Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
Add more filters










Publication year range
1.
Materials (Basel) ; 15(20)2022 Oct 21.
Article in English | MEDLINE | ID: mdl-36295470

ABSTRACT

In our study, plasma surface modification was employed to tailor the surface properties of magnesium in terms of surface chemistry, topography, and wettability. For two sets of samples, the plasma treatment involved two steps using two different gases (hydrogen and oxygen), while one set of samples was treated with one step only using oxygen. X-ray photoelectron spectroscopy (XPS) was applied to determine the surface composition, oxidation state of the elements, and the thickness of the surface oxide layer on the Mg samples after different plasma treatments. The surface morphology was characterised using atomic force microscopy (AFM) and scanning electron microscopy (SEM). The wettability was analysed by measuring the static water-contact angles and the corrosion was evaluated using potentiodynamic measurements. The interaction of the live cells with the differently modified Mg surfaces was evaluated in terms of biocompatibility using MG-63 cells (human bone osteosarcoma cells). We have shown that a plasma surface treatment significantly decreased the carbon content and the formation of a 15-20-nm-thick MgO layer was observed. This improves the corrosion resistance, while the biocompatibility was retained, compared to the untreated Mg. A plasma surface treatment is therefore an important step in the development of novel surfaces with improved corrosion resistance for magnesium in biomedical applications.

2.
Polymers (Basel) ; 13(13)2021 Jun 29.
Article in English | MEDLINE | ID: mdl-34209876

ABSTRACT

Cellulose is a promising biomass material suitable for high volume applications. Its potential lies in sustainability, which is becoming one of the leading trends in industry. However, there are certain drawbacks of cellulose materials which limit their use, especially their high wettability and low barrier properties, which can be overcome by applying thin coatings. Plasma technologies present a high potential for deposition of thin environmentally friendly and recyclable coatings. In this paper, two different plasma reactors were used for coating two types of cellulose-based substrates with hexamethyldisiloxane (HMDSO). The changes in surface characteristics were measured by atomic force microscopy (AFM), scanning electron microscopy (SEM), surface free energy and contact angles measurements, X-ray photoelectron spectroscopy (XPS), and secondary ion mass spectrometry (SIMS). Successful oleofobization was observed for an industrial scale reactor where pure HMDSO was used in the absence of oxygen.

3.
Molecules ; 26(5)2021 Mar 05.
Article in English | MEDLINE | ID: mdl-33808010

ABSTRACT

Bacterial infections of medical devices present severe problems connected with long-term antibiotic treatment, implant failure, and high hospital costs. Therefore, there are enormous demands for innovative techniques which would improve the surface properties of implantable materials. Plasma technologies present one of the compelling ways to improve metal's antibacterial activity; plasma treatment can significantly alter metal surfaces' physicochemical properties, such as surface chemistry, roughness, wettability, surface charge, and crystallinity, which all play an important role in the biological response of medical materials. Herein, the most common plasma treatment techniques like plasma spraying, plasma immersion ion implantation, plasma vapor deposition, and plasma electrolytic oxidation as well as novel approaches based on gaseous plasma treatment of surfaces are gathered and presented. The latest results of different surface modification approaches and their influence on metals' antibacterial surface properties are presented and critically discussed. The mechanisms involved in bactericidal effects of plasma-treated surfaces are discussed and novel results of surface modification of metal materials by highly reactive oxygen plasma are presented.


Subject(s)
Anti-Bacterial Agents/pharmacology , Metals/chemistry , Plasma Gases/chemistry , Prostheses and Implants , Prosthesis-Related Infections/microbiology , Anti-Bacterial Agents/chemistry , Bacterial Adhesion , Biofilms , Humans , Metals/pharmacology , Nanostructures/chemistry , Oxidation-Reduction , Pressure , Prosthesis-Related Infections/prevention & control , Surface Properties , Wettability
4.
Polymers (Basel) ; 12(10)2020 Oct 15.
Article in English | MEDLINE | ID: mdl-33076317

ABSTRACT

Novel Extracellular Vesicles (EVs) based diagnostic techniques are promising non-invasive procedures for early stage disease detection which are gaining importance in the medical field. EVs are cell derived particles found in body liquids, especially blood, from which they are isolated for further analysis. However, techniques for their isolation are not fully standardized and require further improvement. Herein modification of polypropylene (PP) tubes by cold Atmospheric Pressure Plasma Jet (APPJ) is suggested to minimize the EVs to surface binding and thus increase EVs isolation yields. The influence of gaseous plasma treatment on surface morphology was studied by Atomic Force Microscopy (AFM), changes in surface wettability by measuring the Water Contact Angle (WCA), while surface chemical changes were analyzed by X-Ray Photoelectron Spectroscopy (XPS). Moreover, PP tubes from different manufacturers were compared. The final isolation yields of EVs were evaluated by flow cytometry. The results of this study suggest that gaseous plasma treatment is an intriguing technique to uniformly alter surface properties of PP tubes and improve EVs isolation yields up to 42%.

