Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Orthop Traumatol ; 22(1): 49, 2021 Nov 26.
Article in English | MEDLINE | ID: mdl-34826010

ABSTRACT

BACKGROUND: Several modifications to the original Grammont reverse shoulder arthroplasty (RSA) design have been proposed to prevent distinctive issues, such as both glenoid and humeral lateralization. The aim of this systematic review was to determine rates of problems, complications, reoperations, and revisions after onlay lateralized humeral stem RSA, hypothesizing that these are design related. METHODS: This systematic review was performed in accordance with the PRISMA statement guidelines. A literature search was conducted (1 January 2000 to 14 April 2020) using PubMed, Cochrane Reviews, Scopus, and Google Scholar, employing several combinations of keywords: "reverse shoulder arthroplasty," "reverse shoulder prosthesis," "inverse shoulder arthroplasty," "inverse shoulder prosthesis," "problems," "complications," "results," "outcomes," "reoperation," and "revision." RESULTS: Thirty-one studies with 4893 RSA met inclusion criteria. The 892 postoperative problems and 296 postoperative complications represented overall problem and complication rates of 22.7% and 7.5%, respectively. Forty-one reoperations and 63 revisions resulted, with overall reoperation and revision rates of 1.7% and 2.6%, respectively. CONCLUSIONS: Problem, complication, and reintervention rates proved acceptable when implanting a high humeral lateralization stem RSA. The most frequent problem was scapular notching (12.6%), and the most common postoperative complication was scapular stress fracture (1.8%). An overall humeral complication rate of 1.9% was identified, whereas no humeral fractures or stem loosening were reported with short stems. Infections (1.3%) were the most common reason for component revision, followed by instability (0.8%). LEVEL OF EVIDENCE: Systematic review IV.


Subject(s)
Arthroplasty, Replacement, Shoulder , Shoulder Joint , Shoulder Prosthesis , Arthroplasty, Replacement, Shoulder/adverse effects , Humans , Humerus/surgery , Range of Motion, Articular , Reoperation , Retrospective Studies , Shoulder Joint/surgery , Shoulder Prosthesis/adverse effects , Treatment Outcome
2.
J Orthop Traumatol ; 22(1): 27, 2021 Jul 08.
Article in English | MEDLINE | ID: mdl-34236540

ABSTRACT

BACKGROUND: Several modifications to the original Grammont reverse shoulder arthroplasty (RSA) design have been proposed to prevent distinctive issues, such as both glenoid and humeral lateralization. The aim of this systematic review was to determine rates of problems, complications, reoperations, and revisions after onlay lateralized humeral stem RSA, hypothesizing that these are design related. METHODS: This systematic review was performed in accordance with the PRISMA statement guidelines. A literature search was conducted (01.01.2000-14.04.2020) using PubMed, Cochrane Reviews, Scopus, and Google Scholar employing several combinations of keywords: "reverse shoulder arthroplasty," "reverse shoulder prosthesis," "inverse shoulder arthroplasty," "inverse shoulder prosthesis," "problems," "complications," "results," "outcomes," "reoperation," "revision." RESULTS: Thirty-one studies with 4893 RSA met inclusion criteria. The 892 postoperative problems and 296 postoperative complications represented overall problem and complication rates of 22.7% and 7.5%, respectively. Forty-one reoperations and 63 revisions resulted, with an overall reoperation rate of 1.7% and overall revision rate of 2.6%. CONCLUSIONS: Problem, complication, and reintervention rates proved acceptable when implanting a high humeral lateralization stem in RSA. The most frequent problem was scapular notching (12.6%), and the most common postoperative complication was scapular stress fracture (1.8%). An overall humeral complication rate of 1.9% was identified, whereas short stems reported no humeral fractures or stem loosening. Infections (1.3%) proved to be the most common reason for component revision, and instability had a complication rate of 0.8%. LEVEL OF EVIDENCE: Systematic review IV.


