Article in English | MEDLINE | ID: mdl-38918266

ABSTRACT

Pulmonary artery stenosis (PAS) often presents in children with congenital heart disease, altering blood flow and pressure during critical periods of growth and development. Variability in stenosis onset, duration, and severity result in variable growth and remodeling of the pulmonary vasculature. Computational fluid dynamics (CFD) models enable investigation into the hemodynamic impact and altered mechanics associated with PAS. In this study, a one-dimensional (1D) fluid dynamics model was used to simulate hemodynamics throughout the pulmonary arteries of individual animals. The geometry of the large pulmonary arteries was prescribed by animal-specific imaging, whereas the distal vasculature was simulated by a three-element Windkessel model at each terminal vessel outlet. Remodeling of the pulmonary vasculature, which cannot be measured in vivo, was estimated via model-fitted parameters. The large artery stiffness was significantly higher on the left side of the vasculature in the left pulmonary artery (LPA) stenosis group, but neither side differed from the sham group. The sham group exhibited a balanced distribution of total distal vascular resistance, whereas the left side was generally larger in the LPA stenosis group, with no significant differences between groups. In contrast, the peripheral compliance on the right side of the LPA stenosis group was significantly greater than the corresponding side of the sham group. Further analysis indicated the underperfused distal vasculature likely moderately decreased in radius with little change in stiffness given the increase in thickness observed with histology. Ultimately, our model enables greater understanding of pulmonary arterial adaptation due to LPA stenosis and has potential for use as a tool to noninvasively estimate remodeling of the pulmonary vasculature.

4.
J Biomech Eng ; 146(7)2024 07 01.
Article in English | MEDLINE | ID: mdl-38511303

ABSTRACT

Lowery urinary tract symptoms (LUTS) affect a large majority of the aging population. 3D Dynamic MRI shows promise as a noninvasive diagnostic tool that can assess bladder anatomy and function (urodynamics) while overcoming challenges associated with current urodynamic assessment methods. However, validation of this technique remains an unmet need. In this study, an anatomically realistic, bladder-mimicking in vitro flow model was created and used to systematically benchmark 3D dynamic MRI performance using a highly controllable syringe pump. Time-resolved volumes of the synthetic bladder model were obtained during simulated filling and voiding events and used to calculate volumetric flowrate. During MRI acquisitions, pressure during each event was recorded and used to create PV loops for work assessment. Error between control and MRI-derived volume for voiding and filling events exhibited 3.36% and 4.66% differences, respectively. A slight increase in average error was observed for MRI-derived flowrate when compared to the control flowrate (4.90% and 7.67% for voiding and filling, respectively). Overall, average error in segmented volumes increased with decreasing volume flowrate. Pressure drops were observed during voiding. Pressure increased during filling. Enhanced validation of novel 3D MRI urodynamics is achieved by using high-resolution PIV for visualizing and quantifying velocity inside the bladder model, which is not currently possible with 3D Dynamic MRI.


Subject(s)
Urinary Bladder , Urodynamics , Urinary Bladder/diagnostic imaging , Magnetic Resonance Imaging
5.
Am J Physiol Heart Circ Physiol ; 326(5): H1117-H1123, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38488518

ABSTRACT

Noncritical aortic coarctation (COA) typically presents beyond early childhood with hypertension. Correction of COA does not ensure a return to normal cardiovascular health, but the mechanisms are poorly understood. Therefore, we developed a porcine COA model to study the secondary cardiovascular changes. Eight male neonatal piglets (4 sham, 4 COA) underwent left posterolateral thoracotomy with descending aorta (DAO) mobilization. COA was created via a 1-cm longitudinal DAO incision with suture closure, plication, and placement and an 8-mm external band. All animals had cardiac catheterization at 6 (11-13 kg), 12 (26-31 kg), and 20 (67-70 kg) wk of age. Aortic luminal diameters were similar along the thoracic aorta, except for the COA region [6.4 mm COA vs. 17.3 mm sham at 20 wk (P < 0.001)]. Collateral flow could be seen as early as 6 wk. COA peak systolic pressure gradient was 20 mmHg at 6 wk and persisted through 20 wk increasing to 40 mmHg with dobutamine. Pulse pressures distal to the COA were diminished at 12 and 20 wk. This model addresses many limitations of prior COA models including neonatal creation at an expected anatomic position with intimal injury and vessel sizes similar to humans.NEW & NOTEWORTHY A neonatal model of aortic coarctation was developed in a porcine model using a readily reproducible method of aortic plication and external wrap placement. This model addresses the limitations of existing models including neonatal stenosis creation, appropriate anatomic location of the stenosis, and intimal injury creation and mimics human somatic growth. Pigs met American Heart Association (AHA) criteria for consideration of intervention, and the stenoses were graded as moderate to severe.


