Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
J Ophthalmol ; 2015: 496382, 2015.
Article in English | MEDLINE | ID: mdl-26075085

ABSTRACT

Purpose. To thoroughly analyze corneal deformation responses curves obtained by Ocular Response Analyzer (ORA) testing in order to improve subclinical keratoconus detection. Methods. Observational case series of 87 control and 73 subclinical keratoconus eyes. Examination included corneal topography, tomography, and biomechanical testing with ORA. Factor analysis, logistic regression, and receiver operating characteristic curves were used to extract combinations of 45 corneal waveform descriptors. Main outcome measures were corneal-thickness-corrected corneal resistance factor (ccCRF), combinations of corneal descriptors, and their diagnostic performance. Results. Thirty-seven descriptors differed significantly in means between groups, and among them ccCRF afforded the highest individual diagnostic performance. Factor analysis identified first- and second-peak related descriptors as the most variable one. However, conventional biomechanical descriptors corneal resistance factor and hysteresis differed the most between control and keratoconic eyes. A combination of three factors including several corneal descriptors did not show better diagnostic performance than a combination of conventional indices. Conclusion. Multivariate analysis of ORA signals did not surpass simpler models in subclinical keratoconus detection, and there is considerable overlap between normal and ectatic eyes irrespective of the analysis model. Conventional biomechanical indices seem to already provide the best performance when appropriately considered.

2.
J Refract Surg ; 31(2): 116-23, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25735045

ABSTRACT

PURPOSE: To evaluate intereye corneal asymmetry in Pentacam (Oculus Optikgeräte GmbH, Wetzlar, Germany) indices as a diagnostic method between normal patients and patients with keratoconus. METHODS: A retrospective, observational case series of 177 healthy, 44 indeterminate, and 121 patients with keratoconus classified by Pentacam ectasia detection indices, randomized to analysis and validation datasets. Intereye asymmetry in 20 Scheimpflug tomography corneal descriptors was calculated and compared to develop diagnostic models. RESULTS: Intereye asymmetry was not correlated with anisometropia in healthy controls but was correlated with the ectasia grade of the worse eye in patients with keratoconus. Patients with keratoconus had significantly greater intereye asymmetry in all descriptors except for relational thickness indices. Intereye asymmetry in front elevation at the thinnest corneal location afforded the single highest diagnostic performance (71% sensitivity and 85% specificity), whereas the best multivariate model combining intereye asymmetry in anterior and posterior keratometry, corneal thickness, and front and back elevation at the thinnest point provided 65% sensitivity and 97% specificity. Multivariate models upheld their performance in the validation dataset. Most (more than 90%) indeterminate patients, according to conventional Pentacam analysis, showed within-normal-range corneal asymmetry. CONCLUSIONS: Healthy corneas are markedly symmetric irrespective of anisometropia, but corneal asymmetry analysis does not provide sufficient sensitivity to be used alone for detecting keratoconus. However, its remarkable specificity suggests that it could be used combined with conventional single cornea Pentacam analysis to reduce the false-positive rate or in dubious cases.


Subject(s)
Anisometropia/diagnosis , Cornea/pathology , Diagnostic Techniques, Ophthalmological , Keratoconus/diagnosis , Adult , Female , Humans , Male , Photography , ROC Curve , Retrospective Studies , Sensitivity and Specificity , Tomography , Young Adult
4.
J Refract Surg ; 30(1): 49-53, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24864328

ABSTRACT

PURPOSE: To evaluate inter-device agreement between Placido topography (iTrace; Tracey Technologies, Houston, TX) and Scheimpflug tomography (Pentacam; Oculus Optikgeräte GmbH, Wetzlar, Germany) for measuring corneal power and cylinder and axis of astigmatism. METHODS: Observational case series of 54 eyes from 54 subjects with no ocular disease. Main outcome measures were corneal power, cylinder power, and axis of astigmatism and their agreement was assessed by Bland­Altman analysis. RESULTS: For corneal power and corneal cylinder, 95% limits of agreement (LoA) were considered good (−0.38 to 0.45 diopters [D] and −0.49 to 0.27 D, respectively). In contrast, the 95% LoA for corneal astigmatism axis exceeded the clinically relevant margins (−14.8 to 13.5): 28 eyes (52%) had a greater than 5° difference, 10 eyes (19%) had a greater than 10° difference, and 4 eyes (7%) had a greater than 20° difference between instruments. This absolute difference was significantly correlated with average corneal cylinder (Spearman's r = −0.379, P = .005) but not with average corneal power. In eyes with corneal astigmatism 2 D or greater, the 95% LoA for axis were −8.7° to 6.7°, whereas in those with corneal astigmatism less than 1 D, the 95% LoA for axis were −19.1° to 16.6°. CONCLUSIONS: Placido topography and Scheimpflug tomography show good agreement for corneal power and cylinder, but not for corneal astigmatism axis. These instruments could be used interchangeably only in eyes with corneal astigmatism of 2 D or greater.


