Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 159
Filter
1.
Article in English | MEDLINE | ID: mdl-38752963

ABSTRACT

BACKGROUND: Pulmonary vein isolation is an effective treatment for atrial fibrillation (AF). Cryoballoon ablation using the Arctic Front cryoballoon (Medtronic) was found to be superior to antiarrhythmic drug treatment. Recently, a novel cryoballoon system was introduced (PolarX, Boston Scientific). OBJECTIVES: The purpose of this study was to compare the efficacy and safety of the 2 cryoballoons in a randomized controlled trial. METHODS: Patients with symptomatic paroxysmal AF were enrolled in 2 centers and randomized 1:1 to pulmonary vein isolation using the PolarX or the Arctic Front cryoballoon. All patients received an implantable cardiac monitor. The primary endpoint was first recurrence of atrial tachyarrhythmia (AF, atrial flutter, or atrial tachycardia [AT]) between days 91 and 365. Procedural safety was assessed by a composite of tamponade, phrenic nerve palsy lasting >24 hours, vascular complications, stroke/transient ischemic attack, atrioesophageal fistula or death up to 30 days. RESULTS: A total of 201 patients were enrolled. At 1 year, recurrence of atrial tachyarrhythmia had occurred in 41 of 99 patients (41.6%) assigned to the PolarX group and in 48 of 102 patients (47.1%) assigned to the Arctic Front group (HR: 0.85 [95% CI: 0.56-1.30]; P = 0.03 for noninferiority; P = 0.46 for superiority). The safety endpoint occurred in 5 patients (5%) in the PolarX group (n = 5 phrenic nerve palsies lasting >24 hours), whereas no safety endpoints occurred in the Arctic Front group (P = 0.03). CONCLUSIONS: In this randomized controlled trial using implantable cardiac monitors for continuous rhythm monitoring, the novel PolarX cryoballoon was noninferior compared with the Arctic Front cryoballoon regarding efficacy. However, the PolarX balloon resulted in significantly more phrenic nerve palsies. (Comparison of PolarX and the Arctic Front Cryoballoons for PVI in Patients With Symptomatic Paroxysmal AF [COMPARE-CRYO]; NCT04704986).

2.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38781099

ABSTRACT

AIMS: Cardioneuroablation (CNA) is a catheter-based intervention for recurrent vasovagal syncope (VVS) that consists in the modulation of the parasympathetic cardiac autonomic nervous system. This survey aims to provide a comprehensive overview of current CNA utilization in Europe. METHODS AND RESULTS: A total of 202 participants from 40 different countries replied to the survey. Half of the respondents have performed a CNA during the last 12 months, reflecting that it is considered a treatment option of a subset of patients. Seventy-one per cent of respondents adopt an approach targeting ganglionated plexuses (GPs) systematically in both the right atrium (RA) and left atrium (LA). The second most common strategy (16%) involves LA GP ablation only after no response following RA ablation. The procedural endpoint is frequently an increase in heart rate. Ganglionated plexus localization predominantly relies on an anatomical approach (90%) and electrogram analysis (59%). Less utilized methods include pre-procedural imaging (20%), high-frequency stimulation (17%), and spectral analysis (10%). Post-CNA, anticoagulation or antiplatelet therapy is prescribed, with only 11% of the respondents discharging patients without such medication. Cardioneuroablation is perceived as effective (80% of respondents) and safe (71% estimated <1% rate of procedure-related complications). Half view CNA emerging as a first-line therapy in the near future. CONCLUSION: This survey offers a snapshot of the current implementation of CNA in Europe. The results show high expectations for the future of CNA, but important heterogeneity exists regarding indications, procedural workflow, and endpoints of CNA. Ongoing efforts are essential to standardize procedural protocols and peri-procedural patient management.


Subject(s)
Catheter Ablation , Syncope, Vasovagal , Humans , Syncope, Vasovagal/physiopathology , Syncope, Vasovagal/surgery , Syncope, Vasovagal/diagnosis , Europe , Catheter Ablation/methods , Workflow , Heart Rate , Treatment Outcome , Health Care Surveys , Practice Patterns, Physicians'/trends , Electrophysiologic Techniques, Cardiac , Surveys and Questionnaires , Ganglia, Autonomic/surgery , Ganglia, Autonomic/physiopathology , Heart Atria/physiopathology , Heart Atria/surgery , Recurrence
3.
Heart Rhythm ; 2024 Apr 11.
Article in English | MEDLINE | ID: mdl-38614191

