/physiology , Fixation, Ocular/physiology , Head Movements/physiology , Presbyopia/physiopathology , Presbyopia/therapy , Refraction, Ocular/physiology , Visual Acuity/physiology , Cross-Over Studies , Prospective Studies
3.
Ophthalmic Physiol Opt ; 44(4): 704-717, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38546401

ABSTRACT

PURPOSE: To investigate differences in key clinical parameters between asymptomatic and highly symptomatic soft contact lens (CL) wearers after 14 h of wear. METHODS: In this pilot investigation, Phase 1 identified asymptomatic (CLDEQ-8 score ≤ 7) and highly symptomatic (CLDEQ-8 score ≥ 20) subjects after fitting with nelfilcon A CLs. Phase 2 investigated the following over a single nelfilcon A CL-wearing day (14 ± 2 h): blinking characteristics, tear meniscus height (TMH), non-invasive tear break-up time (NIBUT), tear film osmolarity and eyelid margin staining. Parameters for the two groups were compared using linear mixed models and post-hoc testing. The relationship between comfort scores and the clinical parameters was also investigated. RESULTS: Overall, 161 and 42 subjects were enrolled into Phase 1 and 2, respectively. Twenty-five asymptomatic and 17 symptomatic subjects completed Phase 2. Lower eyelid TMH was decreased after 14 h in symptomatic compared with asymptomatic subjects (least square mean [LSM] difference -0.04 mm, 95% CI: -0.07, -0.01). Osmolarity was lower in symptomatic than in asymptomatic subjects at fitting (LSM difference -9.89, 95% CI: -18.91, -0.86). Upper eyelid margin staining was greater after 14 h in symptomatic than in asymptomatic subjects (LSM difference 0.53, 95% CI: 0.01, 1.05) and greater after 14 h than baseline in the symptomatic group (LSM difference 0.61, 95% CI: 0.16, 1.07). There was a significant relationship between comfort and upper eyelid margin staining (r = -0.40, 95% CI: -0.63, -0.11) and blink rate (r = -0.31, 95% CI: -0.57, -0.003). CONCLUSION: The potential parameters most effective in differentiating asymptomatic from symptomatic wearers were upper eyelid margin staining and lower TMH. The parameter with the strongest relationship to comfort was upper eyelid margin staining, where higher comfort scores were associated with lower levels of staining.


Subject(s)
Blinking , Contact Lenses, Hydrophilic , Tears , Humans , Contact Lenses, Hydrophilic/adverse effects , Male , Female , Adult , Tears/metabolism , Tears/physiology , Pilot Projects , Blinking/physiology , Young Adult , Osmolar Concentration , Dry Eye Syndromes/diagnosis , Dry Eye Syndromes/etiology , Dry Eye Syndromes/physiopathology , Eyelids
4.
Ophthalmol Sci ; 3(4): 100334, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37920420

ABSTRACT

Purpose: To develop and evaluate a deep learning algorithm for Meibomian gland characteristics calculation. Design: Evaluation of diagnostic technology. Subjects: A total of 1616 meibography images of both the upper (697) and lower (919) eyelids from a total of 282 individuals. Methods: Images were collected using the LipiView II device. All the provided data were split into 3 sets: the training, validation, and test sets. Data partitions used proportions of 70/10/20% and included data from 2 optometry settings. Each set was separately partitioned with these proportions, resulting in a balanced distribution of data from both settings. The images were divided based on patient identifiers, such that all images collected for one participant could end up only in one set. The labeled images were used to train a deep learning model, which was subsequently used for Meibomian gland segmentation. The model was then applied to calculate individual Meibomian gland metrics. Interreader agreement and agreement between manual and automated methods for Meibomian gland segmentation were also carried out to assess the accuracy of the automated approach. Main Outcome Measures: Meibomian gland metrics, including length ratio, area, tortuosity, intensity, and width, were measured. Additionally, the performance of the automated algorithms was evaluated using the aggregated Jaccard index. Results: The proposed semantic segmentation-based approach achieved average aggregated Jaccard index of mean 0.4718 (95% confidence interval [CI], 0.4680-0.4771) for the 'gland' class and a mean of 0.8470 (95% CI, 0.8432-0.8508) for the 'eyelid' class. The result for object detection-based approach was a mean of 0.4476 (95% CI, 0.4426-0.4533). Both artificial intelligence-based algorithms underestimated area, length ratio, tortuosity, widthmean, widthmedian, width10th, and width90th. Meibomian gland intensity was overestimated by both algorithms compared with the manual approach. The object detection-based algorithm seems to be as reliable as the manual approach only for Meibomian gland width10th calculation. Conclusions: The proposed approach can successfully segment Meibomian glands; however, to overcome problems with gland overlap and lack of image sharpness, the proposed method requires further development. The study presents another approach to utilizing automated, artificial intelligence-based methods in Meibomian gland health assessment that may assist clinicians in the diagnosis, treatment, and management of Meibomian gland dysfunction. Financial Disclosures: The authors have no proprietary or commercial interest in any materials discussed in this article.

