Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Biomedicines ; 12(4)2024 Mar 29.
Article in English | MEDLINE | ID: mdl-38672113

ABSTRACT

Growth differentiation factor 15 (GDF-15) is a stress-induced cytokine associated with acute and chronic inflammatory states. This prospective observational study aimed to investigate the prognostic roles of GDF-15 and routine clinical laboratory parameters in COVID-19 patients. Upon the admission of 95 adult hospitalized COVID-19 patients in Croatia, blood analysis was performed, and medical data were collected. The patients were categorized based on survival, ICU admission, and hospitalization duration. Logistic regression and ROC curve methods were employed for the statistical analysis. Logistic regression revealed two independent predictors of negative outcomes: CURB-65 score (OR = 2.55) and LDH (OR = 1.005); one predictor of ICU admission: LDH (OR = 1.004); and one predictor of prolonged hospitalization: the need for a high-flow nasal cannula (HFNC) upon admission (OR = 4.75). The ROC curve showed diagnostic indicators of negative outcomes: age, CURB-65 score, LDH, and GDF-15. The largest area under the curve (AUC = 0.767, specificity = 65.6, sensitivity = 83.9) was represented by GDF-15, with a cutoff value of 3528 pg/mL. For ICU admission, significant diagnostic indicators were LDH, CRP, and IL-6. Significant diagnostic indicators of prolonged hospitalization were CK, GGT, and oxygenation with an HFNC upon admission. This study reaffirms the significance of the commonly used laboratory parameters and clinical scores in evaluating COVID-19. Additionally, it introduces the potential for a new diagnostic approach and research concerning GDF-15 levels in this widespread disease.

2.
Infect Dis (Lond) ; 55(4): 299-302, 2023 04.
Article in English | MEDLINE | ID: mdl-36718519

ABSTRACT

BACKGROUND: A rare case of coinfection of Plasmodium falciparum and SARS-CoV-2 disease in Croatia is presented in this report. METHODS: We tracked epidemiological and laboratory findings in a patient with SARS-CoV-2 and Plasmodium falciparum coinfection. A complete blood count was performed using the Sysmex XN-2000 analyser (Sysmex Corporation, Kobe, Japan), coagulation analyses were performed using the BCS XP coagulometer (Siemens Healthineers AG, Erlangen, Germany). Procalcitonin (PCT) and Interleukin-6 (IL-6) were measured by electrochemiluminescence immunoassay (ECLIA) using the Cobas e411 (Roche Diagnostics GmbH, Mannheim, Germany) analyser and high sensitivity troponin I (hsTnI) was measured using the Dimension EXL with LM analyser (Siemens Healthcare Diagnostics, Newark, USA). All other biochemistry analyses were performed using the Olympus AU680 (Beckman Coulter, Brea, California, USA) analyser. White blood cell differential analysis has been performed by examining the blood smear using the CellaVision DM1200 (CellaVision AB, Lund, Sweden) automatic analyser. RESULTS: Even though the patient's initial health condition was disturbed, as a result of the physician's comprehensive anamnesis accompanied by laboratory findings, prompt diagnosis and appropriate therapy were assured, and consequently, the patient recovered. CONCLUSION: In a pandemic, testing each febrile patient for the SARS-CoV-2 virus is of essential importance. However, the possibility of coinfection with another infectious disease agent cannot be disregarded.


Subject(s)
COVID-19 , Coinfection , Humans , Plasmodium falciparum , SARS-CoV-2 , Coinfection/diagnosis , COVID-19/diagnosis , Blood Cell Count/methods
3.
Biochem Med (Zagreb) ; 30(3): 030704, 2020 Oct 15.
Article in English | MEDLINE | ID: mdl-33071555

ABSTRACT

INTRODUCTION: The aim was to evaluate the BD Barricor tubes by comparison with the BD Rapid Serum Tubes (RST) through measuring 25 analytes and monitoring sample stability after 24 hours and 7 days. MATERIALS AND METHODS: Samples of 52 patients from different hospital departments were examined. Blood was collected in BD RST and BD Barricor tubes (Becton, Dickinson and Company, Franklin Lakes, USA). Analytes were measured by Beckman Coulter AU 480 (Beckman Coulter, Brea, USA), Dimension EXL (Siemens Healthcare Diagnostics, Newark, USA) and ARCHITECT i2000SR (Abbott Diagnostics, Lake Forest, USA). Between-tube comparison for each analyte was performed, along with testing analyte stability after storing samples at 4 °C. RESULTS: BD Barricor tubes showed unacceptable bias compared to BD RST tubes for potassium (K) (- 4.5%) and total protein (4.4%). Analyte stability after 24 hours was acceptable in both tested tubes for most of analytes, except for glucose, aspartate aminotransferase (AST) and lactate dehydrogenase (LD) in BD Barricor and free triiodothyronine in BD RST sample tubes. Analyte stability after 7 days was unacceptable for sodium, K, calcium, creatine kinase isoenzyme MB, AST, LD and troponin I in both samples; additionally for glucose, alkaline phosphatase and albumin in BD Barricor. CONCLUSION: All analytes, except K and total protein, can be measured interchangeably in BD RST and BD Barricor tubes, applying the same reference intervals. For most of the analytes, sample re-analysis can be performed in both tubes after 24 hours and 7 days, although BD RST tubes show better 7-day analytes stability over BD Barricor tubes.


Subject(s)
Blood Specimen Collection/instrumentation , Serum/chemistry , Adult , Aged , Aged, 80 and over , Aspartate Aminotransferases/blood , Blood Proteins/analysis , Blood Specimen Collection/methods , Female , Humans , L-Lactate Dehydrogenase/blood , Male , Middle Aged , Potassium/blood , Sodium/blood , Time Factors , Triiodothyronine/blood , Troponin I/blood , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...