ABSTRACT

BACKGROUND: Pulsed-field ablation (PFA) has shown promising data in terms of safety and procedural efficiency for pulmonary vein isolation (PVI), with similar long-term outcomes compared to radiofrequency ablation (RFA) and cryoballoon ablation (CBA) in patients with paroxysmal atrial fibrillation (AF). OBJECTIVE: The purpose of this study was to compare the procedural and long-term outcomes in patients with persistent AF undergoing PVI using PFA, CBA, or RFA. METHODS: Consecutive patients with persistent AF undergoing first PVI with PFA, CBA, or RFA were included. Patients underwent 7-day Holter electrocardiography at 3, 6, and 12 months postablation. The primary outcome was recurrence of any atrial arrhythmia after a 90-day blanking period. Safety outcomes included the composite of in-hospital major adverse events. RESULTS: A total of 533 patients with persistent AF underwent PVI using PFA (n = 214, 39%), CBA (n = 190, 36%), or RFA (n = 129, 24%). Procedures with PFA guided by fluoroscopy were shorter than those with CBA (median 60 minutes; interquartile range [IQR] 53-80 minutes vs 84 minutes; IQR 68-101 minutes; P ≤ .001), and procedures with PFA in combination with 3-dimensional electroanatomic mapping were shorter than those with RFA (median 101 minutes; IQR 85-126 minutes vs 171 minutes; IQR 141-204 minutes; P < .001). Acute safety events occurred in 2.3%, 2.6%, and 0.8% in the PFA, CBA, and RFA groups, respectively (P = .545). The 1-year confounder-adjusted estimate for freedom from atrial arrhythmias was 62.1% for CBA, 55.3% for PFA, and 48.3% for RFA (CBA vs PFA: P = .79; CBA vs RFA: P = .009; PFA vs RFA: P = .010). CONCLUSION: In patients with persistent AF undergoing first PVI, 1-year confounder-adjusted outcomes are better with PFA and CBA than with RFA.

4.
Article in English | MEDLINE | ID: mdl-38639700

ABSTRACT

BACKGROUND: Recurrence of paroxysmal atrial fibrillation (AF) following pulmonary vein isolation (PVI) is presumably caused by pulmonary vein (PV) reconnections. However, there is little data available on the durability of PVI and incidence of arrhythmia recurrence in patients with persistent AF. OBJECTIVES: To evaluate the lesion durability by means of an a priori planned remapping procedure in patients with persistent AF undergoing CLOSE-guided PVI. METHODS: In a prospective study, we included patients with symptomatic, persistent AF undergoing CLOSE-guided radiofrequency ablation. Irrespective of AF recurrence, a redo procedure was mandated 6 months following the index procedure to evaluate PV reconnections. The outcome of AF ablation was based on clinical recurrence and 7-day Holter electrocardiogram 3 and 6 months after the index procedure and 3, 6, and 12 months after the redo procedure. RESULTS: Of 30 patients included, 26 (81% men; median age 68 years) underwent the planned remapping study a median of 6 months after the index procedure, whereas 4 patients without recurrence refused a repeat procedure. In total, 78 of 102 (76%) PVs showed durable isolation and 15 patients (58%) presented complete isolation of all PVs. Beyond the blanking period, 6 of 26 patients (23%) had arrhythmia recurrence before the redo procedure. Recurrence had occurred in 33% of patients with complete isolation of all veins and in 9% of patients with PV reconnections (P = 0.197). After re-PVI in patients with PV reconnections and additional ablation in patients with recurrence but durable PVI, 17 of 26 patients (65%) were free of arrhythmia after 12 months. CONCLUSIONS: In patients with persistent AF, CLOSE-guided PVI resulted in durable rate of PVI on a per-vein and per-patient level of 76% and 58%, respectively. Arrhythmia recurrence was numerically higher in patients with durable PVI compared with patients without.

5.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38597211

ABSTRACT

AIMS: Pulmonary vein isolation (PVI) is increasingly performed in patients with atrial fibrillation (AF). Both AF phenotype and left atrial (LA) volume have been shown to influence ablation outcome. The inter-relationship of the two is incompletely understood. We aimed to investigate the impact of AF phenotype vs. LA volume on outcome after PVI. METHODS AND RESULTS: In a retrospective analysis of a prospective registry of patients undergoing a first PVI, the association of AF phenotype and LA volume index (LAVI) was assessed as well as their impact on AF recurrence during follow-up. Overall, 476 patients were enrolled (median age 63 years, 29% females, 65.8% paroxysmal AF). Obesity, hypertension, chronic kidney disease, and heart failure were all significantly more frequent in persistent AF. After 1 year, single-procedure, freedom from arrhythmia recurrence was 61.5%. Patients with paroxysmal AF had better outcomes compared with patients with persistent AF (65.6 vs. 52.7%, P = 0.003), as had patients with no/mild vs. moderate/severe LA dilation (LAVI <42 mL/m2 67.1% vs. LAVI ≥42 mL/m2 53%, P < 0.001). The combination of both parameters refined prediction of 1-year recurrence (P < 0.001). After adjustment for additional clinical risk factors in multivariable Cox proportional hazard analysis, both AF phenotype and LAVI ≥42 mL/m2 contributed significantly towards the prediction of 1-year recurrence. CONCLUSION: Atrial fibrillation phenotype and LA volume are independent predictors of outcome after PVI. Persistent AF with no/mild LA dilation has a similar risk of recurrence as paroxysmal AF with a moderate/severe LA dilation and should be given similar priority for ablation.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Female , Humans , Middle Aged , Male , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/etiology , Pulmonary Veins/surgery , Retrospective Studies , Treatment Outcome , Heart Atria/diagnostic imaging , Heart Atria/surgery , Phenotype , Recurrence , Catheter Ablation/adverse effects , Catheter Ablation/methods
6.
Article in English | MEDLINE | ID: mdl-38655610