5.
Materials (Basel) ; 13(13)2020 Jun 30.
Article in English | MEDLINE | ID: mdl-32630130

ABSTRACT

In this review, strategies for improving the antimicrobial properties of stainless steel (SS) are presented. The main focus given is to present current strategies for surface modification of SS, which alter surface characteristics in terms of surface chemistry, topography and wettability/surface charge, without influencing the bulk attributes of the material. As SS exhibits excellent mechanical properties and satisfactory biocompatibility, it is one of the most frequently used materials in medical applications. It is widely used as a material for fabricating orthopedic prosthesis, cardiovascular stents/valves and recently also for three dimensional (3D) printing of custom made implants. Despite its good mechanical properties, SS lacks desired biofunctionality, which makes it prone to bacterial adhesion and biofilm formation. Due to increased resistance of bacteria to antibiotics, it is imperative to achieve antibacterial properties of implants. Thus, many different approaches were proposed and are discussed herein. Emphasis is given on novel approaches based on treatment with highly reactive plasma, which may alter SS topography, chemistry and wettability under appropriate treatment conditions. This review aims to present and critically discuss different approaches and propose novel possibilities for surface modification of SS by using highly reactive gaseous plasma in order to obtain a desired biological response.

6.
Front Chem ; 7: 581, 2019.
Article in English | MEDLINE | ID: mdl-31552215

ABSTRACT

This work describes the preparation of spin-coated thin polymer films composed of cellulose (CE), ethyl cellulose (EC), and cellulose acetate (CA) in the form of bi- or mono-component coatings on sensors of a quartz crystal microbalance with dissipation monitoring (QCM-D). Depending on the composition and derivative, hydrophilicity can be varied resulting in materials with different surface properties. The surfaces of mono- and bi-component films were also analyzed by atomic force microscopy (AFM) and large differences in the morphologies were found comprising nano- to micrometer sized pores. Extended protein adsorption studies were performed by a QCM-D with 0.1 and 10 mg mL-1 bovine serum albumin (BSA) and 0.1 and 1 mg mL-1 fibrinogen from bovine plasma in phosphate buffered saline. Analysis of the mass of bound proteins was conducted by applying the Voigt model and a comparison was made with the Sauerbrey wet mass of the proteins for all films. The amount of deposited proteins could be influenced by the composition of the films. It is proposed that the observed effects can be exploited in biomaterial science and that they can be used to extent the applicability of bio-based polymer thin films composed of commercial cellulose derivatives.

7.
Carbohydr Polym ; 206: 86-93, 2019 Feb 15.
Article in English | MEDLINE | ID: mdl-30553394

ABSTRACT

Nanocomposites of poly(glycidyl methacrylate) and bacterial cellulose (BC), or poly(poly(ethylene glycol) methacrylate) and BC were produced via the in-situ polymerization of methacrylic monomers, inside the BC 3D network. The nanocomposites surface properties were evaluated by inverse gas chromatography (IGC). The dispersive component of surface energy (γsd) varied between 35.64 - 83.05 mJ m-2 at 25 °C. The surface of the different nanocomposites has a predominant basic character (Kb/Ka = 4.20-4.31). Higher specific interactions with polar probes were found for the nanocomposite bearing pendant epoxide groups, that apart from the low surface area (SBET = 0.83 m2 g-1) and monolayer capacity (nm = 2.18 µmol g-1), exhibits a high value of γsd (88.19 mJ m-2 at 20 °C). These results confirm the potential of IGC to differentiate between nanocomposites with different surface functional groups and to predict their potential interactions with living tissues, body fluids and other materials.

8.
Materials (Basel) ; 11(2)2018 Feb 21.
Article in English | MEDLINE | ID: mdl-29466293

ABSTRACT

The fluorination of the polymer polyethylene terephthalate in plasma created from SF6 or CF4 gas at various pressures was investigated. The surface was analysed by X-ray photoelectron spectroscopy and water contact angle measurements, whereas the plasma was characterized by optical emission spectroscopy. The extent of the polymer surface fluorination was dependent on the pressure. Up to a threshold pressure, the amount of fluorine on the polymer surface and the surface hydrophobicity were similar, which was explained by the full dissociation of the SF6 and CF4 gases, leading to high concentrations of fluorine radicals in the plasma and thus causing the saturation of the polymer surface with fluorine functional groups. Above the threshold pressure, the amount of fluorine on the polymer surface significantly decreased, whereas the oxygen concentration increased, leading to the formation of the hydrophilic surface. This effect, which was more pronounced for the SF6 plasma, was explained by the electronegativity of both gases.

