Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Article in English | MEDLINE | ID: mdl-38696210

ABSTRACT

Importance: Ethanol ablation (EA) was shown to be safe and effective for treating ranula, but few studies have assessed long-term outcomes and recurrence of ranula after EA. Objective: To evaluate the long-term outcomes and the risk factors for recurrence and receipt of subsequent surgery in patients who underwent treatment with EA for ranula. Design, Setting, and Participants: This case-series study was conducted at a single tertiary hospital and assessed patients who were treated with EA between July 2009 and March 2021. Among 70 consecutive patients, those with follow-up loss or who were followed up for less than 24 months were excluded. Exposures: EA for ranula. Main Outcomes and Measures: The primary outcome was recurrence at last follow-up after single or multiple EA sessions. Secondary outcomes included receipt of subsequent surgery and the recurrence-free survival (RFS) rate after initial EA. Factors possibly associated with outcomes included patient age and sex; ranula site, type, diameter, volume, and echogenicity; the presentation-to-EA interval; parapharyngeal space extension; and sublingual gland herniation. Risk factors were identified on logistic regression analyses. Two-year RFS rates were analyzed for the initial cohort using the Kaplan-Meier method and compared by log-rank tests. Results: A total of 57 patients (mean [SD] age, 26.4 [12.1] years; 24 female individuals [42%]) who were followed up for a median of 57 months (range, 24-167 months) were included. The recurrence rate was 33% (n = 19), and 11 (19%) underwent subsequent surgery. Among patients with recurrence, 86% (31 of 36) experienced first recurrence within 12 months after initial EA. A presentation-to-EA interval of 12 months or longer was associated with an increased risk of recurrence (adjusted odds ratio [OR], 3.74; 95% CI, 1.01-13.82). No risk factors were significantly associated with subsequent surgery (highest OR in parapharyngeal space extension: adjusted OR, 4.96; 95% CI, 0.94-26.35). Among the initial cohort of 70 patients, 2-year RFS was lower in a maximum diameter of ranula of 5 cm or greater than less than 5 cm (24% [95% CI, 7%-41%] vs 50% [95% CI, 34%-66%]; difference, 26% [95% CI, -4% to 56%]; log-rank test, P = .02). Conclusions and Relevance: This case-series study found that the recurrence rate of ranula after EA was 33%. A presentation-to-EA interval of 12 months or longer may be a risk factor for recurrence, suggesting that early intervention with EA might minimize recurrence. Most first recurrences occurred within 12 months after EA, with a maximum diameter of ranula of 5 cm or greater being a possible risk factor.

2.
Korean J Radiol ; 25(4): 374-383, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38528695

ABSTRACT

OBJECTIVE: To evaluate the diagnostic performance and image quality of 1.5-mm slice thickness MRI with deep learning-based image reconstruction (1.5-mm MRI + DLR) compared to routine 3-mm slice thickness MRI (routine MRI) and 1.5-mm slice thickness MRI without DLR (1.5-mm MRI without DLR) for evaluating temporal lobe epilepsy (TLE). MATERIALS AND METHODS: This retrospective study included 117 MR image sets comprising 1.5-mm MRI + DLR, 1.5-mm MRI without DLR, and routine MRI from 117 consecutive patients (mean age, 41 years; 61 female; 34 patients with TLE and 83 without TLE). Two neuroradiologists evaluated the presence of hippocampal or temporal lobe lesions, volume loss, signal abnormalities, loss of internal structure of the hippocampus, and lesion conspicuity in the temporal lobe. Reference standards for TLE were independently constructed by neurologists using clinical and radiological findings. Subjective image quality, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were analyzed. Performance in diagnosing TLE, lesion findings, and image quality were compared among the three protocols. RESULTS: The pooled sensitivity of 1.5-mm MRI + DLR (91.2%) for diagnosing TLE was higher than that of routine MRI (72.1%, P < 0.001). In the subgroup analysis, 1.5-mm MRI + DLR showed higher sensitivity for hippocampal lesions than routine MRI (92.7% vs. 75.0%, P = 0.001), with improved depiction of hippocampal T2 high signal intensity change (P = 0.016) and loss of internal structure (P < 0.001). However, the pooled specificity of 1.5-mm MRI + DLR (76.5%) was lower than that of routine MRI (89.2%, P = 0.004). Compared with 1.5-mm MRI without DLR, 1.5-mm MRI + DLR resulted in significantly improved pooled accuracy (91.2% vs. 73.1%, P = 0.010), image quality, SNR, and CNR (all, P < 0.001). CONCLUSION: The use of 1.5-mm MRI + DLR enhanced the performance of MRI in diagnosing TLE, particularly in hippocampal evaluation, because of improved depiction of hippocampal abnormalities and enhanced image quality.