Subject(s)
Aortic Coarctation , Hypertension , Humans , Child, Preschool , Infant, Newborn , Male , Animals , Swine , Aortic Coarctation/surgery , Constriction, Pathologic/complications , Aorta, Thoracic/surgery , Aorta
6.
Int Urol Nephrol ; 56(3): 893-899, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37823972

ABSTRACT

INTRODUCTION: Dynamic volumetric MRI was used to non-invasively assess voiding biomechanics in a healthy male volunteer. METHODS: Using 3D Differential Subsampling with Cartesian Ordering (DISCO) Flex acquisition sequence, volumetric bladder images were obtained throughout the voiding effort. These were subsequently segmented using MIMICS. Segmented anatomical volumes were used to quantify total voided volume, post-void residual, volumetric displacement of urine over time, bladder neck angle, sphericity index, and prostatic urethral angle through the voiding effort. RESULTS: Bladder sphericity index correlated positively with flow rate. The greatest degree of bladder neck funneling correlated with the maximum urine flow rate. There was straightening of the prostatic urethral angle during voiding that also correlated positively with urine flow. CONCLUSION: This pilot study confirms the potential of dynamic MRI to provide non-invasive assessment of lower urinary tract anatomy and biomechanics during voiding.


Subject(s)
Urinary Bladder Neck Obstruction , Urodynamics , Humans , Male , Pilot Projects , Biomechanical Phenomena , Feasibility Studies , Magnetic Resonance Imaging
8.
J Cardiovasc Magn Reson ; 25(1): 40, 2023 07 20.
Article in English | MEDLINE | ID: mdl-37474977

ABSTRACT

Hemodynamic assessment is an integral part of the diagnosis and management of cardiovascular disease. Four-dimensional cardiovascular magnetic resonance flow imaging (4D Flow CMR) allows comprehensive and accurate assessment of flow in a single acquisition. This consensus paper is an update from the 2015 '4D Flow CMR Consensus Statement'. We elaborate on 4D Flow CMR sequence options and imaging considerations. The document aims to assist centers starting out with 4D Flow CMR of the heart and great vessels with advice on acquisition parameters, post-processing workflows and integration into clinical practice. Furthermore, we define minimum quality assurance and validation standards for clinical centers. We also address the challenges faced in quality assurance and validation in the research setting. We also include a checklist for recommended publication standards, specifically for 4D Flow CMR. Finally, we discuss the current limitations and the future of 4D Flow CMR. This updated consensus paper will further facilitate widespread adoption of 4D Flow CMR in the clinical workflow across the globe and aid consistently high-quality publication standards.


Subject(s)
Cardiovascular System , Humans , Blood Flow Velocity , Predictive Value of Tests , Heart , Magnetic Resonance Imaging , Magnetic Resonance Spectroscopy
10.
Magn Reson Imaging Clin N Am ; 31(3): 433-449, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37414470

ABSTRACT

4D Flow MRI is an advanced imaging technique for comprehensive non-invasive assessment of the cardiovascular system. The capture of the blood velocity vector field throughout the cardiac cycle enables measures of flow, pulse wave velocity, kinetic energy, wall shear stress, and more. Advances in hardware, MRI data acquisition and reconstruction methodology allow for clinically feasible scan times. The availability of 4D Flow analysis packages allows for more widespread use in research and the clinic and will facilitate much needed multi-center, multi-vendor studies in order to establish consistency across scanner platforms and to enable larger scale studies to demonstrate clinical value.


Subject(s)
Magnetic Resonance Imaging , Pulse Wave Analysis , Humans , Magnetic Resonance Imaging/methods , Blood Flow Velocity , Heart , Imaging, Three-Dimensional
11.
Magn Reson Med ; 90(2): 444-457, 2023 08.
Article in English | MEDLINE | ID: mdl-37036023