5.
Clin Exp Optom ; : 1-11, 2023 Nov 21.
Article in English | MEDLINE | ID: mdl-37989323

ABSTRACT

CLINICAL RELEVANCE: Evaluating how Meibomian glands can change in appearance has the potential to advance the understanding of Meibomian gland health and may lead to enhanced diagnosis and therapy. BACKGROUND: This work aimed to investigate Meibomian gland appearance after therapeutic Meibomian gland expression. METHODS: Fifteen subjects attended three study visits over a two-week period. Meibography was performed before and after therapeutic Meibomian gland expression, the following day, and 2 weeks after expression. Six central glands were used to calculate Meibomian gland morphological parameters such as gland length ratio, gland width, gland area, gland tortuosity, and gland contrast. A custom semi-automated image analysis software was used to calculate Meibomian gland metrics. Furthermore, a high-resolution imaging system was developed to capture clear images of the Meibomian glands, free of any artefacts, which were used for precise calculations of Meibomian gland contrast. RESULTS: The expression procedure had a significant impact on Meibomian gland contrast and length ratio immediately afterwards. The least square mean difference (95% CI) from baseline for Michelson contrast was -0.006 (-0.010, -0.001) and -1.048 (-2.063, -0.033) for simple contrast. The least square mean ratio of the gland length ratio immediately after the expression to baseline was 0.758 (0.618, 0.931). CONCLUSIONS: Following therapeutic expression, Meibomian glands exhibit reduced brightness and length. However, within 24 h, they appear to recover and return to their baseline state, indicating a relatively short recovery time. This sheds light on whether meibography is solely focused on capturing gland structure or if it also captures acinar activity. The hyperreflective properties of lipids suggest that the decrease in contrast observed after expression could be attributed to a reduction in the visualisation of acini activity. A decrease in Meibomian gland length ratio implies that the loss of gland structure following treatment may be indicative of a temporary structural alteration.

6.
Ocul Surf ; 28: 213-252, 2023 04.
Article in English | MEDLINE | ID: mdl-37062428

ABSTRACT

Eye strain when performing tasks reliant on a digital environment can cause discomfort, affecting productivity and quality of life. Digital eye strain (the preferred terminology) was defined as "the development or exacerbation of recurrent ocular symptoms and/or signs related specifically to digital device screen viewing". Digital eye strain prevalence of up to 97% has been reported, due to no previously agreed definition/diagnostic criteria and limitations of current questionnaires which fail to differentiate such symptoms from those arising from non-digital tasks. Objective signs such as blink rate or critical flicker frequency changes are not 'diagnostic' of digital eye strain nor validated as sensitive. The mechanisms attributed to ocular surface disease exacerbation are mainly reduced blink rate and completeness, partial/uncorrected refractive error and/or underlying binocular vision anomalies, together with the cognitive demand of the task and differences in position, size, brightness and glare compared to an equivalent non-digital task. In general, interventions are not well established; patients experiencing digital eye strain should be provided with a full refractive correction for the appropriate working distances. Improving blinking, optimizing the work environment and encouraging regular breaks may help. Based on current, best evidence, blue-light blocking interventions do not appear to be an effective management strategy. More and larger clinical trials are needed to assess artificial tear effectiveness for relieving digital eye strain, particularly comparing different constituents; a systematic review within the report identified use of secretagogues and warm compress/humidity goggles/ambient humidifiers as promising strategies, along with nutritional supplementation (such as omega-3 fatty acid supplementation and berry extracts).


