Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 18 de 18
Filter
1.
Diabetes Metab Res Rev ; 40(2): e3750, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38018334

ABSTRACT

Post-bariatric hypoglycaemia (PBH) is a metabolic complication of bariatric surgery (BS), consisting of low post-prandial glucose levels in patients having undergone bariatric procedures. While BS is currently the most effective and relatively safe treatment for obesity and its complications, the development of PBH can significantly impact patients' quality of life and mental health. The diagnosis of PBH is still challenging, considering the lack of definitive and reliable diagnostic tools, and the fact that this condition is frequently asymptomatic. However, PBH's prevalence is alarming, involving up to 88% of the post-bariatric population, depending on the diagnostic tool, and this may be underestimated. Given the prevalence of obesity soaring, and an increasing number of bariatric procedures being performed, it is crucial that physicians are skilled to diagnose PBH and promptly treat patients suffering from it. While the milestone of managing this condition is nutritional therapy, growing evidence suggests that old and new pharmacological approaches may be adopted as adjunct therapies for managing this complex condition.


Subject(s)
Bariatric Surgery , Gastric Bypass , Hypoglycemia , Obesity, Morbid , Humans , Blood Glucose/metabolism , Quality of Life , Hypoglycemia/diagnosis , Hypoglycemia/etiology , Hypoglycemia/therapy , Bariatric Surgery/adverse effects , Obesity/complications , Obesity, Morbid/surgery
2.
Pathologica ; 1(1): 181-185, 2023 May.
Article in English | MEDLINE | ID: mdl-37216304

ABSTRACT

Endometrial carcinoma (EC) harboring POLE exonuclease domain mutations occurs in 5-15% of ECs and frequently affects young women with low body mass index (BMI). It presents at early stage as high grade endometrioid histotype with intense tumor infiltrating lymphocytes and has good clinical outcomes and favorable prognosis. In this article we report the case of a 32-year-old woman with endometriod EC (EEC) exhibiting a "ultramutated" molecular profile and an excellent prognosis despite tumor size and grading. Herein, to highlight the importance of defining POLE status in ECs for both clinical and therapeutic implications for patients.


Subject(s)
Carcinoma, Endometrioid , Endometrial Neoplasms , Humans , Female , Adult , Carcinoma, Endometrioid/diagnosis , Carcinoma, Endometrioid/genetics , Carcinoma, Endometrioid/pathology , Mutation , Poly-ADP-Ribose Binding Proteins/genetics , Endometrial Neoplasms/diagnosis , Endometrial Neoplasms/genetics , Endometrial Neoplasms/pathology , Prognosis , Exonucleases/genetics
3.
Pathologica ; 115(2): 107-110, 2023 Apr.
Article in English | MEDLINE | ID: mdl-37114628

ABSTRACT

Platinum-based chemotherapy is the standard chemotherapy for high grade serous ovarian cancer and primary peritoneal high-grade serous carcinoma. PARP inhibitors have changed the paradigm of the treatment in platinum-sensitive ovarian cancers and primary peritoneal high-grade serous carcinoma with BRCA1/2 mutation or homologous recombination deficiency (HRD). Platinum-resistant ovarian and primary peritoneal high-grade serous carcinoma have a lower chance to treat and have worse outcomes. We described a case of patient with a platinum resistant primary peritoneal high-grade serous carcinoma with a rare somatic BRCA2 amplification. There are no guidelines for the treatment of ovarian cancer or primary peritoneal high-grade serous carcinoma with BRCA2 amplification. BRCA2 amplification could result in extreme homologous recombination repair (HRR) pathway efficiency and in less platinum sensitivity, which could be a molecular signature for platinum resistance. Free platinum chemotherapy regimens could be more effective in cases with BRCA2 amplification. Further studies are necessary to establish better approaches and strategies for oncological management and treatment in BRCA2 amplification high grade ovarian cancer and primary peritoneal high-grade serous carcinoma.