ABSTRACT

PURPOSE: This study addresses the challenges in obtaining abdominal 4D flow MRI of obese patients. We aimed to evaluate spectral saturation and inner volume excitation as methods to mitigating artifacts originating from adipose signals, with the goal of enhancing image quality and improving quantification. METHODS: Radial 4D flow MRI acquisitions with fat mitigation (inner volume excitation [IVE] and intermittent fat saturation [FS]) were compared to a standard slab selective excitation (SSE) in a test-retest study of 15 obese participants. IVE selectively excited a cylindrical region of interest, avoiding contamination from peripheral adipose tissue, while FS globally suppressed fat based on spectral selection. Acquisitions were evaluated qualitatively based on expert ratings and quantitatively based on conservation of mass, test-retest repeatability, and a divergence free quality metric. Errors were evaluated statistically using the absolute and relative errors, regression, and Bland-Altman analysis. RESULTS: IVE demonstrated superior performance quantitatively in the conservation of mass analysis in the portal vein, with higher correlation and lower bias in regression analysis. IVE also produced flow fields with the lowest divergence error and was rated best in overall image quality, delineating small vessels, and producing the least streaking artifacts. Evaluation results did not differ significantly between FS and SSE. Test-retest reproducibility was similarly high for all sequences, with data suggesting biological variations dominate the technical variability. CONCLUSION: IVE improved hemodynamic assessment of radial 4D flow MRI in the abdomen of obese participants while FS did not lead to significant improvements in image quality or flow metrics.


Subject(s)
Imaging, Three-Dimensional , Magnetic Resonance Imaging , Humans , Reproducibility of Results , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Adipose Tissue/diagnostic imaging , Obesity/diagnostic imaging
12.
Abdom Radiol (NY) ; 48(6): 2049-2059, 2023 06.
Article in English | MEDLINE | ID: mdl-37016247

ABSTRACT

PURPOSE: The purpose of this work was to establish normal reference values for 4D flow MRI-derived flow, velocity, and vessel diameters, and to define characteristic flow patterns in the portal venous system of healthy adult subjects. METHODS: For this retrospective study, we screened all available 4D flow MRI exams of the upper abdomen in healthy adults acquired at our institution between 2012 and 2022 at either 1.5 T or 3.0 T MRI after ≥ 5 h fasting. Flow, velocity, and effective diameter were quantified in the 8 planes in the portal venous system (splenic vein, superior mesenteric vein, main, right, and left portal veins). Vessel delineation was manually adjusted over time. Reference ranges for were defined as the mean ± 2 standard deviations. Three readers noted helical and vortical flow on time-resolved pathline visualizations. Conservation of mass flow analysis was performed for quality assurance. RESULTS: We included 44 healthy subjects (26 female, 18-74 years) in the analysis. We report reference values for mean and peak flow, mean velocity, and vessel diameter in the healthy portal vein using 4D flow MRI. Normal flow patterns in the portal vein included faint helical (66%) or linear flow (34%). Conservation of mass analysis demonstrated a relative error of 1.1 ± 4.6% standard deviation (SD) at the splenomesenteric confluence and - 1.4 ± 4.1% SD at the portal bifurcation. CONCLUSION: We have reported normal hemodynamic values that are necessary baseline data for emerging clinical applications of 4D flow MRI in the portal venous system. Results are consistent with previously published values from smaller cohorts.


Subject(s)
Abdomen , Magnetic Resonance Imaging , Adult , Humans , Female , Reference Values , Retrospective Studies , Blood Flow Velocity , Magnetic Resonance Imaging/methods , Portal Vein/diagnostic imaging , Imaging, Three-Dimensional/methods
15.
Magn Reson Med ; 89(3): 908-921, 2023 03.
Article in English | MEDLINE | ID: mdl-36404637

ABSTRACT

PURPOSE: To evaluate feasibility and reproducibility of liver diffusion-weighted (DW) MRI using cardiac-motion-robust, blood-suppressed, reduced-distortion techniques. METHODS: DW-MRI data were acquired at 3T in an anatomically accurate liver phantom including controlled pulsatile motion, in eight healthy volunteers and four patients with known or suspected liver metastases. Standard monopolar and motion-robust (M1-nulled, and M1-optimized) DW gradient waveforms were each acquired with single-shot echo-planar imaging (ssEPI) and multishot EPI (msEPI). In the motion phantom, apparent diffusion coefficient (ADC) was measured in the motion-affected volume. In healthy volunteers, ADC was measured in the left and right liver lobes separately to evaluate ADC reproducibility between the two lobes. Image distortions were quantified using the normalized cross-correlation coefficient, with an undistorted T2-weighted reference. RESULTS: In the motion phantom, ADC mean and SD in motion-affected volumes substantially increased with increasing motion for monopolar waveforms. ADC remained stable in the presence of increasing motion when using motion-robust waveforms. M1-optimized waveforms suppressed slow flow signal present with M1-nulled waveforms. In healthy volunteers, monopolar waveforms generated significantly different ADC measurements between left and right liver lobes ( p = 0 . 0078 $$ p=0.0078 $$ , reproducibility coefficients (RPC) =  470 × 1 0 - 6 $$ 470\times 1{0}^{-6} $$ mm 2 $$ {}^2 $$ /s for monopolar-msEPI), while M1-optimized waveforms showed more reproducible ADC values ( p = 0 . 29 $$ p=0.29 $$ , RPC = 220 × 1 0 - 6 $$ \mathrm{RPC}=220\times 1{0}^{-6} $$ mm 2 $$ {}^2 $$ /s for M1-optimized-msEPI). In phantom and healthy volunteer studies, motion-robust acquisitions with msEPI showed significantly reduced image distortion ( p < 0 . 001 $$ p<0.001 $$ ) compared to ssEPI. Patient scans showed reduction of wormhole artifacts when combining M1-optimized waveforms with msEPI. CONCLUSION: Synergistic effects of combined M1-optimized diffusion waveforms and msEPI acquisitions enable reproducible liver DWI with motion robustness, blood signal suppression, and reduced distortion.


