ABSTRACT
BACKGROUND AND OBJECTIVES: In patients with kidney failure due to IgA nephropathy, IgA deposits can recur in a subsequent kidney transplant. The incidence, effect, and risk factors of IgA nephropathy recurrence is unclear, because most studies have been single center and sample sizes are relatively small. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: We performed a multicenter, international, retrospective study to determine the incidence, risk factors, and treatment response of recurrent IgA nephropathy after kidney transplantation. Data were collected from all consecutive patients with biopsy-proven IgA nephropathy transplanted between 2005 and 2015, across 16 "The Post-Transplant Glomerular Disease" study centers in Europe, North America, and South America. RESULTS: Out of 504 transplant recipients with IgA nephropathy, recurrent IgA deposits were identified by kidney biopsy in 82 patients; cumulative incidence of recurrence was 23% at 15 years (95% confidence interval, 14 to 34). Multivariable Cox regression revealed a higher risk for recurrence of IgA deposits in patients with a pre-emptive kidney transplant (hazard ratio, 3.45; 95% confidence interval, 1.31 to 9.17) and in patients with preformed donor-specific antibodies (hazard ratio, 2.59; 95% confidence interval, 1.09 to 6.19). After kidney transplantation, development of de novo donor-specific antibodies was associated with subsequent higher risk of recurrence of IgA nephropathy (hazard ratio, 6.65; 95% confidence interval, 3.33 to 13.27). Immunosuppressive regimen was not associated with recurrent IgA nephropathy in multivariable analysis, including steroid use. Graft loss was higher in patients with recurrence of IgA nephropathy compared with patients without (hazard ratio, 3.69; 95% confidence interval, 2.04 to 6.66), resulting in 32% (95% confidence interval, 50 to 82) graft loss at 8 years after diagnosis of recurrence. CONCLUSIONS: In our international cohort, cumulative risk of IgA nephropathy recurrence increased after transplant and was associated with a 3.7-fold greater risk of graft loss.
Subject(s)
Antibodies/blood , Glomerulonephritis, IGA/epidemiology , Kidney Failure, Chronic/etiology , Kidney Failure, Chronic/surgery , Adult , Allografts/immunology , Allografts/pathology , Biopsy , Brazil/epidemiology , Europe/epidemiology , Female , Glomerulonephritis, IGA/complications , Glomerulonephritis, IGA/drug therapy , Glomerulonephritis, IGA/pathology , Graft Survival , Humans , Incidence , Kidney/pathology , Kidney Transplantation , Male , Middle Aged , Recurrence , Retrospective Studies , Risk Factors , United States/epidemiologyABSTRACT
PURPOSE: To report the device performance and safety for the Surfacer Inside-Out access catheter system in patients with thoracic central venous obstruction (TCVO) requiring central venous access (CVA). MATERIALS AND METHODS: Five sites prospectively enrolled 30 patients requiring a tunneled dialysis catheter between February 2017 and September 2018 in the SAVE (Surfacer System to Facilitate Access in Venous Obstructions) registry. Patient demographics, medical history, and type of TCVO were documented at enrollment. Device performance and adverse events were collected during the procedure and upon hospital discharge. Twenty-nine of the 30 patients enrolled required CVA for hemodialysis. Retrospective classification of TCVOs according to SIR reporting standards showed 9 patients (30%) had Type 4 obstructions, 8 (26.7%) had Type 3, 5 (16.7%) had Type 2, and 8 (26.7%) had Type 1 obstruction. RESULTS: Central venous catheters (CVCs) were successfully placed in 29 of 30 patients (96.7%). The procedure was discontinued in 1 patient due to vascular anatomical tortuosity. All 29 patients with successful CVC placement achieved adequate catheter patency and tip positioning. There were no device-related adverse events, catheter malposition, or intra- or postprocedural complications. Mean time from device insertion to removal for the 29 patients who successfully completed the procedure was 24 ± 14.9 (range, 6-70) minutes. Mean fluoroscopy time was 6.8 ± 4.5 (range, 2.2-25.5) minutes. CONCLUSIONS: The Surfacer Inside-Out procedure provided an alternative option to restore right-sided CVA in patients with TCVO.