Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Malar J ; 19(1): 392, 2020 Nov 04.
Article in English | MEDLINE | ID: mdl-33148265

ABSTRACT

BACKGROUND: Malaria rapid diagnostic tests (RDTs) have greatly improved access to diagnosis in endemic countries. Most RDTs detect Plasmodium falciparum histidine-rich protein 2 (HRP2), but their sensitivity is seriously threatened by the emergence of pfhrp2-deleted parasites. RDTs detecting P. falciparum or pan-lactate dehydrogenase (Pf- or pan-LDH) provide alternatives. The objective of this study was to systematically assess the performance of malaria RDTs against well-characterized pfhrp2-deleted P. falciparum parasites. METHODS: Thirty-two RDTs were tested against 100 wild-type clinical isolates (200 parasites/µL), and 40 samples from 10 culture-adapted and clinical isolates of pfhrp2-deleted parasites. Wild-type and pfhrp2-deleted parasites had comparable Pf-LDH concentrations. Pf-LDH-detecting RDTs were also tested against 18 clinical isolates at higher density (2,000 parasites/µL) lacking both pfhrp2 and pfhrp3. RESULTS: RDT positivity against pfhrp2-deleted parasites was highest (> 94%) for the two pan-LDH-only RDTs. The positivity rate for the nine Pf-LDH-detecting RDTs varied widely, with similar median positivity between double-deleted (pfhrp2/3 negative; 63.9%) and single-deleted (pfhrp2-negative/pfhrp3-positive; 59.1%) parasites, both lower than against wild-type P. falciparum (93.8%). Median positivity for HRP2-detecting RDTs against 22 single-deleted parasites was 69.9 and 35.2% for HRP2-only and HRP2-combination RDTs, respectively, compared to 96.0 and 92.5% for wild-type parasites. Eight of nine Pf-LDH RDTs detected all clinical, double-deleted samples at 2,000 parasites/µL. CONCLUSIONS: The pan-LDH-only RDTs evaluated performed well. Performance of Pf-LDH-detecting RDTs against wild-type P. falciparum does not necessarily predict performance against pfhrp2-deleted parasites. Furthermore, many, but not all HRP2-based RDTs, detect pfhrp2-negative/pfhrp3-positive samples, with implications for the HRP2-based RDT screening approach for detection and surveillance of HRP2-negative parasites.


Subject(s)
Antigens, Protozoan/genetics , Diagnostic Tests, Routine/statistics & numerical data , Gene Deletion , Malaria, Falciparum/diagnosis , Plasmodium falciparum/genetics , Protozoan Proteins/genetics , Malaria, Falciparum/epidemiology
2.
Malar J ; 18(1): 387, 2019 Dec 02.
Article in English | MEDLINE | ID: mdl-31791354

ABSTRACT

Malaria rapid diagnostic tests (RDTs) emerged in the early 1990s into largely unregulated markets, and uncertain field performance was a major concern for the acceptance of tests for malaria case management. This, combined with the need to guide procurement decisions of UN agencies and WHO Member States, led to the creation of an independent, internationally coordinated RDT evaluation programme aiming to provide comparative performance data of commercially available RDTs. Products were assessed against Plasmodium falciparum and Plasmodium vivax samples diluted to two densities, along with malaria-negative samples from healthy individuals, and from people with immunological abnormalities or non-malarial infections. Three measures were established as indicators of performance, (i) panel detection score (PDS) determined against low density panels prepared from P. falciparum and P. vivax wild-type samples, (ii) false positive rate, and (iii) invalid rate, and minimum criteria defined. Over eight rounds of the programme, 332 products were tested. Between Rounds 1 and 8, substantial improvements were seen in all performance measures. The number of products meeting all criteria increased from 26.8% (11/41) in Round 1, to 79.4% (27/34) in Round 8. While products submitted to further evaluation rounds under compulsory re-testing did not show improvement, those voluntarily resubmitted showed significant increases in P. falciparum (p = 0.002) and P. vivax PDS (p < 0.001), with more products meeting the criteria upon re-testing. Through this programme, the differentiation of products based on comparative performance, combined with policy changes has been influential in the acceptance of malaria RDTs as a case-management tool, enabling a policy of parasite-based diagnosis prior to treatment. Publication of product testing results has produced a transparent market allowing users and procurers to clearly identify appropriate products for their situation, and could form a model for introduction of other, broad-scale diagnostics.


