Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Pacing Clin Electrophysiol ; 46(8): 942-947, 2023 08.
Article in English | MEDLINE | ID: mdl-37378419

ABSTRACT

INTRODUCTION: Cephalic vein cutdown (CVC) and axillary vein puncture (AVP) are both recommended for transvenous implantation of leads for cardiac implantable electronic devices (CIEDs). Nonetheless, it is still debated which of the two techniques has a better safety and efficacy profile. METHODS: We systematically searched Medline, Embase, and Cochrane electronic databases up to September 5, 2022, for studies that evaluated the efficacy and safety of AVP and CVC reporting at least one clinical outcome of interest. The primary endpoints were acute procedural success and overall complications. The effect size was estimated using a random-effect model as risk ratio (RR) and relative 95% confidence interval (CI). RESULTS: Overall, seven studies were included, which enrolled 1771 and 3067 transvenous leads (65.6% [n = 1162] males, average age 73.4 ± 14.3 years). Compared to CVC, AVP showed a significant increase in the primary endpoint (95.7 % vs. 76.1 %; RR: 1.24; 95% CI: 1.09-1.40; p = .001) (Figure 1). Total procedural time (mean difference [MD]: -8.25 min; 95% CI: -10.23 to -6.27; p < .0001; I2  = 0%) and venous access time (MD: -6.24 min; 95% CI: -7.01 to -5.47; p < .0001; I2  = 0%) were significantly shorter with AVP compared to CVC. No differences were found between AVP and CVC for incidence overall complications (RR: 0.56; 95% CI: 0.28-1.10; p = .09), pneumothorax (RR: 0.72; 95% CI: 0.13-4.0; p = .71), lead failure (RR: 0.58; 95% CI: 0.23-1.48; p = .26), pocket hematoma/bleeding (RR: 0.58; 95% CI: 0.15-2.23; p = .43), device infection (RR: 0.95; 95% CI: 0.14-6.60; p = .96) and fluoroscopy time (MD: -0.24 min; 95% CI: -0.75 to 0.28; p = .36). CONCLUSION: Our meta-analysis suggests that AVP may improve procedural success and reduce total procedural time and venous access time compared to CVC.


Subject(s)
Axillary Vein , Venous Cutdown , Male , Humans , Middle Aged , Aged , Aged, 80 and over , Axillary Vein/surgery , Venous Cutdown/methods , Subclavian Vein , Punctures/methods , Heart
2.
Medicina (Kaunas) ; 57(3)2021 Feb 26.
Article in English | MEDLINE | ID: mdl-33652714

ABSTRACT

A recent surveillance analysis indicates that cardiac arrest/death occurs in ≈1:50,000 professional or semi-professional athletes, and the most common cause is attributable to life-threatening ventricular arrhythmias (VAs). It is critically important to diagnose any inherited/acquired cardiac disease, including coronary artery disease, since it frequently represents the arrhythmogenic substrate in a substantial part of the athletes presenting with major VAs. New insights indicate that athletes develop a specific electro-anatomical remodeling, with peculiar anatomic distribution and VAs patterns. However, because of the scarcity of clinical data concerning the natural history of VAs in sports performers, there are no dedicated recommendations for VA ablation. The treatment remains at the mercy of several individual factors, including the type of VA, the athlete's age, and the operator's expertise. With the present review, we aimed to illustrate the prevalence, electrocardiographic (ECG) features, and imaging correlations of the most common VAs in athletes, focusing on etiology, outcomes, and sports eligibility after catheter ablation.