Subject(s)
Asthenopia , Dry Eye Syndromes , Eye Diseases , Humans , Quality of Life , Asthenopia/etiology , Asthenopia/diagnosis , Tears , Life Style , Dry Eye Syndromes/diagnosis , Dry Eye Syndromes/complications
7.
Transl Vis Sci Technol ; 12(2): 9, 2023 02 01.
Article in English | MEDLINE | ID: mdl-36749580

ABSTRACT

Purpose: To develop and evaluate a custom imaging system to provide high-resolution, wide depth-of-field, reflection-free, multispectral infrared (IR) imaging of the Meibomian glands. Methods: Lower eyelids of 15 volunteers were everted to obtain multispectral images of the Meibomian glands with custom imaging setup. Photographs were captured at 10 different ISO settings (from underexposure to overexposure) and using nine IR imaging filters (ranging from 600 nm to 1000 nm in 50-nm steps). Meibomian gland contrast (simple and Michelson) was calculated for the images to choose an optimal wavelength for Meibomian gland imaging and to determine differences in contrast across individuals. Results: The overall linear regression model showed a significant effect of wavelength on Meibomian gland contrast (Simple contrast: F = 7.24, P < 0.0001; Michelson contrast: F = 7.19, P < 0.0001). There was a significant negative correlation between Meibomian gland contrast and Meibomian gland depth for 750-nm IR filter (ρs= -0.579; P = 0.026). Conclusions: Meibomian gland contrast varies across individuals and depends on Meibomian gland depth. IR filter of 750 nm is the optimal choice for Meibomian gland imaging because it provides images of greatest contrast. Translational Relevance: This study adds to our understanding of Meibomian gland imaging. It has successfully demonstrated that Meibomian glands that are deeper in the tarsal plate require longer wavelengths for imaging.


Subject(s)
Meibomian Glands , Humans , Meibomian Glands/diagnostic imaging
8.
Biol Psychiatry Glob Open Sci ; 2(4): 480-488, 2022 Oct.
Article in English | MEDLINE | ID: mdl-36324657

ABSTRACT

Background: Hoarding disorder is a chronic psychiatric condition of increasing public health concern. Recent investigation suggests a positive association between hoarding severity and insomnia symptoms. However, these findings have yet to be replicated, and the prevalence and type of sleep impairment experienced by individuals with clinically relevant hoarding symptoms (CHSs) are not known. Methods: This analysis of 20,473 members of the internet-based Brain Health Registry uses multivariate logistic regression modeling and structural equation modeling to evaluate the relationship between hoarding symptoms, sleep impairment, adverse health, and cognitive functioning. Results: More than 12% of study participants endorsed CHSs or subclinical hoarding symptoms. After adjustment for demographic characteristics and psychiatric comorbidity, individuals with CHSs reported increased odds of sleep impairment in nearly all domains. The odds of poor sleep quality (adjusted odds ratio, 2.07; 95% CI, 1.83-2.34), sleep disturbances (adjusted odds ratio, 2.15; 95% CI, 1.91-2.43), and daytime dysfunction (adjusted odds ratio, 5.84; 95% CI, 5.12-6.65) were two- to fivefold higher for individuals with CHSs compared with those without. For all measures, the proportion of individuals reporting sleep impairment increased with hoarding severity. In our structural equation model, sleep impairment acted as a partial mediator on the indirect pathways from hoarding to subjective cognitive complaints and poorer quality of life. Conclusions: Identification of sleep problems among those with hoarding symptoms is a critical component of hoarding assessment. Additional research is needed to better understand the mechanisms underlying the observed relationships, including neurobiological underpinnings, and to examine the role of sleep management in treatment for hoarding behaviors.