Subject(s)
Diagnostic Tests, Routine/statistics & numerical data , Malaria, Falciparum/diagnosis , Malaria, Vivax/diagnosis , World Health Organization , Humans , Plasmodium falciparum/isolation & purification , Plasmodium vivax/isolation & purification , Sensitivity and Specificity
3.
Malar J ; 17(1): 29, 2018 Jan 15.
Article in English | MEDLINE | ID: mdl-29334955

ABSTRACT

BACKGROUND: Malaria rapid diagnostic tests (RDTs) are becoming widely adopted for case management at community level. However, reports and anecdotal observations indicate that the blood transfer step poses a significant challenge to many users. This study sought to evaluate the inverted cup device in the hands of health workers in everyday clinical practice, in comparison with the plastic pipette, and to determine the volume accuracy of the device made of a lower-cost plastic. METHODS: The volume accuracy of inverted cup devices made of two plastics, PMMA and SBC, was compared by transferring blood 150 times onto filter paper and comparing the blood spot areas with those produced by 20 reference transfers with a calibrated micropipette. The ease of use, safety and acceptability of the inverted cup device and the pipette were evaluated by 50 health workers in Nigeria. Observations were recorded on pre-designed questionnaires, by the health workers themselves and by trained observers. Focus group discussions were also conducted. RESULTS: The volume accuracy assessment showed that the device made from the low-cost material (SBC) delivered a more accurate volume (mean 5.4 µL, SD 0.48 µL, range 4.5-7.0 µL) than the PMMA device (mean 5.9 µL, SD 0.48 µL, range 4.9-7.2 µL). The observational evaluation demonstrated that the inverted cup device performed better than the pipette in all aspects, e.g. higher proportions of health workers achieved successful blood collection (96%, vs. 66%), transfer of the required blood volume (90%, vs. 58%), and blood deposit without any loss (95%, vs. 50%). Majority of health workers also considered it' very easy' to use (81%),'very appropriate' for everyday use (78%), and 50% of them reported that it was their preferred BTD. CONCLUSIONS: The good volume accuracy and high acceptability of the inverted cup device shown in this study, along with observed ease of use and safety in hands of health workers, further strengthens prior findings which demonstrated its higher accuracy as compared with other BTDs in a laboratory setting. Altogether, these studies suggest that the inverted cup device should replace other types of devices for use in day-to-day malaria diagnosis with RDTs.


Subject(s)
Clinical Competence/statistics & numerical data , Community Health Workers/statistics & numerical data , Diagnostic Tests, Routine/methods , Malaria/diagnosis , Diagnostic Tests, Routine/statistics & numerical data , Focus Groups , Humans , Nigeria
4.
Malar J ; 16(1): 128, 2017 Mar 24.
Article in English | MEDLINE | ID: mdl-28340585

ABSTRACT

BACKGROUND: Rapid diagnostic tests (RDTs) are today the most widely used method for malaria diagnosis and are recommended, alongside microscopy, for the confirmation of suspected cases before the administration of anti-malarial treatment. The diagnostic performance of RDTs, as compared to microscopy or PCR is well described but the actual analytical sensitivity of current best-in-class tests is poorly documented. This value is however a key performance indicator and a benchmark value needed to developed new RDTs of improved sensitivity. METHODS: Thirteen RDTs detecting either the Plasmodium falciparum histidine rich protein 2 (HRP2) or the plasmodial lactate dehydrogenase (pLDH) antigens were selected from the best performing RDTs according to the WHO-FIND product testing programme. The analytical sensitivity of these products was evaluated using a range of reference materials including P. falciparum and Plasmodium vivax whole parasite samples as well as recombinant proteins. RESULTS: The best performing HRP2-based RDTs could detect all P. falciparum cultured samples at concentrations as low as 0.8 ng/mL of HRP2. The limit of detection of the best performing pLDH-based RDT specifically detecting P. vivax was 25 ng/mL of pLDH. CONCLUSION: The analytical sensitivity of P. vivax and Pan pLDH-based RDTs appears to vary considerably from product to product, and improvement of the limit-of-detection for P. vivax detecting RDTs is needed to match the performance of HRP2 and Pf pLDH-based RDTs for P. falciparum. Different assays using different reference materials produce different values for antigen concentration in a given specimen, highlighting the need to establish universal reference assays.


Subject(s)
Chromatography, Affinity/methods , Diagnostic Tests, Routine/methods , Malaria/diagnosis , Plasmodium vivax/isolation & purification , Adult , Antigens, Protozoan/analysis , Humans , Malaria, Falciparum , Malaria, Vivax , Plasmodium falciparum/immunology , Plasmodium falciparum/isolation & purification , Plasmodium vivax/immunology , Sensitivity and Specificity , Time Factors
5.
Anal Chem ; 88(23): 11774-11782, 2016 12 06.
Article in English | MEDLINE | ID: mdl-27750420

ABSTRACT

There is an increasing need for highly sensitive and quantitative diagnostics at the point-of-care. The lateral flow immunoassay (LFA) is one of the most widely used point-of-care diagnostic tests; however, LFAs generally suffer from low sensitivity and lack of quantification. To overcome these limitations, thermal contrast amplification (TCA) is a new method that is based on the laser excitation of gold nanoparticles (GNPs), the most commonly used visual signature, to evoke a thermal signature. To facilitate the clinical translation of the TCA technology, we present the development of a TCA reader, a platform technology that significantly improves the limit of detection and provides quantification of disease antigens in LFAs. This TCA reader provides enhanced sensitivity over visual detection by the human eye or by a colorimetric reader (e.g., BD Veritor System Reader). More specifically, the TCA reader demonstrated up to an 8-fold enhanced analytical sensitivity and quantification among LFAs for influenza, malaria, and Clostridium difficile. Systematic characterization of the laser, infrared camera, and other components of the reader and their integration into a working reader instrument are described. The development of the TCA reader enables simple, highly sensitive quantification of LFAs at the point-of-care.


