Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 17 de 17
Filter
1.
J Cereb Blood Flow Metab ; : 271678X241237733, 2024 Mar 14.
Article in English | MEDLINE | ID: mdl-38483125

ABSTRACT

Arterial spin labeling (ASL) is a non-invasive magnetic resonance imaging (MRI) method for the assessment of cerebral blood flow (CBF). This review summarizes recent ASL-based investigations in adult and pediatric patients with migraine with aura, migraine without aura, and chronic migraine. A systematic search according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines was conducted within PubMed and reference sections of articles identified from April 2014 to November 2022. Out of 236 initial articles, 20 remained after filtering, encompassing data from 1155 subjects in total. Cross-sectional studies in adults showed inconsistent results, while longitudinal studies demonstrated that cerebral perfusion changes over the migraine cycle can be tracked using ASL. The most consistent findings were observed in ictal states among pediatric migraine patients, where studies showed hypoperfusion matching aura symptoms during early imaging followed by hyperperfusion. Overall, ASL is a useful but currently underutilized modality for evaluating cerebral perfusion in patients with migraine. The generalizability of results is currently limited by heterogeneities regarding study design and documentation of clinical variables (e.g., relation of attacks to scanning timepoint, migraine subtypes). Future MRI studies should consider augmenting imaging protocols with ASL to further elucidate perfusion dynamics in migraine.

2.
Rofo ; 196(1): 36-51, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37467779

ABSTRACT

BACKGROUND: Arterial spin labeling (ASL) is a magnetic resonance imaging (MRI)-based technique using labeled blood-water of the brain-feeding arteries as an endogenous tracer to derive information about brain perfusion. It enables the assessment of cerebral blood flow (CBF). METHOD: This review aims to provide a methodological and technical overview of ASL techniques, and to give examples of clinical use cases for various diseases affecting the central nervous system (CNS). There is a special focus on recent developments including super-selective ASL (ssASL) and time-resolved ASL-based magnetic resonance angiography (MRA) and on diseases commonly not leading to characteristic alterations on conventional structural MRI (e. g., concussion or migraine). RESULTS: ASL-derived CBF may represent a clinically relevant parameter in various pathologies such as cerebrovascular diseases, neoplasms, or neurodegenerative diseases. Furthermore, ASL has also been used to investigate CBF in mild traumatic brain injury or migraine, potentially leading to the establishment of imaging-based biomarkers. Recent advances made possible the acquisition of ssASL by selective labeling of single brain-feeding arteries, enabling spatial perfusion territory mapping dependent on blood flow of a specific preselected artery. Furthermore, ASL-based MRA has been introduced, providing time-resolved delineation of single intracranial vessels. CONCLUSION: Perfusion imaging by ASL has shown promise in various diseases of the CNS. Given that ASL does not require intravenous administration of a gadolinium-based contrast agent, it may be of particular interest for investigations in pediatric cohorts, patients with impaired kidney function, patients with relevant allergies, or patients that undergo serial MRI for clinical indications such as disease monitoring. KEY POINTS: · ASL is an MRI technique that uses labeled blood-water as an endogenous tracer for brain perfusion imaging.. · It allows the assessment of CBF without the need for administration of a gadolinium-based contrast agent.. · CBF quantification by ASL has been used in several pathologies including brain tumors or neurodegenerative diseases.. · Vessel-selective ASL methods can provide brain perfusion territory mapping in cerebrovascular diseases.. · ASL may be of particular interest in patient cohorts with caveats concerning gadolinium administration..


Subject(s)
Cerebrovascular Disorders , Migraine Disorders , Neurodegenerative Diseases , Humans , Child , Contrast Media , Spin Labels , Gadolinium , Magnetic Resonance Imaging/methods , Arteries , Magnetic Resonance Angiography/methods , Cerebrovascular Disorders/diagnostic imaging , Water
3.
Cephalalgia ; 43(2): 3331024221128278, 2023 02.
Article in English | MEDLINE | ID: mdl-36751858