9.
BMC Psychiatry ; 22(1): 647, 2022 10 15.
Article in English | MEDLINE | ID: mdl-36241971

ABSTRACT

BACKGROUND: Hoarding symptoms are associated with functional impairment, though investigation of disability among individuals with hoarding disorder has largely focused on clutter-related impairment to home management activities and difficulties using space because of clutter. This analysis assesses disability among individuals with hoarding symptoms in multiple domains of everyday functioning, including cognition, mobility, self-care, interpersonal and community-level interactions, and home management. The magnitude of the association between hoarding and disability was compared to that of medical and psychiatric disorders with documented high disability burden, including major depressive disorder (MDD), diabetes, and chronic pain. METHODS: Data were cross-sectionally collected from 16,312 adult participants enrolled in an internet-based research registry, the Brain Health Registry. Pearson's chi-square tests and multivariable logistic regression models were used to quantify the relationship between hoarding and functional ability relative to MDD, diabetes, and chronic pain. RESULTS: More than one in ten participants endorsed clinical (5.7%) or subclinical (5.7%) hoarding symptoms (CHS and SCHS, respectively). After adjusting for participant demographic characteristics and psychiatric and medical comorbidity, CHS and SCHS were associated with increased odds of impairment in all domains of functioning. Moderate to extreme impairment was endorsed more frequently by those with CHS or SCHS compared to those with self-reported MDD, diabetes, and/or chronic pain in nearly all domains (e.g., difficulty with day-to-day work or school: CHS: 18.7% vs. MDD: 11.8%, p < 0.0001) except mobility and self-care. While those with current depressive symptoms endorsed higher rates of impairment than those with hoarding symptoms, disability was most prevalent among those endorsing both hoarding and comorbid depressive symptoms. CONCLUSIONS: Hoarding symptoms are associated with profound disability in all domains of functioning. The burden of hoarding is comparable to that of other medical and psychiatric illnesses with known high rates of functional impairment. Future studies should examine the directionality and underlying causality of the observed associations, and possibly identify target interventions to minimize impairment associated with hoarding symptomatology.


Subject(s)
Chronic Pain , Depressive Disorder, Major , Diabetes Mellitus , Hoarding , Mental Disorders , Adult , Humans
10.
Ocul Surf ; 25: 119-128, 2022 07.
Article in English | MEDLINE | ID: mdl-35724917

ABSTRACT

Meibography is a visualisation technique that has been used for over 40 years. There have been significant improvements in image quality, examination technique and image interpretation over this period. Although meibography has received sporadic reviews in the past, an updated review is timely due to the rapid recent rise of relevant technology and advances in both image processing and artificial intelligence. The primary aim of this paper is to review recent research into Meibomian gland imaging and update the community about the most relevant technologies and approaches used in the field.


Subject(s)
Dry Eye Syndromes , Eyelid Diseases , Artificial Intelligence , Dry Eye Syndromes/diagnosis , Eyelid Diseases/diagnosis , Humans , Image Processing, Computer-Assisted , Meibomian Glands/diagnostic imaging , Tears
11.
Cont Lens Anterior Eye ; 45(5): 101596, 2022 10.
Article in English | MEDLINE | ID: mdl-35466057

ABSTRACT

PURPOSE: The aim of this pilot study was to investigate the initial effect of contact lens wear on spontaneous blink characteristics. METHODS: This was a randomised, crossover pilot study. Spontaneous blinking was recorded using a high-speed infrared camera in ten subjects with three different soft contact lenses (spherical hydrogel, spherical silicone hydrogel and toric hydrogel), one rigid contact lens and without contact lenses. Custom semi-automated software was used to determine palpebral aperture height, interblink interval (IBI), blink speed, blink completeness and blink duration. RESULTS: The IBI was significantly greater for non-lens wear compared with the silicone hydrogel [ratio (95% CI): 1.34 (1.16, 1.55), p < 0.0001], toric hydrogel [1.28 (1.10, 1.48), p = 0.0001] and rigid corneal lenses [1.48 (1.27, 1.73), p < 0.0001]. The spherical silicone hydrogel lens showed greater closing-phase speed than non-lens wear [mean difference (95% CI): 27.4 (5.6, 49.1) mm/s, p = 0.006]. Shorter total blink duration was found for non-lens wear compared with any of the lens types [spherical hydrogel: ratio 0.89 (0.81, 0.98), p = 0.01; spherical silicone hydrogel: 0.87 (0.80, 0.95), p = 0.0001; toric hydrogel: 0.90 (0.83, 0.98), p = 0.004; and rigid corneal: 0.88 (0.82, 0.96), p = 0.0004]. Opening-phase speed (p = 0.12) and blink completeness metrics (all p > 0.5) were not influenced by wearing condition. CONCLUSION: This work showed that short-term contact lens wear influenced the palpebral aperture height, IBI, speed and duration of the blink, and the effect is dependent on the contact lens type. The completeness of the blink was not altered by contact lens wear. Future work should be conducted to assess the effect of long-term wear of different contact lens types on blink characteristics. The measurement of spontaneous blinking characteristics represents an immediate, sensitive and non-invasive evaluation of the impact of a contact lens on the ocular surface.