Subject(s)
Catheter Ablation , Sports , Arrhythmias, Cardiac , Athletes , Electrocardiography , Heart , Humans
3.
Pacing Clin Electrophysiol ; 43(8): 828-837, 2020 08.
Article in English | MEDLINE | ID: mdl-32460366

ABSTRACT

BACKGROUND: Cardiac sympathetic denervation (CSD) is being used in the management of refractory ventricular tachycardia (VT) and electrical storm. However, data on the role of CSD in the management of ventricular arrhythmia is limited. METHODS: We performed a meta-analysis of retrospective studies to calculate the pooled rate of freedom from VT and the standard mean difference of ICD shocks before and after CSD. RESULTS: 14 nonrandomized studies with a total of 311 patients with refractory VT or electrical storm were included. At a mean follow up of 15 ± 10.7 months, the pooled rate of freedom from VT (VT nonrecurrence rate) after CSD in all causes of arrhythmia was 60% (range 48.8% to 70%, I2   = 43%). When analysis was restricted to only arrhythmias caused by conditions other than catecholaminergic polymorphic ventricular tachycardia (CPVT) and long QT syndrome (LQTS), the pooled VT non-recurrence rate was 50% (range 41% to 58%, I2   = 5%). After CSD, mean total number of ICD shocks per person diminished by 3.01 (95% CI 1.09-4.94, P = .002, I2  = 96%) in overall analysis and by 0.97(95% CI 0.41-1.5, P = .001, I2  = 45%) when CPVT and LQTS were excluded. CONCLUSION: In patients with refractory VT or electrical storm, CSD is associated with pooled VT nonrecurrence rate of 60% at a mean follow-up of 15 ± 10.7 months. CSD was also associated with significantly lower mean number ICD shocks per person. Further studies are needed to validate this finding in a prospective setting.


Subject(s)
Sympathectomy/methods , Tachycardia, Ventricular/physiopathology , Tachycardia, Ventricular/surgery , Defibrillators, Implantable , Humans
5.
Int J Cardiol ; 220: 149-54, 2016 Oct 01.
Article in English | MEDLINE | ID: mdl-27379917

ABSTRACT

BACKGROUND: A new post-myocardial infarction (MI) therapy is injection of high-water-content polymeric biomaterial gels (hydrogels) into damaged myocardium to modulate cardiac negative remodeling and preserve heart function. METHODS: We investigated the therapeutic potential of a novel gelatinized alginate hydrogel with a unique microstructure of uniform capillary-like channels (termed Capgel). Shortly (48h) after induced anterior MI, Sprague Dawley rats received intramyocardial injection of Capgel directly into the antero-septal wall at the infarct border zone (n=12) or no injection (n=10, controls). Echocardiograms were performed at 48h (week 0) and 4weeks (week 4) to evaluate left ventricular function. RESULTS: Echocardiograms showed 27% improvement of left ventricular systolic function over time with gel injection: fractional shortening increased from 26±3% at week 0 to 33±2% at week 4 (p=0.001). Capgel was present at the injection site after 4weeks, but was minimal at 8weeks. The remaining gel was heavily populated by CD68(+) macrophages with CD206(+) clusters and blood vessels. An in vitro experiment was performed to assess Angiotensin-(1-7) released from Capgel. Angiotensin-(1-7) was released from the Capgel in a sustained manner for 90days. CONCLUSIONS: Use of Capgel, a degradable, bioactive hydrogel composed of gelatinized capillary-alginate gel, appears safe for intramyocardial injection, is associated with improved left ventricular function after MI in rats, and may provide a long-term supply of Angiotensin-(1-7).


Subject(s)
Alginates , Angiotensin I , Myocardial Infarction , Peptide Fragments , Ventricular Function, Left/physiology , Ventricular Remodeling/drug effects , Alginates/chemistry , Alginates/pharmacology , Angiotensin I/chemistry , Angiotensin I/pharmacology , Animals , Biocompatible Materials/chemistry , Biocompatible Materials/pharmacology , Disease Models, Animal , Echocardiography/methods , Gelatin/pharmacology , Glucuronic Acid/chemistry , Glucuronic Acid/pharmacology , Hexuronic Acids/chemistry , Hexuronic Acids/pharmacology , Hydrogels/pharmacology , Injections, Intralesional/methods , Myocardial Infarction/physiopathology , Myocardial Infarction/therapy , Peptide Fragments/chemistry , Peptide Fragments/pharmacology , Rats , Rats, Sprague-Dawley , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...