Subject(s)
Carcinoma , Ovarian Neoplasms , Female , Humans , BRCA1 Protein/genetics , Gene Amplification , Platinum/therapeutic use , Mutation , BRCA2 Protein/genetics , Ovarian Neoplasms/drug therapy , Ovarian Neoplasms/genetics , Ovarian Neoplasms/pathology , Carcinoma/genetics
4.
Vaccine ; 40(52): 7653-7659, 2022 12 12.
Article in English | MEDLINE | ID: mdl-36372665

ABSTRACT

BACKGROUND: Risk of experiencing a systemic adverse event (AE) after mRNA coronavirus disease 2019 (COVID-19) vaccination may be greater among persons with a history of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection; data on serious events are limited. We assessed if adults reporting systemic AEs resulting in emergency department visits or hospitalizations during days 0-7 after mRNA COVID-19 vaccine dose 1 were more likely to have a history of prior SARS-CoV-2 infection compared with persons who reported no or non-severe systemic AEs. METHODS: We conducted a nested case-control study using v-safe surveillance data. Participants were ≥ 18 years and received dose 1 during December 14, 2020─May 9, 2021. Cases reported severe systemic AEs 0-7 days after vaccination. Three controls were frequency matched per case by age, vaccination date, and days since vaccination. Follow-up surveys collected SARS-CoV-2 histories. RESULTS: Follow-up survey response rates were 38.6 % (potential cases) and 56.8 % (potential controls). In multivariable analyses including 3,862 case-patients and 11,586 controls, the odds of experiencing a severe systemic AE were 2.4 (Moderna, mRNA-1273; 95 % confidence interval [CI]: 1.89, 3.09) and 1.5 (Pfizer-BioNTech, BNT162b2; 95 % CI: 1.17, 2.02) times higher among participants with pre-vaccination SARS-CoV-2 histories compared with those without. Medical attention of any kind for symptoms during days 0-7 following dose 2 was not common among case-patients or controls. CONCLUSIONS: History of SARS-CoV-2 infection was significantly associated with severe systemic AEs following dose 1 of mRNA COVID-19 vaccine; the effect varied by vaccine received. Most participants who experienced severe systemic AEs following dose 1 did not require medical attention of any kind for symptoms following dose 2. Vaccine providers can use these findings to counsel patients who had pre-vaccination SARS-CoV-2 infection histories, experienced severe systemic AEs following dose 1, and are considering not receiving additional mRNA COVID-19 vaccine doses.


Subject(s)
2019-nCoV Vaccine mRNA-1273 , BNT162 Vaccine , Vaccination , Adult , Humans , BNT162 Vaccine/adverse effects , Case-Control Studies , COVID-19/prevention & control , SARS-CoV-2 , Vaccination/adverse effects , 2019-nCoV Vaccine mRNA-1273/adverse effects
5.
Cells ; 11(15)2022 08 04.
Article in English | MEDLINE | ID: mdl-35954264

ABSTRACT

Obesity is associated with increased cardiovascular morbidity. Adult patients with growth hormone deficiency (GHD) show morpho-functional cardiological alterations. A total of 353 overweight/obese patients are enrolled in the period between 2009 and 2019 to assess the relationships between GH secretory capacity and the metabolic phenotype, cardiovascular risk factors, body composition and cardiac echocardiographic parameters. All patients underwent GHRH + arginine test to evaluate GH secretory capacity, DEXA for body composition assessment and transthoracic echocardiography. Blood samples are also collected for the evaluation of metabolic parameters. In total, 144 patients had GH deficiency and 209 patients had normal GH secretion. In comparing the two groups, we found significant differences in body fat distribution with predominantly visceral adipose tissue accumulation in GHD patients. Metabolic syndrome is more prevalent in the GHD group. In particular, fasting glycemia, triglycerides and systolic and diastolic blood pressure are found to be linearly correlated with GH secretory capacity. Epicardial fat thickness, E/A ratio and indexed ventricular mass are worse in the GHD group. In the population studied, metabolic phenotype, body composition, cardiovascular risk factors and cardiac morphology are found to be related to the GH secretory capacity. GH secretion in the obese patient seems to be an important determinant of metabolic health.


