Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-38882236

ABSTRACT

Introduction: The radiotherapy workflow involves the collaboration of multiple professionals and the execution of several steps to results in an effective treatment. In this study, we described the clinical implementation of an electronic checklist, developed to standardize the process of the chart review prior to the first treatment fraction by the radiation therapists (RTTs). Materials and Methods: A customized electronic checklist was developed based on the recommendations of American Association of Physicists in Medicine (AAPM) Task Groups 275 and 315 and integrated into the Record and Verify System (RVS). The checklist consisted of 16 items requiring binary (yes/no) responses, with mandatory completion and review by RTTs prior to treatment. The utility of the checklist and its impact on workflow were assessed by analysing checklist reports, and by soliciting feedback to RTTs through an anonymized survey. Results: During the first trial phase, from June to November 2023, 285 checklists were completed with a 98% compilation rate and 94.4% review rate. Forty errors were detected, mainly due to missing signed treatment plans and absence of Beam's Eye View documentation. Ninety percent of detected errors were fixed before the treatment start. In 4 cases, the problem could not be fixed before the first fraction, resulting in a suboptimal first treatment. The feedback survey showed that RTTs described the checklist as useful, with minimal impact on workload, and supported its implementation. Discussion: The introduction of a customized electronic checklist improved the detection and correction of errors, thereby enhancing patient safety. The positive response from RTTs and the minimal impact on workflow underscore the value of the checklist as standard practice in radiotherapy departments.

2.
Diagnostics (Basel) ; 14(9)2024 Apr 30.
Article in English | MEDLINE | ID: mdl-38732351

ABSTRACT

This study investigates, through a narrative review, the transformative impact of deep learning (DL) in the field of radiotherapy, particularly in light of the accelerated developments prompted by the COVID-19 pandemic. The proposed approach was based on an umbrella review following a standard narrative checklist and a qualification process. The selection process identified 19 systematic review studies. Through an analysis of current research, the study highlights the revolutionary potential of DL algorithms in optimizing treatment planning, image analysis, and patient outcome prediction in radiotherapy. It underscores the necessity of further exploration into specific research areas to unlock the full capabilities of DL technology. Moreover, the study emphasizes the intricate interplay between digital radiology and radiotherapy, revealing how advancements in one field can significantly influence the other. This interdependence is crucial for addressing complex challenges and advancing the integration of cutting-edge technologies into clinical practice. Collaborative efforts among researchers, clinicians, and regulatory bodies are deemed essential to effectively navigate the evolving landscape of DL in radiotherapy. By fostering interdisciplinary collaborations and conducting thorough investigations, stakeholders can fully leverage the transformative power of DL to enhance patient care and refine therapeutic strategies. Ultimately, this promises to usher in a new era of personalized and optimized radiotherapy treatment for improved patient outcomes.

3.
J Med Imaging Radiat Sci ; 55(2): 339-346, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38403521

ABSTRACT

BACKGROUND: Virtual Environment Radiotherapy Training (VERT) is a virtual tool used in radiotherapy with a dual purpose: patient education and student training. This scoping review aims to identify the applications of VERT to acquire new skills in specific activities of Radiation Therapists (RTTs) clinical practice and education as reported in the literature. This scoping review will identify any gaps in this field and provide suggestions for future research. METHODS: In accordance with Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) extension for scoping reviews and Arskey and O'Malley framework, an electronic search was conducted to retrieve complete original studies, reporting the use and implementation of VERT for teaching skills to RTTs. Studies were searched in PubMed, EMBASE, and SCOPUS databases and included retrieved articles if they investigated the use of VERT for RTTs training. RESULTS: Of 251 titles, 16 articles fulfilled the selection criteria and most of the studies were qualitative evaluation studies (n=5) and pilot studies (n=4). The specific use of VERT for RTTs training was grouped into four categories (Planning CT, Set-up, IGRT, and TPS). CONCLUSION: The use of VERT was described for each category by examining the interaction of the students or trainee RTTs in performing each phase within the virtual environment and describing their perceptions. This system Virtual Reality (VR) enables the development of specific motor skills without interfering and pressurising clinical resources by using clinical equipment in a risk-free offline environment, improving the clinical confidence of students or trainee RTTs. However, even if VR can be integrated into the RTTs training with a great advantage, VERT has still not been embraced. This mainly due to the presence of significant issues and limitations, such as inadequate coverage within the current literature, software and hardware costs.


