Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 154
Filter
2.
J Clin Med ; 13(6)2024 Mar 14.
Article in English | MEDLINE | ID: mdl-38541906

ABSTRACT

Background: Transcatheter closure of a patent foramen ovale (PFO) is performed in cryptogenic stroke and other conditions. Information is lacking for some devices. Methods: We aimed to evaluate the Figulla Flex II PFO Occluder (FFP) and Figulla Flex UNI Occluder (FFU) through a retrospective multi-center registry. Results: 527 patients were included. Mean age was 48.9 (±13.8) years. The procedure was under transthoracic, transesophageal or intracardiac echocardiography in 185 (35.1%), 193 (36.6%) and 149 (28.3%) cases, respectively, and under general anesthesia in 191 patients (36.2%). The FFP and FFU were used in 408 (77.4%) and 119 (22.6%) cases, respectively. The success rate was 99.1%. Median follow-up was 1.1 (0.5-2.5) years. A new atrial fibrillation/flutter within six months occurred in 14 (2.7%) cases, with no difference between devices. One device embolization in the pulmonary artery was identified two years post-procedure. Residual shunts occurred in 18 (6.9%) cases at 1 year, with TIA in three (16.6%) patients. Out of 437 patients with stroke/TIA, 260 (59%) were followed more than one year after closure. Median follow-up was 2.1 (1.17-3.1) years, with four recurrent strokes/TIA. Conclusions: The FFP and FFU devices are safe and effective for PFO closure, with very few atrial fibrillation/flutter and neurologic events, except in cases with a residual shunt.

3.
Cardiol J ; 31(1): 24-31, 2024.
Article in English | MEDLINE | ID: mdl-36896636

ABSTRACT

BACKGROUND: Management of thrombus burden during primary percutaneous coronary intervention (pPCI) is a key-point, given the high risk of stent malapposition and/or thrombus embolization. These issues are especially important if pPCI involves a coronary bifurcation. Herein, a new experimental bifurcation bench model to analyze thrombus burden behavior was developed. METHODS: On a fractal left main bifurcation bench model, we generated standardized thrombus with human blood and tissue factor. Three provisional pPCI strategies were compared (n = 10/group): 1) balloon-expandable stent (BES), 2) BES completed by proximal optimizing technique (POT), and 3) nitinol self-apposing stent (SAS). The embolized distal thrombus after stent implantation was weighed. Stent apposition and thrombus trapped by the stent were quantified on 2D-OCT. To analyze final stent apposition, a new OCT acquisition was performed after pharmacological thrombolysis. RESULTS: Trapped thrombus was significantly greater with isolated BES than SAS or BES+POT (18.8 ± 5.8% vs. 10.3 ± 3.3% and 6.2 ± 2.1%, respectively; p < 0.05), and greater with SAS than BES+POT (p < 0.05). Isolated BES and SAS tended show less embolized thrombus than BES+POT (5.93 ± 4.32 mg and 5.05 ± 4.56 mg vs. 7.01 ± 4.32 mg, respectively; p = NS). Conversely, SAS and BES+POT ensured perfect final global apposition (0.4 ± 0.6% and 1.3 ± 1.3%, respectively, p = NS) compared to isolated BES (74.0 ± 7.6%, p < 0.05). CONCLUSIONS: This first experimental bench model of pPCI in a bifurcation quantified thrombus trapping and embolization. BES provided the best thrombus trapping, while SAS and BES+POT achieved better final stent apposition. These factors should be taken into account in selecting revascularization strategy.