Subject(s)
Deep Learning , Epilepsy, Temporal Lobe , Humans , Female , Adult , Epilepsy, Temporal Lobe/diagnostic imaging , Epilepsy, Temporal Lobe/pathology , Epilepsy, Temporal Lobe/surgery , Retrospective Studies , Magnetic Resonance Imaging/methods , Image Processing, Computer-Assisted
4.
Cancer Imaging ; 23(1): 102, 2023 Oct 24.
Article in English | MEDLINE | ID: mdl-37875970

ABSTRACT

BACKGROUND: Accurate response parameters are important for patients with brain metastasis (BM) undergoing clinical trials using immunotherapy, considering poorly defined enhancement and variable responses. This study investigated MRI-based surrogate endpoints for patients with BM receiving immunotherapy. METHODS: Sixty-three non-small cell lung cancer patients with BM who received immune checkpoint inhibitors and underwent MRI were included. Tumor diameters were measured using a modification of the RECIST 1.1 (mRECIST), RANO-BM, and iRANO adjusted for BM (iRANO-BM). Tumor volumes were segmented on 3D contrast-enhanced T1-weighted imaging. Differences between the sum of the longest diameter (SLD) or total tumor volume at baseline and the corresponding measurement at time of the best overall response were calculated as "changes in SLDs" (for each set of criteria) and "change in volumetry," respectively. Overall response rate (ORR), progressive disease (PD) assignment, and progression-free survival (PFS) were compared among the criteria. The prediction of overall survival (OS) was compared between diameter-based and volumetric change using Cox proportional hazards regression analysis. RESULTS: The mRECIST showed higher ORR (30.1% vs. both 17.5%) and PD assignment (34.9% vs. 25.4% [RANO-BM] and 19% [iRANO-BM]). The iRANO-BM had a longer median PFS (13.7 months) than RANO-BM (9.53 months) and mRECIST (7.73 months, P = 0.003). The change in volumetry was a significant predictor of OS (HR = 5.87, 95% CI: 1.46-23.64, P = 0.013). None of the changes in SLDs, as determined by RANO-BM or iRANO-BM, were significant predictors of OS, except for the mRECIST, which exhibited a weak association with OS. CONCLUSION: Quantitative volume measurement may be an accurate surrogate endpoint for OS in patients with BM undergoing immunotherapy, especially considering the challenges of multiplicity and the heterogeneity of sub-centimeter size responses.


Subject(s)
Brain Neoplasms , Carcinoma, Non-Small-Cell Lung , Lung Neoplasms , Humans , Carcinoma, Non-Small-Cell Lung/diagnostic imaging , Carcinoma, Non-Small-Cell Lung/drug therapy , Prognosis , Immune Checkpoint Inhibitors/therapeutic use , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/drug therapy , Brain Neoplasms/diagnostic imaging , Brain Neoplasms/drug therapy , Magnetic Resonance Imaging , Retrospective Studies
5.
Korean J Radiol ; 24(10): 1028-1037, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37793671

