Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Eur J Radiol Open ; 9: 100440, 2022.
Article in English | MEDLINE | ID: mdl-36090617

ABSTRACT

Objectives: To identify computed tomography (CT)-based radiomic signatures of cluster of differentiation 8 (CD8)-T cell infiltration and programmed cell death ligand 1 (PD-L1) expression levels in patients with clear-cell renal cell carcinoma (ccRCC). Methods: Seventy-eight patients with pathologically confirmed localized ccRCC, preoperative multiphase CT and tumor resection specimens were enrolled in this retrospective study. Regions of interest (ROI) of the ccRCC volume were manually segmented from the CT images and processed using a radiomics panel comprising of 1708 metrics. The extracted metrics were used as inputs to three machine learning classifiers: Random Forest, AdaBoost, and ElasticNet to create radiomic signatures for CD8-T cell infiltration and PD-L1 expression, respectively. Results: Using a cut-off of 80 lymphocytes per high power field, 59 % were classified to CD8 highly infiltrated tumors and 41 % were CD8 non highly infiltrated tumors, respectively. An ElasticNet classifier discriminated between these two groups of CD8-T cells with an AUC of 0.68 (95 % CI, 0.55-0.80). In addition, based on tumor proportion score with a cut-off of > 1 % tumor cells expressing PD-L1, 76 % were PD-L1 positive and 24 % were PD-L1 negative. An Adaboost classifier discriminated between PD-L1 positive and PD-L1 negative tumors with an AUC of 0.8 95 % CI: (0.66, 0.95). 3D radiomics metrics of graylevel co-occurrence matrix (GLCM) and graylevel run-length matrix (GLRLM) metrics drove the performance for CD8-Tcell and PD-L1 classification, respectively. Conclusions: CT-radiomic signatures can differentiate tumors with high CD8-T cell infiltration with moderate accuracy and positive PD-L1 expression with good accuracy in ccRCC.

2.
Eur Radiol ; 32(4): 2552-2563, 2022 Apr.
Article in English | MEDLINE | ID: mdl-34757449

ABSTRACT

OBJECTIVES: To evaluate the utility of CT-based radiomics signatures in discriminating low-grade (grades 1-2) clear cell renal cell carcinomas (ccRCC) from high-grade (grades 3-4) and low TNM stage (stages I-II) ccRCC from high TNM stage (stages III-IV). METHODS: A total of 587 subjects (mean age 60.2 years ± 12.2; range 22-88.7 years) with ccRCC were included. A total of 255 tumors were high grade and 153 were high stage. For each subject, one dominant tumor was delineated as the region of interest (ROI). Our institutional radiomics pipeline was then used to extract 2824 radiomics features across 12 texture families from the manually segmented volumes of interest. Separate iterations of the machine learning models using all extracted features (full model) as well as only a subset of previously identified robust metrics (robust model) were developed. Variable of importance (VOI) analysis was performed using the out-of-bag Gini index to identify the top 10 radiomics metrics driving each classifier. Model performance was reported using area under the receiver operating curve (AUC). RESULTS: The highest AUC to distinguish between low- and high-grade ccRCC was 0.70 (95% CI 0.62-0.78) and the highest AUC to distinguish between low- and high-stage ccRCC was 0.80 (95% CI 0.74-0.86). Comparable AUCs of 0.73 (95% CI 0.65-0.8) and 0.77 (95% CI 0.7-0.84) were reported using the robust model for grade and stage classification, respectively. VOI analysis revealed the importance of neighborhood operation-based methods, including GLCM, GLDM, and GLRLM, in driving the performance of the robust models for both grade and stage classification. CONCLUSION: Post-validation, CT-based radiomics signatures may prove to be useful tools to assess ccRCC grade and stage and could potentially add to current prognostic models. Multiphase CT-based radiomics signatures have potential to serve as a non-invasive stratification schema for distinguishing between low- and high-grade as well as low- and high-stage ccRCC. KEY POINTS: • Radiomics signatures derived from clinical multiphase CT images were able to stratify low- from high-grade ccRCC, with an AUC of 0.70 (95% CI 0.62-0.78). • Radiomics signatures derived from multiphase CT images yielded discriminative power to stratify low from high TNM stage in ccRCC, with an AUC of 0.80 (95% CI 0.74-0.86). • Models created using only robust radiomics features achieved comparable AUCs of 0.73 (95% CI 0.65-0.80) and 0.77 (95% CI 0.70-0.84) to the model with all radiomics features in classifying ccRCC grade and stage, respectively.