Subject(s)
Alkanesulfonic Acids , Coronary Artery Disease , Percutaneous Coronary Intervention , Thrombosis , Humans , Prosthesis Design , Stents , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/methods , Thrombosis/etiology , Treatment Outcome , Coronary Angiography/methods , Coronary Artery Disease/diagnosis , Coronary Artery Disease/surgery
4.
Int J Cardiol ; 397: 131632, 2024 Feb 15.
Article in English | MEDLINE | ID: mdl-38048882

ABSTRACT

BACKGROUND: Re-POT (proximal optimization technique (POT)) is a simple provisional sequential technique for percutaneous coronary bifurcation revascularization with better arterial geometry respect compared to classical techniques. Re-POT has demonstrated excellent mechanical and short-term clinical results. The multicenter CABRIOLET registry (NCT03550196) evaluate the long-term clinical benefit of the re-POT sequence in non-selected patients. METHODS: All consecutive patients presenting a coronary bifurcation lesion for which provisional stenting was indicated were included in 5 european centers. Re-POT strategy was systematically attempted. The primary endpoint was target lesion failure (TLF), comprising cardiac death, myocardial infarction, stent thrombosis and target lesion revascularization (TLR) at 12 months' follow-up. The secondary endpoints were the individual components of the primary endpoint, all-cause death, target vessel failure (TVF) and target vessel revascularization (TVR). Complex bifurcation was defined as Medina 0.1.1 or 1.1.1. RESULTS: A total of 500 patients aged 67.7 ± 11.7 years, 78.4% male, were included from 2015 to 2019, 174 of whom (34.8%) were considered having complex bifurcation lesions. Bifurcations involved the left main in 35.2% of cases. The full re-POT sequence was systematically performed in all cases. At 1 year, TLF was 2.0% (1.7% in complex vs. 2.1% in non-complex bifurcation; p = NS), and TLR was 1.6%, (1.1% vs. 1.8% respectively; p = NS). TVF and TVR rates were 3.2% and 2.8%. On multivariate analysis, only multivessel disease was predictive of TLF at 1 year (OR = 1.66 (1.09-2.53), p = 0.02). CONCLUSIONS: In this large prospective all-comer registry, provisional stenting with re-POT technique appeared safe and effective at 1 year, without anatomical bifurcation restriction.


Subject(s)
Coronary Artery Disease , Myocardial Infarction , Percutaneous Coronary Intervention , Humans , Male , Female , Coronary Artery Disease/diagnosis , Coronary Artery Disease/surgery , Coronary Artery Disease/complications , Prospective Studies , Treatment Outcome , Myocardial Infarction/etiology , Percutaneous Coronary Intervention/methods , Stents/adverse effects , Registries , Coronary Angiography/methods
5.
Heart ; 110(4): 245-253, 2024 Jan 29.
Article in English | MEDLINE | ID: mdl-37813560

ABSTRACT

OBJECTIVE: Left atrial appendage closure (LAAC) is recommended to decrease the stroke risk in patients with atrial fibrillation and contraindications to anticoagulation. However, age-stratified data are scarce. The aim of this study was to provide information on the safety and efficacy of LAAC, with emphasis on the oldest patients. METHODS: A nationwide, prospective, multicentre, observational registry was established by 53 French cardiology centres in 2018-2021. The composite primary endpoint included ischaemic stroke, systemic embolism, and unexplained or cardiovascular death. Separate analyses were done in the groups <80 years and ≥80 years. RESULTS: Among the 1053 patients included, median age was 79.7 (73.6-84.3) years; 512 patients (48.6%) were aged ≥80 years. Procedure-related serious adverse events were non-significantly more common in octogenarians (7.0% vs 4.4% in patients aged <80 years, respectively; p=0.07). Despite a higher mean CHA2DS2-VASc score in octogenarians, the rate of thromboembolic events during the study was similar in both groups (3.0 vs 3.1/100 patient-years; p=0.85). By contrast, all-cause mortality was significantly higher in octogenarians (15.3 vs 10.1/100 patient-years, p<0.015), due to a higher rate of non-cardiovascular deaths (8.2 vs 4.9/100 patient-years, p=0.034). The rate of the primary endpoint was 8.1/100 patient-years overall with no statistically significant difference between age groups (9.4 and 7.0/100 patient-years; p=0.19). CONCLUSION: Despite a higher mean CHA2DS2-VASc score in octogenarians, the rate of thromboembolic events after LAAC in this age group was similar to that in patients aged <80 years. TRIAL REGISTRATION NUMBER: ClinicalTrials.gov Registry (NCT03434015).


