Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Eur Heart J Case Rep ; 5(7): ytab263, 2021 Jul.
Article in English | MEDLINE | ID: mdl-34377911

ABSTRACT

BACKGROUND: Antithrombotic management in patients with atrial fibrillation (AF) that have undergone heart valve surgery may be challenging, especially in the context of thromboembolic events during follow-up. The combination of pharmacological therapies with modern transcatheter interventions allows these more complex cases to be overcome. CASE SUMMARY: We present the case of a 66-year-old female with a history of AF and mechanical aortic and mitral valve replacement, which was admitted to the hospital complaining of dizziness and unsteady gait. A computerized tomography scan of the brain confirmed the diagnosis of embolic stroke. Two years later, the patient complained of sudden onset of chest pain, accompanied by electrocardiographic abnormalities and elevated high-sensitivity troponin T. Emergency cardiac catheterization revealed embolic myocardial infarction with distal occlusion of the obtuse marginal artery. Again, 2 years later, the patient suffered a new cerebral embolic event. Given the adequate anticoagulation therapy throughout almost the entire clinical course, percutaneous left atrial appendage closure was proposed as an adjunct to vitamin K antagonist treatment. Notably, intraprocedural transoesophageal echocardiography revealed the presence of a previously undetected left atrial appendage thrombus, thus an embolic protection device was used during the procedure, which was successfully carried out without complications. DISCUSSION: This case report demonstrates the complexity of the antithrombotic management in patients with AF and prosthetic heart valves, and highlights the importance of an individualized approach, integrating new therapeutic strategies to achieve success, in patients that present thromboembolic events despite adequate anticoagulation therapy.

2.
Echocardiography ; 38(6): 1089-1092, 2021 06.
Article in English | MEDLINE | ID: mdl-34013545

ABSTRACT

In this rare case of intrahepatic cholangiocarcinoma (ICC) tumor thrombus with right atrial (RA) invasion, we describe its diagnostic workup based on cardiac magnetic resonance imaging (cMRI). An 85-year-old man underwent transthoracic echocardiography due to dyspnea, revealing a RA mass. Comprehensive cMRI evaluation, including cine bright blood, T1- and T2-weighed, fat-suppressed, and contrast-enhanced imaging, was performed and diagnosis of ICC tumor thrombus with RA invasion was made. This first description of cMRI-guided diagnosis of RA invasion by ICC tumor thrombus points out the usefulness of cMRI for the diagnostic approach of RA masses suggestive of tumor thrombus.


Subject(s)
Bile Duct Neoplasms , Cholangiocarcinoma , Aged, 80 and over , Bile Duct Neoplasms/diagnostic imaging , Bile Ducts, Intrahepatic , Cholangiocarcinoma/diagnostic imaging , Heart Atria/diagnostic imaging , Humans , Magnetic Resonance Imaging , Male
3.
Circ J ; 82(11): 2880-2886, 2018 10 25.
Article in English | MEDLINE | ID: mdl-30135324

ABSTRACT

BACKGROUND: Prosthesis-patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR) remains an important issue. The aim of this study was to assess the value of a new discongruence index, to predict PPM after TAVR.Methods and Results: A total of 185 patients with severe aortic stenosis who underwent TAVR with the Edwards Sapien prosthesis or CoreValve Revalving system were included (Edwards valve, n=119; Core Valve Revalving system, n=66). Discongruence index was calculated pre-procedurally as the ratio of selected transcatheter valve size (mm) to body surface area (cm2). PPM was defined as effective orifice area (EOA) ≤0.85 cm2/m2 on transthoracic echocardiography before hospital discharge. Mean age was 82±5 years and 72 patients (38.9%) were men. The overall incidence of post-TAVR PPM was 35.1% (n=65). Discongruence index correlated with post-TAVR indexed EOA (y=0.18+0.057x; P<0.001). On multivariate logistic regression analysis, discongruence index was the only independent predictor of post-TAVR PPM (OR, 0.15; 95% CI: 0.03-0.66; P=0.012), and the area under the receiver operating characteristic curve was 0.62 (95% CI: 0.54-0.70, P=0.003), with an optimal cut-off point of 15.02 (sensitivity, 86.2%; specificity, 72.5%; positive predictive value, 74.3%; negative predictive value, 83.4%). CONCLUSIONS: The new discongruence index may be useful tool to predict PPM after TAVR.


Subject(s)
Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Echocardiography , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Female , Humans , Male
SELECTION OF CITATIONS
SEARCH DETAIL
...