Subject(s)
Carcinoma, Renal Cell , Kidney Neoplasms , Adult , Aged , Aged, 80 and over , Area Under Curve , Carcinoma, Renal Cell/diagnostic imaging , Carcinoma, Renal Cell/pathology , Humans , Kidney Neoplasms/diagnostic imaging , Kidney Neoplasms/pathology , Machine Learning , Middle Aged , Retrospective Studies , Tomography, X-Ray Computed/methods , Young Adult
3.
Eur Radiol ; 31(2): 1011-1021, 2021 Feb.
Article in English | MEDLINE | ID: mdl-32803417

ABSTRACT

OBJECTIVES: Using a radiomics framework to quantitatively analyze tumor shape and texture features in three dimensions, we tested its ability to objectively and robustly distinguish between benign and malignant renal masses. We assessed the relative contributions of shape and texture metrics separately and together in the prediction model. MATERIALS AND METHODS: Computed tomography (CT) images of 735 patients with 539 malignant and 196 benign masses were segmented in this retrospective study. Thirty-three shape and 760 texture metrics were calculated per tumor. Tumor classification models using shape, texture, and both metrics were built using random forest and AdaBoost with tenfold cross-validation. Sensitivity analyses on five sub-cohorts with respect to the acquisition phase were conducted. Additional sensitivity analyses after multiple imputation were also conducted. Model performance was assessed using AUC. RESULTS: Random forest classifier showed shape metrics featuring within the top 10% performing metrics regardless of phase, attaining the highest variable importance in the corticomedullary phase. Convex hull perimeter ratio is a consistently high-performing shape feature. Shape metrics alone achieved an AUC ranging 0.64-0.68 across multiple classifiers, compared with 0.67-0.75 and 0.68-0.75 achieved by texture-only and combined models, respectively. CONCLUSION: Shape metrics alone attain high prediction performance and high variable importance in the combined model, while being independent of the acquisition phase (unlike texture). Shape analysis therefore should not be overlooked in its potential to distinguish benign from malignant tumors, and future radiomics platforms powered by machine learning should harness both shape and texture metrics. KEY POINTS: • Current radiomics research is heavily weighted towards texture analysis, but quantitative shape metrics should not be ignored in their potential to distinguish benign from malignant renal tumors. • Shape metrics alone can attain high prediction performance and demonstrate high variable importance in the combined shape and texture radiomics model. • Any future radiomics platform powered by machine learning should harness both shape and texture metrics, especially since tumor shape (unlike texture) is independent of the acquisition phase and more robust from the imaging variations.


Subject(s)
Carcinoma, Renal Cell , Kidney Neoplasms , Carcinoma, Renal Cell/diagnostic imaging , Diagnosis, Differential , Humans , Kidney Neoplasms/diagnostic imaging , Retrospective Studies , Tomography, X-Ray Computed
4.
J Ultrasound Med ; 39(1): 19-28, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31237009

ABSTRACT

A systematic search was conducted to categorize targeted ultrasound contrast agents (UCAs) used in cancer-related angiogenesis detection. We identified 15 unique contrast agents from 2008 to March 2018. Most primary research articles studied UCAs targeted to vascular endothelial growth factor receptor or αv ß3 -integrin. Breast cancer and colon cancer are the most common neoplastic processes in which these agents were studied. BR55 (Bracco Research SA, Geneva, Switzerland), a vascular endothelial growth factor receptor-targeting UCA, is the first targeted UCA that has completed phase 0 trials. Our review identifies a gap in the literature regarding the application of targeted UCAs in cancer models beyond breast and colon cancers and identifies other promising UCAs.


Subject(s)
Contrast Media , Image Enhancement/methods , Neoplasms/blood supply , Neovascularization, Pathologic/diagnostic imaging , Ultrasonography/methods , Female , Humans , Male
5.
J Appl Clin Med Phys ; 20(8): 155-163, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31222919

ABSTRACT

OBJECTIVE: To determine the intra-, inter- and test-retest variability of CT-based texture analysis (CTTA) metrics. MATERIALS AND METHODS: In this study, we conducted a series of CT imaging experiments using a texture phantom to evaluate the performance of a CTTA panel on routine abdominal imaging protocols. The phantom comprises of three different regions with various textures found in tumors. The phantom was scanned on two CT scanners viz. the Philips Brilliance 64 CT and Toshiba Aquilion Prime 160 CT scanners. The intra-scanner variability of the CTTA metrics was evaluated across imaging parameters such as slice thickness, field of view, post-reconstruction filtering, tube voltage, and tube current. For each scanner and scanning parameter combination, we evaluated the performance of eight different types of texture quantification techniques on a predetermined region of interest (ROI) within the phantom image using 235 different texture metrics. We conducted the repeatability (test-retest) and robustness (intra-scanner) test on both the scanners and the reproducibility test was conducted by comparing the inter-scanner differences in the repeatability and robustness to identify reliable CTTA metrics. Reliable metrics are those metrics that are repeatable, reproducible and robust. RESULTS: As expected, the robustness, repeatability and reproducibility of CTTA metrics are variably sensitive to various scanner and scanning parameters. Entropy of Fast Fourier Transform-based texture metrics was overall most reliable across the two scanners and scanning conditions. Post-processing techniques that reduce image noise while preserving the underlying edges associated with true anatomy or pathology bring about significant differences in radiomic reliability compared to when they were not used. CONCLUSION: Following large-scale validation, identification of reliable CTTA metrics can aid in conducting large-scale multicenter CTTA analysis using sample sets acquired using different imaging protocols, scanners etc.


Subject(s)
Algorithms , Image Processing, Computer-Assisted/methods , Phantoms, Imaging , Tomography Scanners, X-Ray Computed , Tomography, X-Ray Computed/methods , Humans , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...