Subject(s)
Atrial Appendage , Atrial Fibrillation , Brain Ischemia , Stroke , Thromboembolism , Aged , Aged, 80 and over , Humans , Stroke/epidemiology , Stroke/etiology , Stroke/prevention & control , Left Atrial Appendage Closure , Treatment Outcome , Prospective Studies , Brain Ischemia/complications , Atrial Fibrillation/complications , Atrial Fibrillation/surgery , Thromboembolism/epidemiology , Thromboembolism/etiology , Thromboembolism/prevention & control , Atrial Appendage/surgery , Registries , Anticoagulants
7.
BMJ Open ; 13(9): e074584, 2023 09 12.
Article in English | MEDLINE | ID: mdl-37699623

ABSTRACT

INTRODUCTION: After closure of patent foramen ovale (PFO) due to stroke, atrial fibrillation (AF) occurs in up to one in five patients. However, data are sparse regarding the possible pre-existence of AF in these patients prior to PFO closure, and about recurrence of AF in the long term after the procedure. No prospective study to date has investigated these topics in patients with implanted cardiac monitor (ICM). The PFO-AF study (registered with ClinicalTrials.gov under the number NCT04926142) will investigate the incidence of AF occurring within 2 months after percutaneous closure of PFO in patients with prior stroke. AF will be identified using systematic ICM. Secondary objectives are to assess incidence and burden of AF in the 2 months prior to, and up to 2 years after PFO closure. METHODS AND ANALYSIS: Prospective, multicentre, observational study including 250 patients with an indication for PFO closure after stroke, as decided by interdisciplinary meetings with cardiologists and neurologists. Patients will undergo implantation of a Reveal Linq device (Medtronic). Percutaneous PFO closure will be performed 2 months after device implantation. Follow-up will include consultation, ECG and reading of ICM data at 2, 12 and 24 months after PFO closure. The primary endpoint is occurrence of AF at 2 months, defined as an episode of AF or atrial tachycardia/flutter lasting at least 30 s, and recorded by the ICM and/or any AF or atrial tachycardia/flutter documented on ECG during the first 2 months of follow-up. ETHICS AND DISSEMINATION: The study was approved by the Ethics Committee 'Comité de Protection des Personnes (CPP) Sud-Méditerranéen III' on 2 June 2021 and registered with ClinicalTrials.gov (NCT04926142). Findings will be presented in national and international congresses and peer-reviewed journals. TRIAL REGISTRATION NUMBER: NCT04926142.


Subject(s)
Atrial Fibrillation , Atrial Flutter , Foramen Ovale, Patent , Ischemic Stroke , Stroke , Humans , Atrial Fibrillation/complications , Atrial Fibrillation/epidemiology , Foramen Ovale, Patent/complications , Foramen Ovale, Patent/epidemiology , Foramen Ovale, Patent/surgery , Incidence , Observational Studies as Topic , Stroke/epidemiology , Stroke/etiology
8.
Eur Heart J Case Rep ; 7(2): ytad053, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36819877

ABSTRACT

Background: Intra-atrial reentrant tachycardia (IART) is a frequent arrhythmia in patients with Fontan circulation. Although its supraventricular origin, such arrhythmia can be poorly tolerated as it leads to haemodynamic impairment. Concomitant assessment of pressure/volume overload of cardiac chambers due to valvular disease or residual shunts is necessary. Case summary: We report the case of a 33-year-old male with Fontan extracardiac conduit, suffering from IART with initial poor haemodynamic tolerance. He had a medical history of pulmonary atresia with intact ventricular septum and Type 0 bicuspid aortic valve, with a total of four cardiac surgeries. Echocardiography demonstrated a severe impairment of the univentricular ejection fraction and a critical aortic stenosis. Given the limited medical treatment options of the arrhythmia and the risks of another heart surgery, both IART ablation and transcatheter aortic valve replacement (TAVR) were performed during the same procedure. The IART critical isthmus located in the antero-lateral region of the extracardiac conduit was effectively treated with radiofrequency. Rapid pacing during TAVR was provided by a catheter placed in the unique ventricle via a transconduit puncture. The aortic valve was deployed with minimal para-valvular regurgitation and a satisfactory transvalvular gradient. At follow-up, the univentricular ejection fraction normalized and no arrhythmic episode was recorded in absence of anti-arrhythmic drugs. Discussion: This case highlights the need of a collaborative approach for treating complex cases of adult congenital heart disease, suffering from both electrophysiological and haemodynamic disorders. This combination offered an elegant and safest solution for treating concomitantly a life-threatening arrhythmia and an aortic stenosis.