Subject(s)
Human Growth Hormone , Overweight , Body Composition , Cross-Sectional Studies , Human Growth Hormone/metabolism , Humans , Obesity/metabolism
6.
Front Public Health ; 10: 809356, 2022.
Article in English | MEDLINE | ID: mdl-35425748

ABSTRACT

We aimed to describe frequency of COVID-19 exposure risk factors among patients presenting for medical care at an urban, public hospital serving mostly uninsured/Medicare/Medicaid clients and risk factors associated with SARS-CoV-2 infection. Consenting, adult patients seeking care at a public hospital from August to November 2020 were enrolled in this cross-sectional investigation. Saliva, anterior nasal and nasopharyngeal swabs were collected and tested for SARS-CoV-2 using RT-PCR. Participant demographics, close contact, and activities ≤14 days prior to enrollment were collected through interview. Logistic regression was used to identify risk factors associated with testing positive for SARS-CoV-2. Among 1,078 participants, 51.8% were male, 57.0% were aged ≥50 years, 81.3% were non-Hispanic Black, and 7.6% had positive SARS-CoV-2 tests. Only 2.7% reported COVID-19 close contact ≤14 days before enrollment; this group had 6.79 adjusted odds of testing positive (95%CI = 2.78-16.62) than those without a reported exposure. Among participants who did not report COVID-19 close contact, working in proximity to ≥10 people (adjusted OR = 2.17; 95%CI = 1.03-4.55), choir practice (adjusted OR = 11.85; 95%CI = 1.44-97.91), traveling on a plane (adjusted OR = 5.78; 95%CI = 1.70-19.68), and not participating in an essential indoor activity (i.e., grocery shopping, public transit use, or visiting a healthcare facility; adjusted OR = 2.15; 95%CI = 1.07-4.30) were associated with increased odds of testing positive. Among this population of mostly Black, non-Hispanic participants seeking care at a public hospital, we found several activities associated with testing positive for SARS-CoV-2 infection in addition to close contact with a case. Understanding high-risk activities for SARS-CoV-2 infection among different communities is important for issuing awareness and prevention strategies.


Subject(s)
COVID-19 , Adult , Aged , COVID-19/diagnosis , COVID-19/epidemiology , Cross-Sectional Studies , Female , Georgia/epidemiology , Hospitals, Public , Humans , Male , Medicare , Risk Factors , SARS-CoV-2 , United States
7.
Nutrients ; 14(7)2022 Mar 28.
Article in English | MEDLINE | ID: mdl-35406023

ABSTRACT

Chrononutrition is an emerging branch of chronobiology focusing on the profound interactions between biological rhythms and metabolism. This framework suggests that, just like all biological processes, even nutrition follows a circadian pattern. Recent findings elucidated the metabolic roles of circadian clocks in the regulation of both hormone release and the daily feeding-fasting cycle. Apart from serving as energy fuel, ketone bodies play pivotal roles as signaling mediators and drivers of gene transcription, promoting food anticipation and loss of appetite. Herein we provide a comprehensive review of the literature on the effects of the ketogenic diets on biological processes that follow circadian rhythms, among them appetite, sleep, and endocrine function.


Subject(s)
Circadian Clocks , Circadian Rhythm , Appetite , Circadian Clocks/physiology , Circadian Rhythm/physiology , Hormones , Ketone Bodies , Sleep/physiology
8.
Clin Infect Dis ; 75(1): e122-e132, 2022 08 24.
Article in English | MEDLINE | ID: mdl-35147176

ABSTRACT

BACKGROUND: In Spring 2021, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) B.1.1.7 (Alpha) became the predominant variant in the United States. Research suggests that Alpha has increased transmissibility compared with non-Alpha lineages. We estimated household secondary infection risk (SIR), assessed characteristics associated with transmission, and compared symptoms of persons with Alpha and non-Alpha infections. METHODS: We followed households with SARS-CoV-2 infection for 2 weeks in San Diego County and metropolitan Denver, January to April 2021. We collected epidemiologic information and biospecimens for serology, reverse transcription-polymerase chain reaction (RT-PCR), and whole-genome sequencing. We stratified SIR and symptoms by lineage and identified characteristics associated with transmission using generalized estimating equations. RESULTS: We investigated 127 households with 322 household contacts; 72 households (56.7%) had member(s) with secondary infections. SIRs were not significantly higher for Alpha (61.0% [95% confidence interval, 52.4-69.0%]) than non-Alpha (55.6% [44.7-65.9%], P = .49). In households with Alpha, persons who identified as Asian or Hispanic/Latino had significantly higher SIRs than those who identified as White (P = .01 and .03, respectively). Close contact (eg, kissing, hugging) with primary cases was associated with increased transmission for all lineages. Persons with Alpha infection were more likely to report constitutional symptoms than persons with non-Alpha (86.9% vs 76.8%, P = .05). CONCLUSIONS: Household SIRs were similar for Alpha and non-Alpha. Comparable SIRs may be due to saturation of transmission risk in households due to extensive close contact, or true lack of difference in transmission rates. Avoiding close contact within households may reduce SARS-CoV-2 transmission for all lineages among household members.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/epidemiology , Family Characteristics , Humans , SARS-CoV-2/genetics , United States/epidemiology
9.
Vaccines (Basel) ; 10(1)2022 Jan 05.
Article in English | MEDLINE | ID: mdl-35062740

