Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Vis Exp ; (179)2022 01 07.
Article in English | MEDLINE | ID: mdl-35068477

ABSTRACT

As the leading cause of blindness, cataracts are a significant burden for the tens of millions of people affected globally by this condition. Chemical exposures, among other environmental factors, are an established cause of cataracts. Ocular toxicity testing can assess whether pharmaceuticals and their components may contribute to lens damage that may lead to cataracts or aid the treatment of cataracts. In vitro studies and in vivo animal testing can be used for assessing the safety of chemicals prior to clinical studies. The Draize test-the current in vivo standard for ocular toxicity and irritancy testing-has been criticized for lack of sensitivity and objective measurements of determining ocular toxicity. In vitro cell-based assays are limited as cell cultures cannot appropriately model an intact functional lens. The method described here is a sensitive in vitro alternative to animal testing, designed to evaluate the response of the intact bovine lens to treatment at both the cellular activity level and for overall refractive performance. The non-toxic reagent resazurin is metabolized in proportion to the level of cell activity. The lens laser-scanner assay measures the ability of the lens to refract incident beams of light to a single point with minimal error, directly relevant to its natural function. The method may be used to determine both acute and delayed changes in the lens, as well as the recovery of the lens from chemical or environmental exposures.


Subject(s)
Excipients , Lens, Crystalline , Animals , Cattle , Eye , Humans , Lens, Crystalline/physiology , Organ Culture Techniques , Toxicity Tests/methods
2.
J Vis Exp ; (110): e53907, 2016 Apr 06.
Article in English | MEDLINE | ID: mdl-27078088

ABSTRACT

Currently, in vitro evaluations of contact lenses (CLs) for drug delivery are typically performed in large volume vials, which fail to mimic physiological tear volumes. The traditional model also lacks the natural tear flow component and the blinking reflex, both of which are defining factors of the ocular environment. The development of a novel model is described in this study, which consists of a unique 2-piece design, eyeball and eyelid piece, capable of mimicking physiological tear volume. The models are created from 3-D printed molds (Polytetrafluoroethylene or Teflon molds), which can be used to generate eye models from various polymers, such as polydimethylsiloxane (PDMS) and agar. Further modifications to the eye pieces, such as the integration of an explanted human or animal cornea or human corneal construct, will permit for more complex in vitro ocular studies. A commercial microfluidic syringe pump is integrated with the platform to emulate physiological tear secretion. Air exposure and mechanical wear are achieved using two mechanical actuators, of which one moves the eyelid piece laterally, and the other moves the eyeballeyepiece circularly. The model has been used to evaluate CLs for drug delivery and deposition of tear components on CLs.


Subject(s)
Contact Lenses , Cornea/metabolism , Tears/physiology , Animals , Anti-Bacterial Agents/pharmacokinetics , Blinking , Cattle , Disposable Equipment , Drug Delivery Systems , Fluoroquinolones/pharmacokinetics , Microscopy, Confocal , Moxifloxacin , Tears/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL