Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
1.
Minerva Cardioangiol ; 63(6): 547-61, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26397947

ABSTRACT

The onset of symptoms of heart failure is a landmark in the natural history of aortic stenosis, and is associated with a dramatic reduction in survival. Aortic valve replacement markedly increases life-expectancy in such patients. However, the presence of heart failure and/or left ventricular dysfunction are strong predictors of poor acute and late mortality after cardiac surgery and the most frequent conditions leading to deny surgical aortic valve replacement in elderly patients. The last decade has witnessed the development of transcatheter aortic valve implantation (TAVI) and, consequently, the resurgence of percutaneous balloon aortic valvuloplasty (PBAV) and, both, are currently routine therapy for high-risk patients. These minimally invasive procedures are appealing therapeutic options for the subset of patients with heart failure and or/left ventricular systolic dysfunction. The available evidence on the results of PBAV and TAVI therapies in this setting is discussed and a management strategy is proposed.


Subject(s)
Aortic Valve Stenosis/therapy , Balloon Valvuloplasty/methods , Transcatheter Aortic Valve Replacement/methods , Aged , Aortic Valve Stenosis/mortality , Heart Failure/complications , Heart Failure/mortality , Humans , Risk , Ventricular Dysfunction, Left/complications , Ventricular Dysfunction, Left/mortality
2.
J Am Coll Cardiol ; 66(19): 2075-2088, 2015.
Article in English | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1063629

ABSTRACT

BACKGROUND:Cardiac biomarker release signifying myocardial injury post-transcatheter aortic valve replacement (TAVR) is common, yet its clinical impact within a large TAVR cohort receiving differing types of valve and procedural approaches is unknown.OBJECTIVES:This study sought to determine the incidence, clinical impact, and factors associated with cardiac biomarker elevation post TAVR.METHODS:This multicenter study included 1,131 consecutive patients undergoing TAVR with balloon-expandable (58%) or self-expandable (42%) valves. Transfemoral and transapical (TA) approaches were selected in 73.1% and 20.3% of patients, respectively. Creatine kinase-myocardial band (CK-MB) measurements were obtained at baseline and at several time points within the initial 72 h post TAVR. Echocardiography was performed at baseline and at 6- to 12-month follow-up.RESULTS:Overall, 66% of the TAVR population demonstrated some degree of myocardial injury as determined by a rise in CK-MB levels (peak value: 1.6-fold [interquartile range (IQR): 0.9 to 2.8-fold]). A TA approach and major procedural complications were independently associated with higher peak of CK-MB levels (p < 0.01 for all), which translated into impaired systolic left ventricular function at 6 to 12 months post TAVR (p < 0.01). A greater rise in CK-MB levels independently associated with an increased 30-day, late (median of 21 [IQR: 8 to 36] months) overall and cardiovascular mortality (p < 0.001 for all)...


Subject(s)
Biomarkers , Creatine Kinase , Carotid Stenosis , Transcatheter Aortic Valve Replacement
3.
Minerva Cardioangiol ; 61(5): 499-512, 2013 Oct.
Article in English | MEDLINE | ID: mdl-24096245

ABSTRACT

Paravalvular aortic regurgitation (AR) is a frequent complication following transcatheter aortic valve implantation (TAVI) with an incidence of mild to moderate AR almost systematically higher than 30%. Moreover, several studies have shown that AR has a negative impact on short and mid-term mortality. Balloon postdilation has been proposed as an initial periprocedural option for patients with paravalvular AR to obtain a better expansion of the stent valve frame and potentially reduce the severity of the leak. The aim of this review is to discuss the current available literature on balloon postdilation as a treatment of paravalvular AR after TAVI, its impact on clinical events and future perspectives.


Subject(s)
Angioplasty, Balloon/methods , Aortic Valve Insufficiency/therapy , Heart Valve Prosthesis Implantation/adverse effects , Aortic Valve/pathology , Aortic Valve/surgery , Aortic Valve Insufficiency/epidemiology , Aortic Valve Insufficiency/etiology , Aortic Valve Stenosis/surgery , Cardiac Catheterization/methods , Heart Valve Prosthesis Implantation/methods , Humans , Incidence , Severity of Illness Index , Time Factors , Treatment Outcome
4.
Circulation ; 122(19): 1928-36, 2010 Nov 09.
Article in English | MEDLINE | ID: mdl-20975002