Subject(s)
Virtual Reality , Humans , Radiotherapy , Clinical Competence
4.
J Med Imaging Radiat Sci ; 55(1): 29-36, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38016852

ABSTRACT

INTRODUCTION: Both cone-beam computed tomography (CBCT) and surface-guided radiotherapy (SGRT) are used for breast patient positioning verification before treatment delivery. SGRT may reduce treatment time and imaging dose by potentially reduce the number of CBCT needed. The aim of this study was to compare the displacements resulting in positioning from the Image Guided Radiation Therapy (IGRT) 3D and SGRT methods and to design a clinical workflow for SGRT implementation in breast radiotherapy to establish an imaging strategy based on the data obtained. METHODS: For this study 128 breast cancer patients treated with 42.5 Gy in 16 fractions using 3D conformal radiotherapy with free breathing technique were enroled. A total of 366 CBCT images were evaluated for patient setup verification and compared with SGRT. Image registrations between planning CT images and CBCT images were performed in mutual agreement and in online mode by three health professionals. Student's paired t-test was used to compare the absolute difference in vector shift, measured in mm, for each orthogonal axis (x, y, z) between SGRT and CBCT methods. The multidisciplinary team evaluated a review of the original clinical workflow for SGRT implementation and data about patients treated with the updated workflow were reported. RESULTS: Comparison of the shifts obtained with IGRT and SGRT for each orthogonal axis (for the x-axes the average displacement was 0.9 ± 0.7 mm, y = 1.1 ± 0.8 mm and z = 1.0 ± 0.7 mm) revealed no significant statistical differences (p > 0.05). Using the updated workflow the difference between SGRT and IGRT displacements was <3 mm in 91.4 % of patients with a reduction in total treatment time of approximately 20 %, due to the reduce frequency of the CBCT images acquisition and matching. CONCLUSIONS: This study has shown that IGRT and SGRT agree in positioning patients with breast cancer within a millimetre tolerance. SGRT can be used for patient positioning, with the advantages of reducing radiation exposure and shorter overall treatment time.


Subject(s)
Breast Neoplasms , Radiotherapy, Intensity-Modulated , Spiral Cone-Beam Computed Tomography , Female , Humans , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/radiotherapy , Image Processing, Computer-Assisted/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Retrospective Studies
5.
PLoS One ; 13(3): e0193776, 2018.
Article in English | MEDLINE | ID: mdl-29534079

ABSTRACT

BACKGROUND: Informing health systems and monitoring hospital performances using administrative data sets, mainly hospital discharge data coded according to International-Classification-Diseases-9edition-Clinical-Modifiers (ICD9-CM), is now commonplace in several countries, but the reliability of diagnostic coding of acute ischemic stroke in the routine practice is uncertain. This study aimed at estimating accuracy of ICD9-CM codes for the identification of acute ischemic stroke and the use of thrombolysis treatment comparing hospital discharge data with medical record review in all the six hospitals of the Florence Area, Italy, through 2015. METHODS: We reviewed the medical records of all the 3915 potential acute stroke events during 2015 across the six hospitals of the Florence Area, Italy. We then estimated sensitivity and Positive Predictive Value of ICD9-CM code-groups 433*1, 434*1 and thrombolysis code 99.10 against medical record review with clinical adjudication. For each false-positive case we obtained the actual diagnosis. For each false-negative case we obtained the primary and secondary ICD9-CM diagnoses. RESULTS: The medical record review identified 1273 acute ischemic stroke events. The hospital discharge records identified 898 among those (true-positive cases),but missed 375 events (false-negative cases), and identified 104 events that were not eventually confirmed as acute ischemic events (false-positive cases). Code-group specific Positive Predictive Value was 85.7% (95%CI,74.6-93.3) for 433*1 and 89.9% (95%CI, 87.8-91.7) for 434*1 codes. Thrombolysis treatment, as identified by ICD9-CM code 99.10, was only documented in 6.0% of acute ischemic stroke events, but was 13.6% in medical record review. CONCLUSIONS: Hospital discharge data were found to be fairly specific but insensitive in the reporting of acute ischemic stroke and thrombolysis, providing misleading indications about both quantity and quality of acute ischemic stroke hospital care. Efforts to improve coding accuracy should precede the use of hospital discharge data to measure hospital performances in acute ischemic stroke care.


