1.
JACC Case Rep
; 2(10): 1443-1447, 2020 Aug.
Article
in English
| MEDLINE
| ID: mdl-34316992
ABSTRACT
Mediastinal radiation-induced severe calcific valve disease carries increased operative mortality. Transcatheter therapies are also challenging and potentially hazardous. We used a unique constellation of imaging and planning technologies to successfully plan, simulate, and perform novel combined transcatheter aortic valve replacement and valve in mitral annular calcification in a high-risk patient. (Level of Difficulty: Advanced.).