ABSTRACT

OBJECTIVE: To evaluate the computed tomography (CT) features for diagnosing metastatic cervical lymph nodes (LNs) in patients with differentiated thyroid cancer (DTC) and validate the CT-based risk stratification system suggested by the Korean Thyroid Imaging Reporting and Data System (K-TIRADS) guidelines. MATERIALS AND METHODS: A total of 463 LNs from 399 patients with DTC who underwent preoperative CT staging and ultrasound-guided fine-needle aspiration were included. The following CT features for each LN were evaluated: absence of hilum, cystic changes, calcification, strong enhancement, and heterogeneous enhancement. Multivariable logistic regression analysis was performed to identify independent CT features associated with metastatic LNs, and their diagnostic performances were evaluated. LNs were classified into probably benign, indeterminate, and suspicious categories according to the K-TIRADS and the modified LN classification proposed in our study. The diagnostic performance of both classification systems was compared using the exact McNemar and Kosinski tests. RESULTS: The absence of hilum (odds ratio [OR], 4.859; 95% confidence interval [CI], 1.593-14.823; P = 0.005), strong enhancement (OR, 28.755; 95% CI, 12.719-65.007; P < 0.001), and cystic changes (OR, 46.157; 95% CI, 5.07-420.234; P = 0.001) were independently associated with metastatic LNs. All LNs showing calcification were diagnosed as metastases. Heterogeneous enhancement did not show a significant independent association with metastatic LNs. Strong enhancement, calcification, and cystic changes showed moderate to high specificity (70.1%-100%) and positive predictive value (PPV) (91.8%-100%). The absence of the hilum showed high sensitivity (97.8%) but low specificity (34.0%). The modified LN classification, which excluded heterogeneous enhancement from the K-TIRADS, demonstrated higher specificity (70.1% vs. 62.9%, P = 0.016) and PPV (92.5% vs. 90.9%, P = 0.011) than the K-TIRADS. CONCLUSION: Excluding heterogeneous enhancement as a suspicious feature resulted in a higher specificity and PPV for diagnosing metastatic LNs than the K-TIRADS. Our research results may provide a basis for revising the LN classification in future guidelines.


Subject(s)
Thyroid Neoplasms , Humans , Lymphatic Metastasis/diagnostic imaging , Lymphatic Metastasis/pathology , Thyroid Neoplasms/diagnostic imaging , Thyroid Neoplasms/surgery , Thyroid Neoplasms/pathology , Lymph Nodes/diagnostic imaging , Lymph Nodes/pathology , Tomography, X-Ray Computed , Risk Assessment , Retrospective Studies
6.
J Neurointerv Surg ; 2023 Sep 22.
Article in English | MEDLINE | ID: mdl-37739793

ABSTRACT

BACKGROUND: We aimed to investigate the radiation dose to the eye lens (lens dose) during cerebral angiography and to evaluate the effectiveness of the lens dose reduction protocol for 3-dimensional rotational angiography (3D-RA) in reducing overall lens dose exposure. METHODS: We conducted a randomized, controlled clinical trial at a tertiary hospital with patients undergoing cerebral angiography. The lens dose reduction protocol in 3D-RA involved raising the table to position the patient's eye lens away from the rotation axis. The lens dose was estimated by measuring the entrance surface air kerma using a photoluminescent glass dosimeter. The lens doses of 3D-RA, overall examination, and image quality were analyzed and compared between the two groups. RESULTS: A total of 20 participants (mean age, 58±9.4 years; including 12 men [60%]) were enrolled and randomly assigned to either the conventional group or the dose reduction group. The median lens dose in 3D-RA was significantly lower in the dose reduction group compared with the conventional group (1.1 mGy vs 4.5 mGy, p<0.001). The total dose was significantly lower in the dose reduction group (median of 7.5 mGy vs 10.2 mGy, p=0.003). In the conventional group, 3D-RA accounted for 46% of the total lens dose, while in the dose reduction group, its proportion decreased to 16%. No significant differences were observed in the image quality between the groups. CONCLUSION: The lens dose reduction protocol resulted in a significant reduction in the lens dose of the 3D-RA as well as entire cerebral angiography, while maintaining the image quality.