ABSTRACT

AIMS: Pacemaker (PM) patients may require a subsequent upgrade to an implantable cardioverter defibrillator (ICD). Limited data exists on this patient population. We sought to characterize this population, to assess predictors for ICD upgrade, and to report the outcome. METHODS: From our prospective PM and ICD implantation registry, all patients who underwent PM and/or ICD implantations at our center were analyzed. Patient characteristics and outcomes of PM patients with subsequent ICD upgrade were compared to age- and sex-matched patients with de novo ICD implantation, and to PM patients without subsequent upgrade. RESULTS: Of 1'301 ICD implantations, 60 (5%) were upgraded from PMs. Median time from PM implantation to ICD upgrade was 2.6 years (IQR 1.3-5.4). Of 2'195 PM patients, 28 patients underwent subsequent ICD upgrades, corresponding to an estimated annual incidence of an ICD upgrade of at least 0.33%. Lower LVEF (p = .05) and male sex (p = .038) were independent predictors for ICD upgrade. Survival without death, transplant and LVAD implantation were worse both for upgraded ICD patients compared to matched patients with de novo ICD implantation (p = .05), as well as for PM patients with subsequent upgrade compared to matched PM patients not requiring an upgrade (p = .036). CONCLUSIONS: One of 20 ICD implantations are upgrade of patients with a PM. At least one of 30 PM patients will require an ICD upgrade in the following 10 years. Predictors for ICD upgrade are male sex and lower LVEF at PM implantation. Upgraded patients have worse outcomes.

7.
Article in English | MEDLINE | ID: mdl-38430087

ABSTRACT

BACKGROUND: Pulmonary vein isolation (PVI) alone is insufficient to treat many patients with persistent atrial fibrillation (PersAF). Adjunctive left atrial posterior wall (LAPW) ablation with thermal technologies has revealed lack of efficacy, perhaps limited by the difficulty in achieving lesion durability amid concerns of esophageal injury. OBJECTIVES: This study aims to compare the safety and effectiveness of PVI + LAPW ablation vs PVI in patients with PersAF using pulsed-field ablation (PFA). METHODS: In a retrospective analysis of the MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-approval Clinical Use of Pulsed Field Ablation) registry, we studied consecutive PersAF patients undergoing post-approval treatment with a pentaspline PFA catheter. The primary effectiveness outcome was freedom from any atrial arrhythmia of ≥30 seconds. Safety outcomes included the composite of acute and chronic major adverse events. RESULTS: Of the 547 patients with PersAF who underwent PFA, 131 (24%) received adjunctive LAPW ablation. Compared to PVI-alone, patients receiving adjunctive LAPW ablation were younger (65 vs 67 years of age, P = 0.08), had a lower CHA2DS2-VASc score (2.3 ± 1.6 vs 2.6 ± 1.6, P = 0.08), and were more likely to receive electroanatomical mapping (48.1% vs 39.0%, P = 0.07) and intracardiac echocardiography imaging (46.1% vs 17.1%, P < 0.001). The 1-year Kaplan-Meier estimate for freedom from atrial arrhythmias was not statistically different between groups in the full (PVI + LAPW: 66.4%; 95% CI: 57.6%-74.4% vs PVI: 73.1%; 95% CI: 68.5%-77.2%; P = 0.68) and propensity-matched cohorts (PVI + LAPW: 71.7% vs PVI: 68.5%; P = 0.34). There was also no significant difference in major adverse events between the groups (2.2% vs 1.4%, respectively, P = 0.51). CONCLUSIONS: In patients with PersAF undergoing PFA, as compared to PVI-alone, adjunctive LAPW ablation did not improve freedom from atrial arrhythmia at 12 months.

8.
JACC Clin Electrophysiol ; 10(4): 698-708, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38340118

ABSTRACT

BACKGROUND: Pulsed-field ablation (PFA) is a novel nonthermal ablation technology with high procedural safety and efficiency for pulmonary vein isolation (PVI). Premarket data showed high PVI durability during mandatory remapping studies. Data on lesion durability in real-world patients with clinically indicated redo procedures are scarce. OBJECTIVES: This study sought to report PVI durability rates in patients undergoing a clinically indicated redo procedure after an index PVI using PFA. METHODS: Patients from 7 European centers undergoing an index PVI using PFA were included the EU-PORIA (European Real-world Outcomes With Pulsed Field Ablation in Patients With Symptomatic Atrial Fibrillation) registry. In patients with subsequent left atrial redo procedures due to arrhythmia recurrence, 3-dimensional electroanatomical maps were acquired. PVI durability was assessed on a per-vein and per-patient level, and sites of reconnections and predictors of lesion durability were identified. RESULTS: Of 1,184 patients (62% paroxysmal atrial fibrillation) undergoing an index PVI using PFA, 272 (23%) had an arrhythmia recurrence. Of these, 144 (53%) underwent a left atrial redo procedure a median of 7 (Q1-Q3: 5-10) months after the first ablation. Three-dimensional electroanatomical maps identified 404 of 567 pulmonary veins (71%) with durable isolation. In 54 patients (38%), all pulmonary veins were durably isolated. Prior operator experience with cryoballoon ablation was associated with a higher PVI durability compared to operators with only point-by-point radiofrequency experience (76% vs 60%; P < 0.001). Neither the operators' cumulative experience in atrial fibrillation ablation (≤5 vs >5 years) nor the size of the PFA device used (31 mm vs 35 mm) had an impact on subsequent lesion durability (both P > 0.50). CONCLUSIONS: In 144 patients with arrhythmia recurrence after PFA PVI, durable isolation was observed in 71% of the pulmonary veins during the redo procedure, and 38% of all patients showed durable isolation of all veins.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Registries , Humans , Pulmonary Veins/surgery , Atrial Fibrillation/surgery , Male , Female , Middle Aged , Catheter Ablation/methods , Aged , Europe , Treatment Outcome , Recurrence , Reoperation/statistics & numerical data
9.
J Am Heart Assoc ; 13(4): e032223, 2024 Feb 20.
Article in English | MEDLINE | ID: mdl-38348803