ABSTRACT

Obesity is associated with a poor COVID-19 prognosis, and it seems associated with reduced humoral response to vaccination. Public health campaigns have advocated for weight loss in subjects with obesity, hoping to eliminate this risk. However, no evidence proves that weight loss leads to a better prognosis or a stronger immune response to vaccination. We aimed to investigate the impact of rapid weight loss on the adaptive immune response in subjects with morbid obesity. Twenty-one patients followed a hypocaloric, very-low-carbohydrate diet one week before to one week after the two mRNA vaccine doses. The diet's safety and efficacy were assessed, and the adaptive humoral (anti-SARS CoV-2 S antibodies, Abs) and cell-mediated responses (IFNγ secretion on stimulation with two different SARS CoV-2 peptide mixes, IFNγ-1 and IFNγ-2) were evaluated. The patients lost ~10% of their body weight with metabolic improvement. A high baseline BMI correlated with a poor immune response (R -0.558, p = 0.013 for IFNγ-1; R -0.581, p = 0.009 for IFNγ-2; R -0.512, p = 0.018 for Abs). Furthermore, there was a correlation between weight loss and higher IFNγ-2 (R 0.471, p = 0.042), and between blood glucose reduction and higher IFNγ-1 (R 0.534, p = 0.019), maintained after weight loss and waist circumference reduction adjustment. Urate reduction correlated with higher Abs (R 0.552, p = 0.033). In conclusion, obesity is associated with a reduced adaptive response to a COVID-19 mRNA vaccine, and weight loss and metabolic improvement may reverse the effect.

10.
Diabetes Metab Res Rev ; 38(1): e3465, 2022 01.
Article in English | MEDLINE | ID: mdl-33955644

ABSTRACT

AIMS: To explore variables associated with the serological response following COVID-19 mRNA vaccine. METHODS: Eighty-six healthcare workers adhering to the vaccination campaign against COVID-19 were enrolled in January-February 2021. All subjects underwent two COVID-19 mRNA vaccine inoculations (Pfizer/BioNTech) separated by 3 weeks. Blood samples were collected before the 1st and 1-4 weeks after the second inoculation. Clinical history, demographics, and vaccine side effects were recorded. Baseline anthropometric parameters were measured, and body composition was performed through dual-energy-X-ray absorptiometry. RESULTS: Higher waist circumference was associated with lower antibody (Ab) titres (R = -0.324, p = 0.004); smokers had lower levels compared to non-smokers [1099 (1350) vs. 1921 (1375), p = 0.007], as well as hypertensive versus normotensive [650 ± 1192 vs. 1911 (1364), p = 0.001] and dyslipideamic compared to those with normal serum lipids [534 (972) vs 1872 (1406), p = 0.005]. Multivariate analysis showed that higher waist circumference, smoking, hypertension, and longer time elapsed since second vaccine inoculation were associated with lower Ab titres, independent of BMI, age. and gender. CONCLUSIONS: Central obesity, hypertension, and smoking are associated with lower Ab titres following COVID-19 vaccination. Although it is currently impossible to determine whether lower SARS-CoV-2 Abs lead to higher likelihood of developing COVID-19, it is well-established that neutralizing antibodies correlate with protection against several viruses including SARS-CoV-2. Our findings, therefore, call for a vigilant approach, as subjects with central obesity, hypertension, and smoking could benefit from earlier vaccine boosters or different vaccine schedules.