ABSTRACT

BACKGROUND: Migraine is a highly prevalent primary headache disorder. Despite a high burden of disease, key disease mechanisms are not entirely understood. Functional magnetic resonance imaging is an imaging method using the blood-oxygen-level-dependent signal, which has been increasingly used in migraine research over recent years. This systematic review summarizes recent findings employing functional magnetic resonance imaging for the investigation of migraine. METHODS: We conducted a systematic search and selection of functional magnetic resonance imaging applications in migraine from April 2014 to December 2021 (PubMed and references of identified articles according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines). Methodological details and main findings were extracted and synthesized. RESULTS: Out of 224 articles identified, 114 were included after selection. Repeatedly emerging structures of interest included the insula, brainstem, limbic system, hypothalamus, thalamus, and functional networks. Assessment of functional brain changes in response to treatment is emerging, and machine learning has been used to investigate potential functional magnetic resonance imaging-based markers of migraine. CONCLUSIONS: A wide variety of functional magnetic resonance imaging-based metrics were found altered across the brain for heterogeneous migraine cohorts, partially correlating with clinical parameters and supporting the concept to conceive migraine as a brain state. However, a majority of findings from previous studies have not been replicated, and studies varied considerably regarding image acquisition and analyses techniques. Thus, while functional magnetic resonance imaging appears to have the potential to advance our understanding of migraine pathophysiology, replication of findings in large representative datasets and precise, standardized reporting of clinical data would likely benefit the field and further increase the value of observations.


Subject(s)
Migraine Disorders , Humans , Brain , Magnetic Resonance Imaging/methods , Brain Mapping/methods , Hypothalamus
5.
BMC Med Imaging ; 20(1): 94, 2020 08 07.
Article in English | MEDLINE | ID: mdl-32767967

ABSTRACT

BACKGROUND: To analyse the influence of whole body (wb)-MRI on patient management compared to routine diagnostic tests in patients with fever of unknown origin (FUO). METHODS: Twenty-four patients with FUO, defined as illness of more than three weeks with fever greater than 38.3 °C, underwent wb-MRI at a 1.5 T MR-system. The MR-protocol consisted of the following sequences: axial T1 VIBE, coronal T2-TIRM and a coronal echoplanar diffusion weighted sequence (overall acquisition time 29:39 min:s). Furthermore, laboratory findings, chest-x-ray, abdominal ultrasound, CT-scans and/or PET-CT scans were evaluated and compared to the wb-MRI findings in regard to treatment changes. RESULTS: Wb-MRI yielded a correct diagnosis in 70% of the patients. In 46% the inflammatory focus was exclusively detected by wb-MRI. Focus detection by wb-MRI led to a subsequent change of the clinical management in 92% of the patients. In 6 patients both a wb-MRI and a PET-CT were performed yielding the correct diagnosis in the same 4 of 6 patients for both imaging modalities. CONCLUSIONS: Wb-MRI appears to be of value in the evaluation of FUO patients, allowing for optimized treatment by increasing diagnostic certainty. Due to its lack of nephrotoxicity and ionizing radiation it may be preferred over standard imaging techniques and PET-CT in the future. However, given the low number of patients in our trial, further prospective studies have to be performed to confirm our results.


Subject(s)
Diagnostic Tests, Routine/methods , Fever of Unknown Origin/diagnostic imaging , Magnetic Resonance Imaging/methods , Whole Body Imaging/methods , Adolescent , Adult , Aged , Aged, 80 and over , Child , Feasibility Studies , Female , Humans , Male , Middle Aged , Positron Emission Tomography Computed Tomography , Radiography, Thoracic , Retrospective Studies , Sensitivity and Specificity , Tomography, X-Ray Computed , Ultrasonography , Young Adult
6.
Eur J Orthop Surg Traumatol ; 29(3): 659-666, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30310989