Subject(s)
Astigmatism/diagnosis , Cornea/pathology , Corneal Topography/methods , Adult , Astigmatism/physiopathology , Corneal Topography/instrumentation , Diagnostic Techniques, Ophthalmological/instrumentation , Female , Humans , Male , Reproducibility of Results , Tomography/methods
5.
Am J Ophthalmol ; 158(1): 32-40.e2, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24709808

ABSTRACT

PURPOSE: To evaluate Pentacam ectasia detection indices in topographically normal patients and in subclinical keratoconus cases. DESIGN: Prospective, observational case series. METHODS: setting: Institutional. patients: Group 1 comprised 1 eye from 189 patients with unremarkable topography and Groups 2 and 3 included the better and worse eyes, respectively, of 55 keratoconic patients. Group 2 eyes with normal topography (n = 37) were considered subclinical keratoconus cases. observation procedure: Pentacam Scheimpflug tomography. main outcome measures: Eleven Pentacam ectasia detection indices. RESULTS: All Pentacam ectasia indices significantly differed between Groups 1 and 2 and were correlated with keratoconus grade. Only 99 eyes (52%) in Group 1 had normal values for every index, whereas 7 subclinical keratoconus eyes (19%) showed 2 or fewer abnormal indices. Standardized relational thickness and overall deviation indices had 73% and 89% sensitivity for subclinical keratoconus, respectively. Both average and maximum pachymetric progression indices offered 84% sensitivity while maximum relational thickness index showed 78% sensitivity for subclinical keratoconus. Optimized cutoff values for subclinical keratoconus increased the sensitivity of the standardized and maximum relational thickness indices. CONCLUSION: Pentacam Scheimpflug tomography can detect most subclinical keratoconus cases with unremarkable topography, but performance is not as good as reported and varies considerably for each index. The overall deviation, average and maximum pachymetric progression, and maximum relational thickness indices offer the highest sensitivity, which can be improved by using optimized cutoff values. Specificity constitutes an issue for some indices and up to 10% of subclinical keratoconus cases may go undetected by this technology.


Subject(s)
Cornea/pathology , Corneal Topography/methods , Keratoconus/diagnosis , Adolescent , Adult , Aged , Corneal Pachymetry , Corneal Topography/instrumentation , Dilatation, Pathologic/diagnosis , Early Diagnosis , Female , Humans , Keratoconus/classification , Male , Middle Aged , Photography/methods , Prospective Studies , ROC Curve , Sensitivity and Specificity , Tomography , Young Adult
6.
J Refract Surg ; 29(9): 596-602, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23848186

ABSTRACT

PURPOSE: To evaluate corneal biomechanical properties in non-keratoconic myopic eyes and to identify descriptors for improving the specificity of the Ocular Response Analyzer (ORA) (Reichert Ophthalmic Instruments, Depew, NY) testing for subclinical keratoconus detection. METHODS: Observational case series of 52 non-keratoconic non-myopic eyes and 97 non-keratoconic myopic eyes (spherical equivalent < -5 diopters [D]) in dataset 1 and 87 non-keratoconic eyes and 73 eyes with subclinical keratoconus in dataset 2. Examination included corneal topography, tomography, and biomechanical testing with the ORA. Receiver operating characteristic curves and logistic regression were used to identify optimal combinations of biomechanical indices for keratoconus detection. Main outcome measures were corneal thickness-corrected hysteresis (DifCH) and resistance factor (DifCRF), the difference between these two (CH-CRF), and the diagnostic performance of their combinations. RESULTS: Compared to non-keratoconic non-myopic eyes, non-keratoconic myopic eyes with flat corneas (average corneal power < 44.0 D) had reduced DifCH (mean ± standard deviation, 0.11 ± 1.27 vs -0.79 ± 1.50, P < .01) and DifCRF (0.24 ± 1.16 vs -0.70 ± 1.59, P < .01) values, whereas non-keratoconic myopic eyes with steep corneas showed no difference. Keratoconic eyes exhibited lower DifCH and DifCRF values than non-keratoconic myopic eyes. Combinations of DifCH, DifCRF, and CH-CRF had increased specificity (> 80%) for subclinical keratoconus compared to the DifCRF index alone (71%). CONCLUSIONS: In biomechanical keratoconus screening, some non-keratoconic myopic eyes show altered ocular biomechanical properties and are identified as false-positive cases. The low specificity of DifCRF when dealing with these non-keratoconic eyes could be improved by considering additional biomechanical descriptors such as DifCH and CH-CRF, which seem to be indicative of the aforementioned biomechanical profile.


Subject(s)
Cornea/physiopathology , Keratoconus/diagnosis , Myopia/diagnosis , Adult , Cornea/pathology , Corneal Topography , Elasticity , Follow-Up Studies , Humans , Keratoconus/physiopathology , Male , Myopia/physiopathology , ROC Curve , Severity of Illness Index
SELECTION OF CITATIONS
SEARCH DETAIL
...