Subject(s)
Antibodies, Viral , BNT162 Vaccine , SARS-CoV-2 , Antibodies, Viral/blood , BNT162 Vaccine/administration & dosage , BNT162 Vaccine/immunology , COVID-19/prevention & control , Humans , Hypertension/immunology , Obesity, Abdominal/immunology , SARS-CoV-2/immunology , Smoking/immunology
11.
Emerg Infect Dis ; 27(8): 2081-2089, 2021.
Article in English | MEDLINE | ID: mdl-34286681

ABSTRACT

We evaluated the performance of self-collected anterior nasal swab (ANS) and saliva samples compared with healthcare worker-collected nasopharyngeal swab specimens used to test for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). We used the same PCR diagnostic panel to test all self-collected and healthcare worker-collected samples from participants at a public hospital in Atlanta, Georgia, USA. Among 1,076 participants, 51.9% were men, 57.1% were >50 years of age, 81.2% were Black (non-Hispanic), and 74.9% reported >1 chronic medical condition. In total, 8.0% tested positive for SARS-CoV-2. Compared with nasopharyngeal swab samples, ANS samples had a sensitivity of 59% and saliva samples a sensitivity of 68%. Among participants tested 3-7 days after symptom onset, ANS samples had a sensitivity of 80% and saliva samples a sensitivity of 85%. Sensitivity varied by specimen type and patient characteristics. These findings can help physicians interpret PCR results for SARS-CoV-2.


Subject(s)
COVID-19 , SARS-CoV-2 , Aged, 80 and over , COVID-19 Testing , Georgia , Humans , Male , Nasopharynx , Saliva , Specimen Handling
12.
BMC Infect Dis ; 21(1): 423, 2021 May 05.
Article in English | MEDLINE | ID: mdl-33952212

ABSTRACT

BACKGROUND: In the US, one in six men who have sex with men (MSM) with HIV are unaware of their HIV infection. In certain circumstances, access to HIV testing and viral load (VL) monitoring is challenging. The objective of this study was to evaluate the feasibility of conducting laboratory-based HIV and antiretroviral (ARV) drug testing, and VL monitoring as part of two studies on self-collected dried blood spots (DBS). METHODS: Participants were instructed to collect DBS by self-fingerstick in studies that enrolled MSM online. DBS from the first study (N = 1444) were tested with HIV serological assays approved by the Food and Drug Administration (FDA). A subset was further tested with laboratory-modified serological and VL assays, and ARV levels were measured by mass spectrometry. DBS from the second study (N = 74) were only tested to assess VL monitoring. RESULTS: In the first study, the mail back rate of self-collected DBS cards was 62.9%. Ninety percent of DBS cards were received at the laboratory within 2 weeks from the day of collection, and 98% of the cards had sufficient spots for one assay. Concordance between FDA-approved and laboratory-modified protocols was high. The samples with undetectable ARV had higher VL than samples with at least one ARV drug. In the second study, 70.3% participants returned self-collected DBS cards, and all had sufficient spots for VL assay. High VL was observed in samples from participants who reported low ARV adherence. CONCLUSIONS: In these studies, MSM were able to collect and provide adequate DBS for HIV testing. The FDA-approved and laboratory-modified testing algorithms performed similarly. DBS collected at home may be feasible for HIV testing, ARV measurement, and monitoring viral suppression.


Subject(s)
Anti-HIV Agents/therapeutic use , Dried Blood Spot Testing/methods , HIV Infections/virology , Self-Testing , Viral Load/methods , Adult , Anti-HIV Agents/pharmacology , Feasibility Studies , HIV Infections/diagnosis , HIV Infections/drug therapy , Homosexuality, Male , Humans , Male , Medication Adherence , Sexual and Gender Minorities , United States
13.
Am J Public Health ; 111(5): 907-916, 2021 05.
Article in English | MEDLINE | ID: mdl-33734845