Subject(s)
Diffusion Magnetic Resonance Imaging , Liver Neoplasms , Humans , Diffusion Magnetic Resonance Imaging/methods , Reproducibility of Results , Motion , Liver Neoplasms/diagnostic imaging , Echo-Planar Imaging/methods
16.
Ann Biomed Eng ; 50(8): 1001-1016, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35624334

ABSTRACT

4D Flow MRI is a diagnostic tool that can visualize and quantify patient-specific hemodynamics and help interventionalists optimize treatment strategies for repairing coarctation of the aorta (COA). Despite recent developments in 4D Flow MRI, shortcomings include phase-offset errors, limited spatiotemporal resolution, aliasing, inaccuracies due to slow aneurysmal flows, and distortion of images due to metallic artifact from vascular stents. To address these limitations, we developed a framework utilizing Computational Fluid Dynamics (CFD) with Adaptive Mesh Refinement (AMR) that enhances 4D Flow MRI visualization/quantification. We applied this framework to five pediatric patients with COA, providing in-vivo and in-silico datasets, pre- and post-intervention. These two data sets were compared and showed that CFD flow rates were within 9.6% of 4D Flow MRI, which is within a clinically acceptable range. CFD simulated slow aneurysmal flow, which MRI failed to capture due to high relative velocity encoding (Venc). CFD successfully predicted in-stent blood flow, which was not visible in the in-vivo data due to susceptibility artifact. AMR improved spatial resolution by factors of 101 to 103 and temporal resolution four-fold. This computational framework has strong potential to optimize visualization/quantification of aneurysmal and in-stent flows, improve spatiotemporal resolution, and assess hemodynamic efficiency post-COA treatment.


Subject(s)
Aortic Coarctation , Hydrodynamics , Child , Humans , Aortic Coarctation/diagnostic imaging , Blood Flow Velocity , Hemodynamics , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Surgical Mesh
17.
Abdom Radiol (NY) ; 47(6): 2106-2114, 2022 06.
Article in English | MEDLINE | ID: mdl-35419747

ABSTRACT

PURPOSE: To determine the variability of blood flow measurements using 4D flow MRI in the portal and mesenteric circulations and to characterize the effects of meal ingestion, time of day, and between-day (diurnal) variations on portal and mesenteric hemodynamics. METHODS: In this IRB-approved and HIPAA-compliant study, 7 healthy and 7 portal hypertension patients imaged. MRI exams were conducted at 3 T using a 32-channel body coil with large volumetric coverage and 1.25-mm isotropic true spatial resolution. Blood flow was quantified (L/min) in the hepatic and splanchnic vasculature. The first MR scan was performed after at least 8 h of fasting. Subsequently, subjects ingested 574 mL EnSure Plus® orally. A second acquisition was started 20 min after the meal ingestion. A third scan was performed before lunch and a fourth acquisition took place 20 min after lunch. A fifth scan was performed around 4 pm. Finally, subjects returned one week later for a repeat morning visit, with identical conditions as the first visit. RESULTS: In healthy controls significant increase in blood flow was seen in the PV, SMV, SMA, HA, and SCAo in response to breakfast but only the SCAo, SMA, SMV, and PV had a significant response to lunch. In general, patients with cirrhosis showed reduced response to meals compared to that in healthy controls. Additionally, PV flow in patients had the highest value in the afternoon. CONCLUSION: Effects of meal ingestion, time of day, and between-day variations were characterized using Radial 4D flow MRI in patients with cirrhosis and healthy controls.


