1.
Front Cell Infect Microbiol ; 13: 1266790, 2023.
Article in English | MEDLINE | ID: mdl-37712059

ABSTRACT

The analysis of immunological parameters during the course of a SARS-CoV-2 infection is of great importance, both to identify diagnostic markers for the risk of a severe course of COVID-19, and to better understand the role of the immune system during the infection. By using multicolor flow cytometry we compared the phenotype of Natural Killer (NK) cells from hospitalized COVID-19 patients during early SARS-CoV-2 infection with samples from recovered and SARS-CoV-2 naïve subjects. Unsupervised high-dimensional analysis of 28-color flow cytometric data revealed a strong enrichment of NKG2C expressing NK cells in response to the acute viral infection. In addition, we found an overrepresentation of highly activated NK cell subsets with an exhausted phenotype. Moreover, our data show long-lasting phenotypic changes within the NK cell compartment that did not completely reverse up to 2 months after recovery. This demonstrates that NK cells are involved in the early innate immune response against SARS-CoV-2.


Subject(s)
COVID-19 , Humans , SARS-CoV-2 , Flow Cytometry , Immunity, Innate , Killer Cells, Natural
2.
Eur J Immunol ; 52(5): 810-815, 2022 05.
Article in English | MEDLINE | ID: mdl-35247269

ABSTRACT

Neutralizing antibodies against SARS-CoV-2 are important to protect against infection and/or disease. Using an assay to detect antibodies directed against the receptor binding domain (RBD) of SARS-CoV-2 Spike, we identified individuals with SARS-CoV-2 infection after an outbreak at a local health institution. All but one COVID-19 patient developed detectable anti-RBD antibodies and 77% had virus neutralizing antibody titers of >1:25. Antibody levels declined slightly over time. However, we still detected virus neutralizing antibody titers in 64% of the COVID-19 patients at >300 days after infection, demonstrating durability of neutralizing antibody levels after infection. Importantly, full COVID-19 vaccination of these individuals resulted in higher antibody titers compared to fully vaccinated individuals in the absence of prior infection. These data demonstrate long-lived antibody-mediated immunity after SARS-CoV-2 infection, and a clear benefit of two vaccine doses for recovered individuals.


Subject(s)
COVID-19 , Antibodies, Neutralizing , Antibodies, Viral , COVID-19 Vaccines , Humans , SARS-CoV-2 , Vaccination
3.
Immun Inflamm Dis ; 9(4): 1702-1706, 2021 12.
Article in English | MEDLINE | ID: mdl-34499821

ABSTRACT

INTRODUCTION: One dose of a coronavirus disease 2019 (COVID-19) vaccine can elicit high antibody titers in individuals who were previously infected by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). However, it is unclear how a SARS-CoV-2 infection shortly after a first COVID-19 vaccine dose affects antibody responses. METHODS: Here we investigate residents and staff of a nursing home, where a COVID-19 outbreak occurred shortly after the first BNT162b2 immunization. RESULTS AND CONCLUSIONS: Our data show that individuals who got infected as early as 10 days after their first immunization show antibody levels comparable to fully vaccinated individuals.


Subject(s)
COVID-19 , SARS-CoV-2 , BNT162 Vaccine , COVID-19 Vaccines , Humans , Nursing Homes , Vaccination
4.
Euro Surveill ; 20(46)2015.
Article in English | MEDLINE | ID: mdl-26607018

ABSTRACT

Between 1 August and 6 September 2013, an outbreak of Legionnaires' disease (LD) with 159 suspected cases occurred in Warstein, North Rhine-Westphalia, Germany. The outbreak consisted of 78 laboratory-confirmed cases of LD, including one fatality, with a case fatality rate of 1%. Legionella pneumophila, serogroup 1, subtype Knoxville, sequence type 345, was identified as the epidemic strain. A case-control study was conducted to identify possible sources of infection. In univariable analysis, cases were almost five times more likely to smoke than controls (odds ratio (OR): 4.81; 95% confidence interval (CI): 2.33-9.93; p < 0.0001). Furthermore, cases were twice as likely to live within a 3 km distance from one identified infection source as controls (OR: 2.14; 95% CI: 1.09-4.20; p < 0.027). This is the largest outbreak of LD in Germany to date. Due to a series of uncommon events, this outbreak was most likely caused by multiple sources involving industrial cooling towers. Quick epidemiological assessment, source tracing and shutting down of potential sources as well as rapid laboratory testing and early treatment are necessary to reduce morbidity and mortality. Maintenance of cooling towers must be carried out according to specification to prevent similar LD outbreaks in the future.


Subject(s)
Community-Acquired Infections/epidemiology , Disease Outbreaks , Legionella pneumophila/isolation & purification , Legionnaires' Disease/epidemiology , Adult , Aged , Aged, 80 and over , Air Conditioning , Case-Control Studies , Community-Acquired Infections/microbiology , Environmental Exposure/analysis , Female , Germany/epidemiology , Humans , Legionella pneumophila/classification , Legionella pneumophila/genetics , Male , Middle Aged , Multivariate Analysis , Odds Ratio , Polymerase Chain Reaction , Risk Factors , Serotyping , Severity of Illness Index , Water Microbiology , Water Supply , Young Adult