9.
Carbohydr Polym ; 183: 254-262, 2018 Mar 01.
Article in English | MEDLINE | ID: mdl-29352882

ABSTRACT

Bacterial cellulose/polyaniline (BC/PANi) blends present a great potential for several applications. The current study evaluates the impact of using different BC matrixes (drained, freeze-dried and regenerated) and different synthesis conditions (in situ and ex situ) to improve the inherent properties of BC, which were monitored through FTIR-ATR, EDX, XRD, SEM, AFM, swelling, contact angle measurement and IGC. The employment of in situ polymerization onto drained BC presented the most conductive membrane (1.4 × 10-1 S/cm). The crystallinity, swelling capacity, surface energy and acid/base behavior of the BC membranes is substantially modified upon PANi incorporation, being dependent on the BC matrix used, being the freeze-dried BC blends the ones with highest crystallinity (up to 54%), swelling capacity (up to 414%) and surface energy (up to 75.0 mJ/m2). Hence, this work evidenced that the final properties of the BC/PANi blends are greatly influenced by both the BC matrixes and synthesis methods employed.


Subject(s)
Aniline Compounds/chemistry , Cellulose/analogs & derivatives , Electric Conductivity , Gluconacetobacter/chemistry , Membranes, Artificial , Hydrophobic and Hydrophilic Interactions
10.
Polymers (Basel) ; 9(3)2017 Feb 25.
Article in English | MEDLINE | ID: mdl-30970762

ABSTRACT

Samples of polymer polyethylene terephthalate were exposed to a weakly ionized gaseous plasma to modify the polymer surface properties for better cell cultivation. The gases used for treatment were sulfur dioxide and oxygen of various partial pressures. Plasma was created by an electrodeless radio frequency discharge at a total pressure of 60 Pa. X-ray photoelectron spectroscopy showed weak functionalization of the samples' surfaces with the sulfur, with a concentration around 2.5 at %, whereas the oxygen concentration remained at the level of untreated samples, except when the gas mixture with oxygen concentration above 90% was used. Atomic force microscopy revealed highly altered morphology of plasma-treated samples; however, at high oxygen partial pressures this morphology vanished. The samples were then incubated with human umbilical vein endothelial cells. Biological tests to determine endothelialization and possible toxicity of the plasma-treated polyethylene terephthalate samples were performed. Cell metabolic activity (MTT) and in vitro toxic effects of unknown compounds (TOX) were assayed to determine the biocompatibility of the treated substrates. The biocompatibility demonstrated a well-pronounced maximum versus gas composition which correlated well with development of the surface morphology.

11.
Bioelectrochemistry ; 109: 79-86, 2016 Jun.
Article in English | MEDLINE | ID: mdl-26900885

ABSTRACT

Sterilization is the final surface treatment procedure of all implantable devices and is one of the key factors which have to be considered before implementation. Since different sterilization procedures for all implantable devices influence mechanical properties as well as biological response, the influence of different sterilization techniques on titanium nanotubes was studied. Commonly used sterilization techniques such as autoclaving, ultra-violet light sterilization, hydrogen peroxide plasma sterilization as well as the not so frequently used gaseous oxygen plasma sterilization were used. Three different nanotube diameters; 15 nm, 50 nm and 100 nm were employed to study the effects of various sterilization techniques. It was observed that autoclave sterilization resulted in destruction of nanotubular features on all three studied nanotube diameters, while UV-light and both kinds of plasma sterilization did not cause any significant morphological changes on the surfaces. Differences between the sterilization techniques employed influenced cytocompatibility, especially in the case of nanotubes with 100 nm diameter.


Subject(s)
Biocompatible Materials/chemistry , Nanotubes/chemistry , Nanotubes/microbiology , Sterilization/methods , Titanium/chemistry , Cell Line , Cell Survival , Equipment Design , Humans , Hydrogen Peroxide/chemistry , Materials Testing , Nanotubes/ultrastructure , Osteoblasts/cytology , Oxygen/chemistry , Plasma Gases/chemistry , Sterilization/instrumentation , Surface Properties , Ultraviolet Rays
SELECTION OF CITATIONS
SEARCH DETAIL