Bioanalysis ; 15(15): 905-914, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37354101

ABSTRACT

Background: Workplace drug testing primarily relies on urine analysis, targeting multiple compounds with varying physicochemical characteristics. Biocompatible solid-phase microextraction (BioSPME) is a miniaturized solid-phase extraction technique that enables the simultaneous extraction and preconcentration of analytes directly from the biological matrix. Methods: The BioSPME procedure consisted of the sequential extraction of 50-µl urine samples using LC Tips C18 in basic and acidic pH, followed by desorption with methanol and n-hexane, respectively. The extracts were analyzed by ultra-performance LC-MS/MS. Results: Intra-day precision was 1.2-8.6% and inter-day precision was 1.8-14.2%. Accuracy was 96.8-107.4%. The extraction yields were 62.8-109.4%. The matrix effects were -3.98% to 1%. Conclusion: BioSPME shows promise as an alternative method for preparing urine samples prior to drug measurement by ultra-performance LC-MS/MS.


Subject(s)
Cocaine , Dronabinol , Chromatography, Liquid/methods , Cocaine/analysis , Analgesics, Opioid , Tandem Mass Spectrometry/methods , Solid Phase Extraction , Amphetamines/analysis , Chromatography, High Pressure Liquid/methods