Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Br J Haematol ; 2024 May 02.
Article in English | MEDLINE | ID: mdl-38698705

ABSTRACT

Diagnosing chronic myeloid leukaemia (CML) during pregnancy is rare. Tyrosine kinase inhibitors (TKIs) have traditionally been contraindicated owing to their teratogenicity. Management decisions should consider the risks to mother and foetus of uncontrolled disease and teratogenic medications. Further cases are required to build upon the paucity of current literature. We report 22 cases of CML diagnosed during pregnancy from 2002 to date. Twenty-one pregnancies resulted in healthy babies and one patient miscarried. Some patients remained untreated throughout pregnancy but the majority received one or both of interferon-α and leucapheresis. One patient was started on imatinib at Week 26, and one on hydroxycarbamide in the third trimester. We report haematological parameters during pregnancy to provide clinicians with realistic expectations of management. There were no fetal abnormalities related to treatment during pregnancy. Seventeen patients achieved at least major molecular response on first-line TKI. A diagnosis of CML during pregnancy can be managed without significant consequences for mother or child. Leucapheresis and interferon-α are generally safe throughout pregnancy. Despite having been avoided previously, there is growing evidence that certain TKIs may be used in particular circumstances during the later stages of pregnancy. Future work should aim to further elucidate this safety profile.

2.
Expert Rev Hematol ; 16(5): 325-332, 2023 05.
Article in English | MEDLINE | ID: mdl-37038615

ABSTRACT

INTRODUCTION: TKIs are paradigmatic in CML management and offer patients the prospect of a normal life expectancy. As a consequence, the focus of both the clinician and patient has shifted to considerations of quality of life, including the ability to parent children. Unfortunately, TKIs are teratogenic so that alternative treatment options may be required during pregnancy to adequately control disease and minimize risk. AREAS COVERED: In this review, we summarize and provide an overview of the literature on the management of CML in women of childbearing age. We discuss the various treatment options as well as their advantages, disadvantages, and safety considerations. We discuss CML in the context of: 1) planned pregnancies with CML; 2) unplanned pregnancies with CML; 3) CML diagnosed during pregnancy. EXPERT OPINION: Confidence in managing pregnancy and CML continues to grow. In the majority of cases, with careful planning and counseling, no treatment is required and disease control can be safely regained after pregnancy ends. For those who require treatment, various options are available and there is growing evidence to suggest that some TKIs may be safe in the later stages of pregnancy.


Subject(s)
Leukemia, Myelogenous, Chronic, BCR-ABL Positive , Pregnancy Complications, Neoplastic , Pregnancy , Child , Humans , Female , Quality of Life , Protein Kinase Inhibitors/adverse effects , Leukemia, Myelogenous, Chronic, BCR-ABL Positive/diagnosis , Leukemia, Myelogenous, Chronic, BCR-ABL Positive/drug therapy , Protein-Tyrosine Kinases , Pregnancy Complications, Neoplastic/diagnosis , Pregnancy Complications, Neoplastic/therapy
4.
Anaesthesia ; 74(7): 891-895, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31069798

ABSTRACT

Tracheal intubation with a double-lumen tube can be more challenging than with a single-lumen tube. A bougie can be used to facilitate intubation. Case reports have described fragment shearing from bougies when they are removed from the tube after intubation. These fragments have the potential to cause harm. It has even been suggested that bougies and double-lumen tubes should not be used together. We conducted a benchtop trial to investigate factors that influence the risk of shearing. We investigated three brands of double-lumen tube (each in three sizes and both lateralities) and four brands of bougie. We simulated one intubation and 29 further insertions/removals of bougie with every bougie-double-lumen tube combination. We inspected the inside of the tube for evidence of shearing after first, tenth and thirtieth removals. We found that brand of bougie, brand of double-lumen tube and size of double-lumen tube (but not its laterality) all influenced the degree of shearing. Certain bougie-double-lumen tube combinations produced a particularly high degree of shearing, so these should be avoided.


Subject(s)
Device Removal/methods , Equipment Failure/statistics & numerical data , Intubation, Intratracheal/instrumentation , Equipment Design , Manikins
SELECTION OF CITATIONS
SEARCH DETAIL
...