Subject(s)
Hemodynamics , Magnetic Resonance Imaging , Blood Flow Velocity/physiology , Hemodynamics/physiology , Humans , Liver Cirrhosis , Magnetic Resonance Imaging/methods , Meals
18.
Magn Reson Med Sci ; 21(2): 340-353, 2022 Mar 01.
Article in English | MEDLINE | ID: mdl-35082218

ABSTRACT

Evaluation of the hemodynamics in the portal venous system plays an essential role in many hepatic pathologies. Changes in portal flow and vessel morphology are often indicative of disease.Routinely used imaging modalities, such as CT, ultrasound, invasive angiography, and MRI, often focus on either hemodynamics or anatomical imaging. In contrast, 4D flow MRI facilitiates a more comprehensive understanding of pathophysiological mechanisms by simultaneously and noninvasively acquiring time-resolved flow and anatomical information in a 3D imaging volume.Though promising, 4D flow MRI in the portal venous system is especially challenging due to small vessel calibers, slow flow velocities, and breathing motion. In this review article, we will discuss how to account for these challenges when planning and conducting 4D flow MRI acquisitions in the upper abdomen. We will address patient preparation, sequence acquisition, postprocessing, quality control, and analysis of 4D flow data.In the second part of this article, we will review potential clinical applications of 4D flow MRI in the portal venous system. The most promising area for clinical utilization is the diagnosis and grading of liver cirrhosis and its complications. Relevant parameters acquired by 4D flow MRI include the detection of reduced or reversed flow in the portal venous system, characterization of portosystemic collaterals, and impaired response to a meal challenge. In patients with cirrhosis, 4D flow MRI has the potential to address the major unmet need of noninvasive detection of gastroesophageal varices at high risk for bleeding. This could replace many unnecessary, purely diagnostic, and invasive esophagogastroduodenoscopy procedures, thereby improving patient compliance with follow-up. Moreover, 4D flow MRI offers unique insights and added value for surgical planning and follow-up of multiple hepatic interventions, including transjugular intrahepatic portosystemic shunts, liver transplantation, and hepatic disease in children. Lastly, we will discuss the path to clinical implementation and remaining challenges.


Subject(s)
Magnetic Resonance Imaging , Portal Vein , Abdomen , Blood Flow Velocity/physiology , Child , Humans , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Portal Vein/diagnostic imaging
19.
Abdom Radiol (NY) ; 47(5): 1684-1698, 2022 05.
Article in English | MEDLINE | ID: mdl-33547918

ABSTRACT

PURPOSE: Chronic mesenteric ischemia (CMI) is a rare disease with a particularly difficult diagnosis. In this study, 4D flow MRI is used to quantitatively evaluate mesenteric hemodynamics before and after a meal in patients suspected of having CMI and healthy individuals. METHODS: Nineteen patients suspected of CMI and twenty control subjects were analyzed. Subjects were scanned using a radially undersampled 4D flow MR sequence (PC-VIPR). Flow rates were assessed in the supraceliac (SCAo) and infrarenal aorta, celiac artery, superior mesenteric artery (SMA), left and right renal arteries, superior mesenteric vein (SMV), splenic vein, and portal vein (PV) in a fasting state (preprandial) and 20 min after a 700-kcal meal (postprandial). Patients were subcategorized into positive diagnosis (CMI+, N = 6) and negative diagnosis (CMI-, N = 13) groups based on imaging and clinical findings. Preprandial, postprandial, and percent change in flow rates were compared between subgroups using a Welch t test. RESULTS: In controls and CMI- patients, SCAo, SMA, SMV, and PV flow increased significantly after meal ingestion. No significant flow increases were observed in CMI+ patients. Percent changes in SMA, SMV, and PV flow were significantly greater in controls compared to CMI+ patients. Additionally, percent changes in flow in the SMV and PV were significantly greater in CMI- patients compared to CMI+ patients. CONCLUSIONS: 4D flow MRI with large volumetric coverage demonstrated significant differences in the redistribution of blood flow in SMA, SMV, and PV in CMI+ patients after a meal challenge. This approach may assist in the challenging diagnosis of CMI.


Subject(s)
Mesenteric Ischemia , Chronic Disease , Hemodynamics , Humans , Ischemia , Magnetic Resonance Imaging/methods , Mesenteric Artery, Superior/diagnostic imaging , Mesenteric Ischemia/diagnostic imaging , Mesenteric Veins