ABSTRACT

Objectives. To assess SARS-CoV-2 transmission within a correctional facility and recommend mitigation strategies.Methods. From April 29 to May 15, 2020, we established the point prevalence of COVID-19 among incarcerated persons and staff within a correctional facility in Arkansas. Participants provided respiratory specimens for SARS-CoV-2 testing and completed questionnaires on symptoms and factors associated with transmission.Results. Of 1647 incarcerated persons and 128 staff tested, 30.5% of incarcerated persons (range by housing unit = 0.0%-58.2%) and 2.3% of staff tested positive for SARS-CoV-2. Among those who tested positive and responded to symptom questions (431 incarcerated persons, 3 staff), 81.2% and 33.3% were asymptomatic, respectively. Most incarcerated persons (58.0%) reported wearing cloth face coverings 8 hours or less per day, and 63.3% reported close contact with someone other than their bunkmate.Conclusions. If testing remained limited to symptomatic individuals, fewer cases would have been detected or detection would have been delayed, allowing transmission to continue. Rapid implementation of mass testing and strict enforcement of infection prevention and control measures may be needed to mitigate spread of SARS-CoV-2 in this setting.


Subject(s)
COVID-19 Testing , COVID-19 , Correctional Facilities/statistics & numerical data , Adult , Aged , Aged, 80 and over , Arkansas/epidemiology , COVID-19/epidemiology , COVID-19/transmission , Housing/statistics & numerical data , Humans , Male , Middle Aged , Prevalence , Prisoners/statistics & numerical data , Surveys and Questionnaires
14.
J Community Health ; 45(6): 1228-1235, 2020 12.
Article in English | MEDLINE | ID: mdl-32651767

ABSTRACT

HIV rapid testing algorithms (RTAs) using any two orthogonal rapid tests (RTs) allow for on-site confirmation of infection. RTs vary in performance characteristics therefore the selection of RTs in an algorithm may affect identification of infection, particularly if acute. National HIV Behavioral Surveillance (NHBS) assessed RTAs among men who have sex with men recruited using anonymous venue-based sampling. Different algorithms were evaluated among participants who self-reported never having received a positive HIV test result prior to the interview. NHBS project areas performed sequential or parallel RTs using whole blood. Participants with at least one reactive RT were offered anonymous linkage to care and provided a dried blood spot (DBS) for testing at CDC. Discordant results (RT-1 reactive/RT-2 non-reactive) were tested at CDC with lab protocols modified for DBS. DBS were also tested for HIV-1 RNA (VL) and antiretroviral (ARV) drug levels. Of 6500 RTAs, 238 were RT-1 reactive; of those, 97.1% (231/238) had concordant results (RT-1/RT-2 reactive) and 2.9% (7/238) had discordant results. Five DBS associated with discordant results were available for confirmation at CDC. Four had non-reactive confirmatory test results that implied RT-1 false reactivity; one had ambiguous confirmatory test results which was non-reactive in further testing. Regardless of order and type of RT used, RTAs demonstrated high concordant results in the population surveyed. Additional laboratory testing on DBS following discordant results confirmed no infection. Implementing RTAs in the context of anonymous venue-based HIV testing could be an option when laboratory follow-up is not practicable.


Subject(s)
HIV Infections/epidemiology , HIV Testing/methods , Adult , Algorithms , Homosexuality, Male , Humans , Male , Sexual and Gender Minorities
15.
J Clin Virol ; 129: 104479, 2020 08.
Article in English | MEDLINE | ID: mdl-32531665