7.
Korean J Radiol ; 24(7): 681-689, 2023 07.
Article in English | MEDLINE | ID: mdl-37404110

ABSTRACT

OBJECTIVE: Three-dimensional rotational angiography (3D-RA) is increasingly used for the evaluation of intracranial aneurysms (IAs); however, radiation exposure to the lens is a concern. We investigated the effect of head off-centering by adjusting table height on the lens dose during 3D-RA and its feasibility in patient examination. MATERIALS AND METHODS: The effect of head off-centering during 3D-RA on the lens radiation dose at various table heights was investigated using a RANDO head phantom (Alderson Research Labs). We prospectively enrolled 20 patients (58.0 ± 9.4 years) with IAs who were scheduled to undergo bilateral 3D-RA. In all patients' 3D-RA, the lens dose-reduction protocol involving elevation of the examination table was applied to one internal carotid artery, and the conventional protocol was applied to the other. The lens dose was measured using photoluminescent glass dosimeters (GD-352M, AGC Techno Glass Co., LTD), and radiation dose metrics were compared between the two protocols. Image quality was quantitatively analyzed using source images for image noise, signal-to-noise ratio, and contrast-to-noise ratio. Additionally, three reviewers qualitatively assessed the image quality using a five-point Likert scale. RESULTS: The phantom study showed that the lens dose was reduced by an average of 38% per 1 cm increase in table height. In the patient study, the dose-reduction protocol (elevating the table height by an average of 2.3 cm) led to an 83% reduction in the median dose from 4.65 mGy to 0.79 mGy (P < 0.001). There were no significant differences between dose-reduction and conventional protocols in the kerma area product (7.34 vs. 7.40 Gy·cm², P = 0.892), air kerma (75.7 vs. 75.1 mGy, P = 0.872), and image quality. CONCLUSION: The lens radiation dose was significantly affected by table height adjustment during 3D-RA. Intentional head off-centering by elevation of the table is a simple and effective way to reduce the lens dose in clinical practice.


Subject(s)
Intracranial Aneurysm , Lens, Crystalline , Humans , Prospective Studies , Radiation Dosage , Cerebral Angiography/methods , Intracranial Aneurysm/diagnostic imaging , Phantoms, Imaging
8.
Korean J Radiol ; 22(12): 2026-2033, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34564962

ABSTRACT

OBJECTIVE: The aim of this study was to compare the diagnostic performances of digital tomosynthesis (DTS) and conventional radiography in detecting osteonecrosis of the femoral head (ONFH) using computed tomography (CT), as the reference standard and evaluate the diagnostic reproducibility of DTS. MATERIALS AND METHODS: Forty-five patients (24 male and 21 female; age range, 25-77 years) with clinically suspected ONFH underwent anteroposterior radiography, DTS, and CT. Two musculoskeletal radiologists independently evaluated the presence and type of ONFH. The diagnostic performance of radiography and DTS in detecting the presence of ONFH and determining the types of ONFH were evaluated. The interobserver and intraobserver reliabilities of each imaging modality were analyzed using Cohen's kappa. RESULTS: DTS had higher sensitivity (89.4%-100% vs. 74.5%-76.6%) and specificity (97.3%-100% vs. 78.4%-83.8%) for ONFH detection than radiography. DTS showed higher performance than radiography in identifying the subtypes of ONFH with statistical significance in one reader (type 1, 100% vs. 30.8%, p = 0.004; type II, 97.1% vs. 73.5%, p = 0.008). The interobserver agreement was excellent for DTS and moderate for radiography (kappa of 0.86 vs. 0.57, respectively). The intraobserver agreement for DTS was higher than that of radiography (kappa of 0.96 vs. 0.69, respectively). CONCLUSION: DTS showed higher diagnostic performance and reproducibility than radiography in detecting ONFH. DTS may be used as a first-line diagnostic modality instead of radiography for patients suspected of having ONFH.