ABSTRACT

BACKGROUND: Screening for atrial fibrillation (AF) may reveal incidental arrhythmias of relevance. The aim of this study was to describe incidental arrhythmias detected during screening for AF in the STAR-FIB (Predicting SilenT AtRial FIBrillation in Patients at High Thrombembolic Risk) cohort study. METHODS AND RESULTS: In the STAR-FIB cohort study, we screened hospitalized patients for AF with 3 repeat 7-day Holter ECGs. We analyzed all Holter ECGs for the presence of the following incidental arrhythmias: (1) sinus node dysfunction, defined as sinus pause of ≥3 seconds' duration; (2) second-degree (including Wenckebach) or higher-degree atrioventricular block (AVB); (3) sustained supraventricular tachycardia of ≥30 seconds' duration; and (4) sustained ventricular tachycardia of ≥30 seconds' duration. We furthermore report treatment decisions because of incidental arrhythmias. A total of 2077 Holter ECGs were performed in 794 patients (mean age, 74.7 years; 49% women), resulting in a mean cumulative duration of analyzable ECG signal of 414±136 hours/patient. We found incidental arrhythmias in 94 patients (11.8%). Among these were sinus node dysfunction in 14 patients (1.8%), AVB in 41 (5.2%), supraventricular tachycardia in 42 (5.3%), and ventricular tachycardia in 2 (0.3%). Second-degree AVB was found in 23 patients (2.9%), 2:1 AVB in 10 (1.3%), and complete AVB in 8 (1%). Subsequently, 8 patients underwent pacemaker implantation, 1 for sinus node dysfunction (post-AF conversion pause of 9 seconds) and 7 for advanced AVB. One patient had an implantable cardioverter-defibrillator implanted for syncopal ventricular tachycardia. CONCLUSIONS: Incidental arrhythmias were frequently detected during screening for AF in the STAR-FIB study and resulted in device therapy in 1.1% of our cohort patients.


Subject(s)
Atrial Fibrillation , Atrioventricular Block , Defibrillators, Implantable , Tachycardia, Supraventricular , Tachycardia, Ventricular , Humans , Female , Aged , Male , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Electrocardiography, Ambulatory , Cohort Studies , Sick Sinus Syndrome , Atrioventricular Block/diagnosis , Atrioventricular Block/epidemiology , Atrioventricular Block/therapy , Tachycardia, Supraventricular/diagnosis , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/epidemiology , Tachycardia, Ventricular/etiology , Hospitals
10.
Europace ; 26(2)2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38363995

ABSTRACT

Ventricular tachycardia (VT), and its occurrence, is still one of the main reasons for sudden cardiac death and, therefore, for increased mortality and morbidity foremost in patients with structural heart [Kahle A-K, Jungen C, Alken F-A, Scherschel K, Willems S, Pürerfellner H et al. Management of ventricular tachycardia in patients with ischaemic cardiomyopathy: contemporary armamentarium. Europace 2022;24:538-51]. Catheter ablation has become a safe and effective treatment option in patients with recurrent VT [Cronin EM, Bogun FM, Maury P, Peichl P, Chen M, Namboodiri N et al. 2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias. Heart Rhythm 2020;17:e2-154]. Previous and current guidelines provide guidance on indication for VT ablation and risk assessment and evaluation of underlying disease. However, no uniform recommendation is provided regarding procedural strategies, timing of ablation, and centre setting. Therefore, these specifics seem to differ largely, and recent data are sparse. This physician-based European Heart Rhythm Association survey aims to deliver insights on not only infrastructural settings but also procedural specifics, applied technologies, ablation strategies, and procedural endpoints. Therefore, these findings might deliver a real-world scenario of VT management and potentially are of guidance for other centres.


Subject(s)
Catheter Ablation , Myocardial Ischemia , Tachycardia, Ventricular , Humans , Workflow , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Arrhythmias, Cardiac/surgery , Treatment Outcome , Catheter Ablation/methods
11.
Eur Stroke J ; 9(2): 441-450, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38288699

