Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
2.
Antimicrob Agents Chemother ; 56(2): 725-30, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22083473

ABSTRACT

Scant data exist for the pharmacokinetics (PK) of ertapenem in patients on continuous ambulatory peritoneal dialysis (CAPD). The goals of this study were to characterize the PK profile of ertapenem during CAPD, determine the extent of ertapenem penetration into the peritoneal cavity, and quantify the probability of the target attainment (PTA) profile in the serum and peritoneal cavity. A single-dose PK study was conducted in seven patients on CAPD. Population PK modeling and Monte Carlo simulation determined the probability that ertapenem at 500 mg intravenously (i.v.) every 24 h (q24h) would achieve concentrations in excess of the MIC for 40% of the dosing interval (40% T>MIC, where T is time) in the serum and peritoneal cavity. Monte Carlo simulation was also used to calculate the peritoneal cavity/serum mean and median penetration ratios by estimating the area under the concentration-time curve in the peritoneal cavity and serum (AUC(Peritoneal) and AUC(Serum), respectively) from zero to infinity after a single simulated dose. The population mean (± standard deviation [SD]) values for the apparent volume in the central compartment, clearance, and apparent volume in the peritoneal cavity were 2.78 (0.62) liters, 0.24 (0.07) liters/hr, and 5.81 (2.05) liters, respectively. The mean (SD) AUC(Peritoneal)/AUC(Serum) ratio was 1.039 (0.861), and the median penetration ratio was 0.801 (interquartile range, 0.486 to 1.317). In both the serum and peritoneal cavity, ertapenem at 500 mg i.v. q24h was very likely (>90%) to achieve the pharmacodynamic target for MICs of ≤2 mg/liter. The simulations suggest that 500 mg of ertapenem i.v. q24h is very likely to achieve the exposure target associated with clinical efficacy in both the serum and peritoneal cavity against the range of MIC values deemed susceptible by the Clinical and Laboratory Standards Institute.


Subject(s)
Anti-Bacterial Agents/administration & dosage , Anti-Bacterial Agents/pharmacokinetics , Peritoneal Dialysis, Continuous Ambulatory/methods , beta-Lactams/administration & dosage , beta-Lactams/pharmacokinetics , Adult , Aged , Anti-Bacterial Agents/blood , Anti-Bacterial Agents/urine , Area Under Curve , Chromatography, High Pressure Liquid , Ertapenem , Female , Humans , Male , Microbial Sensitivity Tests , Middle Aged , Models, Biological , Monte Carlo Method , Peritoneal Cavity/physiology , Urine/chemistry , beta-Lactams/blood , beta-Lactams/urine
SELECTION OF CITATIONS
SEARCH DETAIL
...