9.
Arch Cardiovasc Dis ; 116(2): 98-105, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36707263

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation now has a major role in the treatment of patients with severe aortic stenosis. However, evidence is scarce on its feasibility and safety to treat patients with pure aortic regurgitation. AIMS: We sought to evaluate the results of transcatheter aortic valve implantation using the balloon-expandable SAPIEN 3 transcatheter heart valve (Edwards Lifesciences, Irvine, CA, USA) in patients with pure aortic regurgitation on native non-calcified valves. METHODS: We conducted a retrospective and prospective French multicentre observational study. We included all patients with symptomatic severe pure aortic regurgitation on native non-calcified valves, contraindicated to or at high risk for surgical valve replacement, who underwent transcatheter aortic valve implantation using the SAPIEN 3 transcatheter heart valve. RESULTS: A total of 37 patients (male sex, 73%) with a median age of 81years (interquartile range 69-85years) were screened using transthoracic echocardiography and computed tomography and were included at eight French centres. At baseline, 83.8% of patients (n=31) had dyspnoea New York Heart Association class≥III. The device success rate was 94.6% (n=35). At 30days, the all-cause mortality rate was 8.1% (n=3) and valve migration occurred in 10.8% of cases (n=4). Dyspnoea New York Heart Association class≤II was seen in 86.5% of patients (n=32), and all survivors had aortic regurgitation grade≤1. At 1-year follow-up, all-cause mortality was 16.2% (n=6), 89.7% (n=26/29) of survivors were in New York Heart Association class≤II and all had aortic regurgitation grade≤2. CONCLUSION: Transcatheter aortic valve implantation using the SAPIEN 3 transcatheter heart valve seems promising to treat selected high-risk patients with pure aortic regurgitation on non-calcified native valves, contraindicated to surgical aortic valve replacement.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Male , Aged , Aged, 80 and over , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Retrospective Studies , Prospective Studies , Treatment Outcome , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Heart Valve Prosthesis/adverse effects , Prosthesis Design
14.
Nat Rev Cardiol ; 19(10): 684-703, 2022 10.
Article in English | MEDLINE | ID: mdl-35449407

ABSTRACT

Since optical coherence tomography (OCT) was first performed in humans two decades ago, this imaging modality has been widely adopted in research on coronary atherosclerosis and adopted clinically for the optimization of percutaneous coronary intervention. In the past 10 years, substantial advances have been made in the understanding of in vivo vascular biology using OCT. Identification by OCT of culprit plaque pathology could potentially lead to a major shift in the management of patients with acute coronary syndromes. Detection by OCT of healed coronary plaque has been important in our understanding of the mechanisms involved in plaque destabilization and healing with the rapid progression of atherosclerosis. Accurate detection by OCT of sequelae from percutaneous coronary interventions that might be missed by angiography could improve clinical outcomes. In addition, OCT has become an essential diagnostic modality for myocardial infarction with non-obstructive coronary arteries. Insight into neoatherosclerosis from OCT could improve our understanding of the mechanisms of very late stent thrombosis. The appropriate use of OCT depends on accurate interpretation and understanding of the clinical significance of OCT findings. In this Review, we summarize the state of the art in cardiac OCT and facilitate the uniform use of this modality in coronary atherosclerosis. Contributions have been made by clinicians and investigators worldwide with extensive experience in OCT, with the aim that this document will serve as a standard reference for future research and clinical application.