ABSTRACT

INTRODUCTION: Covert brain infarcts (CBI) are frequent incidental findings on MRI and associated with future stroke risk in patients without a history of clinically evident cerebrovascular events. However, the prognostic value of CBI in first-ever ischemic stroke patients is unclear and previous studies did not report on different etiological stroke subtypes. We aimed to test CBI phenotypes and their association with stroke recurrence in first-ever ischemic stroke patients according to stroke etiology. PATIENTS AND METHODS: This study is a pooled data analysis of two prospectively collected cohorts of consecutive first-ever ischemic stroke patients admitted to the comprehensive stroke centers of Bern (Switzerland) and Graz (Austria). CBI phenotypes were identified on brain MRI within 72 h after admission. All patients underwent a routine follow-up (median: 12 months) to identify stroke recurrence. RESULTS: Of 1577 consecutive ischemic stroke patients (median age: 71 years), 691 patients showed CBI on brain MRI (44%) and 88 patients had a recurrent ischemic stroke (6%). Baseline CBI were associated with stroke recurrence in multivariable analysis (HR 1.9, 95% CI 1.1-3.3). CBI phenotypes with the highest risk for stroke recurrence were cavitatory CBI in small vessel disease (SVD)-related stroke (HR 7.1, 95% CI 1.6-12.6) and cortical CBI in patients with atrial fibrillation (HR 3.0, 95% CI 1.1-8.1). DISCUSSION AND CONCLUSION: This study reports a ≈ 2-fold increased risk for stroke recurrence in first-ever ischemic stroke patients with CBI. The risk of recurrent stroke was highest in patients with cavitatory CBI in SVD-related stroke and cortical CBI in patients with atrial fibrillation.Subject terms: Covert brain infarcts, stroke.


Subject(s)
Brain Infarction , Ischemic Stroke , Magnetic Resonance Imaging , Phenotype , Recurrence , Humans , Female , Male , Aged , Ischemic Stroke/diagnostic imaging , Ischemic Stroke/pathology , Ischemic Stroke/etiology , Middle Aged , Brain Infarction/pathology , Brain Infarction/diagnostic imaging , Brain Infarction/epidemiology , Brain Infarction/complications , Aged, 80 and over , Risk Factors , Prospective Studies , Brain Ischemia/pathology , Brain Ischemia/diagnostic imaging , Brain Ischemia/etiology , Brain Ischemia/epidemiology , Stroke/pathology , Stroke/diagnostic imaging , Stroke/etiology , Stroke/epidemiology , Brain/pathology , Brain/diagnostic imaging
12.
Eur Radiol ; 2024 Jan 10.
Article in English | MEDLINE | ID: mdl-38197916

ABSTRACT

OBJECTIVES: Epicardial adipose tissue (EAT) remodeling is associated with atrial fibrillation (AF). Left atrial (LA) EAT dispersion on cardiac CT is a non-invasive imaging biomarker reflecting EAT heterogeneity. We aimed to investigate the association of LA EAT dispersion with AF recurrence after pulmonary vein isolation (PVI). METHODS: In a prospective registry of consecutive patients undergoing first PVI, mean EAT attenuation values were measured on contrast-enhanced cardiac CT scans in Hounsfield units (HU) within low (- 195 to - 45 HU) and high (- 44 to - 15 HU) threshold EAT compartments around the left atrium (LA). EAT dispersion was defined as the difference between the mean HU values within the two EAT compartments. Continuous variables were compared between groups using the Mann-Whitney U test and cox proportional hazard models were used to calculate hazard ratios of predictors of 1-year AF recurrence. RESULTS: A total of 208 patients were included, 135 with paroxysmal AF and 73 with persistent AF. LA EAT dispersion was significantly larger in patients with persistent compared to paroxysmal AF (52.6 HU vs. 49.9 HU; p = 0.001). After 1 year of follow-up, LA EAT dispersion above the mean (> 50.8 HU) was associated with a higher risk of AF recurrence (HR 2.3, 95% CI 1.5-3.6; p < 0.001). It retained its predictive value when corrected for age, sex, body mass index, LA volume, and AF type (HR 2.8, 95% CI 1.6-4.6; p < 0.001). CONCLUSION: A larger LA EAT dispersion on contrast-enhanced cardiac CT scans, reflecting EAT heterogeneity, is independently associated with AF recurrence after PVI. CLINICAL RELEVANCE STATEMENT: Based on LA EAT dispersion assessment, a more accurate risk stratification and patient selection may be possible based on a pre-procedural cardiac CT when planning PVI. KEY POINTS: • Epicardial adipose tissue (EAT) remodeling is associated with atrial fibrillation (AF). • A larger left atrial EAT dispersion in a pre-procedural cardiac CT was associated with a higher 1-year AF recurrence risk after pulmonary vein isolation. • A pre-procedural cardiac CT with left atrial EAT dispersion assessment may provide a more accurate risk stratification and patient selection for PVI.