Subject(s)
Blinking , Contact Lenses, Hydrophilic , Humans , Hydrogel, Polyethylene Glycol Dimethacrylate , Hydrogels , Pilot Projects , Silicones
12.
J Psychiatr Res ; 149: 68-75, 2022 05.
Article in English | MEDLINE | ID: mdl-35255385

ABSTRACT

Hoarding disorder often results in debilitating functional impairment and may also compromise health-related quality of life (QoL). This study investigated the association between hoarding behavior and QoL relative to six highly impairing medical and psychiatric disorders in a sample of 20,722 participants enrolled in the internet-based Brain Health Registry. Nearly 1 in 8 participants (12.2%) endorsed clinically relevant hoarding symptoms (CHS). In separate multivariable linear regression models, hoarding was more strongly associated with mental QoL than diabetes (Standardizedß = -0.21, 95% CI: [-0.22, -0.20] vs. -0.01 [-0.02, 0.0]), heart disease (-0.22 [-0.23, -0.20] vs. 0.00 [-0.02, 0.01]), chronic pain (-0.18 [-0.19, -0.16] vs. -0.12 [-0.13, -0.10]), post-traumatic stress disorder (PTSD; -0.20 [-0.22, -0.19] vs. -0.07 [-0.09, -0.06]), and substance use disorder (SUD; -0.21 [-0.23, -0.20] vs. -0.04 [-0.05, -0.03]). Similarly, CHS was more strongly negatively associated with physical QoL than diabetes (-0.11 [-0.10, -0.12] vs. -0.08 [-0.06, -0.09]), major depressive disorder (-0.09 [-0.10, -0.08] vs. -0.05 [-0.06, 0.03]), PTSD (-0.11 [-0.12, -0.10] vs. -0.08 [-0.09, -0.07]), and SUD (-0.12 [-0.13, -0.09] vs. -0.01 [-0.02, 0.00]). Higher hoarding severity was associated with reductions in both mental (Standardizedß = -0.28, ΔR2 = 0.08, p < 0.0001) and physical (ß = -0.12, ΔR2 = 0.02, p < 0.0001) QoL, though the strength of the relationship between hoarding symptoms and QoL varied with depression severity. Efforts to improve the overall QoL and well-being of those with CHS are needed.


Subject(s)
Depressive Disorder, Major , Hoarding Disorder , Hoarding , Chronic Disease , Cost of Illness , Hoarding/psychology , Humans , Quality of Life/psychology
13.
Cont Lens Anterior Eye ; 45(5): 101516, 2022 10.
Article in English | MEDLINE | ID: mdl-34607768

ABSTRACT

PURPOSE: To test the hypothesis that various subjective ocular and task-related parameters associated with wearing a face mask would be better in neophyte contact lens (CL) wear compared to habitual spectacle (Sp) wear. METHODS: Thirty participants were randomised to continue in Sp (n = 15) or wear somofilcon A daily disposable CL (n = 15) ('group'). A surgical face mask (Type II R) was worn for at least one hour per day on four or more days per week. After two weeks, participants completed the Quality of Life Impact of Refractive Correction Questionnaire (QIRC), a two-part face mask usability questionnaire and graded ocular-related symptoms using 0-100 visual analogue scales. RESULTS: There was no difference between groups for overall QIRC score but some individual question scores reflected better quality of life in the CL: 'outdoor activities', 'keep fit' and 'able to do things' (all p < 0.05). Differences in favour of the CL were seen for the following in the face mask usability questionnaire: 'breathing', 'heat', 'comfort on ears', 'overall comfort', 'walking', 'driving', 'reading', 'computer use', 'exercising' and 'socialising' (all p < 0.05). Significant differences were also seen for the 0-100 VAS symptoms probing vision quality in favour of the CL: glare, distance and near vision, fogging, restricted field of view and peripheral blur. CONCLUSION: This work supports anecdotal reports that CL are a better vision correction option than Sp when used in conjunction with a face mask. Participants reported a range of benefits to the CL/face mask combination for vision-related symptoms, breathing and heat-related symptoms and a number of day-to-day activities including walking, driving and exercising. All of the benefits relating to the CL are likely to result in improved adherence to face mask use. Overall, the findings of this work suggest that where possible, CL should be the preferred vision correction option for people using face masks.


