Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Clin Transplant ; 33(8): e13643, 2019 08.
Article in English | MEDLINE | ID: mdl-31225918

ABSTRACT

Reactivation of latent tuberculosis following solid organ transplantation has serious consequences for the recipient. The most useful diagnostic test for latent TB is not clear. We conducted a systematic review and meta-analysis to assess the relative test performance of interferon gamma release assays (IGRAs) and the tuberculin skin test (TST) in people undergoing solid organ transplantation. The clinical or radiological risk factors were used as the proxy reference standard. Test performance was expressed as an odd ratio (OR). We identified 24 studies (N = 7811), 12 studies compared IGRAs with TST directly, nine studies evaluated only TST and three studies only IGRAs. Direct comparison between tests and clinical risk factors indicated both tests were strongly associated with the presence of clinical risk factors for TB (TST: OR 3.17; 95%CI 1.55-6.48, IGRA: OR 2.78; 95%CI 1.55-5.01), and radiological evidence of past TB (TST: OR 3.26; 95%CI 1.85-5.73, IGRA: OR 3.85; 95%CI 2.16-6.86). Relative comparison indicated IGRAs positivity was more strongly associated with presence of radiological evidence of TB than TST (relative OR: 3.24; 95%CI 1.10-9.56). While there is no strong evidence in supporting use of IGRAs over TST for diagnosing latent TB, IGRAs positivity is more associated with the presence of radiological evidence of previous TB.


Subject(s)
Interferon-gamma Release Tests/methods , Latent Tuberculosis/diagnosis , Mycobacterium tuberculosis/isolation & purification , Organ Transplantation/standards , Tissue Donors/statistics & numerical data , Transplant Recipients/statistics & numerical data , Tuberculin Test/methods , Humans
2.
Nephrology (Carlton) ; 20(8): 513-8, 2015 Aug.
Article in English | MEDLINE | ID: mdl-25753254

ABSTRACT

AIM: Nephrologists looking for quick answers to diagnostic clinical questions in MEDLINE can use a range of published search strategies or Clinical Query limits to improve the precision of their searches. We aimed to evaluate existing search strategies for finding diagnostic test accuracy studies in nephrology journals. METHODS: We assessed the accuracy of 14 search strategies for retrieving diagnostic test accuracy studies from three nephrology journals indexed in MEDLINE. Two investigators hand searched the same journals to create a reference set of diagnostic test accuracy studies to compare search strategy results against. RESULTS: We identified 103 diagnostic test accuracy studies, accounting for 2.1% of all studies published. The most specific search strategy was the Narrow Clinical Queries limit (sensitivity: 0.20, 95% CI 0.13-0.29; specificity: 0.99, 95% CI 0.99-0.99). Using the Narrow Clinical Queries limit, a searcher would need to screen three (95% CI 2-6) articles to find one diagnostic study. The most sensitive search strategy was van der Weijden 1999 Extended (sensitivity: 0.95; 95% CI 0.89-0.98; specificity 0.55, 95% CI 0.53-0.56) but required a searcher to screen 24 (95% CI 23-26) articles to find one diagnostic study. Bachmann 2002 was the best balanced search strategy, which was sensitive (0.88, 95% CI 0.81-0.94), but also specific (0.74, 95% CI 0.73-0.75), with a number needed to screen of 15 (95% CI 14-17). CONCLUSION: Diagnostic studies are infrequently published in nephrology journals. The addition of a strategy for diagnostic studies to a subject search strategy in MEDLINE may reduce the records needed to screen while preserving adequate search sensitivity for routine clinical use.


Subject(s)
Data Mining/methods , Kidney Function Tests , MEDLINE , Periodicals as Topic , Bibliometrics , Humans , Predictive Value of Tests , Reproducibility of Results
3.
J Paediatr Child Health ; 49(4): 319-24, 2013 Apr.
Article in English | MEDLINE | ID: mdl-23530924

ABSTRACT

AIM: Systematic reviews have the potential to map those areas where children are under-represented in surgical research. We aimed to describe and evaluate the quantity, coverage and the quality of conduct and reporting of systematic reviews of surgical procedures in children. METHODS: We searched four biomedical databases, a systematic review register, reference lists and conducted hand searching to identify relevant reviews. Two reviewers worked independently to critically appraise included studies and abstract data. We assessed reporting quality using the preferred reporting items for systematic reviews and meta-analysis statement and methodological quality using the Assessment of Multiple SysTemAtic Reviews tool. RESULTS: Fifteen systematic reviews were identified, representing 0.01% of all paediatric surgical citations in MEDLINE and Embase. Thirteen of the reviews were Cochrane reviews, and most reviews (12/15) addressed subspecialty interests such as otorhinolaryngology. The median number of included trials per systematic review was four (interquartile range 1 to 9.5), the median number of primary outcomes was 5.5 (interquartile range 3.5 to 7.5). In general, reporting and methodological quality was good although there were several omissions, particularly around completeness of reporting of statistical methods used, and utilisation of quality assessments in analyses. Outcomes were often not clearly defined and descriptions of procedures lacked sufficient detail to determine the similarities and differences among surgical procedures within the contributing trials. CONCLUSION: Systematic reviews of surgical procedures in children are rarely published. To improve the evidence base and guide research agendas, more systematic reviews should be conducted, using standard guidelines for conduct and reporting.