ABSTRACT

PURPOSE: To evaluate the usefulness of a novel MRI sequence strategy in the assessment of the periprosthetic anatomical structures after primary total knee arthroplasty. METHODS: Two MR sequences were retrospectively compared for the imaging of 15 patients with implanted cruciate-retaining/fixed-bearing TKAs (DePuy, PFC Sigma): a slice encoding sequence for metal artifact correction (SEMAC) and a standard sequence. Images were acquired on a 1.5-T system. The degree of artifact reduction was assessed using several qualitative (Likert-type scale) (artifact size, distorsion, blur, image quality, periprosthetic bone, posterior cruciate ligament, lateral collateral ligament, medial collateral ligament, patella tendon, popliteal vessels) and quantitative (artifact volume, Insall-Salvati index, length of patella/tendon, prosthesis dimensions) parameters by blinded reads performed by four investigators. The SEMAC sequences were statistically compared with the standard sequence using Wilcoxon test. Additionally, the intraclass correlation coefficient (ICC) for interobserver agreement was calculated. RESULTS: Higher levels of blurring were found with SEMAC compared to standard sequences (p < 0.001). All other qualitative parameters improved significantly with the application of SEMAC. In comparison with conventional sequences, the artifact volume was reduced by 59% utilizing SEMAC. Thus, the artifact reduction improved the precision of measurements such as Insall-Salvati index and length of patella/tendon (p < 0.001). The dimension of the tibial component (Ti alloy/polyethylene) revealed accurate values with both MRI sequences. A sufficient interobserver agreement among all readers was found with SEMAC, qualitatively ICC 0.9 (range 0.8-1) as well as quantitatively ICC 0.95 (range 0.92-0.98). CONCLUSIONS: SEMAC effectively reduces artifacts caused by metallic implants after total knee arthroplasty relative to standard imaging. This allows for an improved assessment of periprosthetic anatomical structures. This might enable an improved detectability of postoperative complications in the future. LEVEL OF EVIDENCE: Diagnostic Study Level III.


Subject(s)
Arthroplasty, Replacement, Knee/adverse effects , Artifacts , Knee Joint/diagnostic imaging , Magnetic Resonance Imaging/methods , Aged , Aged, 80 and over , Female , Humans , Knee Prosthesis , Male , Metals , Middle Aged , Retrospective Studies
7.
Anticancer Res ; 38(2): 969-978, 2018 02.
Article in English | MEDLINE | ID: mdl-29374729

ABSTRACT

AIM: The purpose of this IRB-approved, retrospective study was to compare image quality between 2D and high-resolution 3D, T2-weighted (T2WI) magnetic resonance imaging (MRI) sequences and to investigate the additional value of ultra-high b-value diffusion-weighted imaging (DWI; b=2,000 mm/s2) for both rectal cancer staging and evaluating treatment response. MATERIALS AND METHODS: From 12 February to 24 August 2016, 26 consecutive patients (22 males, four females; mean age: 61.9±14.0 years) with histologically-proven rectal cancer. In total 31 examinations [12 prior to and 19 after chemoradiation (CRT)] were included. The patients underwent pelvic MRI on a 3.0-T scanner (Magnetom Skyra, Erlangen, Germany). Three radiologists (3, 4, and 5 years of experience in MRI, respectively) independently assessed all images and rated the image quality of DWI (b=800 mm/s2), apparent diffusion coefficient map, DWI (b=2,000 mm/s2), 3D sagittal T2WI, 3D axial T2WI, 2D sagittal T2WI, and 2D axial T2WI of each patient, respectively. In addition, signal intensity ratios (SIR) were calculated between rectal cancer and obturator internus muscle (background) in all patients after CRT on DWI (b=2,000 mm/s2) and correlated with histopathological regression grade (RG). RESULTS: Tumor delineation was significantly better by 2D T2WI than 3D T2WI both before and after CRT (before CRT: Z=-3.2, p=0.02; after CRT: Z=-4.408, p<0.001; all: Z=-5.192; p<0.001) and was the preferred method, although image quality ratings were not significantly different (3D sagittal: 4.00±0.48; 2D sagittal: 4.03±0.34, p=0.713; 3D axial: 3.85±0.61, 2D axial: 3.78±0.64, p=0.537). Independent t-test showed significantly higher SIR between those with RG 1 or 2 (moderate response: mean score=2.02) and those with RG 3+4 (good response: mean score=0.8) (t=3.044, p=0.011). In those with RG 4 (complete response), SIR of b2000 was 0.946 compared to a 1.41 average of the whole cohort. In two patients, tumor was invisible on b2000 following CRT (RG 3 and 4, respectively). Interobserver agreement was mostly good (κ≥0.6) regarding image quality assessment, except for poor agreement (κ=0.4) in DWI (b2000) between the two less-experienced readers. CONCLUSION: In conclusion, 3D T2WI might be useful for evaluating response to neoadjuvant therapy in a comprehensive, cost-effective protocol, where 2D imaging seems to be preferable. In addition, DWI (b2000) may be beneficial in assessing both the primary and the residual tumor after CRT in rectal cancer and SIR may be helpful in assessing response to CRT.