13.
J Interv Card Electrophysiol ; 67(3): 503-511, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37523023

ABSTRACT

BACKGROUND: A novel multipolar pulsed-field ablation (PFA) catheter has recently been introduced for pulmonary vein isolation (PVI). Pre-market data showed high rates for PVI-durability during mandatory remapping studies. OBJECTIVE: To present post-market data in patients with recurrent arrhythmias. METHODS: Consecutive patients undergoing a redo procedure after an index PFA PVI using a bipolar-biphasic PFA system were included. 3-D electro-anatomical maps (3D-EAM) on redo procedure were compared to the 3D-EAM acquired after ablation during the index procedure. PVI durability was assessed on a per-vein and per-patient level and the sites of reconnections were identified. Furthermore, lesion extent around veins with durable isolation was compared to study lesion regression. RESULTS: Of 341 patients treated with a PFA PVI, 29 (8.5%) underwent a left atrial redo ablation due to arrhythmia recurrence. At the end of the index procedure, 110/112 veins (98%, four common ostia) were isolated. On redo procedures performed a median of 6 months after the first ablation, 3D-EAM identified 69/110 (63%) PVs with durable isolation. In 6 (21%) patients, all PVs were durably isolated. Reconnections were more often found on the right-sided veins and on the anterior aspects of the upper veins. Only minor lesion regression was observed between the index and redo procedure (a median of 3 mm (0 - 9.5) on the posterior wall). CONCLUSION: In patients with arrhythmia recurrence after PFA PVI using a first-generation PFA device, durable isolation was observed in 63% of the veins and 21% of the patients showed durable isolation of all previously isolated veins.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Heart Atria/surgery , Cryosurgery/methods , Reoperation/methods , Catheter Ablation/methods , Treatment Outcome , Recurrence
14.
J Interv Card Electrophysiol ; 67(2): 389-397, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37776355

ABSTRACT

BACKGROUND: Pulsed-field ablation (PFA) has shown favourable data in terms of safety and procedural efficiency for pulmonary vein isolation (PVI). We sought to compare procedural and 1-year follow-up data of patients with paroxysmal atrial fibrillation (AF) undergoing PVI using PFA, cryoballoon ablation (CBA) and radiofrequency ablation (RFA). METHODS: Consecutive patients with paroxysmal AF undergoing a first PVI with PFA at our institution were included. For comparison, patients with paroxysmal AF undergoing a first PVI with CBA and RFA were selected using a 1:2:2 propensity score matching. The PFA group followed the standard 32-applications lesion-set protocol, the CBA group a time-to-effect plus 2-min strategy, and the RFA group the CLOSE protocol. Patients were followed with 7d-Holter ECGs 3, 6, and 12 months after ablation. The primary endpoint was recurrence of atrial tachyarrhythmia (ATa) following a blanking period of 3 months. RESULTS: A total of 200 patients were included (PFA n = 40; CBA n = 80; RFA n = 80). Median procedure times were shortest with CBA (75 min) followed by PFA (94 min) and RFA (182 min; p < 0.001). Fluoroscopy dose was lowest with RFA (1.6Gycm2) followed by PFA (5.0Gycm2) and CBA (5.7Gycm2; p < 0.001). After a 1-year follow-up, freedom from ATa recurrence was 85.0% with PFA, 66.2% with CBA and 73.8% with RFA (p = 0.12 PFA vs. CBA; p = 0.27 PFA vs. RFA). CONCLUSION: In a propensity score matched analysis of patients with paroxysmal AF, freedom from any ATa 1 year after PVI using PFA was favourable and at least as good as for PVI with CBA or RFA.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Radiofrequency Ablation , Humans , Atrial Fibrillation/surgery , Pulmonary Veins/surgery , Propensity Score , Treatment Outcome , Cryosurgery/methods , Catheter Ablation/methods , Recurrence
15.
Europace ; 26(1)2023 12 28.
Article in English | MEDLINE | ID: mdl-38091971

ABSTRACT

Limited data are available regarding venous thromboembolism (VTE), specifically deep vein thrombosis (DVT) and pulmonary embolism (PE), following right-sided ablations and electrophysiological (EP) studies. Compared to left-sided procedures, no guidelines on antithrombotic management strategies for the prevention of DVT and PE are available. The main purpose of the present European Heart Rhythm Association (EHRA) survey is to report the current management of right-sided EP procedures, focusing on anticoagulation and prevention of VTE. An online survey was conducted using the EHRA infrastructure. A total of 244 participants answered a 19-items questionnaire on the periprocedural management of EP studies and right-sided catheter ablations. The right femoral vein is the most common access for EP studies and right-sided procedures. An ultrasound-guided approach is employed by more than 2/3 of respondents. Intravenous heparin is not commonly given by the majority of participants. About 1/3 of participants (34%) routinely prescribe VTE prophylaxis during (mostly aspirin and low molecular weight heparin) and 1/4 of respondents (25%) commonly prescribe VTE prophylaxis after discharge (mostly aspirin). Of note, respectively 13% and 9% of participants observed at least one DVT and one PE related to right-sided ablation or EP study within the last year in their center. The present survey shows that only a minority of operators routinely gives intraprocedural intravenous heparin and prescribes VTE prophylaxis after right-sided EP procedures. Compared to left-sided procedures like atrial fibrillation (AF) ablation, there are no consistent systematic antithrombotic management strategies.