ABSTRACT

BACKGROUND: Patients with severe aortic stenosis and reduced left ventricular ejection fraction (LVEF) have a poor prognosis with conservative therapy but a high operative mortality when treated surgically. Recently, transcatheter aortic valve implantation (TAVI) has emerged as an alternative to surgical aortic valve replacement (SAVR) for patients considered at high or prohibitive operative risk. The objective of this study was to compare TAVI and SAVR with respect to postoperative recovery of LVEF in patients with severe aortic stenosis and reduced LV systolic function. METHODS AND RESULTS: Echocardiographic data were prospectively collected before and after the procedure in 200 patients undergoing SAVR and 83 patients undergoing TAVI for severe aortic stenosis (aortic valve area ≤1 cm(2)) with reduced LV systolic function (LVEF ≤50%). TAVI patients were significantly older (81±8 versus 70±10 years; P<0.0001) and had more comorbidities compared with SAVR patients. Despite similar baseline LVEF (34±11% versus 34±10%), TAVI patients had better recovery of LVEF compared with SAVR patients (ΔLVEF, 14±15% versus 7±11%; P=0.005). At the 1-year follow-up, 58% of TAVI patients had a normalization of LVEF (>50%) as opposed to 20% in the SAVR group. On multivariable analysis, female gender (P=0.004), lower LVEF at baseline (P=0.005), absence of atrial fibrillation (P=0.01), TAVI (P=0.007), and larger increase in aortic valve area after the procedure (P=0.01) were independently associated with better recovery of LVEF. CONCLUSION: In patients with severe aortic stenosis and depressed LV systolic function, TAVI is associated with better LVEF recovery compared with SAVR. TAVI may provide an interesting alternative to SAVR in patients with depressed LV systolic function considered at high surgical risk.


Subject(s)
Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation/methods , Stroke Volume/physiology , Aged , Aged, 80 and over , Aortic Valve/transplantation , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/mortality , Atrial Fibrillation/physiopathology , Atrial Fibrillation/surgery , Bioprosthesis , Echocardiography/methods , Female , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/mortality , Humans , Male , Middle Aged , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/mortality , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/surgery , Myocardial Infarction/complications , Myocardial Infarction/epidemiology , Sex Characteristics , Stroke/epidemiology , Stroke/mortality , Treatment Outcome , Ventricular Function, Left/physiology
7.
Heart ; 89(3): 311-5, 2003 Mar.
Article in English | MEDLINE | ID: mdl-12591838

ABSTRACT

OBJECTIVE: To assess the structural and functional characteristics of pulmonary arteries by intravascular ultrasound (IVUS) in the setting of primary pulmonary hypertension, and to correlate the ultrasound findings with haemodynamic variables and mortality at follow up. DESIGN: Prospective observational study. SETTING: University hospital (tertiary referral centre). PATIENTS: 20 consecutive patients with primary pulmonary hypertension (16 female; mean (SD) age, 39 (14) years). METHODS: Cardiac catheterisation and simultaneous IVUS of pulmonary artery branches at baseline and after infusion of epoprostenol. RESULTS: 33 pulmonary arteries with a mean diameter of 3.91 (0.80) mm were imaged, and wall thickening was observed in all cases, 64% being eccentric. Mean wall thickness was 0.37 (0.13) mm, percentage wall area 31.0 (9.3)%, pulsatility 14.6 (4.8)%, and pulmonary/elastic strain index 449 (174) mm Hg. No correlation was observed between IVUS findings and haemodynamic variables. Epoprostenol infusion increased pulsatility by 53% and decreased the pulmonary/elastic strain index by 41% (p = 0.0001), irrespective of haemodynamic changes. At 18 (12) months follow up, nine patients had died. A reduced pulsatility and an increased pulmonary/elastic strain index were associated with increased mortality at follow up (12.0 (4.4)% v 16.4 (4.4)%, p = 0.03; 369 (67) v 546 (216) mm Hg, p = 0.02). CONCLUSIONS: IVUS demonstrated pulmonary artery wall abnormalities in all patients with primary pulmonary hypertension, mostly eccentric. The severity of the changes did not correlate with haemodynamic variables, and epoprostenol improved pulmonary vessel stiffness. There was an association between impaired pulmonary artery functional state as determined by IVUS and mortality at follow up.


Subject(s)
Hypertension, Pulmonary/diagnostic imaging , Pulmonary Artery/diagnostic imaging , Adolescent , Adult , Elasticity , Endosonography/methods , Female , Follow-Up Studies , Humans , Hypertension, Pulmonary/pathology , Male , Middle Aged , Prospective Studies , Pulmonary Artery/pathology , Stroke Volume/physiology
8.
An Esp Pediatr ; 57(1): 66-9, 2002 Jul.
Article in Spanish | MEDLINE | ID: mdl-12139896

ABSTRACT

We present the case of a 6-year old boy with a mid-muscular residual ventricular septal defect (VSD) of difficult surgical access, who underwent transcatheter closure using the Amplatzer(TM) VSD occluder. Transcatheter closure was guided by transthoracic echocardiography and successful closure was achieved with a 12 mm diameter VSD occluder, with no complications. Chest radiography showed a considerable decrease in cardiomegaly and normalization of pulmonary vascular markings before 24 hours, and echocardiography showed correct positioning of the Amplatzer(TM) VSD device without residual shunt through the device and minimal residual shunt in an apical VSD. After a 3-month follow-up, the patient was asymptomatic and echocardiography showed that the device was correctly positioned with minimal residual apical shunt.


