Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Endod ; 49(8): 1004-1011, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37263496

ABSTRACT

INTRODUCTION: This study compared the accuracy and efficiency of fully guided static and dynamic computer-assisted surgical navigation techniques for osteotomy and root-end resection (RER). METHODS: Fifty roots from cadaver heads were divided into two groups: fully guided static computer-assisted endodontic microsurgery (FG sCAEMS) and dynamic computer-assisted endodontic microsurgery (dCAEMS) (all, n = 25). Cone-beam computed tomography scans were taken pre and postoperatively. The osteotomy and RER were planned virtually in the preoperative cone-beam computed tomography scan and guided using 3D-printed surgical guides in the FG sCAEMS and 3D-dynamic navigation system in the dCAEMS. The 2D and 3D deviations and angular deflection were calculated. The osteotomy volume, resected root length, and resection angle were measured. The osteotomy and RER time and the number of procedural mishaps were recorded. RESULTS: FG sCAEMS was as accurate as dCAEMS, with no difference in the 2D and 3D deviation values or angular deflection (P > .05). The osteotomy and RER time were shortened using FG sCAEMS (P < .05). The FG sCAEMS showed a greater number of incomplete RERs than dCAEMS. Osteotomy volume, RER angle, and root length resected were similar in both groups (P > .05). FG sCAEMS and dCAEMS were feasible for osteotomy and RER. CONCLUSIONS: Within the limitations of this cadaver-based study, FG sCAEMS was as accurate as dCAEMS. Both FG sCAEMS and dCAEMS were time-efficient for osteotomy and RER.


Subject(s)
Dental Implants , Surgery, Computer-Assisted , Tooth , Humans , Apicoectomy , Cone-Beam Computed Tomography , Osteotomy/methods , Cadaver
2.
J Endod ; 49(5): 528-535.e1, 2023 May.
Article in English | MEDLINE | ID: mdl-36828284

ABSTRACT

INTRODUCTION: This study compared the accuracy and efficiency of a novel static computer-aided surgical technique using a 3-dimensional (3D)-printed surgical guide (3D-SG) with a fully guided drill protocol (3D-SG FG) to the freehand (FH) osteotomy and root-end resection (RER). METHODS: Forty-six roots from 2 cadaver heads were divided into 2 groups: 3D-SG FG (n = 23) and FH (n = 23). Cone-beam computed tomographic scans were taken preoperatively and postoperatively. The endodontic microsurgery was planned in Blue Sky Bio software, and the 3D-SG was designed and 3D printed. The osteotomy and RER were conducted using a guided twist drill diameter of 2 mm and an ascending tapered drill with diameters of 2.8/3.2, 3.2/3.6, 3.8/4.2, and 4.2 mm with respective guided drill guides. Two-dimensional and three-dimensional virtual deviations and angular deflection were calculated. Linear osteotomy measures and root resection angle were obtained. The osteotomy and RER time and the number of mishaps were recorded. RESULTS: Two-dimensional and three-dimensional accuracy deviations and angular deflection were lower in the 3D-SG FG protocol than in the FH technique (P < .05). The height, length, and depth of the osteotomy and root resection angle were less in the 3D-SG FG protocol than in the FH technique (P < .05). The osteotomy and RER time with the 3D-SG FG protocol were less than the FH method (P < .05). CONCLUSIONS: Within the limitations of this cadaver-based study using denuded maxillary and mandibular jaws, 3D-SG FG protocol showed higher accuracy than FH osteotomy and RER. Moreover, the 3D-SG FG drill protocol significantly reduced the surgical time.


Subject(s)
Printing, Three-Dimensional , Surgery, Computer-Assisted , Humans , Osteotomy , Maxilla , Cone-Beam Computed Tomography , Cadaver , Computers , Computer-Aided Design