Subject(s)
Pulmonary Embolism , Venous Thromboembolism , Humans , Venous Thromboembolism/epidemiology , Venous Thromboembolism/prevention & control , Anticoagulants/therapeutic use , Fibrinolytic Agents/therapeutic use , Heparin , Pulmonary Embolism/prevention & control , Pulmonary Embolism/drug therapy , Aspirin , Surveys and Questionnaires
16.
JAMA Cardiol ; 8(12): 1142-1151, 2023 12 01.
Article in English | MEDLINE | ID: mdl-37910101

ABSTRACT

Importance: Previous studies evaluating the association of patient sex with clinical outcomes using conventional thermal ablative modalities for atrial fibrillation (AF) such as radiofrequency or cryoablation are controversial due to mixed results. Pulsed field ablation (PFA) is a novel AF ablation energy modality that has demonstrated preferential myocardial tissue ablation with a unique safety profile. Objective: To compare sex differences in patients undergoing PFA for AF in the Multinational Survey on the Methods, Efficacy, and Safety on the Postapproval Clinical Use of Pulsed Field Ablation (MANIFEST-PF) registry. Design, Setting, and Participants: This was a retrospective cohort study of MANIFEST-PF registry data, which included consecutive patients undergoing postregulatory approval treatment with PFA to treat AF between March 2021 and May 2022 with a median follow-up of 1 year. MANIFEST-PF is a multinational, retrospectively analyzed, prospectively enrolled patient-level registry including 24 European centers. The study included all consecutive registry patients (age ≥18 years) who underwent first-ever PFA for paroxysmal or persistent AF. Exposure: PFA was performed on patients with AF. All patients underwent pulmonary vein isolation and additional ablation, which was performed at the discretion of the operator. Main Outcomes and Measures: The primary effectiveness outcome was freedom from clinically documented atrial arrhythmia for 30 seconds or longer after a 3-month blanking period. The primary safety outcome was the composite of acute (<7 days postprocedure) and chronic (>7 days) major adverse events (MAEs). Results: Of 1568 patients (mean [SD] age, 64.5 [11.5] years; 1015 male [64.7%]) with AF who underwent PFA, female patients, as compared with male patients, were older (mean [SD] age, 68 [10] years vs 62 [12] years; P < .001), had more paroxysmal AF (70.2% [388 of 553] vs 62.4% [633 of 1015]; P = .002) but had fewer comorbidities such as coronary disease (9% [38 of 553] vs 15.9% [129 of 1015]; P < .001), heart failure (10.5% [58 of 553] vs 16.6% [168 of 1015]; P = .001), and sleep apnea (4.7% [18 of 553] vs 11.7% [84 of 1015]; P < .001). Pulmonary vein isolation was performed in 99.8% of female (552 of 553) and 98.9% of male (1004 of 1015; P = .90) patients. Additional ablation was performed in 22.4% of female (124 of 553) and 23.1% of male (235 of 1015; P = .79) patients. The 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was similar in male and female patients (79.0%; 95% CI, 76.3%-81.5% vs 76.3%; 95% CI, 72.5%-79.8%; P = .28). There was also no significant difference in acute major AEs between groups (male, 1.5% [16 of 1015] vs female, 2.5% [14 of 553]; P = .19). Conclusion and Relevance: Results of this cohort study suggest that after PFA for AF, there were no significant sex differences in clinical effectiveness or safety events.


Subject(s)
Atrial Fibrillation , Humans , Male , Female , Middle Aged , Aged , Adolescent , Atrial Fibrillation/drug therapy , Retrospective Studies , Cohort Studies , Sex Factors , Treatment Outcome
17.
Article in English | MEDLINE | ID: mdl-37851866

ABSTRACT

AIMS: Implantation of an implantable cardiac monitor (ICM) is a simple procedure, but adds significant and increasing workload to the arrhythmia service. In 2020, we established a nurse-led ICM implantation service. We aimed to analyze patient satisfaction, adverse events during implant and ICM re-interventions with nurse-led ICM implantation (N-Implant) compared to physician-led ICM implantation (P-Implant). METHOD AND RESULTS: From January 2020 to December 2021 we included all consecutive patients implanted with an ICM in a prospective registry. We collected data on patient characteristics, implant procedure and follow-up. Patients were interviewed by phone four weeks after ICM implantation.Of 321 patients implanted with an ICM (median age 67 years; 33% women), 189 (59%) were N-Implants. More N-Implants were performed in the outpatient clinic compared to P-Implants (95% vs. 8%; p<0.001). Two N-Implant patients experienced vaso-vagal reaction during implantation (1%), whereas no adverse events occurred during P-Implant (p=0.51). 297 patients (93%) completed the questionnaire. Duration of pain was shorter and wound closure after 2 weeks better following N-Implant (p=0.019 and p=0.018). A minor bruise or swelling at the implant site was reported more frequently after N-Implant (p=0.003 and p=0.041). Patient satisfaction was excellent with both N-Implant and P-Implant (99% and 97%; p=0.16). After a median follow-up of 242 days (range 7-725 days), five ICMs (2%) were explanted prematurely, without differences among groups. Reasons for premature explants were local discomfort (n=2), infection, MRI and ICM malfunction. CONCLUSION: Nurse-led ICM implantation has excellent patient satisfaction without compromising safety. N-Implant both expands nursing competencies and reduces physician workload.