Subject(s)
Adenocarcinoma/pathology , Diffusion Magnetic Resonance Imaging/methods , Image Interpretation, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Quality Assurance, Health Care , Rectal Neoplasms/pathology , Adenocarcinoma/therapy , Adult , Aged , Aged, 80 and over , Chemoradiotherapy, Adjuvant , Female , Follow-Up Studies , Humans , Male , Middle Aged , Observer Variation , Rectal Neoplasms/therapy , Retrospective Studies , Treatment Outcome
8.
J Comput Assist Tomogr ; 41(1): 121-124, 2017 Jan.
Article in English | MEDLINE | ID: mdl-27680413

ABSTRACT

OBJECTIVE: The aims were to study the acromion parameters in the population and to assess the extremity or sex variation in the acromion morphology. METHODS: The lateral acromion angle (LAA) and the acromion index (AI) were assessed in a computed tomographic scan database of 250 individuals in the age group of 20 to 49 years. For the analysis of LAA and AI, 286 and 234 shoulders were available, respectively. RESULTS: The LAA was 73.6 ± 6.6 degrees; 73.7 ± 6.9 and 72.5 ± 6.1 degrees for the right and left shoulder, respectively. The AI was 0.755 ± 0.12; 0.82 ± 0.12 and 0.69 ± 0.12 for the left and the right shoulder, respectively. The AI of the right shoulder was significantly different between the 2 sexes (P = 0.04). The difference in the AI and the LAA of the right and left shoulders was significant (P < 0.0001, P = 0.04). CONCLUSIONS: The morphology of the acromion differs between the right and the left shoulders as well as between sexes.


Subject(s)
Acromion/anatomy & histology , Acromion/diagnostic imaging , Tomography, X-Ray Computed/statistics & numerical data , Adult , Female , Germany/epidemiology , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Sex Distribution , Sex Factors
9.
Anticancer Res ; 36(8): 4353-8, 2016 Aug.
Article in English | MEDLINE | ID: mdl-27466556

ABSTRACT

AIM: To perform a quantitative, volumetric analysis of therapeutic effects of trans-arterial chemoembolization (TACE) in hepatocellular carcinoma (HCC) patients. PATIENTS AND METHODS: Entire tumor volume and a subset of hypervascular tumor portions were analyzed pre- and post-TACE in magnetic resonance imaging datasets of 22 HCC patients using a semi-automated segmentation and evaluation tool from the Medical Imaging Interaction Toolkit. Results were compared to mRECIST measurements and inter-reader variability was assessed. RESULTS: Mean total tumor volume increased statistical significantly after TACE (84.6 ml pre- vs. 97.1 ml post-TACE, p=0.03) while hypervascular tumor volume decreased from 9.1 ml pre- to 3.7 ml post-TACE (p=0.0001). Likewise, mRECIST diameters decreased significantly after therapy (44.2 vs. 15.4 mm). In the inter-reader assessment, overlap errors were 12.3-17.7% for entire and 36.3-64.2% for the enhancing tumor volume. CONCLUSION: Quantification of therapeutic changes after TACE therapy is feasible using a semi-automated segmentation and evaluation tool. Following TACE, hypervascular tumor volume decreases significantly.


Subject(s)
Carcinoma, Hepatocellular/therapy , Chemoembolization, Therapeutic , Liver Neoplasms/therapy , Magnetic Resonance Imaging , Aged , Aged, 80 and over , Carcinoma, Hepatocellular/diagnostic imaging , Carcinoma, Hepatocellular/pathology , Female , Humans , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/pathology , Male , Middle Aged , Treatment Outcome , Tumor Burden
10.
In Vivo ; 29(1): 123-7, 2015.
Article in English | MEDLINE | ID: mdl-25600540

ABSTRACT

AIM: Patients with acute alcohol intoxication present a serious and still growing problem for pre- and intra-hospital emergency services. Data on the clinical risk assessment of alcohol-intoxicated patients are sparse. The aim of the present work was, therefore, to collect and assess relevant risk parameters. MATERIALS AND METHODS: At the Mannheim University Hospital, the medical records of 844 alcohol-intoxicated Emergency Department patients were retrospectively studied and evaluated. RESULTS: The patients with alcohol intoxications were predominantly males with an average age of 45 years. Mean blood alcohol concentration was 0.28%. The rate of haemodynamic, respiratory or metabolic complications in these patients was low. In 43% of cases, there was moderately to severely impaired consciousness. About half of the patients were treated on an outpatient basis. CONCLUSION: Our data demonstrate a low clinical risk for alcohol-intoxicated patients. Nevertheless, it is necessary to provide a defined monitoring standard in order to also be prepared for the few potential complications of alcohol intoxication and the possible differential diagnoses of impaired consciousness.