Subject(s)
Atherosclerosis , Coronary Artery Disease , Myocardial Infarction , Percutaneous Coronary Intervention , Plaque, Atherosclerotic , Atherosclerosis/pathology , Coronary Angiography/methods , Coronary Artery Disease/complications , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Humans , Myocardial Infarction/complications , Plaque, Atherosclerotic/pathology , Stents , Tomography, Optical Coherence/methods
15.
J Card Surg ; 37(7): 2131-2133, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35398924

ABSTRACT

The use of veno-arterial extracorporeal membrane oxygenation (VA-ECMO) has increased exponentially. Pulmonary congestion is a potentially life-threatening complication of peripheral VA-ECMO. Recently updated guidelines argue for a low threshold of left ventricular (LV) unloading. Although the optimal method of LV unloading is still a matter of debate, the percutaneous approaches became an increasingly used option over time. Here, we present a case of LV unloading with the Atrial Flow Regulator (Occlutech) in a patient supported with peripheral VA-ECMO.


Subject(s)
Extracorporeal Membrane Oxygenation , Heart-Assist Devices , Heart Atria , Heart Ventricles , Humans , Shock, Cardiogenic/etiology , Shock, Cardiogenic/therapy
16.
Stroke ; 53(7): 2249-2259, 2022 07.
Article in English | MEDLINE | ID: mdl-35354295

ABSTRACT

BACKGROUND: Aging is associated with a chronic low-grade inflammatory state. This condition may affect the acute inflammatory response involved in ST-segment-elevation myocardial infarction (STEMI) or acute ischemic stroke (AIS). We sought to compare the profile of a set of circulating inflammatory markers between young and older patients admitted for STEMI or AIS. METHODS: HIBISCUS-STEMI (Cohort of Patients to Identify Biological and Imaging Markers of Cardiovascular Outcomes in ST Elevation Myocardial Infarction) and HIBISCUS-STROKE (Cohort of Patients to Identify Biological and Imaging Markers of Cardiovascular Outcomes in Stroke) are 2 cohort studies that enrolled patients with STEMI treated with primary percutaneous coronary intervention in the cardiac intensive care unit of Lyon and patients with AIS treated with mechanical thrombectomy in the Lyon Stroke Center, respectively from 2016 to 2019. Patients were classified as older if they were ≥65 years and as young if they were <65 years. In both cohorts, CRP (C-reactive protein), IL (interleukin)-6, IL-8, IL-10, MCP (monocyte chemoattractant protein), sTNF-RI (soluble tumor necrosis factor receptor I), sST2 (soluble form suppression of tumorigenicity 2), and VCAM-1 (vascular cellular adhesion molecule-1) were measured on serum collected at 5 time points using enzyme-linked immunosorbent assay. A multiple logistic regression model was performed to detect an association between area under the curve of circulating inflammatory markers within the first 48 hours and older age. RESULTS: A total of 260 patients with STEMI and 164 patients with AIS were included. Of them, there were 76 (29%) and 105 (64%) older patients with STEMI and AIS, respectively. Following multivariable analysis, a high area under the curve of IL-6 and sTNF-RI, a low lymphocyte count, and a high neutrophil-lymphocyte ratio at 24 hours were associated with older age in patients with STEMI and AIS. CONCLUSIONS: Older patients had higher IL-6 and sTFN-RI levels within the first 48 hours associated with a lower lymphocyte count and a higher neutrophil-lymphocyte ratio at 24 hours in both cohorts.