Subject(s)
Contact Lenses, Hydrophilic , Contact Lenses , Eyeglasses , Humans , Masks , Patient Satisfaction , Quality of Life , Visual Acuity
14.
Cont Lens Anterior Eye ; 44(2): 398-430, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33775384

ABSTRACT

Contact lenses in the future will likely have functions other than correction of refractive error. Lenses designed to control the development of myopia are already commercially available. Contact lenses as drug delivery devices and powered through advancements in nanotechnology will open up further opportunities for unique uses of contact lenses. This review examines the use, or potential use, of contact lenses aside from their role to correct refractive error. Contact lenses can be used to detect systemic and ocular surface diseases, treat and manage various ocular conditions and as devices that can correct presbyopia, control the development of myopia or be used for augmented vision. There is also discussion of new developments in contact lens packaging and storage cases. The use of contact lenses as devices to detect systemic disease has mostly focussed on detecting changes to glucose levels in tears for monitoring diabetic control. Glucose can be detected using changes in colour, fluorescence or generation of electric signals by embedded sensors such as boronic acid, concanavalin A or glucose oxidase. Contact lenses that have gained regulatory approval can measure changes in intraocular pressure to monitor glaucoma by measuring small changes in corneal shape. Challenges include integrating sensors into contact lenses and detecting the signals generated. Various techniques are used to optimise uptake and release of the drugs to the ocular surface to treat diseases such as dry eye, glaucoma, infection and allergy. Contact lenses that either mechanically or electronically change their shape are being investigated for the management of presbyopia. Contact lenses that slow the development of myopia are based upon incorporating concentric rings of plus power, peripheral optical zone(s) with add power or non-monotonic variations in power. Various forms of these lenses have shown a reduction in myopia in clinical trials and are available in various markets.


Subject(s)
Contact Lenses , Myopia , Presbyopia , Refractive Errors , Eye , Humans , Refraction, Ocular , Refractive Errors/diagnosis , Refractive Errors/therapy
15.
iScience ; 24(2): 102047, 2021 Feb 19.
Article in English | MEDLINE | ID: mdl-33554060

ABSTRACT

The efficacy of ALVAC-based HIV and SIV vaccines in humans and macaques correlates with antibodies to envelope variable region 2 (V2). We show here that vaccine-induced antibodies to SIV variable region 1 (V1) inhibit anti-V2 antibody-mediated cytotoxicity and reverse their ability to block V2 peptide interaction with the α4ß7 integrin. SIV vaccines engineered to delete V1 and favor an α helix, rather than a ß sheet V2 conformation, induced V2-specific ADCC correlating with decreased risk of SIV acquisition. Removal of V1 from the HIV-1 clade A/E A244 envelope resulted in decreased binding to antibodies recognizing V2 in the ß sheet conformation. Thus, deletion of V1 in HIV envelope immunogens may improve antibody responses to V2 virus vulnerability sites and increase the efficacy of HIV vaccine candidates.

16.
Cont Lens Anterior Eye ; 44(4): 101387, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33308907

ABSTRACT

PURPOSE: This work set out to investigate if there was an association between subjective comfort and both subjective and measured vision during the use of contemporary daily disposable soft toric contact lenses. METHODS: Thirty-eight habitual soft contact lens wearers wore each of three daily disposable toric lenses for one week in a prospective, crossover, randomised, single-masked study. The following clinical measures were recorded at dispensing and follow-up visits: biomicroscopy scores, lens fitting (including rotation and rotational stability), high and low contrast visual acuity, subjective vision quality and subjective ocular surface comfort. Subjective scores were collected using 0-10 numerical grading scales. Comfort scores were analysed using a linear regression model with age, sex, visit, phase of crossover ('phase'), lens type, lens rotation, lens rotational stability, visual acuity, cylinder power and subjective vision quality as factors of interest and then refined using backward stepwise regression. RESULTS: Thirty six participants (31.1 ± 13.5 years) completed the study. Comfort scores were found to be associated with subjective vision quality (F = 127.0 ; p < 0.0001), phase (F = 7.2; p = 0.001) and lens type (F = 4.9; p = 0.009). Greater comfort scores were observed with greater subjective vision quality scores. Visual acuity was not statistically significant in the model. CONCLUSION: This work suggests that symptoms of ocular discomfort may be more intense if there is also perceived visual compromise in daily disposable soft toric lenses. There was a stronger positive correlation between comfort and subjective vision quality compared with comfort and measured visual acuity.