Subject(s)
Alcoholic Intoxication/diagnosis , Alcoholic Intoxication/epidemiology , Acute Disease , Adolescent , Adult , Aged , Aged, 80 and over , Alcoholic Intoxication/therapy , Disease Management , Female , Glasgow Coma Scale , Humans , Male , Middle Aged , Risk Assessment , Young Adult
11.
ScientificWorldJournal ; 2013: 348105, 2013.
Article in English | MEDLINE | ID: mdl-24319359

ABSTRACT

PURPOSE: To evaluate diffusion-weighted MR imaging (DWI-MRI) for the detection and assessment of infectious renal disease. MATERIALS AND METHODS: Twenty-one patients with suspicious increased signal intensity of the kidneys on DWI sequences and corresponding ADC decrease were identified. Sixty patients without clinical signs of renal infection served as a control group. All patients were examined with the following sequences: EPI-DWI (0/400/800 s/mm(2)), T2w HASTE, and T1w VIBE after intravenous injection of Gd-chelate. Confirmation of renal infection was established on the basis of clinical criteria. T1w and T2w images were assessed and compared to DWI for the presence of altered signal, and the degree of the visibility of pathology was graded on an ordinal three-point scale. RESULTS: In all 21 patients with positive DWI findings a renal infection could be confirmed. T2w imaging and contrast-enhanced T1w imaging displayed obvious pathologic signal in 3/21 (14%) and 11/19 (58%) patients and slightly pathologic signal in 17/21 (81%) and 7/19 (37%), respectively. The median visibility score of 2 for the DWI and the T1w images was significantly higher than the score of 1 for the T2w imaging, P = 0.0001 (DWI versus T2w) and P = 0.078 (T1w versus T2w). CONCLUSION: DWI of the kidneys seems to be highly sensitive for the detection of infections within the kidney.


Subject(s)
Diffusion Magnetic Resonance Imaging/methods , Echo-Planar Imaging/methods , Gadolinium , Kidney/pathology , Nephritis/diagnosis , Adolescent , Adult , Aged , Aged, 80 and over , Child , Contrast Media , Female , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Young Adult
12.
Invest Radiol ; 48(1): 55-60, 2013 Jan.
Article in English | MEDLINE | ID: mdl-23192164

ABSTRACT

PURPOSE: The aim of this study was to compare the detection of brain metastases at 3 T using a 32-channel head coil with 2 different 3-dimensional (3D) contrast-enhanced sequences, a T1-weighted fast spin-echo-based (SPACE; sampling perfection with application-optimized contrasts using different flip angle evolutions) sequence and a conventional magnetization-prepared rapid gradient-echo (MP-RAGE) sequence. MATERIALS AND METHODS: Seventeen patients with 161 brain metastases were examined prospectively using both SPACE and MP-RAGE sequences on a 3-T magnetic resonance system. Eight healthy volunteers were similarly examined for determination of signal-to-noise ratio (SNR) values. Parameters were adjusted to equalize acquisition times between the sequences (3 minutes and 30 seconds). The order in which sequences were performed was randomized. Two blinded board-certified neuroradiologists evaluated the number of detectable metastatic lesions with each sequence relative to a criterion standard reading conducted at the Gamma Knife facility by a neuroradiologist with access to all clinical and imaging data. RESULTS: In the volunteer assessment with SPACE and MP-RAGE, SNR (10.3 ± 0.8 vs 7.7 ± 0.7) and contrast-to-noise ratio (0.8 ± 0.2 vs 0.5 ± 0.1) were statistically significantly greater with the SPACE sequence (P < 0.05). Overall, lesion detection was markedly improved with the SPACE sequence (99.1% of lesions for reader 1 and 96.3% of lesions for reader 2) compared with the MP-RAGE sequence (73.6% of lesions for reader 1 and 68.5% of lesions for reader 2; P < 0.01). CONCLUSIONS: A 3D T1-weighted fast spin echo sequence (SPACE) improves detection of metastatic lesions relative to 3D T1-weighted gradient-echo-based scan (MP-RAGE) imaging when implemented with a 32-channel head coil at identical scan acquisition times (3 minutes and 30 seconds).


