Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Language
Publication year range
1.
Med. clín (Ed. impr.) ; 144(10): 445-448, mayo 2015. tab
Article in Spanish | IBECS | ID: ibc-138012

ABSTRACT

Fundamento y objetivo: Testar un nuevo dispositivo de telerrehabilitación para la incontinencia urinaria de esfuerzo (IUE) y hacer una valoración inicial de su eficacia. Pacientes y método: Estudio piloto controlado y aleatorizado en pacientes con IUE. En el grupo experimental (n = 10) la intervención consistió en entrenamiento de la musculatura del suelo pélvico, adiestramiento y tratamiento domiciliario con el dispositivo. En el grupo control (n = 9) se realizó tratamiento rehabilitador convencional. Las medidas de resultados (iniciales y a los 3 meses) fueron la calidad de vida específica y genérica determinada mediante: International Consultation Incontinence Questionnaire y King's Health Questionnaire, diario miccional, perineometría, satisfacción con el programa y grado de cumplimiento. Resultados: Ambos grupos presentaban características basales similares. No hubo diferencias estadísticamente significativas en ninguna medida de resultados entre ambos grupos al final del período de seguimiento. Los valores iniciales y finales de la perineometría del grupo experimental mostraron diferencias con significación estadística (23,06 frente a 32, p = 0,011). No se presentaron efectos adversos graves en ningún grupo. Conclusiones: El dispositivo testado es seguro y bien aceptado. Aunque hay indicios de su eficacia en el tratamiento rehabilitador de la IUE, son necesarios estudios más amplios para valorar adecuadamente sus ventajas (AU)


Background and objective: We aimed to test a new telerehabilitation device for stress urinary incontinence (SUI) in order to make an initial assessment of its effectiveness. Patients and method: Randomized, controlled pilot study. Intervention: experimental group (10 patients): pelvic floor muscle training, device training and home treatment with it; control group (9 patients): conventional rehabilitation treatment. Outcome measures (baseline and 3 months) overall and specific quality of life: International Consultation Incontinence Questionnaire and King's Health Questionnaire, bladder diary, perineometry, satisfaction with the program and degree of compliance. Results: Baseline characteristics were similar in both groups. There was no statistically significant difference for any outcome measures between groups at the end of the follow-up. The change in perineometry values at baseline and after the intervention was significant in the experimental group (23.06 to 32.00, P = .011). No group in this study had any serious adverse effects. Conclusions: The tested device is safe and well accepted. Although there is some evidence of its efficacy in the rehabilitation treatment of SUI, larger trials are needed to appropriately evaluate the potential advantages (AU)


Subject(s)
Humans , Urinary Incontinence, Stress/rehabilitation , Telemedicine/methods , Pelvimetry , Pelvic Floor , Pelvic Floor Disorders/rehabilitation , Quality of Life
2.
Med Clin (Barc) ; 144(10): 445-8, 2015 May 21.
Article in Spanish | MEDLINE | ID: mdl-25087210

ABSTRACT

BACKGROUND AND OBJECTIVE: We aimed to test a new telerehabilitation device for stress urinary incontinence (SUI) in order to make an initial assessment of its effectiveness. PATIENTS AND METHOD: Randomized, controlled pilot study. INTERVENTION: experimental group (10 patients): pelvic floor muscle training, device training and home treatment with it; control group (9 patients): conventional rehabilitation treatment. Outcome measures (baseline and 3 months) overall and specific quality of life: International Consultation Incontinence Questionnaire and King's Health Questionnaire, bladder diary, perineometry, satisfaction with the program and degree of compliance. RESULTS: Baseline characteristics were similar in both groups. There was no statistically significant difference for any outcome measures between groups at the end of the follow-up. The change in perineometry values at baseline and after the intervention was significant in the experimental group (23.06 to 32.00, P=.011). No group in this study had any serious adverse effects. CONCLUSIONS: The tested device is safe and well accepted. Although there is some evidence of its efficacy in the rehabilitation treatment of SUI, larger trials are needed to appropriately evaluate the potential advantages.


Subject(s)
Telerehabilitation/methods , Urinary Incontinence, Stress/rehabilitation , Adult , Biofeedback, Psychology , Exercise Therapy/methods , Female , Follow-Up Studies , Humans , Middle Aged , Patient Compliance , Pilot Projects , Quality of Life , Surveys and Questionnaires , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...