Subject(s)
Arthroplasty, Replacement, Shoulder/methods , Humerus/surgery , Postoperative Complications , Shoulder Fractures/surgery , Shoulder Joint/surgery , Shoulder Prosthesis , Humans , Reoperation , Retrospective Studies , Scapula/surgery
3.
Skeletal Radiol ; 50(9): 1863-1871, 2021 Sep.
Article in English | MEDLINE | ID: mdl-33733694

ABSTRACT

OBJECTIVE: The aim of this work was to evaluate the inter-observer agreement and diagnostic performance values of 7 MRI signs (3 known and 4 new) of long head biceps tendon instability. MATERIALS AND METHODS: MRI of 86 patients were retrospectively evaluated. Inter-observer agreement and diagnostic performance of each diagnostic sign and of all combined signs (with the exception of detour sign) were tested for identification of biceps tendon instability, with arthroscopy as the reference standard. RESULTS: Agreement between expert operators was moderate to good. Sensitivity, specificity, and sign accuracy showed a variation respectively of the following: humeral chondral print 72-80%, 62-68%, and 70-76%; subchondral bone edema 24-31%, 84-97%, and 50%; biceps tendon angle 60-71%, 97-100%, and 74-81%, biceps tendon-groove distance 31-47%, 90-100%, and 56-64%; long head biceps subluxation/dislocation on axial plane 49-53%, 97-100%, and 66-70%; displacement sign 74-80%, 74-100%, and 74-87%; detour sign 51-64%, 58-81%, and 62-64%; and all signs 98-100%, 32-61%, and 75-86%. CONCLUSION: These diagnostic signs, both known and new, individually and/or in combination, provide a valid tool in the MRI diagnosis of long head biceps tendon instability.


Subject(s)
Joint Instability , Shoulder Joint , Arthroscopy , Humans , Joint Instability/diagnostic imaging , Magnetic Resonance Imaging , Retrospective Studies , Tendons/diagnostic imaging
4.
Knee Surg Sports Traumatol Arthrosc ; 29(7): 2348-2355, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33074421

ABSTRACT

PURPOSE: Unrecognized posterior shoulder dislocation with a concomitant humeral head fracture affects joint function and no consensus exists regarding treatment. The present study analyses clinical and radiographic outcomes of a novel arthroscopic technique for reducing chronic locked posterior shoulder dislocation associated with subscapularis remplissage. METHODS: The study comprises a retrospective analysis of consecutive chronic posterior locked shoulders (CPLS) with minimum 2-years follow-up of patients who had undergone McLaughlin technique arthroscopic modification for the treatment of CPLS with a reverse Hill-Sachs lesion. Active range of motion (ROM), Western Ontario (WOSI) and Constant Score (CS), were evaluated pre- and postoperatively. Plain radiographs and magnetic resonance imaging (MRI) scans were collected pre- and post-operatively, recording bone defect, osteoarthritis, cuff integrity/fatty infiltration, and the grade of filling of the reverse Hill-Sachs. RESULTS: Twelve male patients with a mean follow-up of 37.3 months ± 10.5 (range, 24-58) were included. Mean WOSI and CS scores improved from 41 to 92 and 28 to 94 points, respectively. ROM measurements all had significantly increased at final follow-up, with no significant differences in arm rotation. No defects were left unfilled at final MRI examination. CONCLUSION: The results of this uncontrolled study with a limited number of patients confirm that arthroscopic reduction and subscapularis remplissage is a highly effective and satisfactory treatment method resulting in no shoulder rotation deficits. LEVEL OF EVIDENCE: Level IV.


Subject(s)
Arthroscopy/methods , Postoperative Complications/epidemiology , Rotator Cuff/surgery , Shoulder Dislocation/surgery , Adult , Arthroscopy/adverse effects , Humans , Humeral Head/surgery , Joint Instability/surgery , Magnetic Resonance Imaging/methods , Male , Middle Aged , Osteoarthritis/epidemiology , Range of Motion, Articular , Retrospective Studies , Rotation , Rotator Cuff/diagnostic imaging , Shoulder Dislocation/diagnostic imaging , Shoulder Dislocation/physiopathology , Shoulder Fractures/surgery , Shoulder Joint/physiopathology , Shoulder Joint/surgery , Treatment Outcome , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...