Subject(s)
Brain Ischemia/diagnosis , Medical Records , Patient Discharge , Stroke/diagnosis , Aged , Aged, 80 and over , Brain Ischemia/drug therapy , Female , Humans , Italy , Male , Stroke/drug therapy , Thrombolytic Therapy
6.
Br J Pharmacol ; 135(1): 266-74, 2002 Jan.
Article in English | MEDLINE | ID: mdl-11786503

ABSTRACT

1. The effects of the novel mammalian tachykinin, hemokinin 1 (HEK-1), have been investigated by radioligand binding and functional in vitro and in vivo experiments. 2. Similar to SP (K(i)=0.13 nM), HEK-1 inhibited in a concentration-dependent manner and with high affinity [(3)H]-substance P (SP) binding to human NK(1) receptor (K(i)=0.175 nM) while its affinity for [(125)I]-neurokinin A (NKA) binding at human NK(2) receptor was markedly lower (K(i)=560 nM). 3. In isolated bioassays HEK-1 was a full agonist at tachykinin NK(1), NK(2) and NK(3) receptors. In the rat urinary bladder (RUB) HEK-1 was about 3 fold less potent than SP. In the rabbit pulmonary artery (RPA) HEK-1 and in the guinea-pig ileum (GPI), HEK-1 was about 500 fold less potent than NKA and NKB, respectively. 4. The responses to HEK-1 were antagonized by GR 82334 in RUB (pK(B)=5.6+/-0.07), by nepadutant in RPA (pK(B)=8.6+/-0.04) and by SR 142801 in GPI (pK(B)=9.0+/-0.2) with apparent affinities comparable to that measured against tachykinin NK(1), NK(2) and NK(3) receptor-selective agonists, respectively. 5. Intravenous HEK-1 produced dose-related decrease of blood pressure in anaesthetized guinea-pigs (ED(50)=0.1 nmol kg(-1)) and salivary secretion in anaesthetized rats (ED(50)=6 nmol kg(-1)) with potencies similar to that of SP. All these effects were blocked by the selective tachykinin NK(1) receptor antagonist, SR 140333. 6. We conclude that HEK-1 is a full agonist at tachykinin NK(1), NK(2) and NK(3) receptors, possesses a remarkable selectivity for NK(1) as compared to NK(2) or NK(3) receptors and acts in vivo experiments with potency similar to that of SP.


Subject(s)
Protein Precursors/pharmacology , Receptors, Tachykinin/agonists , Tachykinins/pharmacology , Amino Acid Sequence , Animals , Binding Sites , Binding, Competitive , Blood Pressure/drug effects , CHO Cells , Cricetinae , Dose-Response Relationship, Drug , Guinea Pigs , Heart Rate/drug effects , Ileum/drug effects , Ileum/physiology , Male , Muscle, Smooth/drug effects , Muscle, Smooth/physiology , Pulmonary Artery/drug effects , Pulmonary Artery/physiology , Rabbits , Radioligand Assay , Rats , Rats, Wistar , Receptors, Neurokinin-1/agonists , Receptors, Neurokinin-1/metabolism , Receptors, Neurokinin-2/agonists , Receptors, Neurokinin-2/metabolism , Receptors, Neurokinin-3/agonists , Receptors, Neurokinin-3/metabolism , Receptors, Tachykinin/metabolism , Saliva/metabolism , Salivation/drug effects , Salivation/physiology , Sequence Homology, Amino Acid , Urinary Bladder/drug effects , Urinary Bladder/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...