Subject(s)
Contact Lenses, Hydrophilic , Patient Satisfaction , Humans , Prospective Studies , Vision, Ocular , Visual Acuity
17.
Ophthalmic Physiol Opt ; 40(4): 519-528, 2020 07.
Article in English | MEDLINE | ID: mdl-32452570

ABSTRACT

PURPOSE: Development and validation of a non-invasive imaging system to capture spontaneous blinking and characterise blink dynamics using a custom image analysis algorithm. METHODS: A pilot study investigated the influence of illumination type on blink dynamics. Spontaneous blinking was recorded in eight subjects using a high-speed camera under two illumination conditions: white light and infrared. Custom semi-automated software assessed palpebral aperture height (PAH), blink rate, blink speed, blink completeness and blink duration. The main clinical study compared two different image analysis techniques. Spontaneous blinking was recorded in 20 subjects using a high-speed infrared camera. Blink speed and duration were determined using two techniques: manual tracking and semi-automated tracking. Agreement between the two techniques was assessed using Bland-Altman analysis. Coefficients of repeatability (COR) were calculated for the semi-automated technique. RESULTS: There were significant differences between white light and infrared illumination for PAH (p < 0.0001), blink rate (p = 0.04), closing speed (p = 0.009), opening speed (p < 0.0001) and blink duration (p = 0.0003). The mean differences (95% limits of agreement) between the two techniques were 0.6 mm s-1 (-15.9 to 17.0) closing speed, 1.5 mm s-1 (-6.8 to 9.8) opening speed, 2.4 ms (-6.8 to 11.5) closed phase duration and 5.0 ms (-19.4 to 29.3) total blink duration. COR values were 10.1 mm s-1 closing speed, 3.7 mm s-1 opening speed, 6.7 ms closed phase duration and 11.2 ms total blink duration. CONCLUSIONS: This study has shown that spontaneous blinking can be characterised using a non-invasive imaging system. The semi-automated analysis provides a rapid characterisation of blink dynamics, allowing its application in large-scale trials in a number of clinical areas.


Subject(s)
Blinking/physiology , Diagnostic Imaging/methods , Eyelids/physiology , Image Processing, Computer-Assisted/instrumentation , Software , Adult , Female , Humans , Male , Pilot Projects , Video Recording
18.
Cont Lens Anterior Eye ; 43(5): 476-483, 2020 10.
Article in English | MEDLINE | ID: mdl-32151528

ABSTRACT

PURPOSE: To investigate ocular discomfort during contact lens wear using a wrist-mounted electronic 'lens awareness logger' (LAL). METHODS: Thirty symptomatic contact lens wearers wore study contact lenses for three days. On the first two days, two lens types which are known to differ in end-of-day comfort (lens A: senofilcon A and lens B: balafilcon A), were worn as a matching pair (randomised order). On day three, a pair of lens B was worn. On each day, the participant used a LAL. On day one and two, the participant pressed a button on the LAL whenever they became aware of their lenses due to discomfort. On day three, the participant used a multiple click protocol (1 = mild awareness to 3 = severe awareness) to report discomfort. RESULTS: LAL events were similar on days one and two (17.3 vs. 15.8 events per day). There were significantly more LAL events for lens B (21.6 events per day) in comparison with lens A (11.6 events per day) (p = 0.006). The LAL event profile highlighted peaks in awareness following lens application and towards the end of the wearing cycle. Comparison of the LAL event profile for the two lens types showed significant differences in lens awareness, particularly in the first half of the wearing cycle. LAL events on day 3, showed a uniform distribution of single and double clicks through the day, but a marked peak in triple clicks in the last two hours of lens wear. CONCLUSION: The LAL was able to differentiate between the study lenses and demonstrated differences in their LAL event profiles. Lens awareness associated with discomfort appeared to increase not only in frequency, but also in intensity towards the end of the wearing cycle. The ability of the LAL to track lens awareness suggests it is likely to be a useful tool in furthering understanding of ocular discomfort.


