Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Publication year range
1.
Eur Radiol ; 29(9): 5063-5072, 2019 Sep.
Article in English | MEDLINE | ID: mdl-30796575

ABSTRACT

OBJECTIVES: To compare Gd-EOB-DTPA dynamic hepatocyte-specific contrast-enhanced MRI (DHCE-MRI) with 99mTc-mebrofenin hepatobiliary scintigraphy (HBS) as quantitative liver function tests for the preoperative assessment of patients undergoing liver resection. METHODS: Patients undergoing liver surgery and preoperative assessment of future remnant liver (FRL) function using 99mTc-mebrofenin HBS were included. Patients underwent DHCE-MRI. Total liver uptake function was calculated for both modalities: mebrofenin uptake rate (MUR) and Ki respectively. The FRL was delineated with both SPECT-CT and MRI to calculate the functional share. Blood samples were taken to assess biochemical liver parameters. RESULTS: A total of 20 patients were included. The HBS-derived MUR and the DHCE-MRI-derived mean Ki correlated strongly for both total and FRL function (Pearson r = 0.70, p = 0.001 and r = 0.89, p < 0.001 respectively). There was a strong agreement between the functional share determined with both modalities (ICC = 0.944, 95% CI 0.863-0.978, n = 20). There was a significant negative correlation between liver aminotransferases and bilirubin for both MUR and Ki. CONCLUSIONS: Assessment of liver function with DHCE-MRI is comparable with that of 99mTc-mebrofenin HBS and has the potential to be combined with diagnostic MRI imaging. This can therefore provide a one-stop-shop modality for the preoperative assessment of patients undergoing liver surgery. KEY POINTS: • Quantitative assessment of liver function using hepatobiliary scintigraphy is performed in the preoperative assessment of patients undergoing liver surgery in order to prevent posthepatectomy liver failure. • Gd-EOB-DTPA dynamic hepatocyte-specific contrast-enhanced MRI (DHCE-MRI) is an emerging method to quantify liver function and can serve as a potential alternative to hepatobiliary scintigraphy. • Assessment of liver function with dynamic gadoxetate-enhanced MRI is comparable with that of hepatobiliary scintigraphy and has the potential to be combined with diagnostic MRI imaging.


Subject(s)
Gadolinium DTPA/pharmacology , Liver Diseases/diagnosis , Liver/diagnostic imaging , Radionuclide Imaging/methods , Tomography, Emission-Computed, Single-Photon/methods , Aged , Female , Hepatectomy , Humans , Liver Diseases/surgery , Liver Function Tests/methods , Magnetic Resonance Imaging/methods , Male , Middle Aged , Pilot Projects , Prospective Studies , Radiopharmaceuticals/pharmacology
2.
NMR Biomed ; 31(10): e3932, 2018 10.
Article in English | MEDLINE | ID: mdl-29846986

ABSTRACT

This review on magnetic resonance elastography (MRE) of the breast provides an overview of available literature and describes current developments in the field of breast MRE, including new transducer technology for data acquisition and multi-frequency-derived power-law behaviour of tissue. Moreover, we discuss the future potential of breast MRE, which goes beyond its original application as an additional tool in differentiating benign from malignant breast lesions. These areas of ongoing and future research include MRE for pre-operative tumour delineation, staging, monitoring and predicting response to treatment, as well as prediction of the metastatic potential of primary tumours.


Subject(s)
Breast/diagnostic imaging , Elasticity Imaging Techniques , Magnetic Resonance Imaging , Elastic Modulus , Humans , Publications
3.
Ned Tijdschr Geneeskd ; 160: D337, 2016.
Article in Dutch | MEDLINE | ID: mdl-27531248

ABSTRACT

Five years ago, we reported on the use of 1H-magnetic resonance spectroscopy (MRS-PDFF) as a non-invasive means of determining the amount of liver fat. Liver biopsy, the current reference method, has several shortcomings (e.g. risk of complications and large interobserver variability), which are less pronounced or absent in MRS-PDFF. In RCT's, MRS-PDFF is currently used as an outcome measure to assess therapy response. Its successor is already being deployed: MRI-PDFF. This is a short whole-liver MRI scan, which takes approximately 18 seconds. The use of MRS- or MRI-PDFF has not boomed in the Netherlands. Reasons include unfamiliarity with the technique amongst both clinicians and radiologists, as well as increased reliance on ultrasound imaging with Fibroscan by hepatologists in particular. This latter method, however, is less accurate in classifying the various steatosis grades than MRS- and MRI-PDFF.


Subject(s)
Fatty Liver/diagnostic imaging , Liver/diagnostic imaging , Magnetic Resonance Spectroscopy/methods , Biopsy , Fatty Liver/pathology , Humans , Netherlands
SELECTION OF CITATIONS
SEARCH DETAIL