Subject(s)
Brain Neoplasms/diagnosis , Brain Neoplasms/secondary , Contrast Media , Imaging, Three-Dimensional , Magnetic Resonance Imaging/methods , Humans , Magnetic Resonance Imaging/instrumentation , Middle Aged , Signal-To-Noise Ratio
13.
Eur J Radiol ; 81(1): 132-8, 2012 Jan.
Article in English | MEDLINE | ID: mdl-20621430

ABSTRACT

OBJECTIVE: To prospectively compare test bolus and bolus tracking for the determination of scan delay of pulmonary dual-energy CT angiography in patients with suspected pulmonary embolism. MATERIALS AND METHODS: 60 consecutive patients referred for CTA for exclusion of PE were randomized either into a test bolus group or into a bolus tracking group. All exams were performed on a 64-channel dual source CT scanner. A standard single-acquisition dual-energy CTA was performed after injection of 100ml Iomeprol 400 followed by a saline chaser of 4 ml/s. The scan delay was determined using either test bolus (n=30) or bolus tracking (n=30). Test bolus was performed using an additional 20 ml Iomeprol 400 injected with a rate of 4 ml/s during acquisition of a series of dynamic low-dose monitoring scans followed by injection of a saline bolus of 20 ml using the same flow rate. For DECT angiography of the lungs 100ml Iomeprol 400 was injected with an injection rate of 4 ml/s followed by a saline chaser of 20 ml using the same flow rate. Attenuation profiles of different vascular segments (pulmonary arteries, pulmonary parenchyma, aorta, all 4 heart chambers) were measured to evaluate the timing techniques. Overall image quality of dual-energy "perfusion" maps and virtual 120 kV CTA images was evaluated by two radiologists regarding the present of artifacts. RESULTS: In all patients an adequate and homogeneous contrast enhancement of more than 400 Hounsfield units (HU) was achieved in the different vascular districts. No statistically significant difference between test bolus and bolus tracking was found regarding vessel attenuation or overall image quality. CONCLUSION: A homogeneous opacification of the different vascular territories and the pulmonary parenchyma as well as a sufficient image quality can be achieved with either bolus tracking or test bolus techniques.


Subject(s)
Iopamidol/analogs & derivatives , Models, Biological , Pulmonary Embolism/diagnostic imaging , Pulmonary Embolism/metabolism , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Algorithms , Computer Simulation , Contrast Media/pharmacokinetics , Female , Humans , Iopamidol/pharmacokinetics , Lung/diagnostic imaging , Lung/metabolism , Male , Metabolic Clearance Rate , Middle Aged , Radiographic Image Enhancement/methods , Reproducibility of Results , Sensitivity and Specificity
14.
Eur J Radiol ; 81(12): 3691-6, 2012 Dec.
Article in English | MEDLINE | ID: mdl-21163600

ABSTRACT

PURPOSE: To investigate the dose reduction potential of low kV triple-rule-out dual-source CT angiography (TRO-CTA) in non-obese (BMI ≤ 25 kg/m(2)) patients with acute chest pain. MATERIALS AND METHODS: Sixty consecutive patients were randomly assigned to two different retrospectively ECG-gated TRO-CTA protocols in this prospective trial: Thirty patients were examined with a 120-kV standard protocol (320 reference mAs with automatic tube current modulation, automatically adapted pitch and ECG-pulsing) and served as the control group (group 1), an otherwise identical 100 kV protocol was used in the other thirty patients (group 2) for a radiation dose reduction. Subjective image quality was assessed on a 5 point scale (1: excellent, 5: non-diagnostic) by two blinded observers. Quantitative image analysis assessed vascular attenuation, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in different vascular segments. The effective dose was calculated from the dose length product (DLP) using a conversion coefficient of 0.017 mSvmGy(-1)cm(-1). RESULTS: There was no significant difference of age, BMI, heart rate, pitch or scan length between both patient groups. Subjective image quality was rated similar in both groups (group 1: 1.2 ± 0.4, group 2: average score=1.3 ± 0.5). Vessel attenuation was significantly higher in group 2 than in group 1 (ascending aorta: 456 ± 83 HU vs. 370 ± 78 HU, p<0.001; pulmonary artery: 468 ± 118 HU vs. 411 ± 91 HU, p=0.03; left coronary artery: 437 ± 110 HU vs. 348 ± 89 HU, p<0.001), however, there was no significant difference in SNR (13.2 ± 7.6 vs. 14.5 ± 7.5, p=0.49) or CNR (13.8 ± 6.6 vs. 15.9 ± 7.7, p=0.25). The effective radiation dose of the 100 kV protocol was significantly lower (9.6 ± 3.2 mSv vs. 18.1 ± 9.4 mSv, p<0.0001). CONCLUSION: TRO-CTA with 100 kV is feasible in non-obese patients and results in diagnostic image quality and significantly reduced radiation dose.