Subject(s)
Contact Lenses, Hydrophilic , Contact Lenses , Contact Lenses, Hydrophilic/adverse effects , Electronics , Eye , Humans , Patient Satisfaction , Vision, Ocular , Wrist
19.
Cont Lens Anterior Eye ; 43(4): 378-388, 2020 08.
Article in English | MEDLINE | ID: mdl-31451311

ABSTRACT

PURPOSE: Fluorescein-labelled wheat germ agglutinin (F-WGA) acts as a marker for ocular surface mucins. This clinical study sought to investigate whether the degree of F-WGA fluorescence observed at the ocular surface differed between symptomatic contact lens wearers, asymptomatic contact lens wearers and non-contact lens wearers, using a novel imaging system. METHODS: Twenty-five participants (10 symptomatic contact lens wearers, 10 asymptomatic contact lens wearers and 5 non-contact lens wearers) attended a single study visit. Photographs of the cornea, bulbar and tarsal conjunctiva were captured following application of F-WGA solution. RESULTS: The imaging system captured high-resolution images of F-WGA fluorescence at the ocular surface. The degree of fluorescence differed between the ocular surface regions (p < 0.001). A significant difference in fluorescence was observed between participant groups for the cornea (p = 0.01), with both the symptomatic and asymptomatic contact lens wearers showing lower fluorescence than the non-lens wearers. F-WGA associated fluorescence appeared diminished in the lid wiper region of the symptomatic lens wearers, compared to the asymptomatic group (p = 0.025). CONCLUSION: The use of F-WGA as a clinical marker for ocular surface mucins allows an improved understanding of their distribution across the ocular surface. Contact lens wear appears to negatively impact mucin density across the ocular surface, with the most marked effect on the cornea. F-WGA fluorescence appeared diminished in the lid wiper region for the symptomatic contact lens wearing group, indicating that mechanical interaction in this region may play a role in the aetiology of contact lens discomfort. Given the ability of F-WGA to disclose mucin distribution across the ocular surface it is likely to be a key clinical tool in furthering our understanding of (i) the aetiology of contact lens related discomfort, (ii) contact lens designs/materials to minimise interaction with the ocular surface and (iii) dry eye disease and other ocular surface diseases.


Subject(s)
Contact Lenses, Hydrophilic , Dry Eye Syndromes , Conjunctiva , Humans , Mucins , Optical Imaging
20.
Cont Lens Anterior Eye ; 42(5): 569-574, 2019 10.
Article in English | MEDLINE | ID: mdl-31097309

ABSTRACT

PURPOSE: To develop and evaluate a wearable device (the lens awareness logger, LAL) to record subjective lens awareness during contact lens wear. METHODS: The LAL is a compact electronic event-logging device incorporating a tactile switch and belt-clip. Forty contact lens wearers (20 symptomatic and 20 asymptomatic) took part in a clinical evaluation of the LAL device. Subjects were instructed to wear their habitual soft contact lenses for 2 days (>8 h wear) and use the LAL device. Subjects activated the LAL device immediately prior to lens application and deactivated it following lens removal. If a subject became aware of their contact lenses at any point throughout the wear period they were instructed to depress the button on the LAL device. RESULTS: The mean number of lens awareness events per hour was 1.3, although there was substantial variation between subjects (standard deviation 1.4). The distribution of lens awareness events throughout the contact lens wearing period showed significantly elevated awareness following lens application and prior to lens removal (p < 0.0001). In addition, symptomatic subjects had a statistically higher percentage of LAL events in the second half of the lens-wearing day compared with asymptomatic subjects (p = 0.02). The LAL findings for each subject appear consistent across the two days (i.e. no fatigue or learning effect). The LAL device was well accepted by subjects with 38 of the 40 subjects reporting it was either 'very easy' or 'fairly easy' to use. CONCLUSION: The LAL device was able to monitor ocular comfort throughout a period of contact lens wear and was well accepted by subjects. The ability of the LAL device to track ocular awareness events through the day, with high temporal resolution, means it is likely to be a key tool to further understanding of contact lens associated discomfort and dry eye disease.


Subject(s)
Contact Lenses, Hydrophilic , Monitoring, Physiologic/methods , Patient Comfort/statistics & numerical data , Patient Satisfaction , Wearable Electronic Devices , Adolescent , Adult , Dry Eye Syndromes/physiopathology , Female , Humans , Male , Middle Aged , Prospective Studies , Surveys and Questionnaires
SELECTION OF CITATIONS
SEARCH DETAIL
...