Subject(s)
Ischemic Stroke , ST Elevation Myocardial Infarction , Systemic Inflammatory Response Syndrome , Aged , Biomarkers/analysis , C-Reactive Protein , Humans , Interleukin-6 , Ischemic Stroke/immunology , Ischemic Stroke/therapy , Middle Aged , Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction/immunology , ST Elevation Myocardial Infarction/therapy , Stroke/therapy , Systemic Inflammatory Response Syndrome/immunology
17.
Heart Vessels ; 37(8): 1305-1315, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35133497

ABSTRACT

Ventricular septal rupture (VSR) is a serious complication of ST-elevation myocardial infarction (STEMI) and surgery is the reference treatment. We aimed at describing trends in management and mortality during the last four decades and reporting mortality predictors in these patients. We conducted a single-center retrospective study of patients sustaining a VSR from 1981 to 2020. We screened 274 patients and included 265 for analysis. The number of patients decreased over the years: 80, 88, 56, and 50 in each 10-year time span. In-hospital mortality decreased significantly since 1990 (logrank 0.007). The median age was 72.0 years IQR [66-78] and 188 patients (70.9%) were operated on. IABP was used more routinely (p < 0.0001). In-hospital mortality was assessed at 66.8% (177 patients) and main predictors of death were a time from MI to surgery < 8 days HR 2.7 IC95% [1.9-3.8] p < 0.0001, a Killip class > 2 HR 2.5 IC [1.9-3.4] p < 0.0001 and Euroscore 2 > 20 HR 2.4 IC [1.8-3.2] p < 0.0001. A "time from MI to surgery" of 8 days offers the best ability to discriminate between patients with or without mortality. The ability of "Euroscore 2 and Killip" to detect the patients most likely to wait 8 days for surgery was at 0.81 [0.73-0.89] p < 0.0001. Mortality remains high over the years. Euroscore 2, Killip class, and time from MI to surgery are the main mortality predictors. Patients with a Killip < 3 and a Euroscore < 20 should be monitored at least 8 days since MI before being referred to surgery.


Subject(s)
Myocardial Infarction , ST Elevation Myocardial Infarction , Ventricular Septal Rupture , Aged , Humans , Retrospective Studies , Risk Factors , ST Elevation Myocardial Infarction/complications , Treatment Outcome , Ventricular Septal Rupture/diagnosis , Ventricular Septal Rupture/etiology , Ventricular Septal Rupture/surgery
18.
Radiology ; 303(2): 303-313, 2022 05.
Article in English | MEDLINE | ID: mdl-35166583

ABSTRACT

Background Spatial resolution, soft-tissue contrast, and dose-efficient capabilities of photon-counting CT (PCCT) potentially allow a better quality and diagnostic confidence of coronary CT angiography (CCTA) in comparison to conventional CT. Purpose To compare the quality of CCTA scans obtained with a clinical prototype PCCT system and an energy-integrating detector (EID) dual-layer CT (DLCT) system. Materials and Methods In this prospective board-approved study with informed consent, participants with coronary artery disease underwent retrospective electrocardiographically gated CCTA with both systems after injection of 65-75 mL of 400 mg/mL iodinated contrast agent at 5 mL/sec. A prior phantom task-based quality assessment of the detectability index of coronary lesions was performed. Ultra-high-resolution parameters were used for PCCT (1024 matrix, 0.25-mm section thickness) and EID DLCT (512 matrix, 0.67-mm section thickness). Three cardiac radiologists independently performed a blinded analysis using a five-point quality score (1 = insufficient, 5 = excellent) for overall image quality, diagnostic confidence, and diagnostic quality of calcifications, stents, and noncalcified plaques. A logistic regression model, adjusted for radiologists, was used to evaluate the proportion of improvement in scores with the best method. Results Fourteen consecutive participants (12 men; mean age, 61 years ± 17) were enrolled. Scores of overall quality and diagnostic confidence were higher with PCCT images with a median of 5 (interquartile range [IQR], 2) and 5 (IQR, 1) versus 4 (IQR, 1) and 4 (IQR, 3) with EID DLCT images, using a mean tube current of 255 mAs ± 0 versus 349 mAs ± 111 for EID DLCT images (P < .01). Proportions of improvement with PCCT images for quality of calcification, stent, and noncalcified plaque were 100%, 92% (95% CI: 71, 98), and 45% (95% CI: 28, 63), respectively. In the phantom study, detectability indexes were 2.3-fold higher for lumen and 2.9-fold higher for noncalcified plaques with PCCT images. Conclusion Coronary CT angiography with a photon-counting CT system demonstrated in humans an improved image quality and diagnostic confidence compared with an energy-integrating dual-layer CT. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Sandfort and Bluemke in this issue.