Subject(s)
Cardiac Catheterization/instrumentation , Heart Septal Defects, Ventricular/surgery , Child , Equipment Design , Heart Septal Defects, Ventricular/diagnostic imaging , Humans , Male , Radiography
9.
An. esp. pediatr. (Ed. impr) ; 57(1): 66-69, jul. 2002.
Article in Es | IBECS | ID: ibc-13039

ABSTRACT

Se presenta el caso de un niño de 6 años de edad, afectado de una comunicación interventricular (CIV) muscular residual medioventricular de difícil acceso quirúrgico, en la que se procedió al cierre mediante cateterismo con el dispositivo Amplatzer Muscular VSD Occluder. El procedimiento se realizó guiado por ecocardiografía transtorácica consiguiendo la implantación del dispositivo de 12 mm de tamaño sin incidencias ni complicaciones. A las 24 h el paciente fue dado de alta previa realización de una radiografía de tórax que muestra una disminución importante tanto de la cardiomegalia como de la circulación pulmonar y una ecocardiografía que evidencia el dispositivo correctamente situado en el tabique interventricular sin flujo a su través, y con una CIV residual mínima. Tras un seguimiento de 3 meses el paciente esta asintomático y la ecocardiografía muestra el dispositivo correctamente situado con mínima CIV residual apical (AU)


Subject(s)
Child , Male , Humans , Equipment Design , Heart Septal Defects, Ventricular , Cardiac Catheterization
10.
J Nucl Med ; 42(12): 1768-72, 2001 Dec.
Article in English | MEDLINE | ID: mdl-11752071

ABSTRACT

UNLABELLED: A high number (30%-50%) of reversible defects have been detected early after coronary balloon angioplasty. Inadequate luminal enlargement despite a good angiographic appearance has been suggested as a possible mechanism of these perfusion abnormalities, and some reports have shown better coronary flow reserve after coronary stent implantation than after balloon dilatation. The primary objective of this study was to evaluate the frequency of early ischemic defects detected by maximal exercise (plus dipyridamole) with (99m)Tc-tetrofosmin SPECT after successful coronary angioplasty with stent implantation. A secondary objective was to determine the prognostic value of these early ischemic defects. METHODS: Thirty patients without previous myocardial infarction who successfully underwent 1-vessel coronary angioplasty with stent implantation were studied. Maximal-exercise (99m)Tc-tetrofosmin myocardial SPECT, with simultaneous dipyridamole if exercise was suboptimal, was performed at 6 +/- 1 d (mean +/- SD) after percutaneous transluminal coronary angioplasty. At 8 +/- 3 mo, all patients were followed up clinically, and 77% of them underwent follow-up angiography. RESULTS: The percentage of stenosis decreased from 68.5% +/- 12.6% of luminal diameter to 9.3% +/- 8.8% after stent implantation, and minimal luminal diameter increased from 0.89 +/- 0.36 mm to 2.85 +/- 0.45 mm. Mild-to-moderate reversible myocardial defects in the territory of the dilated artery were detected in 5 patients (17%), with no angiographic or procedural differences occurring between them and patients without ischemic defects. At follow-up, the target lesion revascularization rates depending on the presence or absence of early ischemic defects were 40% and 8%, respectively (P = 0.18). Angiographic restenosis occurred in 3 of 4 patients who had early ischemic defects and underwent follow-up angiography and in 3 of 19 patients who had no early ischemic defects and underwent follow-up angiography (restenosis rate, 75% and 16%, respectively; P < 0.05). CONCLUSION: Coronary angioplasty with stent implantation is associated with a 17% rate of ischemic defects early after the procedure. Patients with early myocardial perfusion defects after coronary stent implantation had a high rate of restenosis.


Subject(s)
Angioplasty, Balloon, Coronary , Myocardial Ischemia/epidemiology , Stents , Coronary Angiography , Coronary Restenosis/epidemiology , Dipyridamole , Exercise Test , Female , Follow-Up Studies , Humans , Incidence , Male , Middle Aged , Myocardial Ischemia/diagnostic imaging , Organophosphorus Compounds , Organotechnetium Compounds , Prognosis , Radiopharmaceuticals , Time Factors , Tomography, Emission-Computed, Single-Photon
11.
Rev Esp Cardiol ; 48(2): 145-7, 1995 Feb.
Article in Spanish | MEDLINE | ID: mdl-7886266

ABSTRACT

The association between Friedreich's ataxia and heart disease is well known. Microvascular disease and spasm of coronary arteries have been reported. We report now a patient with the association between this disease and acute myocardial infarction, which raises the hypothesis that it may be related with the already known cardiac abnormalities in this disease.


Subject(s)
Friedreich Ataxia/etiology , Myocardial Infarction/complications , Cardiac Catheterization , Electrocardiography , Friedreich Ataxia/diagnosis , Humans , Male , Middle Aged , Myocardial Infarction/diagnosis
SELECTION OF CITATIONS
SEARCH DETAIL