Subject(s)
Quality of Health Care/standards , Surgical Equipment/standards , Surgical Procedures, Operative/statistics & numerical data , Child , Humans , Review Literature as Topic , Surgical Procedures, Operative/standards
4.
Am J Kidney Dis ; 61(1): 33-43, 2013 Jan.
Article in English | MEDLINE | ID: mdl-23068425

ABSTRACT

BACKGROUND: The relative diagnostic accuracy of interferon γ release assays (IGRAs; based on ELISA [enzyme-linked immunosorbent assay] or ELISPOT [enzyme-linked immunosorbent spot], ie, the QuantiFERON and T-SPOT.TB tests, respectively) and the tuberculin skin test (TST) for latent tuberculosis (TB) infection in people with end-stage kidney disease is uncertain and national guidelines for their use are inconsistent. STUDY DESIGN: Systematic review. SELECTION CRITERIA FOR STUDIES: Evaluated performance of tests for latent TB with clinical risk-factor assessment. SETTING & POPULATION: People with end-stage kidney disease (chronic kidney disease stage 5 [eGFR <15] or kidney transplant recipients). No limits on setting. INDEX TESTS: ELISA- or ELISPOT-based IGRAs, TST, assays to detect antimycobacterial antibodies, and flow cytometry-based tests. OUTCOMES: Odds of test positivity with clinical risk factor for latent TB, expressed as ORs and relative ORs (RORs). RESULTS: 47 studies (6,828 participants) were included, but only 30 studies (4,546 participants) contained sufficient data to contribute to meta-analysis. Studies were predominately in the dialysis population (23/30; 3,700 participants) in countries with low to moderate TB prevalence (0.0-50.0 cases/10(5) persons). BCG vaccination rate was variable (2.7%-100.0%). 9 studies compared IGRAs with the TST directly, 17 studies evaluated the TST only, and the other 4 studies evaluated other tests. Compared to a positive TST result, a positive ELISA-based IGRA result was associated more strongly with radiologic evidence of past TB (ROR, 4.29; 95% CI, 1.83-10.3; P = 0.001) and contact with active TB (ROR, 3.36; 95% CI, 1.61-7.01; P = 0.001). Compared to a negative TST result, a negative ELISA-based IGRA result was associated more strongly with BCG vaccination (ROR, 0.30; 95% CI, 0.14-0.63; P = 0.002). There were insufficient data to compare performance of the ELISPOT-based IGRA with the TST or ELISA-based IGRA. LIMITATIONS: 17 of 47 included studies (36.2%) did not contain sufficient data to contribute to meta-analysis. CONCLUSIONS: Compared to the TST, the ELISA-based IGRA was associated more strongly with risk factors for latent TB in end-stage kidney disease.


Subject(s)
Kidney Failure, Chronic/epidemiology , Latent Tuberculosis/diagnosis , Latent Tuberculosis/epidemiology , Mass Screening/methods , Adult , Aged , Comorbidity , Enzyme-Linked Immunospot Assay , Female , Humans , Interferon-gamma/blood , Latent Tuberculosis/blood , Male , Middle Aged , Risk Factors , Sensitivity and Specificity , Tuberculin Test
5.
Med J Aust ; 196(4): 256-60, 2012 Mar 05.
Article in English | MEDLINE | ID: mdl-22409692

ABSTRACT

OBJECTIVE: To describe the frequency, characteristics and outcomes of reports of possible harms related to medical devices submitted to the Australian Therapeutic Goods Administration (TGA) using data made publicly available on the TGA website. DESIGN AND SETTING: A retrospective analysis, conducted in January 2012, of data made publicly available on the TGA website from January 2000 to December 2011. MAIN OUTCOME MEASURES: The number and nature of reports of medical device incidents, recalls and alerts. RESULTS: Up to December 2011, 6812 incidents involving medical devices were reported to the TGA, although there were several periods where data were unavailable. Incidents were reported more frequently in later years, most often by device sponsors, and were often attributed to mechanical problems. 295 deaths and 2357 serious injuries have been related to incidents, with serious injury (597) highest in 2009. Most incidents involving medical devices were not investigated (47.5%), or, after investigation, no further action was taken (25.0%). During the same time period, there were 35 medical device recalls and 34 medical device alerts issued by the TGA, with no consistent increase over time. CONCLUSIONS: Despite TGA reform proposals, greater transparency is still needed. Issues that have not been addressed include patchy and conflicting data in the public domain and lack of explanations for the large proportion of uninvestigated reports. To maintain public confidence in the national regulatory system these problems need to be resolved.


Subject(s)
Equipment and Supplies/standards , Medical Device Recalls/legislation & jurisprudence , Product Surveillance, Postmarketing , Australia , Consumer Product Safety/legislation & jurisprudence , Databases, Factual , Equipment Design , Equipment Safety , Female , Humans , Male , Medical Errors/statistics & numerical data , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...