Subject(s)
Angiography/methods , Cardiac-Gated Imaging Techniques/methods , Chest Pain/diagnostic imaging , Radiation Protection/methods , Radiography, Thoracic/methods , Tomography, X-Ray Computed/methods , Acute Disease , Adult , Aged , Aged, 80 and over , Humans , Middle Aged , Radiation Dosage , Reproducibility of Results , Sensitivity and Specificity
15.
Eur J Radiol ; 80(1): 50-3, 2011 Oct.
Article in English | MEDLINE | ID: mdl-21497470

ABSTRACT

PURPOSE: To assess the additional diagnostic value of indirect CT venography (CTV) of the pelvis and upper thighs performed after pulmonary CT angiography (CTA) for the diagnosis of venous thromboembolism (VTE). MATERIALS AND METHODS: In a retrospective analysis, the radiology information system entries between January 2003 and December 2007 were searched for patients who received pulmonary CTA and additional CTV of the pelvis and upper thighs. Of those patients, the radiology reports were reviewed for the diagnosis of pulmonary embolism (PE) and deep venous thrombosis (DVT) in the pelvic veins and veins of the upper thighs. In cases with an isolated pelvic thrombosis at CTV (i.e. which only had a thrombosis in the pelvic veins but not in the veins of the upper thigh) ultrasound reports were reviewed for the presence of DVT of the legs. The estimated radiation dose was calculated for pulmonary CTA and for CTV of the pelvis. RESULTS: In the defined period 3670 patients were referred to our institution for exclusion of PE. Of those, 642 patients (353 men, 289 women; mean age, 65±15 years, age range 18-98 years) underwent combined pulmonary CTA and CTV. Among them, PE was found in 227 patients (35.4%). In patients without PE CTV was negative in all cases. In patients with PE, CTV demonstrated pelvic thrombosis in 24 patients (3.7%) and thrombosis of the upper thighs in 43 patients (6.6%). Of those patients 14 (2.1%) had DVT in the pelvis and upper thighs. In 10 patients (1.5%) CTV showed an isolated pelvic thrombosis. Of those patients ultrasound reports were available in 7 patients, which revealed DVT of the leg veins in 5 cases (1%). Thus, the estimated prevalence of isolated pelvic thrombosis detected only by pelvic CTV ranges between 1-5/642 patients (0.1-0.7%). Radiation dose ranges between 4.8 and 9.7 mSv for additional CTV of the pelvis. CONCLUSION: CTV of the pelvis performed after pulmonary CTA is of neglectable additional diagnostic value for the detection of VTE, because the additional radiation dose is high and isolated pelvic DVT is very rare. Venous imaging of the legs (preferably by radiation-free ultrasound) is sufficient for the diagnosis of underlying DVT in patients with suspected PE.


Subject(s)
Pelvis/diagnostic imaging , Phlebography , Pulmonary Embolism/diagnostic imaging , Radiation Dosage , Tomography, X-Ray Computed , Venous Thromboembolism/diagnostic imaging , Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Pulmonary Artery/diagnostic imaging , Young Adult
16.
Invest Radiol ; 45(6): 341-6, 2010 Jun.
Article in English | MEDLINE | ID: mdl-20421798