ABSTRACT

BACKGROUND: Currently, FDA-approved HIV-1 viral load (VL) assays use venipuncture-derived plasma. The Hologic Panther system uses 0.7 mL total volume for the Aptima HIV-1 Quant Assay standard (APT-Quant-std) and dilution (APT-Quant-dil) protocols. However, smaller plasma volumes from fingerstick whole blood (FSB) collected in EDTA-microtainer tubes (MCT) could provide an easier sample collection method for HIV-1 VL testing. OBJECTIVES: To evaluate the performance of the APT-Quant-std compared to the Roche CAP/CTM and Abbott m2000RT VL assays and an alternative APTQuant 1:7 dilution protocol, the latter using 100 µL of MCT-derived plasma from FSB. STUDY DESIGN: Linearity was determined using commercial HIV-1 RNA plasma controls. Dilutions ranging 1.56-2.95 log10 copies/mL were prepared to determine the APT-Quant-dil Limit of Quantitation (LOQ) using Probit analysis. Specificity of APT-Quant-std was calculated using 326 HIVnegative samples. To evaluate agreement, 329 plasma specimens were tested with APT-Quant-std, CAP/CTM, and m2000RT. Forty-seven matched venipuncture and MCT-derived plasma specimens were tested with APT-Quant-std and APT-Quant-dil. RESULTS: Among the RNA controls, specificity was 99.69 % for APT-Quant-std. The R2 values were 0.988 (APT-Quant-std/CAP/CTM), 0.980 (APT-Quant-std/ m2000RT), and 0.997 (APT-Quant-std/APT-Quant-dil). The APT-Quant-dil LOQ was estimated at 2.7 log10 copies/mL (500 copies/mL) (95 %CI 2.62-2.87). At 2.3 log10 copies/mL (200 copies/mL), the overall agreement was 91.0 % for APT-Quant-std/CAP/CTM, 85.7 % for APT-Quant-std/m2000RT, and 82.9 % for APT-Quant-std/APT-Quant-dil. Quantified APT-Quant-std results were on average 0.2 log10 copies/mL higher than CAP/CTM and m2000RT and 0.14 log10 copies/mL higher than APT-Quant-dil. CONCLUSION: APT-Quant showed similar performance compared to the CAP/CTM and m2000RT assays and remains sensitive and accurate using the dilution protocol.


Subject(s)
HIV Infections , HIV-1 , HIV Infections/diagnosis , HIV-1/genetics , Humans , RNA , RNA, Viral/genetics , Sensitivity and Specificity , Viral Load
16.
J Clin Virol ; 127: 104344, 2020 06.
Article in English | MEDLINE | ID: mdl-32305880

ABSTRACT

BACKGROUND: The Reveal G4 antibody rapid test is FDA-approved for HIV-1 detection using the versions LAB S/P and POC in CLIA-moderate complexity settings with serum/plasma and whole blood, respectively. The same Reveal tests are CE-marked for HIV-1 and HIV-2 detection in laboratory and point-of-care (POC) settings. OBJECTIVE: We compared the performance of G4 LAB S/P with plasma and POC with whole blood (blood) for detecting early and established HIV-1/HIV-2 infections. STUDY DESIGN: Matched well-characterized plasma and simulated blood were used to evaluate: sensitivity in 104 HIV-1 and 55 HIV-2 established infections, specificity in 49 HIV-negative, and reactivity in early HIV-1 infection in a performance panel (n=38) and 18 plasma panels from seroconverters (SCs, n=183). Median number of days after first RNA-positive was calculated for 13 SCs. Impact of viral suppression (VS) was evaluated in 3 SCs receiving early antiretroviral therapy (ART). RESULTS: Sensitivity was 100 % for HIV-1 and 98.18 % for HIV-2, while specificity was 100 %. All 38 plasma and blood become reactive by Fiebig stage V. Of 18 SCs, 10 had similar reactivity in plasma/blood, 7 showed delayed reactivity in blood, and 1 was nonreactive in plasma/blood. The median days for a G4-reactive after first RNApositive was 13 for plasma and 14 for blood. Long-term VS had no impact on G4 reactivity. CONCLUSIONS: Overall reactivity in early HIV-1 infections is delayed by one day in blood compared to plasma. If FDA-approved for POC settings, the G4 POC is a fast sensitive screening tool for HIV-1/HIV-2-specific IgG even during VS.


Subject(s)
HIV Antibodies/blood , HIV Infections/diagnosis , Serologic Tests/methods , HIV Infections/blood , HIV Infections/immunology , HIV Seropositivity/blood , HIV Seropositivity/diagnosis , HIV-1/immunology , HIV-2/immunology , Humans , Point-of-Care Testing , Reagent Kits, Diagnostic , Sensitivity and Specificity
17.
Sex Transm Dis ; 47(5S Suppl 1): S26-S31, 2020 05.
Article in English | MEDLINE | ID: mdl-31977972