Subject(s)
Femur Head , Osteonecrosis , Adult , Aged , Female , Femur Head/diagnostic imaging , Humans , Male , Middle Aged , Radiographic Image Enhancement , Radiography , Reproducibility of Results
9.
Sci Rep ; 11(1): 13616, 2021 06 30.
Article in English | MEDLINE | ID: mdl-34193951

ABSTRACT

Low cut-off of FIB-4 is a widely used formula to exclude advanced liver fibrosis in primary care centers. However, the range of reported threshold of FIB-4 to rule in advanced fibrosis is too broad across etiologies, and no consensus has been reached. In the present study, we investigated the role of FIB-4 for a reassessment of hepatic fibrosis burden in a referral center. We compared the diagnostic performance of FIB-4 among patients with liver disease of various causes and tried to find an optimal cut-off value for predicting advanced fibrosis. Among 1068 patients, the AUROC of FIB-4 to diagnose advanced fibrosis showed no significant difference among the various etiologies of liver disease, ranging from 0.783 to 0.821. The optimal cut-off value obtained by maximizing Youden's index was 2.68, and the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for predicting advanced fibrosis were 70.7%, 79.1%, 43.5%, and 92.2%, respectively. The PPV was low in patients with autoimmune disease (6.67%). When we incorporated the new cut-off of FIB-4 into abdominal ultrasound findings, 81% of unnecessary work-ups would be appropriately avoided. In conclusion, the cut-off value of 2.68 showed an acceptable PPV while maintaining a high NPV to predict advanced fibrosis, most etiology except for autoimmune diseases. This result could assist in establishing an appropriate timing to reassess the hepatic fibrosis burden during monitoring in the referral center.


Subject(s)
Cost of Illness , Liver Cirrhosis , Referral and Consultation , Adult , Aged , Cross-Sectional Studies , Female , Humans , Liver Cirrhosis/diagnosis , Liver Cirrhosis/drug therapy , Liver Cirrhosis/pathology , Male , Middle Aged , Retrospective Studies
10.
PLoS One ; 15(12): e0243515, 2020.
Article in English | MEDLINE | ID: mdl-33270774

ABSTRACT

Postoperative pancreatic fistula (POPF) is a common complication following pancreaticoduodenectomy (PD). However, risk factors for this complication remain controversial. We conducted a retrospective analysis of 107 patients who underwent PD. POPF was diagnosed in strict accordance with the definition of the 2016 update of pancreatic fistula from the International Study Group on Pancreatic Fistula (ISGPF). Univariate and multivariate logistic regression analyses were performed to identify independent risk factors for POPF. A total of 19 (17.8%) subjects of pancreatic fistula occurred after PD, including 15 (14.1%) with grade B POPF and 4 (3.7%) with grade C POPF. There were 33 (30.8%) patients with biochemical leak. Risk factors for POPF (grade B and C) were larger area of visceral fat (odds ratio [OR], 1.40; p = 0.040) and pathology other than pancreatic adenocarcinoma or pancreatitis (OR, 12.45; p = 0.017) in the multivariate regression analysis. This result could assist the surgeon to identify patients at a high risk of developing POPF.


Subject(s)
Pancreatic Fistula/etiology , Pancreaticoduodenectomy/adverse effects , Tomography, X-Ray Computed/adverse effects , Adenocarcinoma/pathology , Adult , Aged , Aged, 80 and over , Female , Humans , Logistic Models , Male , Middle Aged , Odds Ratio , Pancreas/surgery , Pancreatectomy/adverse effects , Pancreatic Ducts/pathology , Pancreatic Fistula/diagnosis , Pancreatic Fistula/physiopathology , Pancreatic Neoplasms/pathology , Pancreaticoduodenectomy/methods , Pancreaticoduodenectomy/mortality , Pancreatitis/etiology , Postoperative Complications/etiology , Postoperative Period , Retrospective Studies , Risk Assessment , Risk Factors , Pancreatic Neoplasms
SELECTION OF CITATIONS
SEARCH DETAIL
...