ABSTRACT

OBJECTIVES: To evaluate a software algorithm highlighting vascular iodine distribution in dual energy (DE) computed tomography angiography (CTA) for the diagnosis of pulmonary embolism (PE). MATERIAL AND METHODS: Pulmonary DE-CTA of 16 patients with PE and 16 patients without PE were analyzed using a software algorithm highlighting vascular iodine distribution. The algorithm color-codes lung vessels depending on their local iodine distribution on a 2-color scale. The diagnostic performance of the software for the detection of PE was assessed on patient and segmental basis by consensus reading of 2 blinded radiologists. The reading of the standard CTA data by an independent third radiologist and clinical follow-up served as the standard of reference for the diagnosis of PE. RESULTS: Of 576 analyzed segments CTA revealed 88 diseased lung segments with 1 or more emboli. The software correctly highlighted 62 segments as positive. Twenty-six segments with PE were not highlighted. Seventy-five segments were highlighted false positive. All 16 patients with PE were identified as positive, but 1 of these patients had no true positive finding on a segmental basis and was therefore classified as false negative. Twenty-three segments in 8 patients without PE were highlighted as positive. Sensitivity, specificity, positive predictive value, and negative predictive value of the software algorithm were 93.8%, 50%, 65.2%, 88.9% per patient and 70.5%, 84.6%, 45.3%, 94.1% per segment, respectively. CONCLUSION: Additional review of the DE-CTA with a dedicated software algorithm highlighting the vascular iodine distribution has a high negative predictive value important for exclusion of segmental PE.


Subject(s)
Algorithms , Angiography/methods , Pulmonary Artery/diagnostic imaging , Pulmonary Embolism/diagnostic imaging , Radiographic Image Interpretation, Computer-Assisted/methods , Radiography, Dual-Energy Scanned Projection/methods , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Radiographic Image Enhancement/methods , Reproducibility of Results , Sensitivity and Specificity
17.
Acad Radiol ; 17(3): 309-15, 2010 Mar.
Article in English | MEDLINE | ID: mdl-20152725

ABSTRACT

RATIONALE AND OBJECTIVES: To retrospectively determine the value of a volumetric ventricle analysis for the assessment of right ventricular dysfunction in patients with suspected pulmonary embolism (PE) by using image data from non-electrocardiographically (ECG)-gated multidetector computed tomography angiography (CTA). MATERIALS AND METHODS: Hypothesizing that the presence of PE and the embolus location correlated with right ventricular dysfunction, we retrospectively analyzed 100 non-ECG-gated pulmonary CTA datasets of patients with central, peripheral, and without PE. Right ventricle/left ventricle (RV/LV) diameter ratio measured in transverse sections (RV/LV(trans)), four-chamber view (RV/LV(4ch)), and RV/LV volume ratio (RV/LV(vol)) were assessed on CT images. The results were correlated with the embolus location, the 30-day mortality rate, and the necessity of intensive care treatment. RESULTS: All CT parameters showed statistically significant differences between all patients groups depended on embolus location. The receiver operating characteristic analysis RV/LV(vol) showed the strongest discriminatory power to differ between patients with central and without PE and between patients with central and peripheral PE (central PE vs. no PE: RV/LV(vol) = 0.932, RV/LV(trans) = 0.880, and RV/LV(4ch) = 0.811, central PE vs. peripheral PE: RV/LV(vol) = 0.950, RV/LV(trans) = 0.849, and RV/LV(4ch) = 0.881), indicating a correlation with embolus location predisposing for RVD. For the identification of high-risk patients with PE all three CT parameters showed statistically significant values (P < .0001), whereas in the receiver operating characteristic analysis, RV/LV(vol) had the strongest discriminatory power (RV/LV(vol) = 0.819, RV/LV(trans) = 0.799, and RV/LV(4ch) = 0.758). CONCLUSION: Ventricle volumetry of non-ECG-gated CTA allows the assessment of right ventricular dysfunction in patients with acute PE. Compared to unidimensional measurements, a volumetric analysis seems to be slightly superior to identify high-risk patients with adverse clinical outcome. However, the method is more time consuming and requires dedicated software tools compared to unidimensional parameters, which is disadvantageous in an emergency setting.


Subject(s)
Angiography/methods , Imaging, Three-Dimensional/methods , Pulmonary Embolism/complications , Pulmonary Embolism/diagnostic imaging , Tomography, X-Ray Computed/methods , Ventricular Dysfunction, Right/diagnostic imaging , Ventricular Dysfunction, Right/etiology , Acute Disease , Cardiac-Gated Imaging Techniques , Female , Humans , Male , Middle Aged , Pulmonary Artery/diagnostic imaging , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...