Subject(s)
Clostridioides difficile/isolation & purification , Immunoassay/methods , Influenza, Human/diagnosis , Malaria/diagnosis , Point-of-Care Testing , Temperature , Gold/chemistry , Humans , Metal Nanoparticles/chemistry
6.
Malar J ; 14: 115, 2015 Mar 18.
Article in English | MEDLINE | ID: mdl-25889624

ABSTRACT

BACKGROUND: Malaria rapid diagnostic tests (RDTs) are appropriate for case management, but persistent antigenaemia is a concern for HRP2-detecting RDTs in endemic areas. It has been suggested that pan-pLDH test bands on combination RDTs could be used to distinguish persistent antigenaemia from active Plasmodium falciparum infection, however this assumes all active infections produce positive results on both bands of RDTs, an assertion that has not been demonstrated. METHODS: In this study, data generated during the WHO-FIND product testing programme for malaria RDTs was reviewed to investigate the reactivity of individual test bands against P. falciparum in 18 combination RDTs. Each product was tested against multiple wild-type P. falciparum only samples. Antigen levels were measured by quantitative ELISA for HRP2, pLDH and aldolase. RESULTS: When tested against P. falciparum samples at 200 parasites/µL, 92% of RDTs were positive; 57% of these on both the P. falciparum and pan bands, while 43% were positive on the P. falciparum band only. There was a relationship between antigen concentration and band positivity; ≥4 ng/mL of HRP2 produced positive results in more than 95% of P. falciparum bands, while ≥45 ng/mL of pLDH was required for at least 90% of pan bands to be positive. CONCLUSIONS: In active P. falciparum infections it is common for combination RDTs to return a positive HRP2 band combined with a negative pan-pLDH band, and when both bands are positive, often the pan band is faint. Thus active infections could be missed if the presence of a HRP2 band in the absence of a pan band is interpreted as being caused solely by persistent antigenaemia.


Subject(s)
Antigens, Protozoan/blood , Diagnostic Tests, Routine/methods , Malaria, Falciparum/diagnosis , Plasmodium falciparum/isolation & purification , Diagnostic Tests, Routine/standards
7.
J Biol Chem ; 283(45): 30980-9, 2008 Nov 07.
Article in English | MEDLINE | ID: mdl-18768477

ABSTRACT

Calcium-dependent protein kinases (CDPKs) of Apicomplexan parasites are crucial for the survival of the parasite throughout its life cycle. CDPK1 is expressed in the asexual blood stages of the parasite, particularly late stage schizonts. We have identified two substrates of Plasmodium falciparum CDPK1: myosin A tail domain-interacting protein (MTIP) and glideosome-associated protein 45 (GAP45), both of which are components of the motor complex that generates the force required by the parasite to actively invade host cells. Indirect immunofluorescence shows that CDPK1 localizes to the periphery of P. falciparum merozoites and is therefore suitably located to act on MTIP and GAP45 at the inner membrane complex. A proportion of both GAP45 and MTIP is phosphorylated in schizonts, and we demonstrate that both proteins can be efficiently phosphorylated by CDPK1 in vitro. A primary phosphorylation of MTIP occurs at serine 47, whereas GAP45 is phosphorylated at two sites, one of which could also be detected in phosphopeptides purified from parasite lysates. Both CDPK1 activity and host cell invasion can be inhibited by the kinase inhibitor K252a, suggesting that CDPK1 is a suitable target for antimalarial drug development.


Subject(s)
Cytoskeletal Proteins/metabolism , Malaria, Falciparum/enzymology , Membrane Proteins/metabolism , Plasmodium falciparum/enzymology , Protein Kinases/metabolism , Protozoan Proteins/metabolism , Animals , Antimalarials/pharmacology , Antimalarials/therapeutic use , Carbazoles/pharmacology , Carbazoles/therapeutic use , Cytoskeletal Proteins/genetics , Enzyme Inhibitors/pharmacology , Enzyme Inhibitors/therapeutic use , Indole Alkaloids/pharmacology , Indole Alkaloids/therapeutic use , Malaria, Falciparum/drug therapy , Malaria, Falciparum/genetics , Membrane Proteins/genetics , Phosphorylation/drug effects , Plasmodium falciparum/genetics , Protein Kinases/genetics , Protozoan Proteins/antagonists & inhibitors , Protozoan Proteins/genetics
SELECTION OF CITATIONS
SEARCH DETAIL
...