ABSTRACT

BACKGROUND: There is benefit to early HIV-1 diagnosis and treatment, but there is no Food and Drug Administration-approved quantitative assay with a diagnostic claim. We compared the performance of the Hologic Aptima HIV-1 Quant (APT-Quant) and Aptima HIV-1 Qual (APT-Qual) assays for diagnostic use and the performance of a diagnostic algorithm consisting of Bio-Rad BioPlex 2200 HIV Ag-Ab assay (BPC) followed by APT-Quant (2-test) compared with BPC followed by Geenius HIV-1/2 supplemental assay (Geenius) with reflex to APT-Qual (3-test). METHODS: Five hundred twenty-four plasma, which included 419 longitudinal specimens from HIV-1 seroconverters (78 were after initiating antiretroviral therapy [ART]) and 105 from ART-naive persons with established HIV-1 infections, were used to evaluate APT-Quant performance for diagnostic use. Specimens from 200 HIV-negative persons were used to measure specificity. For the algorithm comparison, BPC-reactive specimens were evaluated with the 2-test or 3-test algorithm. McNemar's test was used to compare performance. RESULTS: The APT-Quant detected more samples early in infection compared with APT-Qual. The APT-Quant specificity was 99.8%. Before ART initiation, the algorithms performed similarly among samples from different stages of infection. After ART initiation, the 3-test algorithm performed significantly better (P = 0.0233). CONCLUSIONS: The APT-Quant has excellent performance for diagnostic use. The 2-test algorithm works well in ART-naive samples, but its performance decreases after the IgG response is elicited and with ART-induced suppressed viremia. Providing confirmation and viral load assay with 1 test result could be advantageous for patient care. However, additional factors and challenges associated with the implementation of this 2-test algorithm, such as cost, specimen type, and collection need further evaluation.


Subject(s)
HIV Antibodies/blood , HIV Infections/blood , HIV-1/isolation & purification , Nucleic Acid Amplification Techniques/standards , RNA, Viral/blood , Reagent Kits, Diagnostic/standards , Viral Load/methods , Algorithms , HIV Infections/diagnosis , HIV Infections/drug therapy , HIV-1/genetics , Humans , Polymerase Chain Reaction/methods , RNA, Viral/genetics , Reproducibility of Results , Sensitivity and Specificity
18.
J Clin Virol ; 122: 104214, 2020 01.
Article in English | MEDLINE | ID: mdl-31835210

ABSTRACT

BACKGROUND: Cepheid's Xpert HIV-1 Viral Load (Xpert VL), a simplified, automated, single-use quantitative assay used with the GeneXpert System, is not FDA approved. OBJECTIVES: Using stored plasma, we conducted a study to assess the ability of Xpert VL to quantify viral load relative to the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 (Cobas VL) and to examine the use of the Xpert VL as a qualitative diagnostic test. STUDY DESIGN: Following HIV-1 viral stock dilutions, we conducted a probit analysis to identify the concentration where 95 % of specimens had quantified VLs. We also examined Xpert and Cobas log VL correlation in linearity panels; compared the proportion of 220 seroconverter specimens with virus detected using McNemar's test; and tested specimens from persons with untreated, established HIV-1 infection (n=149) and uninfected persons (n=497). Furthermore, we examined Xpert VL as a qualitative test in seroconverter specimens with early (n=20) and later (n=68) acute infections. RESULTS: At 1.80 log10 copies/mL, 95 % of specimens had quantifiable virus using Xpert VL. Xpert and Cobas VLs were highly correlated (R2=0.994). The proportion of seroconverter specimens with virus detected using Cobas and with Xpert VL was not statistically different (p=0.0578). Xpert VL detected 97.9 % of established infections, and specificity was 99.80 % (95 % CI 98.87%-99.99%). Xpert VL detected 90 % and 98.5 % of early and later acute infections, respectively. CONCLUSIONS: If approved, Xpert VL could allow U.S. laboratories that cannot bring on large, complex testing platforms to conduct HIV monitoring. An approval for diagnostic use may provide timely identification of HIV infections.


Subject(s)
HIV Infections/diagnosis , Nucleic Acid Amplification Techniques/methods , RNA, Viral/blood , Viral Load/methods , Automation, Laboratory , HIV Infections/blood , HIV Infections/virology , HIV-1 , Humans , Sensitivity and Specificity , Specimen Handling
SELECTION OF CITATIONS
SEARCH DETAIL
...