Subject(s)
Computed Tomography Angiography , Photons , Computed Tomography Angiography/methods , Female , Humans , Male , Middle Aged , Prospective Studies , Retrospective Studies , Tomography, X-Ray Computed/methods
19.
Cardiovasc Revasc Med ; 40S: 130-134, 2022 07.
Article in English | MEDLINE | ID: mdl-35033459

ABSTRACT

Carcinoid heart disease is a rare condition affecting mostly tricuspid and pulmonary valves causing right-sided heart failure. Surgical valve replacement is the mainstay of treatment when patients become symptomatic and/or in the presence of right heart remodeling. We present a case of severe pulmonary valve regurgitation secondary to carcinoid heart disease occurring 4 years after a surgical tricuspid replacement, successfully treated with direct transcatheter pulmonary valve implantation without pre-stenting.


Subject(s)
Carcinoid Heart Disease , Heart Failure , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pulmonary Valve Insufficiency , Pulmonary Valve , Carcinoid Heart Disease/complications , Carcinoid Heart Disease/diagnostic imaging , Carcinoid Heart Disease/surgery , Heart Failure/surgery , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis Implantation/adverse effects , Humans , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/surgery , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/etiology , Pulmonary Valve Insufficiency/surgery , Treatment Outcome
20.
J Electrocardiol ; 73: 131-136, 2022.
Article in English | MEDLINE | ID: mdl-31668455

ABSTRACT

BACKGROUND: Pathological Q waves are correlated with infarct size, and Q-wave regression is associated with left ventricular ejection fraction improvement. There are limited data regarding the association of Q-wave regression and clinical outcomes. Our main objective was to assess the association of pathological Q wave evolution after reperfusion with clinical outcomes after anterior STEMI. METHODS: Standard 12-lead electrocardiograms (ECGs) were recorded in 780 anterior STEMI patients treated with primary percutaneous coronary intervention (PCI) from the CIRCUS trial. ECGs were recorded before and 90 min following PCI, as well as at hospitalization discharge and 12 months of follow-up. The number of classic ECG criteria Q waves was scored for each ECG. Patients were classified in the Q wave regression group if they had regression of at least one Q wave between the post-PCI, the discharge and/or one year ECGs. Patients were classified in the Q wave persistent group if they had the same number or greater between the post-PCI, the discharge and/or 1 and one year ECGs. All-cause death and heart failure events were assessed for all patients at one year. RESULTS: There were 323(43%) patients with persistent Q waves (PQ group), 378(49%) patients with Q wave regression (RQ group) and 60(8%) patients with non-Q wave MI (NQ group). Infarct size as measured by the peak creatine kinase was significantly greater in the PQ group compared to the RQ and NQ groups (4633 ±â€¯2784 IU/l vs. 3814 ±â€¯2595 IU/l vs. 1733 ±â€¯1583 IU/l respectively, p < 0.0001). At one year, there were 22 deaths (7%) in the PQ-group, 15 (4%) in the RQ-group and none in the NQ-group (p = 0.04). There was a 4-fold increase in the risk of death or heart failure in the PQ compared to the NQ group (HR 4.7 [1.1; 19.3]; p = 0.03), but there was no significant difference between NQ and RQ groups (HR 3.3 [0.8; 13.8]; p = 0.09). CONCLUSION: In a population of anterior STEMI patients, persistent Q waves defined according to the classic ECG criteria after reperfusion was associated with a 4-fold increase in the risk of heart failure or death compared to non-Q-wave MI, while Q-wave regression was associated with significantly lower risk of events.


Subject(s)
Heart Failure , Myocardial Infarction , Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction , Creatine Kinase/therapeutic use , Electrocardiography , Humans , ST Elevation Myocardial Infarction/diagnosis , ST Elevation Myocardial Infarction/surgery , Stroke Volume , Ventricular Function, Left
SELECTION OF CITATIONS
SEARCH DETAIL
...