18.
Contemp Clin Trials ; 134: 107341, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37722483

ABSTRACT

INTRODUCTION: Single-shot devices are increasingly used for pulmonary vein isolation (PVI) in atrial fibrillation (AF). The Arctic Front cryoballoon (Medtronic) is the most frequently used single-shot technology. A recently developed novel cryoballoon has been introduced (PolarX, Boston Scientific) with the aim to address limitations of the Arctic Front system. METHODS: COMPARE CRYO is a multicentre, randomized, controlled trial with blinded endpoint adjudication by an independent clinical events committee. A total of 200 patients with paroxysmal AF undergoing their first PVI are randomized 1:1 between PolarX cryoballoon ablation and Arctic Front cryoballoon ablation. Continuous monitoring during follow-up is performed using an implantable cardiac monitor (ICM) in all patients. The primary endpoint is time to first recurrence of any atrial tachyarrhythmia (AF, atrial flutter, and/or atrial tachycardia) ≥ 120 s between days 91 and 365 post ablation as detected on the (ICM). Procedural safety is assessed by a composite of cardiac tamponade, persistent phrenic nerve palsy >24 h, vascular complications requiring intervention, stroke/transient ischemic attack, atrioesophageal fistula or death occurring during or up to 30 days after the procedure. Key secondary endpoints include (1) procedure and fluoroscopy times, (2) AF burden, (3) proportion of patients with recurrence in the blanking period, (4) proportion of patients undergoing repeat ablation, and (5) quality of life changes at 12 months compared to baseline. CONCLUSION: COMPARE CRYO will compare the efficacy and safety of the novel PolarX cryoballoon and the standard-of-practice Arctic Front cryoballoon for first PVI performed in patients with symptomatic paroxysmal AF. TRIAL REGISTRATION: (ClinicalTrials.gov ID: NCT04704986).


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Humans , Atrial Fibrillation/surgery , Treatment Outcome , Pulmonary Veins/surgery , Quality of Life , Cryosurgery/methods , Catheter Ablation/methods , Recurrence , Randomized Controlled Trials as Topic , Multicenter Studies as Topic
19.
J Am Heart Assoc ; 12(17): e030037, 2023 09 05.
Article in English | MEDLINE | ID: mdl-37609989

ABSTRACT

Background The interrelationships between left atrial appendage (LAA) dimensions and device following implantation are unknown. We aimed to analyze the impact of Watchman device implantation on LAA dimensions following its percutaneous closure and potential predictors of remodeling. Methods and Results All consecutive LAA closure procedures performed at 2 centers between November 2017 and December 2020 were included in the WATCH-DUAL (Watchman 2.5 Versus Watchman FLX in a Dual-Center Left Atrial Appendage Closure Cohort) registry. This study included patients who had pre- and postintervention computed tomography scan analysis. The LAA and device dimensions were measured in a centralized core lab by 3-dimensional computed tomography scan reconstruction methods, focusing on the device landing zone. This analysis included 104 patients (age, 76.0 [range, 72.0-83.0] years; 72% men; 53% Watchman FLX; 47% Watchman 2.5). The baseline characteristics were comparable between Watchman 2.5 and Watchman FLX groups, except for the higher use of oversizing in the latter group. The median delay for computed tomography control was 49 (range, 43-64) days. The landing zone area (median, 446 [range, 363-523] versus 290 [222-366] mm2; P<0.001) and minimal diameter (median, 23.0 [range, 20.7-24.8] versus 16.7 [14.7-19.4] mm; P<0.001) significantly increased after implantation. The absolute (median, 157 [range, 98-220] versus 85 [18-148] mm2, P<0.001) and relative (median, 50% [range, 32%-79%] versus 26% [4%-50%]; P<0.001) increases in landing zone area were more pronounced in patients with oversized device. Baseline LAA dimensions were smaller, landing zone eccentricity larger, and oversized device more frequent in patients with significant overexpansion compared with the others. Conclusions LAA dimensions increased at the site of the Watchman prosthesis after implantation, suggesting a local positive remodeling after the procedure. This phenomenon was more pronounced in the case of oversized devices.


Subject(s)
Atrial Appendage , Atrial Remodeling , Male , Humans , Aged , Female , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Prosthesis Implantation , Registries , Tomography, X-Ray Computed
20.
Pacing Clin Electrophysiol ; 46(10): 1186-1196, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37616339

ABSTRACT

BACKGROUND: Prediction of the chamber of origin in patients with outflow tract ventricular arrhythmias (OTVA) remains challenging. A clinical risk score based on age, sex and presence of hypertension was associated with a left ventricular outflow tract (LVOT) origin. We aimed to validate this clinical score to predict an LVOT origin in patients with OTVA. METHODS: In a two-center observational cohort study, unselected patients undergoing catheter ablation (CA) for OTVA were enrolled. All procedures were performed using an electroanatomical mapping system. Successful ablation was defined as a ≥80% reduction of the initial overall PVC burden after 3 months of follow-up. Patients with unsuccessful ablation were excluded from this analysis. RESULTS: We included 187 consecutive patients with successful CA of idiopathic OTVA. Mean age was 52 ± 15 years, 102 patients (55%) were female, and 74 (40%) suffered from hypertension. A LVOT origin was found in 64 patients (34%). A score incorporating age, sex and presence of hypertension reached 73% sensitivity and 67% specificity for a low (0-1) and high (2-3) score, to predict an LVOT origin. The combination of one ECG algorithm (V2 S/V3 R-index) with the clinical score resulted in a sensitivity and specificity of 81% and 70% for PVCs with R/S transition at V3 . CONCLUSION: The published clinical score yielded a lower sensitivity and specificity in our cohort. However, for PVCs with R/S transition at V3, the combination with an existing ECG algorithm can improve the predictability of LVOT origin.

SELECTION OF CITATIONS
SEARCH DETAIL
...